Records in 1994. Most recent: inspection, 28 March 1994.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Navigation
Issued 19 March 1994
Resolved
This vessel over 1600 GT operated in the Brownsville Ship Channel, a navigable water of the U.S., without a currently corrected copy of the U.S.Coast Guard Lightlist. Lightlist onboard no corrections had been made nor were there any Notice to Mariners onboard.
Condition: Unknown
Due 22 March 1994
Resolved 25 March 1994
Navigation
Issued 19 March 1994
Resolved
33CFR164.33(a)(1)(ii) This vessel of over 1600 GT operated in the Brownsville Ship Channel, a navigable water of the U.S. without chart 11302or any Notice to Mariners._x001C_ _x001C_
Condition: Unknown
Due 22 March 1994
Resolved 25 March 1994
Navigation
Issued 19 March 1994
Resolved
This vessel of 1600 GT operated in the Brownsville Ship Channel, a navigable water of the U.S., without a currently corrected copy of the U.S.Coast Pilot volume V. 1993. Volume of U.S. Coast Pilot V, No Notice of Mariners corrections made nor available._x001C_
Condition: Unknown
Due 22 March 1994
Resolved 25 March 1994
Engineering
Issued 19 March 1994
Resolved
Prove Proper certification and operation of the Oily Water Seperator.
Condition: Unknown
Due 28 March 1994
Resolved 28 March 1994
Navigation
Issued 19 March 1994
Resolved
Provide on board Brn Inner Harbor Chart Number 11302 prior to getting underway.
Condition: Unknown
Due 21 March 1994
Resolved 24 March 1994
Deck/Cargo
Issued 19 March 1994
Resolved
Prior to next cargo onload, disassemble and prove proper operation of pressure/vacuum valves located at each cargo tank ullage in the presence ofthe Marine Inspector.
Condition: Unknown
Due 19 March 1994
Resolved 19 March 1994
Deck/Cargo
Issued 19 March 1994
Resolved
Prior to next cargo onload, install and prove proper operation of remote manual fire damper closure capability for pumproom ventilation duct fire dampers.
Condition: Unknown
Due 19 March 1994
Resolved 19 March 1994
Construction/Loadline
Issued 19 March 1994
Resolved
Research means of testing and prove proper operation of Oily Water Seperator.
Condition: Unknown
Due 19 March 1994
Resolved 19 March 1994
Engineering
Issued 19 March 1994
Resolved
Conduct hydrostatic testing of bunker piping prior to transfer of bunkers.
Condition: Unknown
Due 21 March 1994
Resolved 24 March 1994
Navigation
Issued 19 March 1994
Resolved
Provide current/updated Coast Pilot and Light List prior to getting underway.
Condition: Unknown
Due 21 March 1994
Resolved 24 March 1994
Fire Fighting
Issued 19 March 1994
Resolved
Effect permanent repairs to main deck fire main system prior to trasfer of cargo, transfer of bunker and prior to getting underway.
Condition: Unknown
Due 21 March 1994
Resolved 24 March 1994
Fire Fighting
Issued 19 March 1994
Resolved
Renew all failed and improperly fire fighting hoses prior to transfer of cargo, prior to transfer of bunkers and prior to getting underway.
Condition: Unknown
Due 21 March 1994
Resolved 24 March 1994
Deck/Cargo
Issued 19 March 1994
Resolved
Renew all cargo tank vent flame screens prior to transer of cargo.
Condition: Unknown
Due 21 March 1994
Resolved 24 March 1994
Deck/Cargo
Issued 19 March 1994
Resolved
Conduct hydrostatic testing of cargo transfer piping prior to transfer of cargo.
Condition: Unknown
Due 21 March 1994
Resolved 24 March 1994
Deck/Cargo
Issued 19 March 1994
Resolved
Prior to next cargo onload, install and prove proper operation of pressure/vacuum valve located at cargo tank #1-S ullage in the presence of the Marine Inspector.
Condition: Unknown
Due 19 March 1994
Resolved 19 March 1994