MAURY USCG vessel records Sign in
← All vessels

PIRATES RANSOM

PIRATES RANSOM is a 1994 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1993, most recently in March 2026, along with 67 deficiencies and 1 casualty investigation in 2011.

Records from 1993 to 2026. Most recent: inspection, 12 March 2026.

Built
1994
Last inspected
12 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCJ6202
401969
Flag
UNITED STATES
366942430
Maury page id
psix-401969

Inspections, by type

…with no type recorded3
Years with a record 32 calendar years (1993–2026)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)55.5 ft × 20.0 ft × 9.0 ft
Registered tonnagegross 66 / net 53
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDUCKWORTH STEEL BOATS INC · TARPON SPRINGS, FL, UNITED STATES · built 1994
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCLEARWATER, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Simplified, Gross Ton
53 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCJ6202MMSI 366942430 · active · compulsorily equipped · granted 25 April 2024, expires 13 July 2034
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 65

12 March 2026 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8316584
25 August 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8217204
27 January 2025 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8059383
12 December 2024 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8040619
18 January 2024 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7841341
1 November 2023 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7807630
8 May 2023 Deficiency Check · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7671031
10 January 2023 COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7613779
9 December 2022 Examination of Repairs · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7571602
4 February 2022 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7380510
1 December 2021 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7359246
14 September 2021 Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7323635
4 January 2021 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7119363
13 January 2020 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6860293
21 August 2019 Hull Examination · Examination of Repairs · Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6791348
6 February 2019 DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6610387
17 January 2018 DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6332976
13 November 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6305766
23 January 2017 Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6067089
26 January 2016 DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5804178
2 December 2015 Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5772036
30 January 2012 Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4234216
1 January 2012 Damage Survey · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4216755
31 December 2011 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4218063
1 December 2011 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4198691
21 September 2011 Inclining Experiment · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4151382
18 January 2011 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3932828
2 December 2010 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3904945
2 February 2010 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3674241
9 January 2009 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3391366
11 December 2008 Examination of Repairs · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3381076
22 January 2008 COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3134058
5 February 2007 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2866978
6 February 2006 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2579793
10 February 2005 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2289634
7 January 2005 Internal Structural Exam · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2270065
29 January 2004 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1996091
12 December 2003 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1958085
13 February 2003 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1765806
23 January 2003 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1733699
25 March 2002 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1599862
29 January 2002 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1481870
12 December 2001 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1440613
6 March 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1058932
1 February 2001 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1460493
14 March 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 226746
3 February 2000 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1391257
7 December 1999 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1391212
26 January 1999 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1416953
19 January 1998 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1390732
9 December 1997 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1390731
24 February 1997 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1445251
23 April 1996 Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 873131
27 March 1996 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1077775
25 March 1996 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1083451
1 February 1996 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1371281
13 March 1995 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 960407
21 December 1994 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 861422
25 October 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 868484
20 July 1994 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1175176
28 April 1994 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1168557
15 March 1994 Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 856590
25 August 1993 Initial Construction-Excluding Oversight
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1395979
8 June 1993 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 845958
3 May 1993 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1139483

Deficiency record · 67

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 March 2026 Resolved
Each life jacket must be marked with Type I retro reflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. MI observed that all child size life jackets and multiple adult size life jackets need new retro reflective material. 46 CFR 185.604(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2026
Resolved 25 March 2026
Resolution: Received picture of new retro reflective material on life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 August 2025 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and be capable of operating at constant marine load under such requirements. The main propulsion starter engaged with no prompt and could not be stopped until battery power was secured. A marine electrician must troubleshoot the start system to determine the root cause and make repairs to the satisfaction of the Coast Guard. This must be completed prior to carrying passengers. 46 CFR 182.200
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2025
Resolved 27 August 2025
Resolution: Repairs were made.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 January 2025 Resolved
All electrical installations shall be to the satisfaction of the [name withheld] observed missing outlet cover near operating station and open junction box located near forward mast. 46CFR183.01-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2025
Resolved 12 February 2025
Resolution: Outlet cover and junction box replaced/closed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 January 2025 Resolved
All electrical installations shall be to the satisfaction of the [name withheld] observed generator control panel in engine room not properly mounted and new gauges not properly wired. 46CFR183.01-15
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2025
Resolved 25 February 2025
Resolution: Photographic evidence received of control panel in engine room properly mounted and wired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 May 2023 Resolved
Flexible or portable cords such as SO, STO, and similar types cannot be used for permanently installed wiring. Marine Inspector observed 02 portable cables being utilized as permanent installations within the engine room, including one being used for an emergency bilge pump. 46 CFR 183.10-20(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 22 May 2023
Resolution: Vessel sent email correspondence indicating that the outlet will no longer be used for an emergency bilge pump arrangement. Vessel POC purchased a high end shop vac, which will be used in an as needed fashion.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 May 2023 Resolved
Each door, hatch, or scuttle used as a means of escape, must be capable of being opened by one person, from either side, in both light and dark conditions. Marine inspector observed a fire escape hatch leading from the bar area to the second deck that was inoperable. 46 CFR 177.500(h)
Action required: 10 - Deficiency Rectified
Due 8 May 2023
Resolved 8 May 2023
Resolution: Crew removed file/grinded down expanded rust around trunk opening allowing hatch to be open/closed satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 May 2023 Resolved
In systems and applications where flexible hoses are permitted to be clamped, two clamps must be used on each end of the hose. Marine inspector observed water intake flexible hose on stbd generator was missing 01 clamp. 46 CFR 182.410(d)(4)
Action required: 10 - Deficiency Rectified
Due 8 May 2023
Resolved 8 May 2023
Resolution: Crew attached additional hose clamp to generator raw water intake hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 January 2023 Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. MI observed bilge piping in second compartment aft (fwd hold) was clogged, preventing full rate of suction from the space. 46 CFR 182.25-5(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 12 January 2023
Resolution: Replaced clogged bilge piping. Created maintenance plan to test all bilge piping monthly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 January 2023 Resolved
Penetrations and openings in watertight bulkheads must - have means to make them watertight. MI observed hole for cabling, located in the upper starboard side of the collision bulkhead, that was not watertight. 46 CFR 171.114(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 22 January 2023
Resolution: Vessel rep made penetration watertight
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 January 2023 Resolved
It is intended that all machinery be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. MI observed high water level alarm for the second compartment aft (fwd hold) provided an audible alarm, but no visual alarm at the operating station. 46 CFR 182.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 30 January 2023
Resolution: New alarm panel installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 January 2023 Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q, or other standard specified by the Commandant. MI observed grab line on the ring life buoy was deteriorated due to exposure/UV damage. 46 CFR 180.70(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 20 January 2023
Resolution: New ring buoy installed.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 10 January 2023 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. MI observed belt on starboard engine was missing a guard. 46 CFR 177.35-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 26 January 2023
Resolution: New guard installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2023 Resolved
It is intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, mechanical failure, and personnel injury. MI observed temperature sensor on the port generator was disconnected. 46 CFR 182.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 26 January 2023
Resolution: Installed new sensor.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 January 2021 Resolved
Deficiency Code: 18429 At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Marine Inspector found amounts of oil residue in various locations identified to the vessel owner and rep, conduct proper maintenance to the satisfaction of attending [name withheld]: 46 CFR 176.830(b) Action: 16 Action Code: c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2021
Resolved 5 February 2021
Resolution: Owner/operator submitted pictures to verify oil and additional residues that had been cleaned and cleared from engine room bilge.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 January 2020 Resolved
A vessel must comply with the applicable requirements for any radio including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Input GPS coordinates into VHF radio. 46CFR184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 31 January 2020
Resolution: VHF radio was equipped with GPS coordinates.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 January 2020 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Reduce oil leak on starboard engine. 46CFR182.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 31 January 2020
Resolution: Oil leak repaired, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 February 2019 Resolved
Provide proof of supervisor and employee EAP training. Owner could not provide proof of training. 46 CFR 16.401
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2019
Resolved 22 February 2019
Resolution: Verified operator completed required training.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 February 2019 Resolved
Company drug testing policy not in place. Provide proof employees have read and signed the company drug testing policy. 46 CFR 16.401
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2019
Resolved 22 February 2019
Resolution: Verified company has a policy in place.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 January 2017 Resolved
Prove purchase of first aid ammonia inhalants within date of expiration iaw 46CFR184.710.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 3 March 2017
Resolution: Purchased ammonia inhalants.
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 January 2017 Resolved
Provide double hose clamping on engine and generator hoses on cooling systems (port and stbd) iaw 46CFR182.410(d)(1).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 3 March 2017
Resolution: Installed additional hose clamps on cooling systems.
Electrical › Lighting (service) › Lighting Fixture
Issued 23 January 2017 Resolved
Provide proper Marine Type Electric Lighting Fixtures for overhead lights in engine room and lazarette iaw 46FR183.10-20(3)(L).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 3 February 2017
Resolution: Installed proper overhead lights in engine room and lazarette.
Construction/Loadline › Hull › Hull Plating
Issued 3 December 2015 Resolved
Conduct repairs of wasted hull plating in accordance with approved repair proposal IAW 46 CFR 176.700.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2015
Resolved 14 December 2015
Resolution: Verified repairs conducted IAW provided proposal of wasted hull plating.
Construction/Loadline › Hull › Hull Plating
Issued 2 December 2015 Resolved
Provide proposal to make permanent repairs to wasted hull plating on the aft 02 and 03 decks and arrest active rusting areas and repair wasted area in vicinity of bowsprit. IAW 46 CFR 176.700.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 December 2015
Resolved 3 December 2015
Resolution: Vessel representative provided an acceptable repair proposal.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 2 December 2015 Resolved
Renew or repair damaged or missing insulation in the engine room overhead IAW 46 CFR 177.410(c)(4).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2015
Resolved 14 December 2015
Resolution: Acoustic insulation was renewed or repaired in the damaged areas.
Fire Fighting › Fire Pumps › Pressure
Issued 30 January 2012 Resolved
Fire Pump outlet not fitted with working pressure gauge. Replace in kind IAW 46CFR181.300(b).
Due 6 February 2012
Resolved 6 February 2012
Resolution: Replaced with in kind working pressure gauge.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 January 2012 Resolved
Properly dead end wires on port and stbd engines, and in main hold to protect pax and crew IAW 46CFR183.200(b).
Due 6 February 2012
Resolved 6 February 2012
Resolution: Properly dead ended all wires.
Navigation › Piloting/Steering › Marine Charts
Issued 30 January 2012 Resolved
Properly update charts in to one year of this date IAW 46CFR184.420.
Due 13 February 2012
Resolved 6 February 2012
Resolution: Purchased new charts.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 5 February 2007 Resolved
Permanently mount electrical box to STBD generator
Condition: Unknown
Due 5 March 2007
Resolved 7 February 2007
Resolution: Eelectrical box was mounted to the STBD generator and is secure.
Stability › Watertight Integrity › General
Issued 5 February 2007 Resolved
Repack stuffing tube IWO fwd blkhd of #4 compartment
Condition: Improper/Lack of Maintenance
Due 5 March 2007
Resolved 7 February 2007
Resolution: Stuffing tube in FWD bulkhead of #4 compartment has been re-packed as requested to specific guidelines.
Navigation › Piloting/Steering › US Coast Pilot
Issued 6 February 2006 Resolved
Provide U.S. Coast Pilot.
Action required: 705 - Other - as specified
Due 6 March 2006
Resolved 13 March 2006
Resolution: POC PURCHASED A NEW BOOK.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 6 February 2006 Resolved
Provide a C. G. Light List.
Action required: 705 - Other - as specified
Due 6 March 2006
Resolved 13 March 2006
Resolution: POC PURCHASED A NEW LIST
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 6 February 2006 Resolved
Provide Local Notice to Mariners.
Action required: 705 - Other - as specified
Due 6 March 2006
Resolved 13 March 2006
Resolution: POC HAS THEM COMING TO HER E-MAIL ADDRESS
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 6 February 2006 Resolved
Provide Navigation Rules.
Action required: 705 - Other - as specified
Due 6 March 2006
Resolved 13 March 2006
Resolution: POC PURCHASED A NEW BOOK
Lifesaving › Lifefloat › Serviceable
Issued 6 February 2006 Resolved
Make necessary repairs to the life floats or provide the vessel with an FCC approved 406 Mhz EPIRB.
Action required: 705 - Other - as specified
Due 6 March 2006
Resolved 13 March 2006
Resolution: NEW EPIRB IS ONBOARD AND INSTALLED PROPERLY WITH PROPER REGISTRATION AND CERTIFICATES.
Engineering › Bilge Water Management System › Valve
Issued 10 February 2005 Resolved
REPAIR ENGINE ROOM AND #3 VOID BILGE SUCTIONS PRIOR TO CARRIAGE OF PASSENGERS.
Due 17 February 2005
Resolved 11 February 2005
Resolution: REPLACED IN KIND.
Lifesaving › Hand Flares › Expired
Issued 10 February 2005 Resolved
PROVIDE 3 HAND HELD DAY/NIGHT FLARES PRIOR TO CARRIAGE OF PASSENGERS.
Due 17 February 2005
Resolved 10 February 2005
Resolution: CORRECTED ON SPOT.
Communications › Radio Communications
Issued 23 January 2003 Resolved
Provide a FCC Marine Radio Operator Permit for [name withheld] COMPONENT DESC: FCC Operators Permit
Condition: Improper/Lack of Maintenance
Due 23 February 2003
Resolved 13 February 2003
Resolution: Rcv''d copy of computer application for FCC operator permit for Master Graham.
Accommodation/Occupational Safety › Occupational Safety
Issued 23 January 2003 Resolved
Label engine room escape hatch on main deck. LEGACY COMPONENT DESC: Engine Room Escape Hatch
Condition: Improper/Lack of Maintenance
Due 29 January 2003
Resolved 25 January 2003
Navigation › Piloting/Steering
Issued 23 January 2003 Resolved
Prior to operating at night, repair compass light and mount float light for ring life buoy. LEGACY COMPONENT DESC: Compass Light
Condition: Improper/Lack of Maintenance
Due 23 January 2003
Resolved 25 January 2003
Lifesaving › Buoyant Apparatus
Issued 23 January 2003 Resolved
Replace two painter lines on life floats as discussed. LEGACY COMPONENT DESC: Painter
Condition: Improper/Lack of Maintenance
Due 23 January 2003
Resolved 25 January 2003
Navigation
Issued 29 January 2002 Resolved
Provide local area Navigation Chart
Condition: Unknown
Due 1 March 2002
Resolved 25 March 2002
Resolution: CHART PROVIDED.
Lifesaving › Lifebuoys
Issued 29 January 2002 Resolved
Attach waterlight to lifering with 3-6 foot of floating, UV resistant line and corrosion resistant clip. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper Installation
Due 1 March 2002
Resolved 25 March 2002
Resolution: CORRECTED.
Lifesaving › Rescue Boat
Issued 29 January 2002 Resolved
Attach floating waterlight on middle liferaft with Floating line.
Condition: Unknown
Due 1 March 2002
Resolved 25 March 2002
Resolution: CORRECTED
Lifesaving
Issued 1 February 2001 Resolved
DEMONSTRATE ABILITY TO RETRIEVE HELPLESS PERSON FROM THE WATER.
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Fire Fighting
Issued 1 February 2001 Resolved
INSTALL VENT CLOSURES FOR ENGINE ROOM VENTS.
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Engineering
Issued 26 January 1999 Resolved
RE-MARK DIRECTION OF CLOSURE ON FUEL OIL EMEGENCY SHUT-OFF VALVE.
Condition: Unknown
Due 30 August 1999
Resolved 30 August 1999
Lifesaving
Issued 26 January 1999 Resolved
REPLACE PAINTER FOR LIFEFLOAT.
Condition: Unknown
Due 30 August 1999
Resolved 30 August 1999
Documentation
Issued 19 January 1998 Resolved
PROVIDE COPY OF MIS REPORT
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Lifesaving
Issued 19 January 1998 Resolved
PROCURE C.G. APPROVED, OR EQUIVALENT, FIRST AID KIT.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Electrical
Issued 9 December 1997 Resolved
INSTALL METALLIC SUPPORTING CLIPS AT LEAST EACH 24" FOR ELECTRIC WIRING ANDHYDRAULIC CONTROL LINES IN E/R, FUEL TANK VOID, AND STEERING COMPT.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Construction/Loadline
Issued 9 December 1997 Resolved
REPLACE HANDLES ON SEA-VALVES FOR BOTH P&S MDE RAW WATER INTAKES.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Fire Fighting
Issued 9 December 1997 Resolved
INSTALL FLAME SCREENS IN SEWAGE TANK VENTS.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Electrical
Issued 9 December 1997 Resolved
PROCURE DI-ELECTRIC MAT FOR DECK ADJACENT TO MAIN SWITCHBOARD.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Lifesaving
Issued 24 February 1997 Resolved
REPLACE BATTERIES IN ALL WATERLIGHTS.
Condition: Unknown
Due 3 March 1997
Resolved 27 February 1997
Fire Fighting
Issued 24 February 1997 Resolved
PROVIDE REPLACEMENT BRACKETS (2) FOR B-II FIRE EXTINGUISHERS.
Condition: Unknown
Due 3 March 1997
Resolved 27 February 1997
Lifesaving
Issued 23 April 1996 Resolved
REPAIR BUBBLING IN LIFE FLOAT OUTER COVER.
Condition: Unknown
Due 3 May 1996
Resolved 23 August 1996
Lifesaving
Issued 23 April 1996 Resolved
REPAIR OR REPLACE WATERLIGHTS. VESSEL RESTRICTED TO DAYLIGHT OPERATIONS UNTIL CORRECTED.
Condition: Unknown
Due 3 May 1996
Resolved 23 August 1996
Lifesaving
Issued 23 April 1996 Resolved
REPAIR OR REPLACE RING BUOYS.
Condition: Unknown
Due 3 May 1996
Resolved 23 August 1996
Engineering
Issued 23 April 1996 Resolved
REINSTALL FUEL FILTER FLAME SHIELD, PORT ENGINE & GENERATOR.
Condition: Unknown
Due 3 May 1996
Resolved 23 August 1996
Construction/Loadline
Issued 23 April 1996 Resolved
PLUG OPEN STUFFING TUBE ENGINEROOM AFT BULKHEAD.
Condition: Unknown
Due 3 May 1996
Resolved 23 August 1996
Engineering
Issued 1 February 1996 Resolved
INSTALL LAGGING AROUND EXPOSED SECTIONS OF ENGINE EXHAUST PIPING.
Condition: Unknown
Due 7 February 1996
Resolved 25 March 1996
Construction/Loadline
Issued 1 February 1996 Resolved
INSTALL POSITIVE CLOSURE VALVE IN GREY WATER DRAIN IN WAY OF THROUGH HULL FITTING IN TRANSOM.
Condition: Unknown
Due 7 February 1996
Resolved 25 March 1996
Documentation
Issued 15 March 1994 Resolved
Provide on board original Certificate of Documentation.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Documentation
Issued 15 March 1994 Resolved
Provide on board emergency check off list prior to carrying passengers.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Documentation
Issued 15 March 1994 Resolved
Post on board valid Stability letter.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Engineering
Issued 15 March 1994 Resolved
Repair tacometer for starboard engine at steering station.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Documentation
Issued 15 March 1994 Resolved
Provide on board valid FCC certificate. Vessel restricted to 1000 feet from shore until satisfied.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994

Casualty record · 1

31 December 2011Routine · role: Involved in a Marine Casualty · activity 4218063
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.