Records from 2003 to 2026. Most recent: inspection, 23 June 2026.
Inspection history · 107
23 June 2026
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8413611
9 March 2026
COI Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8314897
18 December 2025
Re-Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8276856
8 September 2025
Re-Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8229431
5 June 2025
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8155430
11 March 2025
COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8091718
21 November 2024
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8038045
5 September 2024
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7996854
13 June 2024
Administrative Inspection · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7958635
25 March 2024
COI Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7874955
25 March 2024
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7889984
19 March 2024
Deadweight Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7889978
16 January 2024
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7849778
14 December 2023
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7834408
7 September 2023
MTSA Verification · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7786881
30 August 2023
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7781198
14 June 2023
Administrative Inspection · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7714918
11 May 2023
Annual Inspection · Annual Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7685774
28 April 2023
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7680774
8 February 2023
Deficiency Check · Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7633971
23 January 2023
Administrative Inspection · Plan Review (Other than "T")
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7626383
21 December 2022
Deficiency Check · Re-Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7611776
17 October 2022
Plan Review (Other than "T") · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7579390
7 September 2022
Administrative Inspection · MTSA Verification · MARPOL Annex VI Survey · Re-Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7553435
18 August 2022
MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7537237
15 June 2022
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7478214
17 May 2022
Deficiency Check · Construction Oversight · Plan Review (Other than "T") · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7452825
12 May 2022
Administrative Inspection · Plan Review (Other than "T") · Examination of Repairs
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7449124
6 April 2022
Deficiency Check · Administrative Inspection · In-Service Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7425632
23 March 2022
Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7433757
3 March 2022
MTSA Verification · Administrative Inspection · COI Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7404935
18 January 2022
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7381796
16 November 2021
MTSA Verification · Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7351821
20 October 2021
Administrative Inspection · Plan Review (Other than "T")
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7337053
14 September 2021
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7302750
7 July 2021
Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7249605
16 June 2021
Re-Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7231534
20 April 2021
Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7231529
9 March 2021
MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7159145
1 December 2020
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7104778
9 September 2020
Re-Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7231525
25 June 2020
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6986698
8 June 2020
Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6971484
21 April 2020
Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6942030
21 April 2020
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6942040
19 March 2020
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6929108
14 March 2020
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6927400
13 March 2020
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6925917
22 January 2020
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6895515
8 January 2020
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6885475
23 December 2019
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6881152
9 December 2019
Administrative Inspection · Re-Inspection · MARPOL Annex VI Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6868583
18 November 2019
Administrative Inspection · Deadweight Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6858380
18 October 2019
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6837292
2 October 2019
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6826221
18 September 2019
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6813718
16 September 2019
Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6812810
9 September 2019
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7104750
5 September 2019
Administrative Inspection · Plan Review (Other than "T") · Examination of Repairs
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6804387
22 August 2019
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6791306
26 June 2019
Administrative Inspection · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6725065
17 June 2019
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6717498
11 March 2019
Deficiency Check · In-Service Inspection · Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6642314
11 March 2019
Deficiency Check · In-Service Inspection · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6643021
4 February 2019
COI Inspection · MTSA Verification · Administrative Inspection · Deficiency Check · In-Service Inspection · DAPI Audit · Examination of Repairs
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6619520
12 December 2018
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6595562
27 September 2018
Administrative Inspection · MARPOL Annex VI Survey · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6550704
14 June 2018
MARPOL Annex VI Survey · Deficiency Check · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6445179
9 April 2018
In-Service Inspection · Plan Review (Other than "T")
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6390167
3 April 2018
Plan Review (Other than "T") · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6383934
2 April 2018
In-Service Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6393046
21 March 2018
MARPOL Annex V Examination · MTSA Verification · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6367529
27 February 2018
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6363148
20 February 2018
Examination of Repairs · Plan Review (Other than "T") · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6390141
5 January 2018
Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6333041
14 December 2017
Re-Inspection · MTSA Verification · MARPOL Annex VI Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6325801
31 October 2017
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6299493
13 October 2017
Administrative Inspection · In-Service Inspection · Plan Review (Other than "T") · Construction Oversight
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6297357
2 October 2017
Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6279590
27 September 2017
MTSA Verification · Administrative Inspection · Annual Inspection · Spot Check · MARPOL Annex VI Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6276487
12 July 2017
Spot Check · Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6206497
4 July 2017
Deficiency Check · Plan Review (Other than "T") · Welding Related Inspections Qualification Testing · Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6206626
28 June 2017
MARPOL Annex VI Survey · Administrative Inspection · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6190422
22 June 2017
Administrative Inspection · Examination of Repairs · Plan Review (Other than "T")
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6183042
13 April 2017
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6123429
4 April 2017
Spot Check · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6117374
21 March 2017
Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6108739
6 March 2017
Administrative Inspection · Spot Check · Examination of Repairs · Plan Review (Other than "T")
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6128755
6 February 2017
Examination of Repairs · Administrative Inspection · Welding Related Inspections Qualification Testing · Spot Check · Plan Review (Other than "T") · Damage Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6093168
19 January 2017
MTSA Verification · Deficiency Check · COI Inspection · Spot Check · MARPOL Annex VI Survey · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6073567
14 December 2016
Plan Review (Other than "T") · Examination of Repairs · Administrative Inspection · Construction Oversight · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6058913
14 December 2016
Spot Check · Re-Inspection · MARPOL Annex VI Survey · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6059041
6 October 2016
Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6020089
30 September 2016
Spot Check · Plan Review (Other than "T") · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6020648
14 September 2016
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6000681
1 September 2016
Deficiency Check · Administrative Inspection · Spot Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5989539
29 August 2016
Plan Review (Other than "T") · Spot Check · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5986195
20 August 2016
Deficiency Check · Examination of Repairs · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6004364
14 July 2016
Spot Check · MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5957006
22 June 2016
Special · Re-Inspection · Deficiency Check · Spot Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5914159
14 June 2016
Administrative Inspection · Special
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5916631
25 May 2016
Administrative Inspection · Examination of Repairs · Damage Survey · Plan Review (Other than "T")
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5886526
25 May 2016
Spot Check · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5888244
26 April 2016
Spot Check · Damage Survey · Administrative Inspection · Plan Review (Other than "T") · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5881927
29 March 2016
Examination of Repairs · Plan Review (Other than "T")
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5858452
11 February 2016
Deficiency Check · MARPOL Annex VI Survey · COI Inspection · DAPI Audit · Spot Check · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5813471
8 January 2016
Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5797417
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 March 2025
Resolved
The emergency generator room time delay did not function as designed. Replace/repair delay to function as required.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2025
Resolution: Witnessed proper operation of time delay.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 January 2024
Resolved
Within 24 hours of the Peoria, Illinois River Gauge reaching the 18’ gauge mark and absent any hazardous weather conditions (i.e. ice), the vessel will get underway in the navigation channel to conduct drills and verify proper operation of machinery to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 31 March 2024
Resolved 9 April 2024
Resolution: Vessel got U/W and verified proper operation of propulsion machinery and cunducted drills.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 23 March 2022
Resolved
Prove proper operation of the ECR rudder angle indicator.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2022
Resolved 6 April 2022
Resolution: Repaired
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 March 2022
Resolved
Ensure the 3rd and 4th decks type 1 pfds have serviceable reflective tape on them.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2022
Resolved 21 December 2022
Resolution: Replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 June 2020
Resolved
Prove the proper operation of the remote manual closure device for both class three watertight doors in the hold deck. During the deadship testing, it was observed that the remote manual closure device requires a crewmember to hold the directional valve at the door to operate, negating the purpose of a remote closure. Vessel may not get underway from the dock prior to correcting deficiency.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2020
Resolved 10 August 2020
Resolution: system was reconfigured to work as manufacturer intended. All sat
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 30 March 2020
Resolved
Provide report of annual servicing for all fire suppression/detection systems including portable fire extinguishers, fixed fire suppression systems, fixed fire detection systems, and 3rd/4th deck sprinkler system, prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2020
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 30 March 2020
Resolved
Repair or replace the inoperative general alarm klaxon in the 4th deck VIP lounge. The bell type klaxon did not make any noise during the operational test. Klaxon must function as designed prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2020
Resolution: Klaxon replaced with new one.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 30 March 2020
Resolved
New communications wire run cableway between hold deck and main deck must meet applicable fire load rating of A-60 prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2020
Resolution: Sufficient RoxTec blocking installed in penetration.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 22 January 2020
Resolved
The unused ventilation duct penetrating the 2nd deck slot managers office inboard facing bulkhead is not fitted with any means of closure. Either install a ventilation damper complying with 46 CFR 72.05-50(i) or have a bulkhead insert welded in and insulated to comply with the A-30 boundary requirements.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2020
Resolved 3 February 2020
Resolution: All repairs completed to include insert, one angle frame, and new structural insulation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 December 2019
Resolved
Replace the missing fire ax placard on the Emergency Generator Room door.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 23 December 2019
Resolution: Placard replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2019
Resolved
Replace the low oil pressure safety sensor on the B/T, the safety is alarming outside of the manufacturer's parameters.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 23 December 2019
Resolution: Oil pressure sensor replaced, alarm tested sat, triggered at seven (07) psi
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 December 2019
Resolved
Replace the worn stern, stbd side life ring water light lanyard.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 23 December 2019
Resolution: New line spliced on light to ring
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 December 2019
Resolved
Ensure the vessel stern life ring lines are not secures to the vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 23 December 2019
Resolution: Ring buoy lifelines disconnected from vessel
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 December 2019
Resolved
Ensure the vessel operator's are familiar with the operation of the AIS system and determine the reason the target vessel names are not appearing on the AIS.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 23 December 2019
Resolution: Vessel master able to correct AIS setting to display vessels in range and familiarized with AIS operation functions
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 9 December 2019
Resolved
Update the vessel's electrical lock out log.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 23 December 2019
Resolution: Chief engineer reviewed all open entries in lock out tag out log, corrected items closed out, log is up to date at this time
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 December 2019
Resolved
Repair or replace the stbd rescue boat 360* navigational light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 23 December 2019
Resolution: Vessel crew serviced portable all around white light, light was properly functioning at time of inspection
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 December 2019
Resolved
Replace the retro on 68 PFD's, the existing retro was previously replaced and was coming loose
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 23 December 2019
Resolution: Retro replaced on pfd's with new SOLAS approved retro tape
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 2 October 2019
Resolved
Prove proper operation of port rescue boat engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2019
Resolved 7 October 2019
Resolution: Rescue boat had fuel gelled in tanks. Emptied and cleaned tank. refilled with fresh fuel and demonstrated operation underway.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 2 October 2019
Resolved
Prove proper operation of the STBD rescue boat navigation lights. Install a temporary until navigation lights
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2019
Resolved 7 October 2019
Resolution: Repaired installed navigation lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2019
Resolved
Repair bow thruster engine exhaust leak.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2019
Resolved 18 October 2019
Resolution: C/E replaced older crush gasket that wasn't sealing on the flex bellows.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 October 2019
Resolved
Vessel must route temporary welding power supply to limit electrical hazards in accordance with 46CFR Subchapter J.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2019
Resolved 7 October 2019
Resolution: Installed cover over power supply.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 July 2019
Resolved
Prove proper operation of the port generator load shed.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 18 July 2019
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 30 April 2019
Resolved
Prior to 01Septemeber2019, ensure the missing port generator keel cooler anode is replaced.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2019
Resolved 17 September 2019
Resolution: replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 March 2019
Resolved
Replace the worn retro of 66 PFD’s.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2019
Resolved 15 March 2019
Resolution: Retro replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 12 March 2019
Resolved
Replace the forward small boat sling attachment U-bolt. The U-bolt is not long enough and the nuts are only threaded on approximately half way.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2019
Resolved 15 March 2019
Resolution: Longer u-bolt installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 March 2019
Resolved
Prove proper operation of the port generator.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2019
Resolved 18 July 2019
Resolution: Gen was propely tested and operating.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 March 2019
Resolved
Prove proper operation of the STBD SSG. Generator is currently non-operational do to a ground issue. The generator will require rewinding by an outside vender.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2019
Resolved 26 June 2019
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 11 March 2019
Resolved
Vessel personnel will immediately evacuate all passengers upon loss of shore power. SUMR Command Center will be promptly notified should this situation occur.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2019
Resolved 18 June 2019
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 11 March 2019
Resolved
Master shall ensure that the vessel has adequate additional manning and lighting, as necessary, to safely evacuate all the passengers upon loss of shore power.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2019
Resolved 18 June 2019
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 11 March 2019
Resolved
Because the service elevator is not under emergency power, ensure that no personnel are transported in this elevator until a SSG is reinstalled and functioning. Cargo may be transported without personnel.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2019
Resolved 18 June 2019
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 21 March 2018
Resolved
Replace the old CO2 type (B-II) portable fire extinguishers with U/L approved 2-A's in the gamming areas, slot office supplies, and the port pontoon room as per table 46CFR76.50-10(a), ensure the vessel's fire control plan is permanently updated.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2018
Resolved 14 June 2018
Resolution: Completed
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 21 March 2018
Resolved
Prove proper closing of the second deck stern, fire screen door.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2018
Resolved 21 March 2018
Fire Fighting › Means of Escape › Escape Route Signs
Issued 21 March 2018
Resolved
Install directional open arrows on the escape scuttles.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2018
Resolved 21 March 2018
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 21 March 2018
Resolved
Replace the deteriorated reto on 28 PFD’s (resolved)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2018
Resolved 21 March 2018
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 14 December 2017
Resolved
Renew the damaged reto on the 56 third deck PFD’s that were identified and set aside.
Condition: Improper Installation
Due 14 January 2018
Resolved 5 January 2018
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 14 December 2017
Resolved
Prove proper operation of vent closures #312 and 303, the closures shut but didn’t reopen all the way.
Condition: Improper/Lack of Maintenance
Due 14 January 2018
Resolved 5 January 2018
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 27 September 2017
Resolved
Verify proper latching of the 3rd deck, aft, port exterior door. The door closed but didn’t latch.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 3 October 2017
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 27 September 2017
Resolved
Verify proper operation of F/S door #11. The door did not close, the latch appeared to hang up on the carpet.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 3 October 2017
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 27 September 2017
Resolved
Ensure the new retro on the PFD’s, which had previously been replaced, is CG or SOLAS approved.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 31 October 2017
Lifesaving › Lifebuoys › Approval
Issued 27 September 2017
Resolved
Replace or prove the vessel’s life rings are CG approved (the approval numbers are worn off).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 31 October 2017
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 27 September 2017
Resolved
Prove proper operation of vent closure #225.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 3 October 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 September 2017
Resolved
Secure the loose wires in the overhead of the stbd pontoon room.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 3 October 2017
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 27 September 2017
Resolved
Replace or repair the damaged structural insulation inside the cart cage.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 3 October 2017
Lifesaving › Rescue Boat Equipment › Electric Torch
Issued 27 September 2017
Resolved
Install a 360* white navigational light on the stbd rescue boat.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 31 October 2017
Lifesaving › Launching Appliances › Davit
Issued 4 July 2017
Resolved
Repair the failed (fractured) port rescue boat davit vertical support pipe.
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 17 July 2017
Fire Fighting › Automatic Sprinkler System › Piping
Issued 28 June 2017
Resolved
Properly repair the broken bolt flange retaining clip on the sprinkler pump housing. The sprinkler pump is still operational.
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 21 August 2017
Resolution: Replaced
Electrical › Electric Generation Source (service) › Generator
Issued 28 June 2017
Resolved
Ensure proper operation of the stbd generator reverse power relay (RPR).
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 12 July 2017
Lifesaving › Rescue Boat › Propulsion Engine
Issued 4 April 2017
Resolved
Prove proper operation of the port rescue boat engine.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 28 April 2017
Resolution: Repaired
Navigation › Collision/Grounding Avoidance › Radar
Issued 4 April 2017
Resolved
2. Determine the reason the RADAR shuts down when the G/A bell is sounded while operating on E-power and repair as necessary. This problem does not exist while operating on normal ships power.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 14 April 2017
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 15 March 2017
Resolved
Prove proper operation of the bridge main console stbd shaft RPM gauge.
Condition: Improper/Lack of Maintenance
Due 17 April 2017
Resolved 14 April 2017
Engineering › Compressed Air System (start air) › Valve
Issued 15 March 2017
Resolved
Replace the broken air system pressure gauge
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 21 March 2017
Resolution: new gauge installed
Lifesaving › Launching Appliances › Winch
Issued 14 December 2016
Resolved
Prove proper operation of the stbd rescue boat winch. The winch failed (stop) when the boat was being placed back in the cradle. After that, the winch motor operated erratically but is not dependable.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 January 2017
Resolved 9 January 2017
Resolution: The cause of the initial failure was never verified. The winch has operated properly ever since.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 14 December 2016
Resolved
Prove proper operation of the 3nd deck vent closure (port side forward).
Condition: Invalid
Due 14 January 2017
Resolved 15 December 2016
Resolution: Motor replaced.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 December 2016
Resolved
Replace one damaged PFD in the third deck locker or reduce the locker count. The vessel maintains an excess amount of PFD's so the COI passenger count is not affected.
Condition: Improper/Lack of Maintenance
Due 14 January 2017
Resolved 15 December 2016
Resolution: PFD replaced.
Fire Fighting › Automatic Sprinkler System › Pump
Issued 14 September 2016
Resolved
Ensure proper operation of the sprinkler system jockey pump.
Condition: Damaged By Earlier Event
Due 28 September 2016
Resolved 20 September 2016
Resolution: Piping system flushed
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 September 2016
Resolved
Ensure the life ring, strobe lights have the proper batteries installed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 September 2016
Resolved 14 September 2016
Resolution: The proper batteries were installed.
Fire Fighting › Fire Main › Valves
Issued 1 September 2016
Resolved
Repair the leaking fire main riser valve, stbd stern location.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2016
Resolved 14 September 2016
Electrical › Lighting (emergency) › Lighting Fixture
Issued 1 September 2016
Resolved
Ensure proper operation of the port boat davit light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2016
Resolved 14 September 2016
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 1 September 2016
Resolved
Adjust the EOS, stbd, shaft, RPM gauge, it is operating approx 100 rpm slow.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2016
Resolved 20 September 2016
Lifesaving › Rescue Boat › Propulsion Engine
Issued 20 August 2016
Resolved
Prove proper operation of the port rescue boat, the priming bulb is cracked and will not prime.
Due 30 September 2016
Resolved 6 October 2016
Resolution: Witnessed proper operation of PORT rescue boat engine.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 20 August 2016
Resolved
Prove proper operation of the 2nd deck vent closures, #207, 213 and 225. The vents close but do not open up very much.
Due 30 September 2016
Resolved 6 October 2016
Resolution: Witnessed proper operation of all three 2nd deck vent closures.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 20 August 2016
Resolved
Properly adjust (one dogg was dragging on the top of the ladder rail) and label (open direction arrow) the G/R and E/R escape scuttles. The scuttles still function.
Due 30 September 2016
Resolved 6 October 2016
Resolution: Escape hatch was properly labled with directional arrows as well as indicators to line up for proper replacement of scuttle hatch.
Operations/Management › Vessel Activity › Underway
Issued 23 June 2016
Resolved
Within 24 hours of the Peoria, Illinois River Gauge reaching the 18’ gauge mark and absent any hazardous weather conditions (i.e. ice), the vessel will get underway in the navigation channel to conduct drills and verify proper operation of machinery to the satisfaction of the attending Marine Inspector. The vessel’s next underway date will remain 30JUNE2017.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 September 2016
Resolution: Vessel got U/W
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 June 2016
Resolved
Properly repair and or adjust the aft (1st-3rd deck) stern fire screen doors.
Condition: Improper/Lack of Maintenance
Due 5 August 2016
Resolved 29 August 2016
Resolution: The door was replaced.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 16 March 2016
Resolved
Repair or replace the fire detection system, probe type, HAD support bracket, located over the inboard generator. The HAD was tested and still functions.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 14 April 2016
Resolution: Replaced
Lifesaving › Rescue Boat › Hull (rigid)
Issued 16 March 2016
Resolved
Repair the fracture in the port rescue boat upper stbd bow area. Fracture is above the waterline at the deck edge (gunwale).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 4 April 2016
Resolution: The hull was welded