← All vessels
HORNBAY
HORNBAY is a 1990 freight ship. The Coast Guard has recorded 52 inspections since 2009, most recently in September 2020, along with 7 deficiencies and 11 operational controls.
Records from 2009 to 2020. Most recent: operational control imposed, 21 September 2020.
- Built
- 1990
- Last inspected
- 21 September 2020
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 7 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8802002 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ELML7
402695
Flag
LIBERIA
—
Maury page id
psix-402695
Inspections, by type
…with no type recorded13
Years with a record
11 calendar years (2009–2020)
The 52 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.
Documentation record
Tonnage as PSIX records it3866 - Convention (Subpart B), Net Ton
12887 - Convention (Subpart B), Gross Ton
12887 - Simplified, Gross Ton
3866 - Simplified, Net Ton
9096 - Dead Weight, Metric Ton
7844 - Displacement, Metric Ton
12887 - Convention (Subpart B), Gross Ton
12887 - Simplified, Gross Ton
3866 - Simplified, Net Ton
9096 - Dead Weight, Metric Ton
7844 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 52
21 September 2020
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7062486
24 August 2020
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7038338
29 May 2020
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6963671
12 May 2020
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6951824
11 May 2020
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6951826
18 August 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6782484
23 May 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6691690
5 February 2019
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6620032
29 July 2018
ISPS III Exam · Administrative Inspection · Ballast Water Examination · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6489324
14 June 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6443900
1 June 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6431509
16 May 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6415833
14 April 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6391405
16 March 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6373073
24 February 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6360794
6 February 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6350226
25 January 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6341613
9 January 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6334834
8 December 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6320837
17 November 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6308648
27 October 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6296021
6 October 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6282804
17 September 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6268280
24 August 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6250648
4 August 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6230601
4 August 2017
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6230616
20 July 2017
ISPS III Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6214663
14 July 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6208570
24 June 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6185049
3 June 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6164208
13 May 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6145253
12 March 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6103156
29 January 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6076198
18 January 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6076741
21 July 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5948719
18 July 2016
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5945104
25 May 2016
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5886336
25 January 2016
NPV Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5802914
7 January 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5792692
7 December 2015
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5776827
3 December 2015
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5775029
25 November 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5770542
11 November 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5761629
12 October 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5740845
23 June 2014
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4891384
9 February 2012
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4241706
7 February 2012
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4240333
3 February 2011
ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3938277
10 January 2011
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3923986
4 January 2011
Ballast Water Examination · PII Safety Exam · Administrative Inspection · ISPS I Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3920376
14 January 2010
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3663921
10 December 2009
Ballast Water Examination · Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3646727
Deficiency record · 7
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 20 July 2017
Resolved
All waste recepticles shall be constructed of non combustable materials...PSCO observed waste recepticles constructed of combustable materials in the ship's galley and on deck.
Engineering › Feedwater/Condensate Water System › Piping
Issued 20 July 2017
Resolved
Machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be... adequate for the service...intended. PSCO observed a steady, pressurized stream of water discharging from a rupture in a suction pipe from the boiler feed water tank.
Construction/Loadline › Markings › Load Line Mark
Issued 20 July 2017
Resolved
Load line markings and the deck line shall be painted white...on a dark back ground or black on a light back ground. PSCO observed that the load line and draft markings are not painted with contrasting color as required.
Engineering › Generator (propulsion-electric) › Wiring
Issued 20 July 2017
Resolved
Machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be...adequate for the service which they are intended. PSCO observed a broken temperature gauge hanging by the wire from its mounting position on the number 3 generator.
Operations/Management › Cargo Transfer/Lightering › Pre-transfer Inspection
Issued 25 January 2016
Resolved
74SOLAS(14)I/11(c) See General Information
Engineering › Fuel Oil Service System › Gauge
Issued 23 June 2014
Resolved
1499 The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found fuel oil pressure gauge inoperable on #1 and #3, and lube oil pressure gauge on #3 service generators. 74SOLAS(09 Cons) I/II(a).
Engineering › Lubricating Oil Service System › Piping
Issued 23 June 2014
Resolved
1499 The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Found Lube Oil suction line to the #2 Ship Service Generator to have a leaking temporary patch. SOLAS 74 (2009 cons) I/II(a)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.