Records from 2017 to 2025. Most recent: inspection, 27 March 2025.
Inspection history · 5
27 March 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8100516
1 July 2021
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7241485
26 May 2020
Administrative Inspection · Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6960674
18 December 2019
Deficiency Check · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6876568
13 March 2017
Examination of Repairs · DAPI Audit · Internal Structural Exam · Deficiency Check · COI Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6108613
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 July 2021
No resolution recorded
Vessel has missed its window for annual inspection. COI is no longer vailed and must complete a COI inspection prior to carrying passengers.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2021 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 May 2020
Resolved
07 ADULT LIFE JACKETS ARE MISSING. THE VESSEL IS RESTRICTED TO NOT MORE THAN 17 TOTAL PERSONS UNTIL NEW JACKETS ARE PROVIDED.
Action required: 705 - Other - as specified
Resolved 10 July 2020
Resolution: New life jackets were provided and inspected sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 May 2020
Resolved
Navigation lights are inoperable, repair/renew prior to operation at night.
Action required: 705 - Other - as specified
Resolved 10 July 2020
Resolution: Navigation lights were renewed and tested all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 May 2020
Resolved
Emergency Instructions list is missing. Provide and post.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2020
Resolution: Emergency instructions list was provided and posted.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 26 May 2020
Resolved
Life jacket donning placard does not match the type of jackets onboard. Provide and post the donning placard that matches each type of jacket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2020
Resolution: Vessel posted new donning placards for each different type of PFD.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 26 May 2020
Resolved
VHF does not provide a lat and long position. Link the VHF or renew with a integrated GPS signal.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2020
Resolution: GPS integrated VHF was provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 26 May 2020
Resolved
Emergency radio proceedures sign is missing. Provide and post near the VHF radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2020
Resolution: Emergency radio proceedures were posted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 May 2020
Resolved
Batteries are not mounted in a protective box. Install a battery box for each battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2020
Resolution: Batteries were properly stored in battery boxes and secured to the vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 May 2020
Resolved
remote fuel shut off valves are not marked. Mark per 46CFR185.608.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2020
Resolution: Remote fuel valves have been properly marked.
Communications › Alarms/Indicators › High Water Alarm
Issued 21 March 2017
Resolved
STBD hull High level alarm visual indicator is extinguished.
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 4 April 2017
Resolution: New bilge alarms were installed and tested all sat.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 21 March 2017
Resolved
Fuel Vent is missing the flame screen. Renew/repair.
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 4 April 2017
Resolution: New screens were installed in both tanks.
Engineering › Steering Gear System › Ram
Issued 21 March 2017
Resolved
Both steering rams are loose and must be repaired.
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 4 April 2017
Resolution: Steering system was missing spacers, spacers were installed and tested. All sat.