MAURY USCG vessel records
← All vessels

ISLANDER EXPRESS

Built
1994
Last inspected
28 January 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 January 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8967876
WCJ6211
401898
Flag
UNITED STATES
Maury page id
psix-401898

Documentation record

Registered dimensions (L × B × D)88.7 ft × 22.6 ft × 8.9 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)88.7 ft × 22.6 ft × 8.9 ft
ITC tonnagegross 203 / net 70
BuilderWESTPORT SHIPYARD INC · WESTPORT, WA, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portAVALON, CA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 5 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it203 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
70 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 31 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 31

28 January 2026 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8235610
12 February 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8024889
4 December 2024 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8005005
5 June 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7923368
29 November 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7802023
14 July 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7739424
27 June 2023 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7725190
25 May 2023 Drydock Exam · In-Service Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7696754
12 January 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7613495
23 June 2022 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7471370
1 June 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7465843
28 December 2021 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7373515
15 December 2021 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7364996
30 November 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7359766
26 May 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7207750
19 April 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7178705
26 February 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7220843
25 February 2021 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7146616
5 March 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6877397
29 January 2020 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6898611
28 August 2019 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6797700
25 August 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6842102
6 March 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6617454
3 April 2018 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6385461
15 February 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6350817
30 January 2018 Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6345837
28 November 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6314220
24 April 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6132683
6 January 2017 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6062853
7 April 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5828543
18 February 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5809911

Deficiency record · 14

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 February 2025 Resolved
At each initial and subsequent inspection for certification and reinspection the firefighting equipment of all vessels shall be inspected and all deficiencies found shall be corrected. Marine inspector identified a leak in the fire main.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 13 February 2025
Resolution: Repairs completed to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2025 Resolved
Valves for removing water or impurities from fuel in watertraps or strainers will be permitted. Such valves shall be provided with caps or plugs to prevent fuel leakage. Marine Inspector identified a leak in the port generator strainer.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 13 February 2025
Resolution: Repairs completed to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 December 2021 Resolved
Fire pump unable to reach 60 psi. Corrected on the spot
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 15 December 2021
Resolved 15 December 2021
Resolution: Corrected on the spot
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 April 2021 Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date of the COI. Vessel exceeded 3 month interval on 06APR2021. Vessel required to complete a satisfactory annual inspection prior to departure or carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2021
Resolved 1 July 2021
Resolution: def cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 February 2021 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it was installed and capable of operations at constant marine load under such requirements without exceeding its designed limitations. Vessel suffered loss of propulsion on its starboard engine while underway. Vessel to prove proper operation of propulsion machinery prior to departure or carraige of passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2021
Resolved 26 May 2021
Resolution: def cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 August 2019 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which is is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel reported loss of port engine. Conduct appropriate repairs to port engine and prove proper operation of port engine and propulsion system to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2019
Resolved 10 March 2020
Resolution: Conducted sea trials and verified proper operation of new port MDE. All engine parameters within manufacturers specifications.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 30 January 2018 Resolved
Make final repair to strut mount locations available for inspection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 1 February 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 January 2017 Resolved
Remove or make safe the dead end wire in the aft electrical closet.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 13 January 2017
Resolution: Cable removed
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 6 January 2017 Resolved
Provide schematic drawing for fir firefighting system detailing methods of release at or near the pull station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 13 January 2017
Resolution: Schematic posted
Engineering › Lubricating Oil Service System › Filter
Issued 6 January 2017 Resolved
Repair hydraulic leaks on the ride control system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 13 January 2017
Resolution: Seals replaced. Conduct OP test, all sat.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 6 January 2017 Resolved
Repair penetrations on two buoyant apparatuses.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 6 January 2017
Operations/Management › Pollution › Retention of Oily Mixture
Issued 7 April 2016 Resolved
Ensure provisions are made to retain all oily mixtures on board.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 April 2016
Resolved 12 April 2016
Resolution: Operator installed positive shutoff valves on all rule pumps on board and also disabled the automatic feature on the rule pumps.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 April 2016 Resolved
Make permanent repairs to the port side raw water piping, for cooling port main diesel engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 12 April 2016
Resolution: Operator removed temporary epoxy repair to raw water piping and discovered that there was no damage to the pipe and no permanent repairs required.
Fire Fighting › Combustible Materials › Insulation
Issued 7 April 2016 Resolved
Provide insulation on exhaust brackets for both main diesel engines to prevent injuries.
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 12 April 2016
Resolution: Operator installed insulation on the echaust brackets for both main diesel engines.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.