Records from 1994 to 2025. Most recent: inspection, 20 October 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 55
20 October 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8256915
24 June 2025
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8165923
7 October 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8009280
3 October 2023
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7796504
4 May 2023
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7680511
3 May 2023
Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7680133
30 September 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7566481
26 April 2022
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7443965
24 June 2021
COI Inspection · Deficiency Check · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7231490
16 June 2021
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7227247
16 July 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6993387
31 May 2019
Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6699246
8 April 2019
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6654186
17 August 2018
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6495625
12 July 2017
DAPI Audit · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6230045
5 July 2016
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 5926033
16 July 2012
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4369765
20 January 2012
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4228389
25 January 2010
Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3669711
8 September 2008
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3320539
16 May 2008
Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3208151
10 December 2007
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3112522
31 October 2007
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3105230
17 July 2007
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3019710
18 May 2006
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2653961
2 May 2006
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2637641
12 July 2005
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2423131
11 February 2005
Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2290622
13 April 2004
Deficiency Check · Hull Examination · Periodic Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2053667
1 May 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1780575
9 May 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1616020
26 April 2002
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1609840
25 February 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1488927
1 February 2002
Damage Survey
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1483283
11 June 2001
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1065156
2 May 2001
Hull Examination · COI Inspection · Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1373459
30 April 2001
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1063945
10 October 2000
Damage Survey
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1467259
7 October 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 104550
7 October 2000
Type not recorded
No type recorded · Station Manasquan Inlet · USCG East District (CGD-E) · Activity 1514441
4 May 2000
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1049578
14 April 1999
Deficiency Check · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1126736
21 January 1999
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1452453
23 June 1998
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1128975
22 April 1998
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1123990
10 April 1997
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1102862
19 March 1997
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1091418
22 August 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1258540
14 May 1996
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1083205
30 April 1996
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1082429
9 May 1995
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1234718
24 May 1994
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1088567
24 May 1994
Initial Certification · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1171620
6 May 1994
Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 861592
6 April 1994
Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 858147
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 June 2025
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination
must undergo a drydock examination and an internal structural at least once every two years. Vessel is overdue for it's drydock inspection. Drydock inspection was due no later than 31May2025. Conduct drydock inspection prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 June 2025
Resolved 3 July 2025
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 7 October 2024
Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. Compass light was out, prove proper operation of compass light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2024
Resolved 15 October 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 May 2023
Resolved
SHAFT STRUT AFT PORT LOOSE FASTENDERS, TIGHTEN. PRIOR TO CREDIT DRYDOCK.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2023
Resolved 5 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2022
Resolved
Exhaust piping shall be gas-tight through its length. STBD fiberglass exhaust pipe found delaminated and leaking water and exhaust gas. PORT stainless exhaust pipe found cracked at the “Y” weld and leaking water and exhaust gas. Repair/Replace to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2022
Resolved 5 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2022
Resolved
Flexible nonmetallic hose must be complete with factory-assembled end fitting requiring no further adjustment of the fittings on the hose or field attachable type fittings may be used. Flexible hose installed in lengths not to exceed 30 inches may meet the following requirements: hose clamps may be installed with two clamps, at both ends of the hose, which do not rely on spring tension and are installed beyond the bead or flare or serrations of the spud, pipe or hose fitting. Noted fuel hoses in excess of 30 inches without fixed approved fittings, and fuel hoses less than 30 inches installed without double hose clamps. Repair/replace to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2022
Resolved 5 October 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 September 2022
Resolved
All equipment including switches, fuses, lampholders, etc, must be suitable for the voltage and current utilized. Electrical outlet on the STBD Bridge Bulkhead found with lower outlet burnt. Remove outlet, inspect box and connecting wiring for damage and evidence of burning or overcurrent. Report any damage found to our office. Replace outlet to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2022
Resolved 5 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 September 2022
Resolved
A submersible electric bilge pump may be used provided that: the pump is permanently mounted and the pump discharge line is suitably supported. Forward electric bilge pump in forward berthing found unsecured from vessel, and discharge pipe disconnected and without hose clamp. Lazarette electric bilge pump also found unsecured. Secure pumps to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2022
Resolved 28 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 September 2022
Resolved
Each life jacket must be marked with Type I retro reflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. Replace retro reflective material on 10 identified life jackets with approved material to the satisfaction of the reviewing Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2022
Resolved 5 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 September 2022
Resolved
Each ring life buoy must be marked with Type II retro reflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Found vessel’s life ring without retroactive material. Repair to the satisfaction of the reviewing Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2022
Resolved 5 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 September 2022
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Found vessel’s port generator electrical housing without required bolts securing it to the generator. Housing rattles around while generator is in operation. Repair to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2022
Resolved 5 October 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 September 2022
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Found numerous holes through Engine Room / Lazarette bulkhead and a PVC pipe between the Engine Room and forward Bunkroom Bulkhead. Plug holes to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2022
Resolved 28 November 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 September 2022
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Bilge alarm for forward bunk room found with short circuit / electrical failure in indicating device on bridge causing intermittent operation. Replace / Repair to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2022
Resolved 5 October 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 September 2022
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. Found Coffee Maker connected to outlet with residential extension cord. Remove extension cord to the satisfaction of the reviewing Marine Inspector.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2022
Resolved 5 October 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 September 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Outlets and switches on bridge found without covers. Replace to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2022
Resolved 5 October 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 September 2022
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Found wiring termination exposed with electrical tape in overhead of lazarette. Repair to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2022
Resolved 5 October 2022
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 30 September 2022
Resolved
A vessel must comply with the applicable requirements for a station license and installation certificates to be issued by the Federal Communications Commission as set forth in 47 CFR Part 80. Found vessel’s MMSI number incorrectly input into vessel’s radio. Rectify to the satisfaction of the reviewing Marine Inspector.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2022
Resolved 5 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2021
Resolved
BATTERY CONNECTIONS MUST BE MADE WITH PERMANENT TYPE CONNECTORS. CHARGER CONNECTION FOUND DISCONNECTED NOT SAFE ENDED, REPLACE OR REMOVE.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2021
Resolved 7 July 2021
Resolution: Charger properly tied into battery terminals.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2021
Resolved
ELECTRICAL EQUIPMENT ONBOARD MUST BE MAINTAINED TO PROTECT PASSENGERS AND CREW FROM ELECTRICAL HAZARDS. TWO EXTERIOR LIGHTS ON BRIDGE DECK FOUND BROKEN FROM THIER HOUSING AND HANGING BY THE CONDUCTORS. FIXTURE NOT INSTALLED IN HEAD, WIRES EXPOSED NOT SAFE ENDED. BREAKER NOT TAGGED OUT. 46 CFR 183.200
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2021
Resolved 7 July 2021
Resolution: Properly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2021
Resolved
Fuel lines shall be accessible and protected from mechanical injury. Fuel line on the port MDE is chaffing. Reroute or install chaffe gear.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2021
Resolved 13 August 2021
Resolution: Chaffing gear was installed on fuel lines on PMDE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2021
Resolved
ALL MACHINERY EQUIPMENT MUST BE MAINTAINED TO AFFORD ADEQUATE PROTECTION FROM CAUSING FIRE, FAILURE OR PERSONNEL INJURY. PORT MDE EXHAUST HANGER/SUPPORT CORRODED, REPLACE. 46 CFR 182.100
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2021
Resolved 7 July 2021
Resolution: Hanger replaced.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 6 July 2021
Resolved
SEWAGE SYSTEMS SHALL MEET 33 CFR 159.57. HOLDING TANK VENTS ARE CRACKED PVC PIPE, MAY ALLOW VAPOR TO ENTER ENGINE ROOM, REPAIR/REPLACE. 33 CFR 159.7
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2021
Resolved 7 July 2021
Resolution: PVC replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 6 July 2021
Resolved
THE CONSTRUCTION AND ARRANGEMENT OF THE VESSEL MUST ALLOW FOR ITS SAFE OPERATION. THE PILOT HOUSE TOP OVERHANG IS DRY-ROTTED. THE LADDER PROVIDING ACCESS TO LIFEFLOATS MOUNTS TO THIS STRUCTURE AND IS LOOSE. REPAIR IN KIND OR PROPOSE TEMP REPAIR. BY 7/13/21. (Temp approved 7/7/21, permanent required 1/1/2022. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2022
Resolved 26 April 2022
Resolution: Overhang and ladder replaced; found structurally sound.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 July 2021
Resolved
EACH RING BUOY MUST BE CLEARLY AND LEGIBLY MARKED WITH THE VESSELS NAME. NAME FADED ON RING BUOY REMARK. 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2021
Resolved 23 July 2021
Resolution: Vessel re-stenciled ring buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2021
Resolved
STEERING SYSTEMS SHALL BE MAINTAINED SUITABLE FOR SERVICE INTENDED. PORT RUDDER POST PACKING IS LEAKING MORE THAN NORMAL. RE-PACK/REPAIR. BY 7/13/21 46 CFR 176.814
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 July 2021
Resolved 23 July 2021
Resolution: Port rudder post packing tightened, witnessed operation no leak.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 6 July 2021
Resolved
ELECTRICAL EQUIPMENT ONBOARD MUST BE MAINTAINED TO PROTECT PASSENGERS AND CREW FROM ELECTRICAL HAZARDS. RE-MOUNT/REPAIR MOUNT FOR AFT PA SPEAKER, MISSING SCREW & STRUCTURE CRACKED. 46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2021
Resolved 13 August 2021
Resolution: Aft PA speaker properly mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2021
Resolved
ALL UNFIRED PRESSURE VESSELS ORIGINAL TESTING AND DESIGN MUST MEET SUBCHAPTER F. VESSEL AIRHORN AIR RECIEVER RECENTLY INSTALLED, DOES NOT HAVE ASME MARKINGS PROVIDE MANUFACTURER SPECIFICATION SHEET FOR STANDARD OF MANUFACTURE E.G. ASME, SAE ETC...ENSURE PRV IS AT OR BELOW MAWP. TEMP RES PRESSURE VESSEL TAGGED OUT OF SERVICE. 46 CFR 182.330
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 January 2022
Resolved 26 April 2022
Resolution: Air reciever removed from vsl.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 6 July 2021
Resolved
AN EXPOSED HAZARD SUCH AS ROTATING MACHINERY MUST BE PROPERLY PROTECTED. DRIVE BELTS ON FORWARD END OF THE PORT MDE ARE EXPOSED, INSTALL GUARD.(SEE STBD MDE). 46 CFR 177.960
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2021
Resolved 30 August 2021
Resolution: Sufficient guard installed over rotating machinery.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 6 July 2021
Resolved
ELECTRICAL EQUIPMENT ONBOARD MUST BE MAINTAINED TO PROTECT PASSENGERS AND CREW FROM ELECTRICAL HAZARDS. NEW INSTALLATION OF LED FLOOD LIGHTS AND CABLING, INCOMPLETE IN PROGRESS NOT YET CONNECTED TO POWER. INSTALL TO BE INSPECTED BY A MARINE INSPECTOR PRIOR TO USE WITH PASSENGERS ONBOARD, THE BREAKER SHALL REMAIN SECURED, THE CIRCUIT SHALL NOT BE TIED IN. 46 CFR 183.200
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 January 2022
Resolved 26 April 2022
Resolution: LED Lighting/cable found sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 24 June 2021
Resolved
ALL MACHINERY EQUIPMENT MUST BE MAINTAINED TO AFFORD ADEQUATE PROTECTION FROM CAUSING FIRE, FAILURE OR PERSONNEL INJURY. THE PROTECTIVE BENCH/PASSENGER SEATING ABOVE THE FUEL TANK LINE WAS REMOVED, THE VENT PIPE IS EXPOSED AND COULD BE DAMAGED BY OR SAT ON BY A PASSENGER. REPLACE THE BENCH COVER. 46 CFR 182.100. Temp Repair accepted 7/7/21, permanent by 1/1/2022.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 January 2022
Resolved 26 April 2022
Resolution: Bench replaced in way of the vent.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 June 2021
Resolved
A vessel that is exposed to saltwater more than 3 months in any 12 month period must undergo a dry-dock and internal structural exam at least once every 2 years. Vessels last drydock was 12APR2019, overdue as of 30APR2021.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2021
Resolved 24 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 17 August 2018
Resolved
Vessel can only use a single weak link for a maximum of three life rafts in tandem. Vessel has four life rafts attached to a single weak link.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 August 2018
Resolved 27 August 2018
Resolution: Vessel added an additional weak link to the life float system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 August 2018
Resolved
A vessel required to carry a single ring buoy must have a float light attached to it via line fastened by a clip around the body of the ring buoy. Vessel's ring buoy was found to not have a detachable float light affixed to it.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 August 2018
Resolved 25 August 2018
Resolution: Added a detachable float light to the ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 17 August 2018
Resolved
Vessels must use a line that is dark in color or certified to be resistant to damage from ultraviolet light to attach the life floats to the weak link and each other. Vessel's lines that attached the life float to the weak link and to each other was found severely sun damaged and wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2018
Resolved 27 August 2018
Resolution: Replaced line linking the life floats to each other and to the weak link.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 17 August 2018
Resolved
Vessel's life floats must have a functioning float light attach by way of a lanyard. The float light attach to the top life float on the starboard side was found to be inoperative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2018
Resolved 27 August 2018
Resolution: Replaced battery to the starboard side life float light.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 17 August 2018
Resolved
Vessel must keep onboard corrected and up to date Charts and Navigational publications to include charts, tide and current table, and light list. Vessel's Charts and Publications were found to not be corrected or up todate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2018
Resolved 27 August 2018
Resolution: Vessel proved required publications, light list and tides and currents, were on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 August 2018
Resolved
Vessel must have onboard enough PFD's in servable condition to satisfy the number of passengers on listed their COI. A total of four of the necessary PFD's were found in disrepair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2018
Resolved 27 August 2018
Resolution: Replaced 4 life jackets with new.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 5 July 2016
Resolved
Missing 04 adult life jackets. Provide 04 life jackets. Passenger count reduced by 04 adult.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 5 July 2016
Resolution: Corrected on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 5 July 2016
Resolved
The marking of the location of the life jackets is not visible. Relabel in a visible location.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 5 July 2016
Resolution: Corrected on the spot.
Communications › Radio Communications › EPIRB
Issued 5 July 2016
Resolved
The hydrostatic release for the EPIRB is expired. Replace hydrostatic release.Vessel restricted to operations with in 3 miles of shore.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 8 July 2016
Resolution: Vessel replaced hydrostatic release.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 5 July 2016
Resolved
The valve for the type III MSD was not secured. Either remove handle, padlock valve or wire tire the valve shut.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 8 July 2016
Resolution: Corrected on the spot.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 8 September 2008
Resolved
Missing CG Light List
Condition: Unknown
Due 18 September 2008
Resolved 18 September 2008
Resolution: Replaced with new CG Light List
Navigation › Piloting/Steering › US Coast Pilot
Issued 8 September 2008
Resolved
Missing US Coast Pilot
Condition: Unknown
Due 18 September 2008
Resolved 18 September 2008
Resolution: Replaced with New US Coast Pilot
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 8 September 2008
Resolved
Missing Tide & Tidal Current Tables
Condition: Unknown
Due 18 September 2008
Resolved 18 September 2008
Resolution: Replace with new tables
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 2 May 2006
Resolved
Replace corroded fuel piping in lazarette and engine room with approved fuel piping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2006
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 2 May 2006
Resolved
Port and stbd fuel tanks leak. Make proper repairs and pressure test to the satisfaction of the attending CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2006
Construction/Loadline › Penetrations › Gasket
Issued 12 July 2005
Resolved
Gasket on deck hatch for lazarette worn.
Due 12 August 2005
Resolved 13 July 2005
Resolution: new gasket installed.
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 12 July 2005
Resolved
Stbd MDE r/w intake hose dry-rotted.
Due 12 August 2005
Resolved 13 July 2005
Resolution: installed new hose.
Documentation › Markings/Placards › Lifejacket Placard
Issued 12 July 2005
Resolved
Post secondary Type I PFD doning placard.
Due 12 August 2005
Resolved 13 July 2005
Resolution: corrected
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 April 2004
Resolved
Vessel missing enrollment letter- had application and receipt.
Due 25 June 2004
Resolved 22 June 2004
Resolution: Proper drug paperwork provided for proof of proper program.
Operations/Management › Passenger Operations › Safety Orientation
Issued 13 April 2004
Resolved
Mark upper deck with "Crew Only"
Due 25 June 2004
Resolved 22 June 2004
Resolution: Upper deck marked with crew only.
Communications › Radio Communications › EPIRB
Issued 13 April 2004
Resolved
Provide current battery, hydrostatic release mechanism and antenna for EPIRB. Restricted to 3 nm from shore.
Due 25 June 2004
Resolved 22 June 2004
Resolution: Epirb items renewed as necessary.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 25 April 2003
Resolved
Provide proof of drug testing participation for 2003.
Condition: Improper/Lack of Maintenance
Due 1 June 2003
Resolved 28 May 2003
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 25 April 2003
Resolved
Provide 01 additional childs life jacket.
Condition: Improper/Lack of Maintenance
Due 1 June 2003
Resolved 28 May 2003
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 25 April 2003
Resolved
Renew retro-reflective tape on 06 adult life jackets.
Condition: Improper/Lack of Maintenance
Due 1 June 2003
Resolved 28 May 2003
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 April 2003
Resolved
Repair engine room and lazzarette bilge alarms.
Due 1 June 2003
Resolved 1 May 2003
Resolution: Vessel owner had de-energized they bilge alarm system accidentally during exam. All alarms operational.
Communications › Alarms/Indicators
Issued 9 May 2002
Resolved
LOWER HIGH WATER FLOAT SWITCH IN #1 COMPARTMENT. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper Installation
Due 16 May 2002
Resolved 16 May 2002
Lifesaving › Buoyant Apparatus
Issued 9 May 2002
Resolved
RENEW 100FT SEA PAINTER FOR LIFE FLOAT WEAK LINK.
Condition: Improper/Lack of Maintenance
Due 16 May 2002
Resolved 16 May 2002
Lifesaving › Lifejacket/PFD (General)
Issued 9 May 2002
Resolved
RENEW RETRO TAPE ON 14 LIFE JACKETS. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 16 May 2002
Resolved 16 May 2002
Lifesaving › Lifebuoys
Issued 9 May 2002
Resolved
INSTALL NEW RETRO TAPE ON LIFE RING, RENEW CLIP.
Condition: Improper/Lack of Maintenance
Due 16 May 2002
Resolved 16 May 2002
Lifesaving › Lifejacket/PFD (General)
Issued 9 May 2002
Resolved
PROVIDE 01 CHILD LIFE JACKET. LEGACY COMPONENT DESC: Quantity
Condition: Improper/Lack of Maintenance
Due 16 May 2002
Resolved 16 May 2002
Navigation › Piloting/Steering
Issued 9 May 2002
Resolved
PROVIDE #3 US COAST PILOT. LEGACY COMPONENT DESC: US Coast Pilot
Condition: Unknown
Due 16 May 2002
Resolved 16 May 2002
Communications › Radio Communications
Issued 9 May 2002
Resolved
PROVIDE AND POST EMERGENCY BROADCAST PLACARD. LEGACY COMPONENT DESC: VFH Radiotelephone
Due 16 May 2002
Resolved 16 May 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 9 May 2002
Resolved
PROVIDE CURRENT PAIN RELIEVER FOR FIRST AID KIT. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 16 May 2002
Resolved 16 May 2002
Lifesaving › Hand Flares
Issued 9 May 2002
Resolved
PROVIDE 6 ORANGE SMOKE FLARES. LEGACY COMPONENT DESC: Quantity
Condition: Improper/Lack of Maintenance
Due 16 May 2002
Resolved 16 May 2002
Engineering › Bilge Water Management System
Issued 9 May 2002
Resolved
STENCIL BILGE MAINFOLD VALVES WITH COMPARTMENT NUMBERS. LEGACY COMPONENT DESC: Manifold
Due 16 May 2002
Resolved 16 May 2002
Construction/Loadline
Issued 4 May 2000
Resolved
FREE UP AND PROVE PROPER OPERATION OF WATERTIGHT DECK HATCH DOGS._x001C_
Condition: Unknown
Due 1 June 2000
Resolved 13 July 2000
Engineering
Issued 4 May 2000
Resolved
REPAIR LEAKING ELBOW/FLEX HOSE CONNECTION IN ENGINE ROOM.
Condition: Unknown
Due 1 June 2000
Resolved 13 July 2000
Documentation
Issued 4 May 2000
Resolved
RENEW RADIO SAFETY FCC LICENSE.
Condition: Unknown
Due 1 June 2000
Resolved 13 July 2000
Lifesaving
Issued 14 April 1999
Resolved
PROPERLLY STOW LIFE FLOATS
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Engineering
Issued 14 April 1999
Resolved
REPAIR FUEL LEAK AT ELBOW UNDER PORT FUEL FILTER
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Construction/Loadline
Issued 14 April 1999
Resolved
REMOVE OIL FROM BILGE IN ENGIN COMPARTMENT
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Engineering
Issued 14 April 1999
Resolved
CORRECT EXCESSIVE LEAKAGE AT PORT AND STB SHAFT PACKING
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Fire Fighting
Issued 14 April 1999
Resolved
PROVIDE A NOZZLE FOR FIRE HOSE
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Fire Fighting
Issued 14 April 1999
Resolved
DEMONSTRATE THE OPERATION OF EMERGENCY SHUT OFF OF GENERATOR DUIRING FIXED FIREFIGHTING SYSTEM ACTUATION
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Lifesaving
Issued 14 April 1999
Resolved
PROVIDE EPIRB AND MOUNT
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Navigation
Issued 14 April 1999
Resolved
PROVIDE CURRENT CHARTS FOR ROUTE
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Construction/Loadline
Issued 14 April 1999
Resolved
PROVIDE COMPARTMENT LABLES FOR HIGH WATER ALARMS
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Lifesaving
Issued 14 April 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Engineering
Issued 21 January 1999
Resolved
PROVIDE EMERENCY FUEL OIL SHUTDOWNS FOR BOTH MAIN ENGINES AND AUX_x001C_ GENERATOR. FUEL OIL SHUTDOWNS ARE TO OPERATE FROM OUTSIDE THE ENGINE ROOM.
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Electrical
Issued 30 April 1996
Resolved
PROPERLY HARD WIRE COFFEE POT OUTLET.
Condition: Unknown
Due 30 May 1996
Resolved 16 May 1996
Unknown
Issued 30 April 1996
Resolved
INSTALL BELT GUARD ON SERVICE GENERATOR
Condition: Unknown
Due 30 May 1996
Resolved 16 May 1996
Unknown
Issued 30 April 1996
Resolved
INSTALL BELT GUARDS ON STBD MDE FOR JABSCO AND GEN BELTS.
Condition: Unknown
Due 30 May 1996
Resolved 16 May 1996