Records from 1994 to 2022. Most recent: inspection, 18 August 2022.
Inspection history · 45
18 August 2022
In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7537346
11 March 2009
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3439485
4 February 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3412406
8 July 2008
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3261883
22 April 2008
COC-MODU Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3207056
25 January 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3136250
19 March 2007
COC-MODU Renew
Type not classified · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3132064
23 March 2006
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2608969
18 October 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2516709
17 October 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2516386
23 September 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2510035
28 March 2005
COC-MODU Renew
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2321618
28 February 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2352801
13 April 2004
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2043128
9 March 2004
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2016636
24 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1762279
26 February 2003
MARPOL Annex I Examination · MARPOL Annex V Examination · Certificate of Compliance
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1750203
14 June 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1630909
17 November 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1076152
7 November 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1630881
8 September 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073280
7 March 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1436525
1 August 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 820838
14 March 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399325
22 September 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1036754
26 May 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 800879
22 March 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449152
2 February 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 790418
19 January 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 815081
16 November 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803479
1 April 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451281
11 April 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1378016
17 April 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1392439
1 March 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 884934
22 December 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 873810
30 November 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 122800
14 September 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1193257
8 August 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 879928
10 July 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1193082
24 April 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1447444
14 December 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 837248
5 October 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 862156
4 August 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 866683
17 June 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1020353
25 April 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468313
Fire Fighting › Structural - A Class Divisions › Special Category Spaces
Issued 19 March 2007
Resolved
Complete satisfactory repairs to the wasted bulkhead between the mud pit room and the upper processing room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 June 2007
Communications › Visual Communication › Red Warning Signal
Issued 19 March 2007
Resolved
Complete repairs to and prove proper operation of engine room general alarm beacon.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 April 2007
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 19 March 2007
Resolved
Set overspeed trips for #1 and #4 generators to proper RPM.
Condition: Improper/Lack of Maintenance
Due 19 April 2007
Resolved 2 April 2007
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 19 March 2007
Resolved
Provide and properely install correct MCT blocks between water maker room and the electrical switchboard room.
Condition: Improper Installation
Due 19 April 2007
Resolved 2 April 2007
Engineering › Fuel Oil Service System › Gauge
Issued 19 March 2007
Resolved
Renew protective cover around sight glass for fuel oil day tank in the engine room.
Condition: Unknown
Due 19 April 2007
Resolved 2 April 2007
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 March 2007
Resolved
Adjust and prove proper operation of the A class fire door from locker room to exterior deck.
Condition: Improper/Lack of Maintenance
Due 19 April 2007
Resolved 2 April 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 19 March 2007
Resolved
Install proper speaker, for hazardous location, in drillers shack.
Condition: Improper Installation
Due 19 April 2007
Resolved 2 April 2007
Electrical › Electrical Distribution System (service)
Issued 9 March 2004
Resolved
Provide documentation for Flag State satisfaction for removal of bow thrusters and associated wires. LEGACY COMPONENT DESC: Cable
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 April 2004
Resolved 12 April 2004
Resolution: ABS surveyor [name withheld] found wire ends with shrink wrap socks and found arrangement satisfactory provided said wiring is permanently marked and noted at termination as being disabled and out of service.
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 9 March 2004
Resolved
Provide proper size spanner wrenches for all indoor fire stations.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 April 2004
Resolved 23 March 2005
Resolution: Verified that fire stations were equipped with proper spanner wrenches.
Electrical › Electrical Distribution System (service)
Issued 26 February 2003
Resolved
Install approved cap for Class I/Div 1 fitting installed in hydraulic pump controller in pump room. LEGACY COMPONENT DESC: Junction Box
Due 27 February 2003
Resolved 27 February 2003
Resolution: Examined and found satisfactory that electrical fitting meets the requirements for the hazardous location in which it is installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 26 February 2003
Resolved
Properly affix portable fire extinguisher No. 29 in a marine type fire extinguisher to the bulkhead located in the pump room.
Due 27 February 2003
Resolved 27 February 2003
Resolution: Examined and found satisfactory newly installed fire extinguisher with suitable bracket.
Accommodation/Occupational Safety › Ventilation
Issued 26 February 2003
Resolved
Install exhaust fan motor for the pump room and fan closure device. LEGACY COMPONENT DESC: Exhaust Fan Motor & Closure Device
Condition: Unknown
Due 28 February 2003
Resolved 28 February 2003
Resolution: Explosion proof fan motor was installed, operated and found satisfactory. Vent closure was repaired and proven tight.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 26 February 2003
Resolved
Provide and install approved cable packing for electrical cables penetrating bulkhead from pump room to moon pool area to maintain A-Class fire integrity rating
Due 28 February 2003
Resolved 28 February 2003
Resolution: All cable penetrations were renewed with FTP approved/accepted material meeting the fire integrity rating of the bulkhead.
Fire Fighting › Miscellaneous Items
Issued 26 February 2003
Resolved
Properly secure cable for fire alarm pull box located on moon pool deck.
Due 27 February 2003
Resolved 27 February 2003
Resolution: Examined and found satisfactory
Fire Fighting › Miscellaneous Items › B Class Division Penetrations
Issued 26 February 2003
Resolved
Install proper packing for electrical cable run from moon pool deck to port quarters passageway to maintain integrity of boundary.
Due 28 February 2003
Resolved 28 February 2003
Resolution: Examined and found satisfactory.
Electrical › Electric Supply System (service) › Cable
Issued 26 February 2003
Resolved
Remove dead ended cable from port quarters passageway
Due 27 February 2003
Resolved 27 February 2003
Resolution: Examined and found satisfactory cables were removed from power source to prevent any injury to vessel personnel.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 26 February 2003
Resolved
Repair and prove operation of No.2 Generator reverse power relay
Due 28 February 2003
Resolved 28 February 2003
Resolution: Witnessed satisfactory operation of reverse power relay
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 26 February 2003
Resolved
Repair & prove operation of No. 5 and No. 7 Generators prime mover overspeed trips
Due 27 February 2003
Resolved 27 February 2003
Resolution: Witness satisfactory operation of overspeed devices.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 26 February 2003
Resolved
Repair & prove operation of #2, #3, #5, & #7 generators prime mover low lube oil shutdowns LEGACY COMPONENT DESC: Low Lube Oil Shutdowns
Due 27 February 2003
Resolved 27 February 2003
Resolution: Witnessed satisfactory operation of low lube oil shutdowns.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 26 February 2003
Resolved
Repair & prove operation of #5 generator prime mover
Due 27 February 2003
Resolved 27 February 2003
Resolution: Witnessed satisfactory operation of generator prime mover and all safety devices.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 26 February 2003
Resolved
Repair & prove operation of #7 generator prime mover RPM gauge.
Due 27 February 2003
Resolved 27 February 2003
Resolution: Witnessed satisfactory operation of RPM guage.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 26 February 2003
Resolved
Repair fuel oil leak on #7 generator prime mover LEGACY COMPONENT DESC: Fuel Oil System
Due 27 February 2003
Resolved 27 February 2003
Resolution: Examined and found satisfactory newly installed fuel oil piping and fittings.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 26 February 2003
Resolved
Remove all oil and oil residue from generator room bilges.
Due 28 February 2003
Resolved 28 February 2003
Resolution: All bilges were cleaned and all oily mixtures were sent to a shoreside facility for disposal.
Engineering › Fuel Oil Service System › Valve
Issued 26 February 2003
Resolved
Repair and prove operation of emergency generator remote fuel oil shutdown.
Due 27 February 2003
Resolved 27 February 2003
Resolution: Witnessed satisfactory operation of remote shutdown after repairs to the hydraulic activated valve was completed.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 26 February 2003
Resolved
Provide directory of circuits to all electrical distribution panels
Due 28 February 2003
Resolved 28 February 2003
Resolution: Examined and found satisfactory that all electrical distribution panels were providd with a directory of circuits.
Communications › Audible Communications › Horn/Whistle
Issued 26 February 2003
Resolved
Repair and prove operation of automatic fog horn
Due 27 February 2003
Resolved 9 March 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 26 February 2003
Resolved
Remove and replace portable fire extinguisher located next to emergency generator that has been discharged
Due 27 February 2003
Resolved 27 February 2003
Resolution: New portable fire extinguisher installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 26 February 2003
Resolved
Place portable fire extinguisher #79 in its mounting bracket in emergency generator room
Due 27 February 2003
Resolved 27 February 2003
Electrical › Electric Supply System (service) › Battery Charger
Issued 26 February 2003
Resolved
Install missing volt meter to La Marche Constavolt charger located in emergency generator room
Due 27 February 2003
Resolved 4 March 2003
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 February 2003
Resolved
Provide documentation that the newly installed 15 ppm oil content meter meets the has been approved in accordance with resolution A.3939(X).
Due 27 February 2003
Resolved 27 February 2003
Resolution: Sighted documentation that content meter meets the accepted standard.
Stability › Watertight Integrity
Issued 26 February 2003
Resolved
Adjust and prove tightness of quick acting watertight doors to the SCR room.
Due 28 February 2003
Resolved 28 February 2003
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 26 February 2003
Resolved
Install diesel settling tank level float switch that is hanging out of the tank located in the generator room.
Due 28 February 2003
Resolved 28 February 2003
Resolution: Switch was installed in junction box, tested, and found satisfactory.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 26 February 2003
Resolved
Install cover to electrical junction box located on the bulkhead in way of fuel oil purifiers
Due 27 February 2003
Resolved 27 February 2003
Electrical › Electrical Distribution System (service) › Junction Box
Issued 26 February 2003
Resolved
Install cover to eletrical junction box under stair platform in way of generator room fuel/water separator
Due 27 February 2003
Resolved 27 February 2003
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 February 2003
Resolved
Remove batteries from fresh water generator room that are not dedicated to a specific electrical system.
Due 27 February 2003
Resolved 27 February 2003
Engineering › Fuel Oil Service System › Valve, Control
Issued 26 February 2003
Resolved
Prove operation of main generator day tanks fuel oil valves remote shutdowns.
Due 27 February 2003
Resolved 27 February 2003
Resolution: Witnesses satisfactory operation of fuel oil tank remote shutdowns.
Construction/Loadline › Penetrations › Weld
Issued 26 February 2003
Resolved
Repair bulkhead pipe penetrations located in front No. 4 generator to maintain integrity of bulkhead.
Due 28 February 2003
Resolved 28 February 2003
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 26 February 2003
Resolved
Repair water leak to No. 3 generator prime mover in way of expansion tank pipe connection to the engine.
Due 27 February 2003
Resolved 4 March 2003
Resolution: Wasted pipe was renewed and proven tight.
Fire Fighting › Ventilation Systems
Issued 26 February 2003
Resolved
Prove operation of selected fire dampers in the vessels high risk areas to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Dampers
Due 27 February 2003
Resolved 27 February 2003
Resolution: All fire dampers tested were proven operational.
Electrical › Electrical Distribution System (service) › Cable
Issued 26 February 2003
Resolved
Provide adequate cable supports throughout the vessel in lieu of the plastic cable supports presently installed.
Due 27 February 2003
Resolved 25 April 2003
Operations/Management › Pollution › Compliance with Transfer Procedures
Issued 26 February 2003
Resolved
Provide for review oil transfer procedures in accordance with 33 CFR 155.720.
Due 27 February 2003
Resolved 27 February 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 26 February 2003
Resolved
Provide records of oil transfer hose inspection and testing as per 33 CFR 155.820
Due 28 February 2003
Resolved 28 February 2003
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 26 February 2003
Resolved
Provide standard discharge connection
Condition: Unknown
Due 27 February 2003
Resolved 27 February 2003
Operations/Management › Equipment Service/Testing
Issued 26 February 2003
Resolved
Provide documentation attesting to testing of fire detection and gas detection system
Condition: Unknown
Due 27 February 2003
Resolved 27 February 2003
Resolution: Received and reviewed both reports which indicate all systems in satisfactory condition. Conducted spot check & tested sampling of both systems sensors with satisfactory results.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 26 February 2003
Resolved
Install contain plug for diesel transfer station containment
Condition: Improper/Lack of Maintenance
Due 27 February 2003
Resolved 27 February 2003
Lifesaving › Lifebuoys
Issued 26 February 2003
Resolved
Provide weighted ring buoys for the buoys outfitted with smoke located on the weather deck
Due 28 February 2003
Resolved 28 February 2003
Resolution: New ring life buoys were installed.
Lifesaving › Inflatable Liferafts › Markings
Issued 26 February 2003
Resolved
Properly mark all inflatable life raft stations.
Condition: Unknown
Due 27 February 2003
Resolved 27 February 2003
Electrical › Electrical Distribution System (service) › Cable
Issued 26 February 2003
Resolved
Properly pack the electrical cable transit in the air receiver room located directly beneath the emergency diesel generator room.
Due 28 February 2003
Resolved 28 February 2003
Fire Fighting › Structural - A Class Divisions › Aux Spaces (moderate fire risk)
Issued 26 February 2003
Resolved
Properly pack the A and B class wire transits in way of the electrical chase bulkheads behind the laundry and the overhead in way of the doorway leading to the chase.
Due 28 February 2003
Resolved 28 February 2003
Operations/Management › Equipment Service/Testing
Issued 26 February 2003
Resolved
Complete ABS issued work list items 1 through 19 issued 2/26/03.
Due 28 February 2003
Resolved 28 February 2003
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 26 February 2003
Resolved
Provide documentation attesting to internal examination of all pressure vessels within prescribed intervals.
Due 27 February 2003
Resolved 27 February 2003
Accommodation/Occupational Safety › Ventilation
Issued 19 February 2003
Resolved
Demonstrate operation of loss of ventilation alarm in mud pit room LEGACY COMPONENT DESC: Loss of Ventilation Alarm
Action required: 705 - Other - as specified
Due 27 February 2003
Resolved 27 February 2003
Resolution: Witnessed satisfactory operation of loss of ventilation alarm
Communications › Alarms/Indicators
Issued 19 February 2003
Resolved
Demonstrate operation of general alarm system. LEGACY COMPONENT DESC: General Alarm
Action required: 705 - Other - as specified
Due 27 February 2003
Resolved 27 February 2003
Resolution: Witnessed satisfactory operation of general alarm system throughout the vessel.
Communications › Alarms/Indicators
Issued 19 February 2003
Resolved
Demonstrate operation of bilge alarm in Delta column LEGACY COMPONENT DESC: Bilge Alarm
Due 27 March 2003
Resolved 28 February 2003
Resolution: Bilge alarm was repaired and proven operational.
Electrical › Lighting (emergency)
Issued 19 February 2003
Resolved
Demonstrate operation of emergency lighting throughout vessel. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 27 February 2003
Resolved 27 February 2003
Resolution: Witnessed satisfactory operation of all emergency lighting throughout the vessel.
Electrical › Electric Generation Source (emergency)
Issued 19 February 2003
Resolved
Demonstrate operation of emergency generator.
Action required: 705 - Other - as specified
Due 27 February 2003
Resolved 27 February 2003
Resolution: Witnessed satisfactory operation of emergency generator afetr repairs to starting were conducted. The emergency generator assumed the load within 19 seconds
Communications › Alarms/Indicators
Issued 19 February 2003
Resolved
Demonstrate operation of emergency generator prime mover alarms & shutdowns. LEGACY COMPONENT DESC: Generator Prime Mover Alarms & Shutdowns
Action required: 705 - Other - as specified
Due 27 February 2003
Resolved 27 February 2003
Resolution: Witnessed satisfactory operation of overspeed trip, low lube oil pressure and high jacket water temperature alarms
Accommodation/Occupational Safety › Ventilation
Issued 19 February 2003
Resolved
Demonstrate operation of ventilation shutdowns LEGACY COMPONENT DESC: Shutdowns
Action required: 705 - Other - as specified
Due 27 February 2003
Resolved 27 February 2003
Resolution: Witnessed satisfactory operation of power ventilation shutdowns
Fire Fighting › Fire Main
Issued 19 February 2003
Resolved
Crop & renew fire main piping located in Delta column which has temporary doubler plates installed.
LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 28 February 2003
Resolution: Wasted fire main piping was renewed and proved tight.
Pollution Prevention/Response › Prevention Equipment
Issued 19 February 2003
Resolved
Demonstrate operation of oily water separator LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 27 February 2003
Resolved 27 February 2003
Resolution: Witnessed proper operation of oily water separator after repairs to the units oil content meter were made.
Electrical › Lighting (service)
Issued 19 February 2003
Resolved
Provide cover for fluorescent light fixture located in the storekeepers office LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 28 February 2003
Resolution: Cover was installed over light fixture and found satisfactory.
Communications › Alarms/Indicators
Issued 19 February 2003
Resolved
Prove proper operation of engine alarm light in all machinery spaces. LEGACY COMPONENT DESC: Engine Alarms
Action required: 705 - Other - as specified
Due 27 February 2003
Resolved 28 February 2003
Resolution: All engine alarm indicators were tested and found satisfactory after repairs were completed.
Lifesaving
Issued 14 March 2000
Resolved
CROP AND RENEW HANDRAILS AND DECK GRATING ON CATWALKS TO COLUMNS AS NECESSARY. GOUGE AND REWELD CRACK ON WALKWAY SUPPORTS OUTSIDE OF EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 14 April 2000
Resolved 29 March 2000
Lifesaving
Issued 22 March 1999
Resolved
RE-LOCATE LIFERAFT EMBARKATION LADDERS TO PROVIDE EASIER BOARDING ARRANGEMENTS; INSTALL (2) ADDITIONAL EMARKATION LADDERS FOR AFTER LIFERAFTS. INSTALLATION SHALL BE MADE TO THE SATISFACTION OF ATTENDING CLASS SURVEYOR OR [name withheld].
Condition: Unknown
Due 21 May 1999
Resolved 25 May 1999
Unknown
Issued 1 April 1998
Resolved
MAKE REPAIRS IN ACCORDANCE WITH ABS SURVEY REPORT, DATED 26MAR98. (a) REPAIR CRANES. (b) REPLACE AIR RECEIVER - PORT CRANE. (c) REPAIR LIFEBOAT HULL DAMAGE. (d) REPAIR FIRE DOORS IN ACCOMMODATION SPACES.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Lifesaving
Issued 1 April 1998
Resolved
INSTALL GENERAL ALARM BELLS IN SHAKER AREA, MARINE LOCKER AND MOON POOL.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Lifesaving
Issued 1 April 1998
Resolved
CONDUCT OPERATIONAL RELEASE GEAR TEST ON BOTH LIFEBOATS UNDER A LOAD OF 1.1TIMES THE TOTAL MASS OF THE LIFEBOAT WHEN LOADED WITH ITS FULL COMPLEMENT OF PERSONS AND EQUIPMENT.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Deck/Cargo
Issued 11 April 1997
Resolved
PROVE THAT THE AFT CRANES HAVE BEEN ANNUALLY INSPECTED.
Condition: Unknown
Due 12 May 1997
Resolved 11 June 1997
Lifesaving
Issued 11 April 1997
Resolved
FREE UP STIFF STEERING GEAR IN BOTH LIFEBOATS.
Condition: Unknown
Due 12 May 1997
Resolved 11 June 1997
Electrical
Issued 11 April 1997
Resolved
FUNCTION TEST TOTAL RIG SHUTDOWN AND PROVIDE MARINE SAFETY OFFICE PORT ARTHUR WITH A STATEMENT OF FACT FROM OFFSHORE INSTALLATION MANAGER REGARDING RESULTS OF TEST.
Condition: Unknown
Due 12 May 1997
Resolved 11 June 1997
Fire Fighting
Issued 11 April 1997
Resolved
MAKE PERMANENT REPAIRS TO SECTION OF FIREMAIN PIPING COMING OFF OF COLUMN DFIRE PUMP.
Condition: Unknown
Due 12 May 1997
Resolved 11 June 1997
Fire Fighting
Issued 24 April 1995
Resolved
CONDUCT HYDROSTATIC TEST ON ALL PORTABLE FIRE EXTINGUISHERS WITH STAMPED DATES OVER FIVE (5) YEARS OLD, AS NOTED ON FIRE EXTINGUISHER SERVICING REPORT.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Deck/Cargo
Issued 24 April 1995
Resolved
CONDUCT 5-YEAR LOAD TEST ON PORT AND STARBOARD AFT CRANES.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Lifesaving
Issued 24 April 1995
Resolved
REPLACE RATIONS IN LIFEBOATS AS FOLLOWS: L/B #1 - 13 AND L/B #2 - 30 (DUE TO LOSS OF VACUMM IN PACKAGES).
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Lifesaving
Issued 24 April 1995
Resolved
PROVIDE DOCUMENTATION ON FORKLIFT DESIGNATION FOR USE IN CLASS I, DIV.2 HAZARDOUS AREA (MUDPIT ROOM).
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Accommodation/Occupational Safety
Issued 24 April 1995
Resolved
PROVIDE ASME APPROVED OR FLAG STATE APPROVED RELIEF VALVES ON AIR RECEIVERSAND ENSURE THEY ARE EQUIPPED WITH A HAND RELIEVING DEVICE.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Engineering
Issued 25 April 1994
Resolved
PROVIDE PROCEDURE AND TEST OIL/WATER SEPARATOR.
Condition: Unknown
Due 25 April 1994
Resolved 25 April 1994
Electrical
Issued 25 April 1994
Resolved
PROVE PROPER OPERATION OF QUARTERS INTERMEDIATE (BATTERY) EMERGENCY LIGHTING.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Fire Fighting
Issued 25 April 1994
Resolved
PROVIDE TWO LIFELINES, FLASHLIGHTS, O2/COMB METER FOR FIREMANS OUTFITS.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Electrical
Issued 25 April 1994
Resolved
CHANGE LIFEBOAT EMBARKATION LIGHT OVER L/B NO. 1 TO EMERGENCY CIRCUIT.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Electrical
Issued 25 April 1994
Resolved
INSTALL TWO ADDITIONAL OBSTRUCTION LIGHTS APPROXIMATELY 90 DEGREES FROM TWOEXISTING LIGHTS.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Fire Fighting
Issued 25 April 1994
Resolved
PROVIDE BRACKETS FOR FIRE EXTINGUISHERS AS NECESSARY.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Documentation
Issued 25 April 1994
Resolved
SUBMIT IOPP CERTIFICATE REFLECTING OIL/WATER SEPARATOR INSTALLATION.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Documentation
Issued 25 April 1994
Resolved
SUBMIT OPERATIONS MANUAL AFTER OBTAINING FLAG STATE (LLOYDS) APPROVAL TO [name withheld].
Condition: Unknown
Due 25 April 1994
Resolved 25 April 1994