MAURY USCG vessel records Sign in
← All vessels

TAHOE GAL

TAHOE GAL is a 1994 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 1994, most recently in May 2025, along with 54 deficiencies and 1 casualty investigation in 2010.

Records from 1994 to 2025. Most recent: inspection, 15 May 2025.

Built
1994
Last inspected
15 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCL9997
402253
Flag
UNITED STATES
—
Maury page id
psix-402253

Inspections, by type

…with no type recorded9
Years with a record 29 calendar years (1994–2025)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)63.2 ft × 20.0 ft × 4.3 ft
Registered tonnagegross 38 / net 24
ITC dimensions (L × B × D)63.2 ft × 20.0 ft × 4.3 ft
ITC tonnageNot recorded
BuilderSKIPPERLINER INDUSTRIES · LA CROSSE, WI, UNITED STATES · built 1994
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Regulatory (Subpart C or D), Gross Ton
24 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCL9997MMSI not assigned · expired · voluntarily equipped · granted 23 August 1994, cancelled 30 October 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 60

15 May 2025 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8130624
16 May 2024 COI Inspection · Underwater Inspection in lieu of Drydock · DAPI Audit · Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7907734
15 June 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7715861
19 May 2023 Annual Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7694263
20 June 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7472337
15 June 2020 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6974290
10 May 2019 Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6681462
11 June 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6441560
11 May 2017 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6131896
2 June 2016 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5895016
28 July 2015 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5199038
11 June 2012 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4335207
15 August 2011 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4116442
16 December 2010 Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3920531
27 January 2010 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3926804
6 May 2009 Hull Examination · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3463975
11 June 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3228029
29 May 2007 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2953293
9 May 2006 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2639850
30 March 2006 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2612715
2 May 2005 Annual Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2353096
11 May 2004 Hull Examination · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2064843
23 March 2004 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2029584
22 May 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1779772
3 June 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1620160
17 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1073801
14 May 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1382247
3 May 2000 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1386814
14 September 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1420196
11 August 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 775031
1 July 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1084360
3 May 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1381561
25 June 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1127644
5 June 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 123844
21 May 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1126675
14 August 1997 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1119110
15 July 1997 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 780509
12 June 1997 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 773784
7 May 1997 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1108029
7 November 1996 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1171559
3 September 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 941307
17 July 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1414667
14 July 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 44601
7 May 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1082271
4 April 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1081671
15 March 1996 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 885068
13 March 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 80262
25 July 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1182802
22 June 1995 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 880818
10 June 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 107709
24 March 1995 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 842343
24 March 1995 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 871324
29 November 1994 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 871603
9 November 1994 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 870592
9 November 1994 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 874475
14 October 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 870316
2 October 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 29270
30 June 1994 Deficiency Check · Initial Certification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1176658
26 June 1994 Inclining Experiment
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 867749
21 June 1994 Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1332756

Deficiency record · 54

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2025 Resolved
... Waste receptacles must be constructed of non combustible materials with no openings in the sides or bottom. Replace plastic trash cans in galley and bar space. 46 CFR 177.406 (f)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 29 May 2025
Resolution: Accepted photos to rectify deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 May 2024 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. No marking of max passengers on vessel. 46 CFR 185.602(g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 12 June 2024
Resolution: Received photo from operator with markings for upper deck capacity.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 June 2020 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). The vessel’s ring life buoy had unserviceable retroreflective material installed in the incorrect orientation. Renew the ring life buoy retroreflective material IAW IMO Resolution A.658(16). 46 CFR 185.604 (i)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 29 June 2020
Resolution: Recieved pictures of retroflective tape on vessel's ring life buoys.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 June 2020 Resolved
Fire hose may be a garden hose of not less than 5/8 inch nominal inside diameter. The hose shall be in one piece not less than 25 feet and not more than 50 feet in length. The fire hose was discovered to have a pinhole leak. Replace the fire hose IAW 46 CFR 181.15-10. 46 CFR 181.15-10 “Old T”
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 30 June 2020
Resolution: Vessel replaced the fire hose to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 June 2020 Resolved
Connections must be made to battery terminals with permanent type connectors. The port battery terminal connection was made with a wing nut. Replace the wing nut with a permanent type connector IAW 46 CFR 183.350. 46 CFR 183.350 (d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 30 June 2020
Resolution: Owner replaced wing nut with proper fastener to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 15 June 2020 Resolved
The inspection and maintenance of the vessel’s survival craft shall be logged or otherwise documented for review by the Coast Guard upon request. The vessel did not have a lifesaving maintenance log available for review. The log was created and the inspection was conducted during the annual examination. 46 CFR 185.702 (d)
Action required: 10 - Deficiency Rectified
Due 15 June 2020
Resolved 15 June 2020
Resolution: The log was created and the inspection was conducted during the annual examination.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 June 2020 Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The crew training log was not available for review. The log was created and the training was conducted during the annual examination. 46 CFR 185.420 (c)
Action required: 10 - Deficiency Rectified
Due 15 June 2020
Resolved 15 June 2020
Resolution: The log was created and the training was conducted during the annual examination.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 May 2019 Resolved
Each buoyant apparatus shall be fitted with a life line. Vessel buoyant apparatus life lines deteriorated and pull apart.180.175(d). Replacement lifelines must meet 160.010.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2019
Resolved 26 July 2019
Resolution: Phone reminder mid-June, but due to postponed AHE correction verbally reported but not witnessed until this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2019 Resolved
All cable and wire must be installed in a manner to avoid chafing and other damage. Control wires over port main diesel melted or smashed together.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2019
Resolved 26 July 2019
Resolution: Phone reminder mid-June, but due to postponed AHE correction verbally reported but not witnessed until this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 May 2019 Resolved
Electical eqiupment on a vessel must be installed to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire. Wire penetration between engine space and main deck not filled.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2019
Resolved 26 July 2019
Resolution: Phone reminder mid-June, but due to postponed AHE correction verbally reported but not witnessed until this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2019 Resolved
All cable and wire must be installed with metal supports spaces not more than 24" apart. Wire through run in fuel tank room not secured in kind with existing wiring.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2019
Resolved 26 July 2019
Resolution: Phone reminder mid-June, but due to postponed AHE correction verbally reported but not witnessed until this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 May 2019 Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except where it is not subject to damage. Lazarette light in way of access missing cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2019
Resolved 26 July 2019
Resolution: Phone reminder mid-June, but due to postponed AHE correction verbally reported but not witnessed until this date.
Electrical › Electrical Distribution System (service) › Conductor
Issued 12 June 2018 Resolved
Wiring on a vessel needs to be in accordance with marine standard. Vessel contains single strand non marine grade cable in Void 6 bilge high water alarm wiring. 46 CFR 183.01-15
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2018
Resolved 15 September 2018
Resolution: Verified proper installation.
Construction/Loadline › Structures › Door
Issued 11 June 2018 Resolved
A watertight door must be provided for each opening in a deckhouse. Gaskets are worn on all 3 main deck doors. 46 CFR 171.24 (a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2018
Resolved 12 June 2018
Resolution: Gaskets were replaced on all three doors.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 11 May 2017 Resolved
Vessel's fuel shutoff valves failed to close completely. Vessel must ensure valves close all the way. - 46 CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 June 2017
Resolved 11 May 2017
Resolution: Shutoff valves fixed on the spot.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 28 July 2015 Resolved
Renew worn flex hoses on the port and starboard raw water cooling intake lines (located aft of the strainers)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2015
Resolved 28 August 2015
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 28 July 2015 Resolved
Rapair falling lagging throughout the engineroom overhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2015
Resolved 28 August 2015
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 14 January 2010 Resolved
Submit all plans for re-power project. Complete re-power worklist issued by USCG.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2011
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 14 January 2010 Resolved
Complete underway inspection of re-power, operationally testing all propulsion machinery.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2011
Lifesaving › Buoyant Apparatus › Marking
Issued 6 May 2009 Resolved
Mark vessel name and number of persons on both sides of all 4 buoyant apparatus.
Condition: Improper/Lack of Maintenance
Due 6 June 2009
Resolved 28 May 2009
Resolution: Repairs completed satisfactorily
Lifesaving › Buoyant Apparatus › Marking
Issued 6 May 2009 Resolved
Paint forward stbd bouyant apparatus correct international orange color.
Condition: Improper/Lack of Maintenance
Due 6 June 2009
Resolved 28 May 2009
Resolution: Inspected satisfactorliy.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 6 May 2009 Resolved
Perform underway man overboard drill, fire drill and propulsion/steering tests.
Due 6 June 2009
Resolved 28 May 2009
Resolution: Observed all required drills & tests.
Lifesaving › Buoyant Apparatus › Marking
Issued 6 May 2009 Resolved
Affix retro-reflective SOLAS tape (renew) on both sides of all 4 buoyant apparatus.
Condition: Improper/Lack of Maintenance
Due 6 June 2009
Resolved 1 September 2016
Resolution: Administratively closed
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 11 June 2008 Resolved
Install fuse protection on all current carrying conductors (positive) wires at the battery. With exception of the Engine starting circuit, In accodance with 46 CFR 183.380.
Due 11 June 2008
Resolved 11 June 2008
Engineering › Compressed Air System (control) › Valve
Issued 11 June 2008 Resolved
Prove proper operatrion of air compressor relief valve IAW 46 CFR 176.812 (a)(b).
Due 11 July 2008
Resolved 19 June 2008
Electrical › Electrical Distribution System (service) › Cable
Issued 9 May 2006 Resolved
Submit plans for approval to the local OCMI for the replacement of MDE and generator starting cable with approved UL Marine grade cable in accordance with 46 CFR 183.340 (d) (2).
Due 9 June 2006
Resolved 29 May 2007
Lifesaving › Visual Distress Signals (General) › Condition
Issued 9 May 2006 Resolved
Renew 3 cracked waterlights for the lifefloats. COS 5/9/06.
Due 9 June 2006
Resolved 9 May 2006
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 2 May 2005 Resolved
Label "crew only" for the crew PFDs.
Due 2 July 2005
Resolved 6 May 2005
Lifesaving › Lifebuoys › Serviceable
Issued 2 May 2005 Resolved
Renew the reflective tape on forward life ring.
Due 4 July 2005
Resolved 6 May 2005
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 2 May 2005 Resolved
Renew the reflective tape on 2 children PFDs.
Due 2 July 2005
Resolved 6 May 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 2 May 2005 Resolved
Properly secured the life jacket container on the second deck.
Due 2 July 2005
Resolved 2 May 2005
Lifesaving › Buoyant Apparatus › Marking
Issued 2 May 2005 Resolved
Label the buoyant apparatus with the vessel's name and max passenger count.
Due 2 July 2005
Resolved 6 May 2005
Stability › Unintentional Flooding › General
Issued 2 May 2005 Resolved
Cap off the starboard and port tank in void #3.
Due 2 July 2005
Resolved 6 May 2005
Engineering › Bilge Water Management System › Interface Detector
Issued 2 May 2005 Resolved
Secure all float switches.
Due 2 July 2005
Resolved 6 May 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 June 2002 Resolved
Provide proof of valid Certificate of Documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2002
Resolved 3 June 2002
Engineering
Issued 11 August 1999 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, REPAIRS TO PORT ENGINE MUST BE APPROVED AND TESTED BY AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 12 August 1999
Resolved 12 August 1999
Lifesaving
Issued 21 May 1998 Resolved
CLEARLY SEPARATE AND LABEL CHILD PFD'S FROM ADULT PFD'S ON UPPER DECK.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Navigation
Issued 21 May 1998 Resolved
TIGHTEN/REPAIR PACKING GLAND ON PORT RUDDER POST TO STOP LEAKING.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Documentation
Issued 7 May 1997 Resolved
PROVIDE WRITTEN DESCRIPTION OF DRUG TESTING PROGRAM. PROGRAM SHOULD CONTAIN ITEMS OUTLINED IN "DRUG TESTING PROGRAM CHECKOFF SHEET".
Condition: Unknown
Due 7 May 1997
Resolved 7 May 1997
Unknown
Issued 17 July 1996 Resolved
RESUBMIT PLANS RETURNED FOR REVISION ON 14NOV95. SEE LETTER 16711/TAHOE GAL 14NOV94.
Condition: Unknown
Due 17 July 1996
Resolved 17 July 1996
Electrical
Issued 4 April 1996 Resolved
LINE EXISTING OR PROVIDE APPROPRIATE BATTERY BOX ON BRIDGE
Condition: Unknown
Due 13 May 1996
Resolved 13 May 1996
Lifesaving
Issued 4 April 1996 Resolved
APPLY REFLECTIVE TAPE ON RING BUOY
Condition: Unknown
Due 13 May 1996
Resolved 13 May 1996
Lifesaving
Issued 4 April 1996 Resolved
INSTALL LIFEJACKET DONNING PLACARDS.
Condition: Unknown
Due 13 May 1996
Resolved 13 May 1996
Documentation
Issued 4 April 1996 Resolved
UPDATE EMERGENCY INSTRUCTIONS
Condition: Unknown
Due 13 May 1996
Resolved 13 May 1996
Electrical
Issued 22 June 1995 Resolved
MARK ALL EMERGENCY LIGHTS WITH "E".
Condition: Unknown
Due 22 July 1995
Resolved 28 July 1995
Accommodation/Occupational Safety
Issued 22 June 1995 Resolved
REPLACE CRACKED WINDOW ON UPPER DECK PORT SIDE.
Condition: Unknown
Due 22 July 1995
Resolved 28 July 1995
Documentation
Issued 30 June 1994 Resolved
PROVIDE DOCUMENT WITH CORRECT OWNER/OPERATOR ADDRESS.
Condition: Unknown
Due 31 July 1994
Resolved 26 August 1994
Navigation
Issued 30 June 1994 Resolved
PROVIDE DEVIATION CARD FOR COMPASS.
Condition: Unknown
Due 31 July 1994
Resolved 26 August 1994
Navigation
Issued 30 June 1994 Resolved
PROVIDE REINFORCEMENT FOR MASTHEAD LIGHT.
Condition: Unknown
Due 31 July 1994
Resolved 26 August 1994
Lifesaving
Issued 30 June 1994 Resolved
INSTALL PREVENTER HINGE ON 3RD COMPARTMENT DECK HATCH.
Condition: Unknown
Due 31 July 1994
Resolved 26 August 1994
Lifesaving
Issued 30 June 1994 Resolved
INSTALL SAFETY CHAINS ON WOMEN'S HEAD AND GALLEY FLOOR HATCHES.
Condition: Unknown
Due 31 July 1994
Resolved 26 August 1994
Engineering
Issued 30 June 1994 Resolved
INSTALL DUCT TO BILGE ON ENGINE ROOM NATURAL VENTILATION SYSTEM.
Condition: Unknown
Due 31 July 1994
Resolved 26 August 1994
Lifesaving
Issued 30 June 1994 Resolved
SECURE LIFE PRESERVER BOXES TO UPPER DECK.
Condition: Unknown
Due 31 July 1994
Resolved 26 August 1994
Documentation
Issued 30 June 1994 Resolved
DRAFT DRUG TESTING PROGRAM FOR VESSEL.
Condition: Unknown
Due 31 July 1994
Resolved 26 August 1994

Casualty record · 1

27 January 2010Routine · role: Involved in a Marine Casualty · activity 3926804
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record