MAURY USCG vessel records Sign in
← All vessels

BEACH CAT

BEACH CAT is a 1994 passenger vessel (inspected). The Coast Guard has recorded 40 inspections since 1994, most recently in March 2025, along with 146 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 1994 to 2025. Most recent: inspection, 27 March 2025.

Built
1994
Last inspected
27 March 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC7637
401919
Flag
UNITED STATES
—
Maury page id
psix-401919

Inspections, by type

…with no type recorded3
…past their stated due date1
Years with a record 24 calendar years (1994–2025)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
3 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 40

27 March 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8100516
1 July 2021 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7241485
26 May 2020 Administrative Inspection · Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6960674
18 December 2019 Deficiency Check · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6876568
13 March 2017 Examination of Repairs · DAPI Audit · Internal Structural Exam · Deficiency Check · COI Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6108613
19 October 2015 Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5745823
17 January 2012 Deficiency Check · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4225728
5 July 2011 COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4070299
10 March 2010 Hull Examination · Drydock Exam · Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3694485
10 February 2010 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3677920
6 May 2009 Deficiency Check · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3462997
12 May 2008 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3189927
26 July 2007 Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3007222
17 May 2007 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2931837
2 September 2005 COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2565107
21 July 2005 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2434039
25 May 2004 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2078972
10 March 2004 Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2021823
29 July 2003 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1862727
19 March 2003 COI Inspection · Hull Examination · Deficiency Check · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1755130
2 August 2002 Deficiency Check · MARPOL Annex V Examination · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1655480
4 September 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1072643
10 July 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1395793
20 June 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 26591
20 February 2001 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1425078
6 February 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1391474
17 October 2000 Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1406802
28 September 2000 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1054978
25 September 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 84097
24 February 2000 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1430822
16 February 1999 MARPOL Annex V Examination · Re-Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1416835
17 March 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1110488
4 March 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1106755
22 February 1997 MARPOL Annex V Examination · Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1105987
12 March 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 884560
27 February 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 885786
23 February 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 848239
31 January 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 829807
29 June 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1133600
12 February 1994 Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1163475

Deficiency record · 146

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 July 2021 No resolution recorded
Vessel has missed its window for annual inspection. COI is no longer vailed and must complete a COI inspection prior to carrying passengers.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2021 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 May 2020 Resolved
07 ADULT LIFE JACKETS ARE MISSING. THE VESSEL IS RESTRICTED TO NOT MORE THAN 17 TOTAL PERSONS UNTIL NEW JACKETS ARE PROVIDED.
Action required: 705 - Other - as specified
Resolved 10 July 2020
Resolution: New life jackets were provided and inspected sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 May 2020 Resolved
Navigation lights are inoperable, repair/renew prior to operation at night.
Action required: 705 - Other - as specified
Resolved 10 July 2020
Resolution: Navigation lights were renewed and tested all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 May 2020 Resolved
Emergency Instructions list is missing. Provide and post.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2020
Resolution: Emergency instructions list was provided and posted.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 26 May 2020 Resolved
Life jacket donning placard does not match the type of jackets onboard. Provide and post the donning placard that matches each type of jacket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2020
Resolution: Vessel posted new donning placards for each different type of PFD.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 26 May 2020 Resolved
VHF does not provide a lat and long position. Link the VHF or renew with a integrated GPS signal.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2020
Resolution: GPS integrated VHF was provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 26 May 2020 Resolved
Emergency radio proceedures sign is missing. Provide and post near the VHF radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2020
Resolution: Emergency radio proceedures were posted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 May 2020 Resolved
Batteries are not mounted in a protective box. Install a battery box for each battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2020
Resolution: Batteries were properly stored in battery boxes and secured to the vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 May 2020 Resolved
remote fuel shut off valves are not marked. Mark per 46CFR185.608.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2020
Resolution: Remote fuel valves have been properly marked.
Communications › Alarms/Indicators › High Water Alarm
Issued 21 March 2017 Resolved
STBD hull High level alarm visual indicator is extinguished.
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 4 April 2017
Resolution: New bilge alarms were installed and tested all sat.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 21 March 2017 Resolved
Fuel Vent is missing the flame screen. Renew/repair.
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 4 April 2017
Resolution: New screens were installed in both tanks.
Engineering › Steering Gear System › Ram
Issued 21 March 2017 Resolved
Both steering rams are loose and must be repaired.
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 4 April 2017
Resolution: Steering system was missing spacers, spacers were installed and tested. All sat.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 17 January 2012 Resolved
Deck hatches must be watertight.
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 19 January 2012
Construction/Loadline › Hull › Side Shell
Issued 17 January 2012 Resolved
Make damaged area on bow available for inspection.
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 19 January 2012
Construction/Loadline › Hull › Side Shell
Issued 17 January 2012 Resolved
Submit repair plan for damaged bow area.
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 18 January 2012
Resolution: Repair plan for damaged bow area received and approved.
Construction/Loadline › Hull › Bracket
Issued 17 January 2012 Resolved
Install means to eliminate anchor damage on bow.
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 19 January 2012
Construction/Loadline › Hull › Side Shell
Issued 17 January 2012 Resolved
Repair damage to portside rubrail.
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 19 January 2012
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 5 July 2011 Resolved
Acquire valid DOT approved alcohol testing devices.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 11 July 2011
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 5 July 2011 Resolved
Re label child PFDs.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 11 July 2011
Communications › Visual Communication › Warning Sign (radio room)
Issued 5 July 2011 Resolved
Post Marpol placard.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 11 July 2011
Lifesaving › Hand Flares › Quantity
Issued 5 July 2011 Resolved
Acquire 01 flare.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 11 July 2011
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 5 July 2011 Resolved
Clean vessel; curently unsanitary infested with cockroaches.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 11 July 2011
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 5 July 2011 Resolved
Acquire 02 BII portable fire extinguishers.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 11 July 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 July 2011 Resolved
Stern light must be visible
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 11 July 2011
Communications › Alarms/Indicators › High Water Alarm
Issued 5 July 2011 Resolved
Install highwater level alarms & indicators on engine mounting compartments.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 11 July 2011
Stability › Unintentional Flooding › General
Issued 5 July 2011 Resolved
Attach gasket to port deck hatch.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 11 July 2011
Fire Fighting › Fire Bucket › Quantity
Issued 5 July 2011 Resolved
Vessel must have 03 fire buckets.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 11 July 2011
Stability › Water on Deck › General
Issued 5 July 2011 Resolved
Freeing ports must remain clear of obstruction.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 11 July 2011
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 July 2011 Resolved
Install center rail on portside entrance.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 11 July 2011
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 July 2011 Resolved
Replace batteries in strobe lights.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 11 July 2011
Lifesaving › Lifefloat › Paddle
Issued 5 July 2011 Resolved
Label paddles on lifefloat with vessel name.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 11 July 2011
Lifesaving › Lifefloat › Paddle
Issued 5 July 2011 Resolved
Attach lanyard to paddles from lifefloat.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 11 July 2011
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 July 2011 Resolved
Install emergency fuel shutdowns.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 11 July 2011
Stability › Unintentional Flooding › General
Issued 5 July 2011 Resolved
Acquire adequate portable hand pump.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 11 July 2011
Communications › Radio Communications › VHF Radiotelephone
Issued 5 July 2011 Resolved
VHF radio should be powered by batteries stowed in a safe location.
Action required: 705 - Other - as specified
Due 7 July 2011
Resolved 11 July 2011
Documentation › Certificates/Documents › FCC SSL
Issued 17 March 2010 Resolved
Missing FCC station license. Obtain new license.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2010
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 17 March 2010 Resolved
Missing FCC Marine Radar Operator Permit. Obtain FCC permit.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 March 2010 Resolved
Post COI in a conspicuous place.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2010
Documentation › Certificates/Documents › Stability Letter
Issued 17 March 2010 Resolved
Missing Stability Letter posted in conspicuous place. Post Stability Letter conspicuously.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 March 2010 Resolved
SPV Decal (outdated) needs to be removed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 17 March 2010 Resolved
Missing proof of drug/alcohol testing program enrollment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 17 March 2010 Resolved
Missing means of alcohol testing onboard or readily accessible.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2010
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 March 2010 Resolved
Need inspected CO2 fire extinguisher onboard at operating station.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Personnel › Certificates/Documents/Licenses › License, Master
Issued 17 March 2010 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 17 March 2010 Resolved
Missing proof of First Aid/CPR training for 50% of crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 17 March 2010 Resolved
Missing proof of First Aid/CPR training for 50% of crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Documentation › Logs/Records › Logbook (official)
Issued 17 March 2010 Resolved
Missing log of training.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 March 2010 Resolved
Missing log of emergency training/drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Documentation › Logs/Records › Logbook (official)
Issued 17 March 2010 Resolved
Missing log of Lifesaving Equipment maintenance.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Navigation › Piloting/Steering › Coast Guard Light List
Issued 17 March 2010 Resolved
Outdated CG Light List.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 17 March 2010 Resolved
Missing tides/currents tables.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 17 March 2010 Resolved
Missing bell (sounding device).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Lifesaving › Visual Distress Signals (General) › Marking
Issued 17 March 2010 Resolved
Container not marked with "Distress Signals."
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Lifesaving › Hand Flares › Quantity
Issued 17 March 2010 Resolved
Missing 4 smoke flares and 2 hand held flares.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Documentation › Markings/Placards › Warning Signs
Issued 17 March 2010 Resolved
Missing vessel specific information on Emergency Broadcast placard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Communications › Radio Communications › EPIRB
Issued 17 March 2010 Resolved
Relocate EPIRB to float-free area.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Communications › Radio Communications › EPIRB
Issued 17 March 2010 Resolved
No hydrostatic release on EPIRB.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Stability › Incline Test › General
Issued 17 March 2010 Resolved
Provide documentation of weight changes from changing out outboard motors.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Stability › Incline Test › General
Issued 17 March 2010 Resolved
Provide configuration for kayak stowage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Construction/Loadline › Hull › Hull Plating
Issued 17 March 2010 Resolved
Submit repair plans for fwd stbd pontoon hole.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 March 2010 Resolved
Obtain CG approved First Aid kit.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 17 March 2010 Resolved
Replace retroreflective tape on 05 child and 06 adult PFDs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Lifesaving › Lifebuoys › Approval
Issued 17 March 2010 Resolved
Obtain lifebuoy w/60 ft of line and retroreflective tape.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Lifesaving › Lifefloat › Retroreflective Material
Issued 17 March 2010 Resolved
Attach retroreflective tape to life float.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Lifesaving › Lifefloat › Markings
Issued 17 March 2010 Resolved
Erase old vessel name from markings on lifefloat.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2010
Resolved 7 May 2010
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 17 March 2010 Resolved
Mount operable lifefloat light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Lifesaving › Lifefloat › Float-free Link
Issued 17 March 2010 Resolved
Add painter line and weak link to lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Fire Fighting › Fire Bucket › Lanyard
Issued 17 March 2010 Resolved
Attach lanyard to 01 fire bucket.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Engineering › Bilge Water Management System › Pump
Issued 17 March 2010 Resolved
Obtain portable bilge pump.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 17 March 2010 Resolved
Rewire bilge alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 March 2010 Resolved
Conduct drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2010
Stability › Incline Test › General
Issued 10 March 2010 Resolved
KW01 The vessel must undergo a new stability test do to the added weight of 320 lbs up high and a previous simplified stability test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Resolution: Vessel has an approved stability letter and will not undergo new incline stability test at this time.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 10 March 2010 Resolved
KW02 Vessel must install watertight plugs in crash bulkheads.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Construction/Loadline › Penetrations › Bottom Plug
Issued 10 March 2010 Resolved
KW03 Vessel has a deck leak on the portside deck leaking into the portside hull. Penetrations must be repaired and water tight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 10 March 2010 Resolved
KW04 Wire penetrations through the hull to the outboard motors must be watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Engineering › Gasoline Engine (propulsion) › Intake Port (4 cycle)
Issued 10 March 2010 Resolved
Complete installation of outboard motors.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2010
Resolved 7 May 2010
Documentation › Markings/Placards › Lifejacket Placard
Issued 10 March 2010 Resolved
Post lifejacket donning placard.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Lifesaving › Lifefloat › Paddle
Issued 10 March 2010 Resolved
Add 2 4' paddles w/vessel name labeled on the lifefloat.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2010
Construction/Loadline › Penetrations › Gasket
Issued 1 February 2010 Resolved
Replace damaged hatches fwd and repair leaks main deck hatches.
Action required: 705 - Other - as specified
Resolved 7 May 2010
Communications › Radio Communications › EPIRB
Issued 6 May 2008 Resolved
Properly mount EPIRB in a float free arrangement.
Action required: 705 - Other - as specified
Resolved 16 May 2008
Resolution: CLEARED
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 May 2008 Resolved
Post lifejacket donning placard.
Action required: 705 - Other - as specified
Resolved 16 May 2008
Resolution: CLEARED
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 6 May 2008 Resolved
Properly mount all fire extinguishers.
Action required: 705 - Other - as specified
Resolved 16 May 2008
Resolution: CLEARED
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 May 2008 Resolved
Post all required documents/certificates in passenger view.
Action required: 705 - Other - as specified
Resolved 16 May 2008
Resolution: CLEARED
Engineering › Steering Gear System › Linkage
Issued 6 May 2008 Resolved
Prior to the carriage of passengers, make permanent repairs to the steering system and demonstrate all emergency drills in the presence of a CG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 16 May 2008
Resolution: CLEARED
Engineering › Bilge Water Management System › Not Installed
Issued 17 May 2007 Resolved
LABLE HIGH LEVEL BILGE ALARMS AT THE OPERATOR CONSOLE
Action required: 705 - Other - as specified
Resolved 17 May 2007
Resolution: CLEARED
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 17 May 2007 Resolved
BLANK OFF UNUSED SWITCHES AT OPERATORS CONSOLE
Action required: 705 - Other - as specified
Resolved 17 May 2007
Resolution: CLEARED
Electrical › Electrical Distribution System (service) › Junction Box
Issued 17 May 2007 Resolved
PROVIDE COVER FOR BATTERY BOX UNDER CONSOLE
Action required: 705 - Other - as specified
Resolved 17 May 2007
Resolution: BATTERY AND WIRING REMOVED
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 17 May 2007 Resolved
PROVIDE COVER FOR BATTERY BOX / PORT HULL
Action required: 705 - Other - as specified
Resolved 17 May 2007
Resolution: CLEARED
Electrical › Electric Generation Source (service) › Switch
Issued 17 May 2007 Resolved
REPLACE WING NUTS WITH HEX NUTS ON ALL BATTERIES
Action required: 705 - Other - as specified
Resolved 17 May 2007
Resolution: CLEARED
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 May 2007 Resolved
REPLACE NON CORROSIVE CLIP WITH 3'-6' LANYARD.
Action required: 705 - Other - as specified
Resolved 17 May 2007
Resolution: CLEARED
Documentation › Logs/Records › Drug Test Records
Issued 17 May 2007 Resolved
PROVIDE MIS REPORT FOR 2006.
Action required: 705 - Other - as specified
Resolved 17 May 2007
Resolution: CLEARED
Engineering › Bilge Water Management System › Pump
Issued 10 January 2006 Resolved
Make both bilge pumps, port and starboard operational prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 January 2006
Resolved 15 February 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 10 January 2006 Resolved
Properly mount all fire extinguishers prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 January 2006
Resolved 15 February 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 10 January 2006 Resolved
Provide FCC safety radio telephony certificate.
Action required: 705 - Other - as specified
Due 10 January 2006
Resolved 15 February 2006
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 10 January 2006 Resolved
Provide FCC Marine operators permit
Action required: 705 - Other - as specified
Due 3 March 2006
Resolved 2 March 2006
Resolution: cleared
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 10 January 2006 Resolved
Provide 9 additional adult type I lifejackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 January 2006
Resolved 15 February 2006
Personnel › Training › Familiarization Training
Issued 10 January 2006 Resolved
Conduct emergency drills in the presence of a CG marine inspector.
Action required: 705 - Other - as specified
Due 16 January 2006
Resolved 15 February 2006
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 10 January 2006 Resolved
Provide proof of enrollment in a drug consortium.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 January 2006
Resolved 15 February 2006
Documentation › Certificates/Documents
Issued 10 March 2004 Resolved
Provide proof of valid FCC Station License. LEGACY COMPONENT DESC: FCC SSL
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2004
Resolved 25 May 2004
Resolution: Corrected
Documentation › Logs/Records
Issued 10 March 2004 Resolved
Create and maintain a training and safety equipment maintenance logbook. LEGACY COMPONENT DESC: Training and Safety Equipment Maintenance
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2004
Resolved 25 May 2004
Resolution: Corrected, will further evaluate during next exam.
Lifesaving › Buoyant Apparatus
Issued 10 March 2004 Resolved
Repair lifefloat in accordance with manufacturer's recommendations. LEGACY COMPONENT DESC: Lifefloat
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2004
Resolved 25 May 2004
Resolution: Corrected.
Navigation › Collision/Grounding Avoidance
Issued 10 March 2004 Resolved
Align stern light so that the light beam angle is directed horizontally. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 10 April 2004
Resolved 25 May 2004
Resolution: Corrected.
Navigation › Piloting/Steering
Issued 10 March 2004 Resolved
Provide copys of navigation publications. LEGACY COMPONENT DESC: Navigation Publications
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2004
Resolved 25 May 2004
Resolution: Excerpts provided.
Deck/Cargo › Mooring/Anchoring
Issued 10 March 2004 Resolved
Provide a new anchor of appropriate size for vessel. LEGACY COMPONENT DESC: Anchor
Action required: 705 - Other - as specified
Due 10 April 2004
Resolved 25 May 2004
Resolution: Corrected.
Engineering › Bilge Water Management System
Issued 10 March 2004 Resolved
Equip the portable bilge pump with enough discharge hose so that water can be removed from bilge effectively. LEGACY COMPONENT DESC: Portable Bilge Pump
Action required: 705 - Other - as specified
Due 10 April 2004
Resolved 25 May 2004
Resolution: Corrected.
Fire Fighting › Miscellaneous Items
Issued 10 March 2004 Resolved
Provide 3 fire buckets with attached lanyards. LEGACY COMPONENT DESC: Fire Buckets
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2004
Resolved 25 May 2004
Resolution: Corrected.
Documentation › Certificates/Documents
Issued 19 March 2003 Resolved
Provide a valid FCC Radio Operator's Permit for [name withheld] COMPONENT DESC: FCC SSL
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 29 July 2003
Resolution: Observed FCC Marine Radio Operator Permit for vessel [name withheld] [name withheld] is no longer the Captain of SPV KEY CAT.
Documentation › Certificates/Documents
Issued 19 March 2003 Resolved
Provide a valid FCC Radio Safety Cert. LEGACY COMPONENT DESC: FCC SSL
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 26 March 2003
Resolution: Corrected. Received fax copy of Radio Safety Cert.
Navigation › Piloting/Steering
Issued 19 March 2003 Resolved
Provide U.S Coat Pilot [name withheld], Tide Tables, Current Tables & Nav. Rules. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 29 July 2003
Resolution: Observed all required navigation publications.
Documentation › Certificates/Documents
Issued 19 March 2003 Resolved
Post Stability Letter. LEGACY COMPONENT DESC: Stability Letter
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 29 July 2003
Resolution: Observed Stability Letter posted onboard the vessel.
Documentation › Certificates/Documents
Issued 2 August 2002 Resolved
Provide a valid FCC Radio Safety Certificate, Station License & Operator's Permit. LEGACY COMPONENT DESC: FCC SSL
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 August 2002
Resolved 9 August 2002
Resolution: Corrected.
Lifesaving › Lifebuoys
Issued 2 August 2002 Resolved
Renew lines on ringbuoy and repair waterlight for life float. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2002
Resolved 9 August 2002
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (General)
Issued 2 August 2002 Resolved
Properly stencil PFD stowage lockers. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2002
Resolved 9 August 2002
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (General)
Issued 2 August 2002 Resolved
Renew retroreflective tape on all adult PFD's and re-stencil vessel's name. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2002
Resolved 9 August 2002
Resolution: Corrected.
Operations/Management › Drug and Alcohol Testing
Issued 2 August 2002 Resolved
Provide proof of a valid drug testing program. LEGACY COMPONENT DESC: Proof of Enrollment
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 August 2002
Resolved 9 August 2002
Resolution: Corrected.
Lifesaving › Buoyant Apparatus
Issued 2 August 2002 Resolved
Renew paddles for life float & re-stencil vessel's name and capacity on life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2002
Resolved 9 August 2002
Resolution: Corrected.
Communications › Radio Communications
Issued 2 August 2002 Resolved
Renew battery & hydrostatic release on EPIRB. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 9 August 2002
Resolved 9 August 2002
Resolution: Corrected.
Construction/Loadline › Hull
Issued 2 August 2002 Resolved
Make permanent repairs to damaged areas of starboard rubrail. LEGACY COMPONENT DESC: Side Shell
Action required: 705 - Other - as specified
Due 9 October 2002
Resolved 13 March 2003
Resolution: Corrected.
Documentation › Certificates/Documents
Issued 2 August 2002 Resolved
Provide & post Stability Letter. LEGACY COMPONENT DESC: Stability Letter
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 August 2002
Resolved 9 August 2002
Resolution: Corrected.
Operations/Management › Drills/Instruction
Issued 2 August 2002 Resolved
Provide a log book with proper entries for conducting emergency drills. LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 August 2002
Resolved 9 August 2002
Resolution: Corrected.
Operations/Management › Drills/Instruction
Issued 2 August 2002 Resolved
Post emergency instruction list.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 August 2002
Resolved 9 August 2002
Resolution: Corrected.
Navigation › Piloting/Steering
Issued 2 August 2002 Resolved
Provide updated charts for operating area. LEGACY COMPONENT DESC: Local Notices to Mariners
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 August 2002
Resolved 9 August 2002
Resolution: Corrected.
Operations/Management › Drills/Instruction
Issued 2 August 2002 Resolved
Conduct emergency drills in the presence of a USCG Marine Inspector. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 705 - Other - as specified
Due 9 August 2002
Resolved 9 August 2002
Resolution: Corrected.
Documentation
Issued 10 July 2001 Resolved
Marine Employer's drug testing program does not meet the requirements of 46CFR 16 and 49 CFR 40. Provide documentation to prove the Marine Employer's drug testing program complies with applicable Coast Guard and DOT regulations and that all employees are enrolled in the program.
Condition: Unknown
Due 10 August 2001
Resolved 16 August 2001
Documentation
Issued 10 July 2001 Resolved
Vessel operator unable to provide proof of a valid FCC operators permit. Provide proof vessel's licensed master holds a valid FCC operators permit.
Condition: Unknown
Due 10 July 2001
Resolved 10 July 2001
Lifesaving
Issued 10 July 2001 Resolved
Vessel's EPIRB not registered with NOAA. Provide proof vessel's EPIRB has been registered with NOAA.
Condition: Unknown
Due 10 August 2001
Resolved 16 August 2001
Documentation
Issued 10 July 2001 Resolved
Vessel had no FCC Radio Safety Certificate at time of inspection. Provide proof of valid certificate.
Condition: Unknown
Due 30 August 2001
Resolved 22 August 2001
Documentation
Issued 20 February 2001 Resolved
Provide a current FCC Safety Certificate, an FCC Station License and an FCCOperators Permit._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 March 2001
Resolved 28 February 2001
Lifesaving
Issued 20 February 2001 Resolved
Re-register the EPIRB with NOAA._x001C_ _x001C_ This item to be corrected prior to carrying passengers for hire._x001C_ _x001C_
Condition: Unknown
Due 6 March 2001
Resolved 28 February 2001
Documentation
Issued 20 February 2001 Resolved
Provide a current drug testing program._x001C_ _x001C_ This item to be corrected prior to carrying passengers for hire._x001C_ _x001C_
Condition: Unknown
Due 6 March 2001
Resolved 28 February 2001
Lifesaving
Issued 20 February 2001 Resolved
Affix new retro-reflective tape and re-mark the vessel name on all PFDs._x001C_ _x001C_ This item ti be corrected prior to carrying passengers for hire._x001C_ _x001C_
Condition: Unknown
Due 6 March 2001
Resolved 28 February 2001
Navigation
Issued 20 February 2001 Resolved
Provide a lighted compass._x001C_ _x001C_ Vessel restricted to daylight ops until this item is corrected._x001C_ _x001C_
Condition: Unknown
Due 6 March 2001
Resolved 28 February 2001
Navigation
Issued 20 February 2001 Resolved
Repair the anchor light._x001C_ _x001C_ The vessel is restricted to daylight ops until this item is corrected._x001C_ _x001C_
Condition: Unknown
Due 6 March 2001
Resolved 28 February 2001
Documentation
Issued 20 February 2001 Resolved
Provide a vessel logbook with all required entries._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 March 2001
Resolved 28 February 2001
Lifesaving
Issued 20 February 2001 Resolved
Affix new retro-reflective tape on the life ring buoy and the L/F._x001C_ _x001C_ This item to be corrected prior to carrying passengers for hire._x001C_ _x001C_
Condition: Unknown
Due 6 March 2001
Resolved 28 February 2001
Fire Fighting
Issued 20 February 2001 Resolved
Replace 1 B-II fire extinguisher._x001C_ _x001C_ This item to be corrected prior to carrying passengers for hire._x001C_ _x001C_
Condition: Unknown
Due 6 March 2001
Resolved 28 February 2001
Lifesaving
Issued 20 February 2001 Resolved
Provide 6 orange smoke flares._x001C_ _x001C_ This item to be corrected prior to carrying passengers for hire._x001C_ _x001C_
Condition: Unknown
Due 6 March 2001
Resolved 28 February 2001
Lifesaving
Issued 16 February 1999 Resolved
Replace retro-tape on lifefloat.
Condition: Unknown
Due 16 February 1999
Resolved 16 February 1999
Lifesaving
Issued 16 February 1999 Resolved
Replace weak-link on life float.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Lifesaving
Issued 16 February 1999 Resolved
Provide logbook & log monthly lifesaving/EPIRB checks - quarterly emergencydrills.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Lifesaving
Issued 16 February 1999 Resolved
Provide proper flare container.
Condition: Unknown
Due 16 February 1999
Resolved 16 February 1999
Fire Fighting
Issued 22 February 1997 Resolved
REPLACE 2 B-I FIRE EXTINGUISHERS WITH 2 B-II EXTINGUISHERS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 1 March 1997
Resolved 4 March 1997
Fire Fighting
Issued 31 January 1995 Resolved
Replace fire extinguisher brackets for B-II fire extinguishers.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Documentation
Issued 31 January 1995 Resolved
Provide evidence of a personal radio license for Master on vessel.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Accommodation/Occupational Safety
Issued 31 January 1995 Resolved
Install a shut off valve for the overboard discharge on the Marine Sanitation Device.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Construction/Loadline
Issued 12 February 1994 Resolved
COMPLETE ALL TESTS REQUIRED ON HULL LAYUP AS PRESCRIBED IN MSC LTR. PROVIDE RESULTS TO ATTENDING CG MARINE INSPECTOR NO LATER THAN 12MAY94.
Condition: Unknown
Due 12 February 1994
Resolved 12 February 1994

Ownership record