Records in 1995. Most recent: inspection, 10 March 1995.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Fire Fighting
Issued 7 March 1995
Resolved
RENEW HOLDED AND DETERIORATED FIRE HOSES ON MAIN DECK FIRE STATIONS.
Condition: Unknown
Due 7 March 1995
Resolved 9 March 1995
Deck/Cargo
Issued 7 March 1995
Resolved
WATERTIGHT HATCH ON MAIN DECK LEADING TO ROPE LOCKER IS MISSING CLOSURE DEVICES.
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Unknown
Issued 7 March 1995
Resolved
PROVIDE 6 BOLTS TO EACH STANDARD DISCHARGE CONNECTION.
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
RENEW DETERIORATED DISCHARGE HOSES TO CO2 FIRE SUPPRESSION SYSTEM IN ENGINEROOM (2 EACH)
Condition: Unknown
Due 7 March 1995
Resolved 9 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
RENEW/REPAIR THE FOLLOWING FIRE HYDRANTS AND DISTRIBUTION/ISOLATION VALVES:(A)FIRE HYDRANT ON MAIN DECK STARBOARD. (B)FIRE MAIN DRAIN VALVE LOCATED NEXT TO VENT T7 ON MAIN DECK STARBOARD SIDE. (C)2 ISOLATION VALVES LOCATED NEXT TO EMERGENCY FIRE PUMP IN SHAFT ALLEY WAY.
Condition: Unknown
Due 7 March 1995
Resolved 9 March 1995
Documentation
Issued 7 March 1995
Resolved
PROVIDE UPDATED U.S. COAST COAST PILOT, LIGHT LIST, TIDE TABLES, TIDAL CURRENT TABLES AND INLAND NAVIGATIONAL RULES.
Condition: Unknown
Due 7 March 1995
Resolved 9 March 1995
Construction/Loadline
Issued 7 March 1995
Resolved
RENEW/REPAIR WATERTIGHT HATCH COVER THATS DETERIORATED LOCATED ON MAIN DECKAFT OF VENT #T6
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Construction/Loadline
Issued 7 March 1995
Resolved
RENEW CLOSURE DEVICES ON WATERTIGHT HATCH COVERS ON FORECASTLE DECK PORTSIDE.
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Lifesaving
Issued 7 March 1995
Resolved
PROVIDE TWO LIFERING BOUYS WITH 27.5 METERS OF LINE TO BE LOCATED ON PORT &STARBOARD SIDE OF VESSEL.
Condition: Unknown
Due 7 March 1995
Resolved 9 March 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
THE FOLLOWING VENT CLOSURES WERE MISSING HANDLE WHEEL OR OPERATING MECHANISM FOR CLOSURE DEVICE: T50, T2, T6, T8.
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Lifesaving
Issued 7 March 1995
Resolved
RENEW DETERIORATED LIFELINES TO PORT AND STARBOARD LIFEBOAT.
Condition: Unknown
Due 7 March 1995
Resolved 9 March 1995
Construction/Loadline
Issued 7 March 1995
Resolved
RENEW DETERIOATED WATERTIGHT DOOR LOCATED ON STARBOARD SIDE MEXT TO VENT T6.
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Lifesaving
Issued 7 March 1995
Resolved
RENEW DAMAGED RING LIFEBUOY LOCATED ON FOCSLE STARBOARD SIDE
Condition: Unknown
Due 7 March 1995
Resolved 9 March 1995
Lifesaving
Issued 7 March 1995
Resolved
RENEW HYDROSTATIC RELEASES TO PORTSIDE INFLATABLE LIFERAFTS.
Condition: Unknown
Due 7 March 1995
Resolved 9 March 1995
Lifesaving
Issued 7 March 1995
Resolved
RENEW RETRO-REFLECTIVE MATERIAL ON ALL LIFE RINGS.
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Lifesaving
Issued 7 March 1995
Resolved
MEANS SHALL BE PROVIDED FOR BRINGING THE LIFEBOAT AGAINST THE SHIPS SIDE AND THERE HOLDING THEM SO THAT PERSONS MAY SAFELY EMBARK.
Condition: Unknown
Due 7 March 1995
Resolved 9 March 1995
Lifesaving
Issued 7 March 1995
Resolved
INSTALL LIFEBOAT EQUIPMENT IN ACCORDANCE WITH SOLAS 60 CHAPTER III REGULATION 11 TO EACH LIFEBOAT.
Condition: Unknown
Due 7 March 1995
Resolved 9 March 1995
Lifesaving
Issued 7 March 1995
Resolved
PROVIDE ONE APPROVED COVER OF A HIGHLY VISIBLE COLOR FOR PROTECTING THE OCCUPANTS AGAINST INJURY BY EXPOSURE, FOR EACH LIFEBOAT.
Condition: Unknown
Due 7 March 1995
Resolved 9 March 1995
Lifesaving
Issued 7 March 1995
Resolved
PROVIDE A MANUAL BILGE PUMP FOR EACH LIFEBOAT.
Condition: Unknown
Due 7 March 1995
Resolved 9 March 1995
Lifesaving
Issued 7 March 1995
Resolved
INSTALL GASKETS ON WATERTIGHT COMPARTMENT OPENINGS FOR EQUIPMENT/PROVISIONSON PORT/STBD LIFEBOATS.
Condition: Unknown
Due 7 March 1995
Resolved 9 March 1995
Lifesaving
Issued 7 March 1995
Resolved
REPAIR/RENEW ENGINE COVERS FOR EACH MOTOR LIFEBOAT.
Condition: Unknown
Due 7 March 1995
Resolved 9 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
PROVIDE FIRE HOSE TO FIRE STATION NUMBER 10 LOCATED ON MAIN DECK FANTAIL.
Condition: Unknown
Due 7 March 1995
Resolved 9 March 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
THE FOLLOWING VENT CLOSURES BY NUMBER WERE INOPERABLE DUE TO LACK OF MAINTENANCE, MISSING CLOSURE DEVICE, OR WING NUT CLOSING DEVICE MISSING: T47, T48, T38, T37, T49, T41, T35, T35, T27, T28, T30, T51, T4, T3, T7, T9,T10, T11, T27, T13 AND T14
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
PROVIDE FIRE NOZZLE AND SPANNER WRENCH AT EACH FIRE STATION THROUGHOUT VESSEL. NOTED IMPROPER TYPE NOZZLES IN MACHINERY SPACES AND INOPERATIVE NOZZLES ON MAIN DECK FIRE STATIONS.
Condition: Unknown
Due 7 March 1995
Resolved 9 March 1995