MAURY USCG vessel records Sign in
← All vessels

DOWN UNDER

DOWN UNDER is a 1994 passenger vessel (inspected). The Coast Guard has recorded 41 inspections since 1994, most recently in March 2026, along with 62 deficiencies.

Records from 1994 to 2026. Most recent: inspection, 23 March 2026.

Built
1994
Last inspected
23 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB5039
402486
Flag
UNITED STATES
366905220 (licence lapsed)
Maury page id
psix-402486

Inspections, by type

…with no type recorded2
Years with a record 27 calendar years (1994–2026)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)31.0 ft × 11.7 ft × 3.5 ft
Registered tonnagegross 10 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBONNER YACHTS · ELMORE, AL, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeBox
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB5039MMSI 366905220 · expired · compulsorily equipped · granted 20 August 2003, cancelled 9 November 2013
WCJ6207MMSI not assigned · expired · compulsorily equipped · granted 13 July 1994, cancelled 26 September 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 41

23 March 2026 DAPI Audit · Administrative Inspection · COI Inspection · Vessel Attendance
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8317668
21 April 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8116545
3 February 2025 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8072778
6 May 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7907870
3 May 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7680529
14 February 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7636785
21 April 2022 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7435356
6 April 2022 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7426319
1 April 2021 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7162333
11 March 2021 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7152945
16 April 2020 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6943416
26 March 2019 Hull Examination · DAPI Audit · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6658424
29 May 2018 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6422257
10 August 2017 DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6229428
2 August 2017 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6228660
23 March 2017 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6105254
7 April 2016 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5847224
27 July 2015 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5197988
8 August 2014 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4947940
22 April 2008 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3186210
6 March 2008 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3155562
8 May 2006 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2643561
11 August 2005 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2458498
9 August 2004 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2157953
8 May 2004 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2138085
21 April 2004 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2048676
22 September 2003 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1913786
15 August 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1875865
2 May 2002 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1611779
12 June 2001 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1072748
9 May 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1423609
15 May 2000 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1393496
24 June 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 795332
17 March 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1461963
13 May 1998 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1421507
14 May 1997 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1428767
8 May 1996 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1388024
11 May 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1360200
26 May 1994 Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1173260
17 May 1994 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 866479
17 May 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1170779

Deficiency record · 62

02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 3 May 2023 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessel has conducted an alteration that is not approved by it's Stability Letter. Remove the installed shelves or conduct a new Simplified Stability Test to rectify this deficiency.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2023
Resolved 16 May 2023
Resolution: Received photograph of the overhead bins/shelves removed. The vessel has returned to its original condition; satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 May 2023 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rule. Inspectors were unable to see the Navigation Lights energized. Provide evidence that all of the vessel's Navigation Lights can be energized and are in working condition.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2023
Resolved 16 May 2023
Resolution: Received photographs of the vessel's Navigation Lights returned to satisfactory condition.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2023 Resolved
Every breaker at each distribution panel must be clearly identifiable and labeled. Provide evidence that each breaker is labeled to define intended purpose. Any breakers with no assigned function must be labeled as "Spare".
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2023
Resolved 16 May 2023
Resolution: Received photographs of the vessel's distribution panel having each breaker properly labeled; satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 April 2022 Resolved
Inspect steering systems in accordance with 46 CFR 176.814. Steering ram was leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2022
Resolution: Ram repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 April 2022 Resolved
Inspect lifesaving equipment in accordance with 46 CFR 176.808. All childrens PFDs failed inspection. Adult passengers only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 April 2022
Resolution: PFDs provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 April 2022 Resolved
Inspect machinery in accordance with 46 CFR 176.804. Fuel lines were not double hose clamped.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 21 April 2022
Resolution: Double hose clamps provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 April 2022 Resolved
Comply with 46 CFR part 16. Proof of enrollment in Drug Testing program was no provided for crew.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2022
Resolved 21 April 2022
Resolution: Proof of consortium enrollment provided.
Fire Fighting › Fire Bucket › Lanyard
Issued 10 August 2017 Resolved
Replace fire bucket lanyard
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 16 August 2017
Resolution: Vessel replaced lanyard
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 August 2017 Resolved
Replace righ buoy lanyard
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 16 August 2017
Resolution: Vessel replaced lanyard
Construction/Loadline › Penetrations › Valve Flange
Issued 10 August 2017 Resolved
Install hull skin valve in head salt water system
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 16 August 2017
Resolution: Vessel installed valve
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 August 2017 Resolved
Complete a credit annual exam. Vessel annual exam is overdue as of 07Jul17
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2017
Resolved 10 August 2017
Resolution: Vessel completed a credit annual exam
Documentation › Logs/Records › Drug Test Records
Issued 8 August 2014 Resolved
Conduct a satisfactory DAPI audit
Action required: 705 - Other - as specified
Due 7 September 2014
Resolved 30 September 2014
Resolution: Completed satisfactory DAPI audit
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 8 August 2014 Resolved
Replace retroreflective tape on identified lifejackets. Total persons allowed is reduced to 34.
Action required: 705 - Other - as specified
Due 21 August 2014
Resolved 30 September 2014
Resolution: Vessel replaced retro tape on lifejackets.
Documentation › Certificates/Documents › FCC SSL
Issued 22 April 2008 Resolved
Provide FCC safety certificate and FCC marine radio operator's permit.
Action required: 705 - Other - as specified
Due 22 April 2008
Resolved 10 June 2008
Documentation › Logs/Records › Drug Test Records
Issued 22 April 2008 Resolved
Provide documentation for drug and alcohol program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2008
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 22 April 2008 Resolved
Provide person with operators license on board vessel for inspection.
Action required: 705 - Other - as specified
Due 22 April 2008
Resolved 22 June 2008
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 22 April 2008 Resolved
Provide current training log book for abandon ship, man overboard, and fire drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2008
Resolved 29 May 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 22 April 2008 Resolved
Provide current light list, chart, and tide tables for local area.
Action required: 705 - Other - as specified
Due 22 April 2008
Resolved 29 May 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 April 2008 Resolved
Replace forward running light and stern light.
Action required: 705 - Other - as specified
Due 22 April 2008
Resolved 10 June 2008
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 22 April 2008 Resolved
Provide two night flares for a full compliment of 6.
Action required: 705 - Other - as specified
Due 22 April 2008
Resolved 29 May 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 22 April 2008 Resolved
Provide one B-I fire extinguisher and mount.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 22 April 2008 Resolved
Replace safety seal for B-II fire extinguisher.
Action required: 705 - Other - as specified
Due 22 April 2008
Resolved 29 May 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 April 2008 Resolved
Provide visual signal for high level bilge alarms.
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 29 June 2008
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 22 April 2008 Resolved
Provide two portable lights for emergency lighting.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2008
Engineering › Fuel Oil Service System › Tank
Issued 22 April 2008 Resolved
Reconfigure fuel area away from passenger seating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2008
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 6 March 2008 Resolved
Secure fuel tank to deck.
Action required: 705 - Other - as specified
Due 6 April 2008
Resolved 6 April 2008
Construction/Loadline › Hull › Hull Plating
Issued 6 March 2008 Resolved
Repair fiberglass spots on hull.
Due 6 April 2008
Resolved 20 March 2008
Construction/Loadline › Penetrations › Valve Flange
Issued 6 March 2008 Resolved
Place cut off valves on thru hull fittings for bilge pump.
Action required: 705 - Other - as specified
Due 6 April 2008
Resolved 6 April 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 March 2008 Resolved
Replace stern and anchor lights.
Action required: 705 - Other - as specified
Due 6 April 2008
Resolved 6 April 2008
Electrical › Electric Generation Source (service) › Conductor
Issued 6 March 2008 Resolved
Seal wiring for both outboard engines.
Action required: 705 - Other - as specified
Due 6 April 2008
Resolved 6 April 2008
Engineering › Gasoline Engine (propulsion) › Spark Plug (4 cycle)
Issued 11 August 2005 Resolved
Demonstrate operation of starboard outboard engine. 46 CFR 176.804(a)
Action required: 705 - Other - as specified
Due 11 September 2005
Resolved 12 August 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 11 August 2005 Resolved
Replace A-II portable fire appliance w/ a B-II as per COI. 46 CFR 181.500
Action required: 705 - Other - as specified
Due 11 September 2005
Resolved 12 August 2005
Engineering › Gasoline Engine (propulsion) › Fuel Intake (2 stroke)
Issued 9 August 2004 Resolved
Replace B-II flexible fuel hose w/ suitable A-I or B-I IAW 46 CFR 182.458
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 11 August 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 August 2004 Resolved
Replace non-dated battery for Electric Floating Light IAW 46 CFR 181.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 11 August 2004
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 August 2004 Resolved
Replace grab lines on Life Ring Buoy IAW 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 11 August 2004
Engineering › Bilge Water Management System › Pump
Issued 9 August 2004 Resolved
Prove proper operation of Bilge Alarm. Noted no audible on fwd alarm. Also visual indicated fwd and mid-body, it was connected in series IAW 46 CFR 182.520.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 11 August 2004
Construction/Loadline › Hull › Bracket
Issued 21 April 2004 Resolved
Recaulk around engine mounts both port and starboard engine. LEGACY COMPONENT DESC: Side Shell
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2004
Resolved 8 May 2004
Resolution: Engine Brackets recaulked.
Construction/Loadline › Hull › Bracket
Issued 21 April 2004 Resolved
Recaulk eye bolt at the bow of the vessel. LEGACY COMPONENT DESC: Side Shell
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2004
Resolved 8 May 2004
Resolution: Bow Eye caulked.
Construction/Loadline › Penetrations › Gasket
Issued 21 April 2004 Resolved
Replace forepeak hatch gasket. LEGACY COMPONENT DESC: Gasket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2004
Resolved 8 May 2004
Resolution: Gasket renewed.
Documentation › Certificates/Documents
Issued 15 August 2003 Resolved
Provide proper FCC Documentation, I.E., Station License, Safety Certificate, vessel limited to 1000' from land until corrected.. LEGACY COMPONENT DESC: Passenger Ship Safety Certificate
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 22 September 2003
Resolution: Owner provided proper FCC documentation.
Documentation › Manifests/Lists
Issued 15 August 2003 Resolved
Provide emergency instruction list as required. LEGACY COMPONENT DESC: Muster List/Emergency Instructions
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 22 September 2003
Resolution: Owner provided emergency instruction list.
Accommodation/Occupational Safety › Occupational Safety
Issued 15 August 2003 Resolved
Provide rails or mesh as required by 46 CFR 177.900 across stern bench. LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 22 September 2003
Resolution: Owner provided rails or mesh as required across stern bench.
Engineering › Fuel Oil Service System
Issued 15 August 2003 Resolved
Replace existing portable fuel tank and provide proper stowage on deck. LEGACY COMPONENT DESC: Tank
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 22 September 2003
Resolution: Owner replaced portable fuel tank and proper stowage.
Accommodation/Occupational Safety › Occupational Safety
Issued 15 August 2003 Resolved
Provide "No Smoking" placard posting in vicinity of portable fuel tank. LEGACY COMPONENT DESC: Smoking
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 22 September 2003
Resolution: Owner provided "No Smoking" placard and posted in vicinity of fuel tank.
Electrical › Electrical Distribution System (service)
Issued 15 August 2003 Resolved
Provide proper cable and wiring under console as required. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 22 September 2003
Resolution: Owner provided proper cable and wiring under console.
Communications › Alarms/Indicators
Issued 15 August 2003 Resolved
Provide 3/4 full level indicator on sewage tank. LEGACY COMPONENT DESC: Sewage Level Indicator
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 22 September 2003
Resolution: Owner provided 3/4 full level indicator on sewage tank.
Lifesaving
Issued 9 May 2001 Resolved
PRIOVIDE REQUIRED FIRST AID KIT ITEMS AS REQUIRED BY 46CFR184.710.
Condition: Unknown
Due 9 May 2001
Resolved 9 May 2001
Fire Fighting
Issued 9 May 2001 Resolved
PROVIDE ON BOARD THREE 2.5 GALLON FIRE BUCKETS WITH LANYARDS AND MARKED WITH VESSEL'S NAME, IN ACCORDANCE WITH 46CFR181.
Condition: Unknown
Due 9 May 2001
Resolved 9 May 2001
Accommodation/Occupational Safety
Issued 9 May 2001 Resolved
PROVIDE MESH OR EQUIVALENT ON DECK RAILS IN ACCORDANCE WITH 46CFR177.900.
Condition: Unknown
Due 9 May 2001
Resolved 9 May 2001
Navigation
Issued 9 May 2001 Resolved
PROVIDE NAUTICAL PUBLICATIONS OR APPLICABLE EXCERPTS THEREFROM IN ACCORDANCE WITH 46CFR184.420.
Condition: Unknown
Due 9 May 2001
Resolved 9 May 2001
Lifesaving
Issued 9 May 2001 Resolved
PROVIDE CORROSION RESISTANT CLIP ON RING LIFE BUOY IN ACCORDANCE WITH 46CFR180.70.
Condition: Unknown
Due 9 May 2001
Resolved 9 May 2001
Documentation
Issued 11 May 1995 Resolved
PROVIDE PROOF OF FCC SAFETY CERTIFICATE AND FCC MARINE OPERATORS PERMIT.
Condition: Unknown
Due 31 July 1995
Resolved 9 August 1995
Lifesaving
Issued 11 May 1995 Resolved
REPLACE LINE ATTACHING WATER LIGHT TO RING BOUY WITH A LINE NOT LESS THEN SIX (6) FEET IN LENGTH.
Condition: Unknown
Due 31 July 1995
Resolved 9 August 1995
Accommodation/Occupational Safety
Issued 11 May 1995 Resolved
VENTILATION DUCTING FOR ENGINE ROOM SHALL BE RIGID AND MADE OF METALLIC OR OTHER FIRE RESISTANT MATERIAL.
Condition: Unknown
Due 31 July 1995
Resolved 9 August 1995
Construction/Loadline
Issued 11 May 1995 Resolved
RENEW/INSTALL RETAINING CHAIN OR LINE TO FWD HATCH.
Condition: Unknown
Due 31 July 1995
Resolved 9 August 1995
Lifesaving
Issued 26 May 1994 Resolved
CHILD PFD'S TO BE STOWED SEPARATELY IAW 46 CFR 180.25-5
Condition: Unknown
Due 26 May 1994
Resolved 17 April 1995
Fire Fighting
Issued 26 May 1994 Resolved
PORTABLE FIRE EXTINGUISHER TO BE PROVIDED AS PER 46 CFR 181.30
Condition: Unknown
Due 26 May 1994
Resolved 17 April 1995
Electrical
Issued 26 May 1994 Resolved
PROVIDE PROTECTIVE COVER OVER ELECTRICAL INSTALLATION IN THE HEAD.
Condition: Unknown
Due 26 May 1994
Resolved 17 April 1995
Unknown
Issued 26 May 1994 Resolved
STENCIL EMERGENCY FUEL SHUTOFF IAW 46 CFR 185.30-20
Condition: Unknown
Due 26 May 1994
Resolved 17 April 1995
Unknown
Issued 26 May 1994 Resolved
POST EMERGENCY CHECK OFF LIST IAW 46 CFR 185.25-5
Condition: Unknown
Due 26 May 1995
Resolved 17 April 1995
Unknown
Issued 26 May 1994 Resolved
PROVIDE EVIDENCE OF ENROLLMENT IN APPROVED RANDOM CHEMICAL TESTING PROGRAM.
Condition: Unknown
Due 26 May 1994
Resolved 17 April 1995
Lifesaving
Issued 26 May 1994 Resolved
PROVIDE PYROTECHNICS STOWAGE IAW 46 CFR 180.35-10
Condition: Unknown
Due 26 May 1994
Resolved 17 April 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.