← All vessels
NORDSTRAND
Freight Ship · General Dry Cargo Ship class · Built 1990s · USCG Heartland District (CGD-H) · Other hulls named NORDSTRAND
NORDSTRAND is a 1993 freight ship. The Coast Guard has recorded 21 inspections since 1998, most recently in February 2012, along with 19 deficiencies and 4 operational controls.
Records from 1998 to 2012. Most recent: inspection, 28 February 2012.
- Built
- 1993
- Last inspected
- 28 February 2012
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 19 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9003299 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
P3NV5
402646
Flag
CYPRUS
—
Maury page id
psix-402646
Inspections, by type
…with no type recorded10
Years with a record
9 calendar years (1998–2012)
The 21 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it30526 - Convention (Subpart B), Gross Ton
34062 - Dead Weight, Ton
47759 - Displacement, Ton
12512 - Convention (Subpart B), Net Ton
34062 - Dead Weight, Ton
47759 - Displacement, Ton
12512 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 21
28 February 2012
Random ISPS/MTSA/PSC
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4252487
19 January 2012
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4223526
23 August 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4122658
11 February 2011
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3943390
6 December 2010
ISPS II Exam · PII Safety Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3905554
29 November 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3900844
2 April 2009
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3444726
15 May 2004
MARPOL Annex I Examination · MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2068158
4 March 2004
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2018283
18 April 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1776236
5 April 2003
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1768590
12 February 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1743430
3 February 2003
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1738975
6 November 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1702465
6 November 2002
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1702523
6 November 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1702530
22 April 2002
Annual Inspection · Passenger/Freight Vessel Examination · MARPOL Annex I Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1607894
16 May 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 290083
27 November 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 423080
25 November 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 422949
23 February 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 413074
Deficiency record · 19
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 6 December 2010
Resolved
The vessels visual alarm for the fire detection system is not working in the Engine Room.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 December 2010
Resolved
There are multiple light indicators broken and not working in the Engine Room, causing a shock hazard.
Engineering › Compressed Air System (start air) › Piping
Issued 6 December 2010
Resolved
There is a temporary drain hose connecting two permanently fixed pipes between the ship service air compressor and bilge. Vessel must rectify the deficiency to the satisfaction of the Classification Society. SOLAS 74 (2004 Cons) Ch.I/11
Construction/Loadline › Hull › Side Shell
Issued 6 December 2010
Resolved
The vessel has a large dent in the hull located on the starboard quarter by the oil settling tank and a smaller dent on the port quarter. Deficiency must be rectified to the satisfaction of the Classification Society. ICLL 66 Annex I/1
Engineering › Compressed Air System (control) › Compressor
Issued 2 April 2009
Resolved
Ship service air compressors spraying oil on deck outside of combing creating a potential fire hazard, and slipping hazard.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 2 April 2009
Resolved
Ship service generators turbo oil drain line leaking onto running generators turbo intake compressor side creating a fire hazard due to the leaking on hot surfaces.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 15 May 2004
Resolved
CO2 System inoperable, unable to clear Low Pressure system low pressure alarm.
Lifesaving › Rescue Boat › Hull (inflated)
Issued 15 May 2004
Resolved
Rescue boat is not in serviceable condition, not holding air.
Navigation › Collision/Grounding Avoidance
Issued 5 April 2003
Resolved
Vessel provided information that during a routine test of emer. genartor under load while at sea one of the vessel's marine radar faulted LEGACY COMPONENT DESC: Radar
Operations/Management › Vessel Safety Management
Issued 6 November 2002
Resolved
ISM Code 10.1 - Nonconformity: Parts requested to effect repairs on vessel are not being provided in a timely fashion with delays of six to nine months. LEGACY COMPONENT DESC: Company Responsibilities/Authority
Engineering › Steering Gear System
Issued 6 November 2002
Resolved
SOLAS 74 (amended) CH II-2, REG 2.1 - Steering gear #1 and #2 pumps leaking excessively into drip pan full of hydraulic oil, temporary cans being used to store hydraulic oil.
LEGACY COMPONENT DESC: Pump
Construction/Loadline › Penetrations
Issued 6 November 2002
Resolved
ILLC 66, Annex 1/22 - Sea valves and piping for the salt water cooling system in poor repair with non-functioning handles, and a hole in the piping. LEGACY COMPONENT DESC: Valve Flange
Engineering
Issued 6 November 2002
Resolved
SOLAS 74 (amended) CH II-2, REG 15.2 - Multiple leaks in hydraulic and fuel oil systems throughout the vessel.
Engineering › Steering Gear System
Issued 6 November 2002
Resolved
Severe leaks on entire steering gear system. Suspect that pump #1 is not operating at capacity.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 6 November 2002
Resolved
#3 Cylinder fuel injector leaking - temporary hoses are currently draining fuel oil to a bucket next to the cylinder. LEGACY COMPONENT DESC: Injector (fuel injection)
Engineering › Sea-water System (primary cooling) › Valve
Issued 6 November 2002
Resolved
Shut off valve on discharge piping of SW cooling system is completely corroded at the flange (port side). SW piping on SSDG cooling system (STBD) is also wasted and being held in place with a makeshift clamp. SW is leaking into the bilge at a steady rate from both valves.
Pollution Prevention/Response › Response Equipment
Issued 6 November 2002
Resolved
Numerous oil leaks noted througout the engine room. E/R: pumproom, drip pans, general houskeeping substandard.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 6 November 2002
Resolved
#3 cylinder to be inspected and repaired as needed in drydock no later than 30 Sep 03. LEGACY COMPONENT DESC: Injector (fuel injection)
Navigation
Issued 25 November 1998
Resolved
HYDRAULIC STEERING PUMP LEAKING FLUID EXCESSIVELY.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.