MAURY USCG vessel records Sign in
← All vessels

KRATEROS

KRATEROS is a 1992 freight ship. The Coast Guard has recorded 9 inspections since 1998, most recently in May 2008, along with 4 deficiencies and 2 operational controls.

Records from 1998 to 2008. Most recent: inspection, 10 May 2008.

Built
1992
Last inspected
10 May 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9038787 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
402481
Flag
MALTA
—
Maury page id
psix-402481

Inspections, by type

…with no type recorded4
Years with a record 3 calendar years (1998–2008)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it25905 - Convention (Subpart B), Gross Ton
25905 - Regulatory (Subpart C or D), Gross Ton
13656 - Regulatory (Subpart C or D), Net Ton
43595 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 9

10 May 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3203248
9 May 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3202886
8 May 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3202298
8 May 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3202612
28 April 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3194152
21 April 2008 PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3188689
20 June 2005 ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2396469
22 January 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 188622
11 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 411730

Deficiency record · 4

Construction/Loadline › Hull › Bottom Plating
Issued 10 May 2008 Resolved
Vessel experienced grounding at MM 03 Lower Mississippi River, Above Head of passes.
Action required: 705 - Other - as specified
Due 10 May 2008
Resolved 10 May 2008
Resolution: Received class report satisfying requirements.
Construction/Loadline › Hull › Bottom Plating
Issued 9 May 2008 Resolved
Vessel experienced a grounding at MM 3, Lower Mississippi River.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 May 2008
Resolved 9 May 2008
Resolution: Received a class report rectifying the deficiency.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 21 April 2008 Resolved
1430 - Aux Machinery - The vessel was unable to demonstrate the satisfactory operation of the emergency generator's secondary start. Prior to departing the port. The vessel is required to repair the secondary start and submit a report from the certificate issuing authority attesting to the satisfactory operation of the secondary start. - SOLAS 74 (81 Amend.) Ch. II-1 Reg. 44.2
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2008
Resolved 21 April 2008
Resolution: Crew found battery cables partly loose. Received class report attesting to the removal, cleaning, and reconnection of battery cables. Emergency generator test started in the presence of attending GL surveyor and satisfactory.
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 11 January 1998 Resolved
RENEW INTERNATIONAL SEWAGE PREVENTION CERTIFICATE. MARPOL 73/78 ANNEX IV
Condition: Unknown
Due 11 February 1998
Resolved 20 June 2005

Ownership record