Inspection history · 32
4 June 2026
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8372364
7 April 2025
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8103961
30 April 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7890353
4 March 2022
Examination of Repairs · Internal Structural Exam · Damage Survey · Drydock Exam · DAPI Audit · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7406110
18 May 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7175695
18 October 2019
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7342205
1 August 2019
Initial Certification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6769802
3 April 2018
Administration · Spot Check (Safety)
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6384199
19 April 2017
Administration · Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6128466
10 March 2017
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6102620
29 November 2016
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6049265
28 November 2016
Administration
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6048805
3 August 2016
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5974608
1 April 2015
Administration
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5097644
18 March 2015
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5089538
17 March 2015
Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5086304
9 March 2015
Administration
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5081045
28 September 2014
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4997625
30 May 2014
Deficiency Check · Uninspected Other · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4878584
19 June 2013
DAPI Audit
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4625223
30 May 2013
Deficiency Check · Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4612024
30 May 2012
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4333845
12 July 2011
Deficiency Check · Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4079198
2 March 2010
Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3689940
10 October 2008
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3352252
25 September 2008
Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3333198
18 October 2007
Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3082578
7 September 2006
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2777524
18 July 2005
Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2432292
3 January 2005
Deficiency Check · Uninspected Other
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2267884
19 November 2004
Uninspected Other
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2255851
3 December 2001
Uninspected Towing Vessel
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1482618
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 April 2025
Resolved
The master of a towing vessel must ensure that each crewmember participates in fire-fighting drills and receives instruction at least once each month. Fire drill last conducted 2/4/2025. Drill conducted and recorded in TVR by the end of inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2025
Resolution: Witnessed master conduct a fire drill and examined TVR record.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 7 April 2025
Resolved
All lifesaving equipment must be tested and maintained in accordance with the minimum requirements of 46 CFR 199.190 of this chapter, which requires each battery clearly marked with an expiration date and used in an item of survival equipment must be replaced during the annual inspection if the expiration date has passed. The starboard water light's battery had expired by several years and had not been replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2025
Resolved 29 April 2025
Resolution: Vessel master provided report stating that the water light's battery had been replaced with a new battery.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 April 2025
Resolved
The operator of each self-propelled vessel 12 meters or more in length shall carry, on board and maintain for ready reference, a copy of these Rules. Neither a hard copy or electronic copy was available to the vessel master.
Action required: 10 - Deficiency Rectified
Resolved 8 April 2025
Resolution: Vessel master downloaded copy of publication to his phone.
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 18 May 2021
Resolved
Smoke detector located in crew working space; required to be in good condition. Detector fail to operated due to a missing battery. Prove proper operation of detector.
Action required: 10 - Deficiency Rectified
Due 18 May 2021
Resolved 18 May 2021
Resolution: New battery installed in detector and crew member proved proper operation by the end of the inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2021
Resolved
Portable fire pump and fire hose required to be on board vessel. Pump and hose failed to have a fitting to connect the two, prohibiting the delivery of water to any part of the vessel. Properly install appropriate fitting on pump.
Action required: 10 - Deficiency Rectified
Due 18 May 2021
Resolved 18 May 2021
Resolution: Fitting placed on board and crew demonstrated successful operation of pump and hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 May 2021
Resolved
Each exhaust pipe from an internal combustion engine in reach of personnel must be insulated or otherwise guarded. Insulation wrap on starboard main diesel engine frayed and induced protentional to exposed personnel to hot pipe. Properly guard hot piping from personnel access.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2021
Resolved 28 May 2021
Resolution: Exhaust pipe properly protected with insulation.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 May 2021
Resolved
Vessel required to have two life rings fitted with a floating electric waterlight. Vessel life rings fitted with only one waterlight. Properly outfit vessel with required number of approved waterlights prior to operating at night or during periods of low visibility.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2021
Resolved 28 May 2021
Resolution: Second waterlight placed on board in vicinity of ring buoy.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 August 2020
Resolved
Individual circuit breakers on switch boards and distribution panels are required to be labeled. The 12 volt distribution panel and the 110 volt switch board (box) were not labeled with the description of loads they service. Each panel and board to be properly labeled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2020
Resolved 31 August 2020
Resolution: Distribution panel and switch board properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 August 2020
Resolved
Visual distress signals on board were expired; not required while operating under current COI route restrictions.
Action required: 10 - Deficiency Rectified
Due 3 August 2020
Resolved 3 August 2020
Resolution: Expired signals removed from service.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 3 August 2020
Resolved
Stern void watertight hatch missing gasket. Gasket required to be reinstalled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 31 August 2020
Resolution: Gasket installed on stern hatch.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 August 2020
Resolved
Original Certificate of Documentation (COD) required to be on board vessel; current COD not on board vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 31 August 2020
Resolution: COD posted on board vessel.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 3 August 2020
Resolved
Vessel required to be outfitted with an illuminated magnetic compass (or swing-meter) at the operator's station. An illuminated magnetic compass (or swing-meter) was not installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 31 August 2020
Resolution: Operator's station outfitted with illuminated magnetic compass.
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 3 August 2020
Resolved
Safety orientation training records required to include name and signature of individual providing the training. Records did not include this information.
Action required: 10 - Deficiency Rectified
Due 3 August 2020
Resolved 3 August 2020
Resolution: Person providing training signed records.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 August 2020
Resolved
IAW with 46 CFR 143.245(b) periodic testing of alarm set points required to be recorded in Towing Vessel Record (as referenced by 46 CFR 140.615). Vessel did not have means to record information. Provide evidence of means to record information.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 31 August 2020
Resolution: Means to document required tests on board vessel.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 August 2020
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid. Starboard main diesel engine leaked motor oil through fill cap. Leak required to be secured.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 31 August 2020
Resolution: Leak secured; procedure in place to ensure proper maintenance eliminating reoccurance.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 August 2020
Resolved
Vessel required to be fitted with navigation lights & day shapes to display when aground and not under command. Vessel not fitted with lights or day shapes to display when aground (nor "not under command"(Rule 27) which are used to meet display requirements for meeting aground display requirements).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 29 September 2020
Resolution: Navigatin lights and means to display shapes installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 August 2020
Resolved
Hydraulic steering system required to be fitted with a pressure gauge. System pressure gauge was inoperable. System required to be fitted with an operable gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 31 August 2020
Resolution: Hydraulic system fitted with a new pressure gauge.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 August 2020
Resolved
Crew working space required to be fitted with emergency lighting meeting 46 CFR 143.410(b)"battery operated" or (c) "phosphorescent adhesive lighting". Vessel's crew space forward of engine room not fitted with emergency lighting. Emergency lighting required to be installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 31 August 2020
Resolution: Crew work area fitted with phosphorescent adhesive lighting at port and starboard exit doors.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 August 2020
Resolved
Handrails or equivalent protection must be installed near the periphery of all decks accessible to the crew. Bow of vessel not fitted with protective means. Bow of vessel required to be fitted with handrail or equivalent protection (i.e. wire rope, chain, lifeline).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 31 August 2020
Resolution: Bow fitted with protective means (chain attached between tow knees).
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 3 August 2020
Resolved
The owner or managing operator of an existing vessel not operating under a stability document must be able to show vessel's history of satisfactory service does not cause stability of the vessel to be in question. Required vessel managing operator to provide documentation showing satisfactory service.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 31 August 2020
Resolution: Documentation showing satisfactory service provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 August 2020
Resolved
Electrical outlet on exterior of vessel removed from service, however, 3/4 inch hole, to service cable run, located in forward bulkhead of superstructure not sealed; potentially exposing internal electrical components to moisture. Hole required to be made weather tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 31 August 2020
Resolution: Bulkhead made weather tight.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 3 August 2020
Resolved
Means must be provided to ensure that windows immediately forward of the operating station in the pilothouse allow for adequate visibility to ensure safe navigation regardless of weather conditions. Windshield wiper pivot found to be unable to keep blade properly against windshield. Prove proper operation of wiper.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 31 August 2020
Resolution: Vessel master proved proper operation of windshield wiper.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 3 August 2020
Resolved
Testing required by table in 46 CFR 143.245(b) of alarm set points required by 46 CFR 143.230 (high coolant temp, low oil pressure for mains and aux. gen) are required. Vessel did not have means to test high water temp for port and starboard main diesel engines. Provide means for testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 31 August 2020
Resolution: Means for testing demonstrated.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 August 2020
Resolved
Bow pivot assembly (unique to ferry design): Welds attaching the starboard arm chock (square steel block supporting starboard pivot assembly arm) to the bow deck were fractured. Properly repair fractured chock welds.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 31 August 2020
Resolution: Chock re-welded to vessel deck as designed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 August 2020
Resolved
Vessel required to have a documented fuel maintenance plan. Fuel maintenance plan not available for review. Make plan available for review.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 31 August 2020
Resolution: Fuel maintenance plan on board vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 August 2020
Resolved
Vessel required to be operated in a safe manner. Vessel did not have means to mount a required portable fire extinguisher. Portable fire extinguisher required to be mounted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2020
Resolved 31 August 2020
Resolution: Fire extinguisher mounted; starboard side of crew work area forward of engine room.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 23 July 2020
Resolved
General alarm required to have visual indicator in engine room. Visual indicator inoperable in engine room.
Action required: 10 - Deficiency Rectified
Due 6 August 2020
Resolved 3 August 2020
Resolution: Witnessed proper operation of general alarm visual indicator in engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 July 2020
Resolved
PFDs required to be outfitted with lights, whistles, and marked with vessel name. Four required PFDs not fitted with lights, whistles, or marked with vessel's name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2020
Resolved 3 August 2020
Resolution: Witnessed properly outfitted and marked PFDs.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 July 2020
Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. Semi-portable fire extinguisher was not properly secured to bulkhead.
Action required: 10 - Deficiency Rectified
Due 6 August 2020
Resolved 3 August 2020
Resolution: Semi-portable fire extinguisher secured to bulkhead with heavy duty chain.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 July 2020
Resolved
If vessel only carries two life buoys (life ring) one must not be fitted with a life line. Both life buoys were fitted with life lines. One life line required to be removed from a life buoy.
Action required: 10 - Deficiency Rectified
Due 6 August 2020
Resolved 3 August 2020
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 July 2020
Resolved
Vessel required to have means to remotely stop flow of fuel. Remote fuel shut off device was inoperable. Prove proper operation of device.
Action required: 10 - Deficiency Rectified
Due 23 July 2020
Resolved 23 July 2020
Resolution: Vessel master proved proper operation of fuel shut off device.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 July 2020
Resolved
Vessel required to have three 10-B:C and one 40-B portable fire extinguishers. Vessel lacked two 10-B:C portable fire extinguishers. Vessel required to place on board the required complement of portable fire extinguishers.
Action required: 10 - Deficiency Rectified
Due 23 July 2020
Resolved 23 July 2020
Resolution: One 40-B:C portable fire extinguisher placed on board vessel (authorized for two 10 B:C portable fire extinguishers IAW Table 46 CFR 142.230(a), note 1).
Communications › Alarms/Indicators › General Alarm
Issued 17 March 2015
Resolved
Installed general alarm did not function when energized from vessel operating station.
Action required: 705 - Other - as specified
Resolved 17 March 2015
Resolution: Disconnected wire reconnected and general alarm functioned properly.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 30 May 2014
Resolved
Fire detection system is indicating a system fault alarm. It is believed that the dead battery backup power supply is cause of this alarm. System was tested and functions properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 3 July 2014
Resolution: Received email notification that after installing generator and replacing back up battery power, fire detection system is operating as designed.
Navigation › Piloting/Steering › Magnetic Compass
Issued 30 May 2014
Resolved
Vessel is not equipped with a magnetic compass or swing meter. Vessel does operate within a limited geographic area at its ferry crossing and is exempted, however it is required within SUMR that an exemption letter be issued after written request.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 10 July 2014
Resolution: On 27 June SUMR received a request for a magnetic compass exemption. The exemption was granted by the COTP on 10 Jul 2014.
Navigation › Collision/Grounding Avoidance › Radar
Issued 30 May 2014
Resolved
Vessel is not equipped with a marine radar. Vessel does operate within a limited geographic area at its ferry crossing and is exempted, however it is required within SUMR that an exemption letter be issued after written request.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 10 July 2014
Resolution: On 27 June SUMR received a request for a marine radar exemption. The COTP granted the extension on 10 Jul.
Fire Fighting › Fire Hoses › Number
Issued 30 May 2014
Resolved
Vessel was missing fire hose and nozzle for portable fire pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 2 July 2014
Resolution: CIV F. Karnuth vistited vessel and verified hose and nozzle installed on poratble fire pump.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 30 May 2013
Resolved
Dry exhaust not insulated on port engine.
Due 7 June 2013
Resolved 27 June 2013
Resolution: Exhaust re-insulated.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 30 May 2013
Resolved
Starboard propulsion shaft packing gland leaks excessively when in reverse.
Action required: 705 - Other - as specified
Due 30 June 2013
Resolved 27 June 2013
Resolution: Examined packing glands during vessel operation, all sat.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 30 May 2013
Resolved
Port engine coolent hose at aft end of engine not double clamped.
Due 30 June 2013
Resolved 27 June 2013
Resolution: Coolent hoses properly clamped.
Engineering › Generator (propulsion/auxiliary-electric) › Coil
Issued 30 May 2013
Resolved
Cooling coils heavily oiled.
Due 7 June 2013
Resolved 27 June 2013
Resolution: Genorator removed from the vessel. Crew members stated genorator was unnecessary and will not be re-installed.
Engineering › Lubricating Oil Service System › Gauge
Issued 12 July 2011
Resolved
Oil pressure guage on starboard MDE did not operate.
Due 19 July 2011
Resolved 21 July 2011
Resolution: Witnessed proper operation of gauge.
Engineering › Fuel Oil Service System › Hose
Issued 12 July 2011
Resolved
Ensure all fuel hoses are properly clamped.
Due 19 July 2011
Resolved 21 July 2011
Resolution: Operator purchased new hose (SAE 1527) and double clamped where possible. New hose purchase was at operator''s discression.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 25 September 2008
Resolved
Name of vessel not on lifebuoy.
Action required: 705 - Other - as specified
Resolved 10 October 2008
Resolution: Ring buoy properly marked.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 25 September 2008
Resolved
Approximately 1 four foot section of exhaust had no insulation on starboard engine.
Action required: 705 - Other - as specified
Resolved 10 October 2008
Resolution: Exhaust insulated.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 25 September 2008
Resolved
No rules of the road on board vessel.
Action required: 705 - Other - as specified
Resolved 10 October 2008
Resolution: Determined that due to size of tow vessel, inland rules not required. Vessel operator did place a copy of the rules on board the vessel.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 18 October 2007
Resolved
Vessel required to have an additional B-II or equivilant fire extinguisher to be compliant with subchapter C requirements.
Action required: 705 - Other - as specified
Resolved 25 September 2008
Fire Fighting › Remote Fuel Shutoff › General
Issued 3 January 2002
Resolved
Remote fuel shutoffs were located inside the engine room and not located in a safe space outside of the engineroom. LEGACY COMPONENT DESC: Location
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 February 2002
Resolved 19 November 2004