COLD STREAM

COLD STREAM is a 1994 freight ship. The Coast Guard has recorded 42 inspections since 1994, most recently in April 2025, along with 32 deficiencies and 4 operational controls.

Records from 1994 to 2025. Most recent: inspection, 8 April 2025.

Built
1994
Last inspected
8 April 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9051791 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
402712
Flag
LIBERIA
—
Maury page id
psix-402712

Inspections, by type

…with no type recorded12
Years with a record 17 calendar years (1994–2025)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it15713 - Displacement, Metric Ton
8414 - Convention (Subpart B), Gross Ton
4542 - Convention (Subpart B), Net Ton
10086 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

NRC RELIANT Freight Barge · MISLE 46073 · 8 February 2008 · activity 3144134NRC RELIANT Freight Barge · MISLE 46073 · 6 February 2008 · activity 3142946

Inspection history · 42

8 April 2025 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8107992
4 September 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7995821
17 July 2023 PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7744392
12 January 2023 PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7620256
11 January 2023 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7619930
4 August 2022 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7522082
16 June 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7480320
13 June 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7475974
12 June 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7475310
24 February 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7401144
16 February 2022 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7397249
9 August 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7281199
8 January 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7121460
7 January 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7119854
20 July 2020 PSC B · COE-Administrative
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7011252
13 January 2020 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6882624
17 July 2018 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6481979
6 November 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6302168
6 December 2016 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6053462
27 July 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5949287
16 March 2010 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3696735
24 April 2009 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3460037
21 March 2009 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3430785
5 March 2009 Ballast Water Examination · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3427914
17 February 2009 Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3419239
18 August 2008 Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3302450
7 July 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3261153
11 June 2008 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3234137
28 May 2008 ISPS II Exam · Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3220525
18 February 2008 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3149817
8 February 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3144134
6 February 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3142946
4 February 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3139583
21 January 2003 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1733222
19 December 2002 Annual Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1720500
30 September 2002 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1682020
11 January 2002 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1477848
17 December 2001 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1473701
28 October 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 463220
14 June 1994 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 367646
31 May 1994 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 448955
21 March 1994 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 365389

Deficiency record · 32

03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 17 July 2023 Resolved
An embarkation ladder complying with the requirements of regulation 48.7 extending, in a single length, shall be provided at each launching station. The vessels embarkation ladder was inoperable and could not be lowered 74 SOLAS(97) III/11.7
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 July 2023
Resolved 18 July 2023
Resolution: Ships crew ordered and repaired embarkation ladder motor.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 11 January 2023 Resolved
All vessels must submit NOAAs within the time required in 33 CFR 160.212. Vessel did not submit a NOA for its arrival to Port Canaveral, Florida.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 11 January 2023
Resolved 11 January 2023
Resolution: Vessel captain submitted a NOA with the guidance of both the vessels agent and PSC personnel.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 24 February 2022 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. PSC EXAMINERS OBSERVED EXCESSIVE AMOUNTS OF WATER ACCUMULATED IN THE ENGINE ROOM BILGE WELL. THERE WAS NO INDICATION OF THE SOURCE OF THE WATER.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2022
Resolution: Sector Delaware Bay recieved class report attesting to Engine room condition. Additonally a PSC B was conducted refrence activity #7475974
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 February 2022 Resolved
WHERE "A" CLASS DIVISIONS ARE PENETRATED FOR THE PASSAGE OF ELECTRICAL CABLES, ARRANGEMENTS SHALL BE MADE TO ENSURE THAT THE FIRE RESISTANCE IS NOT IMPAIRED. PSCE OBSERVED IMPROPER INSUALTION OF PENETRATION IN THE EMERGENCY GENERATOR ROOM. THE PENETRATION WAS FILLED WITH ALUMINUM FOIL, IMPAIRING ITS FIRE RESISTANCE.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 June 2022
Resolution: Vessel satisfactorily demonstrated to PSC personnel onboard on 13JUN22 that the fire boundary was intact.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 8 January 2021 Resolved
"Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use." Port side lifeboat steering gear inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 January 2021
Resolved 8 January 2021
Resolution: Ships crew rectified steering system on the spot back to fully operational.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 July 2020 Resolved
Operational Readiness: Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Lifeboats have no means of releasing winch brake from inside cabin.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2020
Resolved 28 July 2020
Resolution: Ship's force made brake available from inside lifeboat cabin.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 July 2020 Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO's observed clogged lines on the main engine preventing drainage to tank.
Action required: 10 - Deficiency Rectified
Due 28 July 2020
Resolved 28 July 2020
Resolution: Ship's force unclogged lines allowing proper drainage.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 July 2020 Resolved
Doors found in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. PSCO's observed the fire door leading to the steering gear room was unable to self close.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 28 July 2020
Resolution: Ship's force adjusted doors to allow for self closure.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 13 January 2020 Resolved
Guard rails fitted on superstructure and freeboard decks shall have three courses where necessary for the normal operation of the ship, steel wire ropes may be accepted in lieu of guard rails. Near the lifeboat embarkation area, 2 of the courses were comprised of polypropylene line and not steel wire ropes. ICLL (88 proto)25.3 - 40a
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 February 2020
Resolved 20 July 2020
Resolution: Vessel submitted class report clearing the def.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 January 2020 Resolved
Each section of sprinklers shall be capable of being isolated by one stop valve only. Port State Control Officers observed dripping from the sprinkler head in the paint locker. 74SOLAS(81 Amend) II-2/12.2.2 - 40a
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 February 2020
Resolved 20 July 2020
Resolution: Vessel submitted class report clearing the def.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 7 November 2017 Resolved
All waste recepticles shall be constructed of non combustible material with no opening in the sides or bottom. PSCO observed all waste receptacles on the stern ere plastic. 74SOLAS97(CONS)II-2/18.5
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 12 December 2017
Resolution: Received class report attesting to the proper waste receptacles being used onboard.
Construction/Loadline › Markings › Load Line Mark
Issued 6 November 2017 Resolved
The ring, liness and letters shall be painted...in black on a light background. PSCO observed all markings were blue. ICLL 66 Annex I/8
Condition: Invalid
Due 7 November 2017
Resolved 12 December 2017
Resolution: Received class report attesting to the proper coloring of the load lines.
Deck/Cargo › Cargo Stowage › General
Issued 28 July 2016 Resolved
Cargo, cargo units, and cargo trasnport units shall be so packed and secured within the unit as to prevent, throughout the voyage, damage or hazard to the ship and the persons on board. 04 Contianers found to be unserviceable per CSC/CIRC 138, had containers stacked on top. No SMS procedures, or documentation for use of out of service containers in stowage plan was provided. 74SOLAS(14)VI/5.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 9 December 2016
Resolution: Containers were removed from the vessel.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 27 July 2016 Resolved
The normal equipment of every lifeboat shall consist of: a food rationing totaling not less than 10,00 Kj for each person the lifeboat is permitted to accomdate. PSCO found 17 defective rations. 74 SOLAS (97 cons) ch. III/reg41.8.12
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 27 July 2016
Resolved 27 July 2016
Resolution: Vessel purchased and presented 18 new food rations to PSCO.
Deck/Cargo › Cargo Stowage › General
Issued 27 July 2016 Resolved
Cargo, cargo units, and cargo trasnport units shall be so packed and secured within the unit as to prevent, throughout the voyage, damage or hazard to the ship and the persons on board. PSCO found 04 containers, opened and stacked with other containers on top of them compromising their structural integrity, thus posing as safety hazards to ship persons on board. 74 SOLAS (2014) VI/5.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 27 July 2016
Resolved 28 July 2016
Resolution: Vessel removed containers that had been previously stacked on top of out of service containers, found to be in poor condition.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 17 February 2009 Resolved
2545- SOLAS 74 Ammended Ch. IX / ISM Code Reg. 9,10- When looking into vsl's SMS for reports identifying contamination of oil into #4 Port Ballast water tank(PBWT) no documentation onboard states any appropriate corrective actions have/were taken in accordance with SMS. Vsl showed proof of notification to company and initial response from company dating 12 Jun 2007. Recommend audit of ISM by R.O
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2009
Resolution: Initial R.O. identified issues have been handled with training and meetings. R.O. recommended additional audit after 90 days.
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 17 February 2009 Resolved
2550- Solas 2004 Cons. Ed. Ch. IX reg. 3/ ISM Code Reg. 9, 10 - Vessel is unable to take accurate soundings of their Ballast Water tanks due to multiple sounding tubes being blocked. In accordance with the vessel's SMS sounding of the tanks should be taken daily. The vessels class society and R. O. is to attest to the condition of the sounding tubes to allow proper soundings to be made.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2009
Resolution: Training and meetings held as per R.O. Future soundings will be taken accurately and any problems with soundings in future will result in an event being reported to the company. Sounding tubes cleared enough for soundings to be conducted.
Operations/Management › Ballast Water Managment › Extraordinary Condition Claims
Issued 17 February 2009 Resolved
1725- MARPOL 2006 Cons. 1/11- Oil contamination found in #4 Port B.W.T. Sounding tube blocked 1.3 meters above the strike. When plumb bob was retrieved fuel oil was found on it. Source of fuel contamination determined to be #5 Port F.O. tank . Class to attest to proper repair and cleaning of ballast water tank.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2009
Resolution: #4 Port BWT intial cleaning completed. Class attested to #4 Port BWT is isolated from Ballast Water System, remainder of B.W. system checked for contamination. #5 Port F.O. tank emptied & isolated. Condition of class put on vessel until 12 March 2009.
Engineering › Thrusters › Pump
Issued 28 May 2008 Resolved
Excessive oil was found an and around bow thruster pump. Vessel needs to maintain and keep general cleanliness of all equipment on the vessel.
Due 28 May 2008
Resolved 28 May 2008
Resolution: Corrected on the spot to the satisfaction of the port state control inspector.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 28 May 2008 Resolved
"A" Boundary Galley service doors have non automatic release hold back installed "A" fire boundary door to galley closure devices was removed and door would not latch. Repair self closing door and service doors to the satisfaction of class.
Action required: 705 - Other - as specified
Due 4 June 2008
Resolved 13 June 2008
Resolution: Received class report addressing the completion of repairs.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 28 May 2008 Resolved
Lifeboat starboard side rudder was not moving to port during steering test. Initially the unit moved to port and then seized in that position during all further attempts to steer to starboard. Have Coast Guard attest to proper operation of steering system prior to departure.
Due 28 May 2008
Resolved 28 May 2008
Resolution: Witnessed satisfactory steering test.
Deck/Cargo › Holds/Tanks › Coaming
Issued 28 May 2008 Resolved
Cover plating on cargo hold hatch coaming wasted/ cracked on all holds. Class must attest to repairs.
Action required: 705 - Other - as specified
Due 27 June 2008
Resolved 13 June 2008
Resolution: Received class report addressing the completion of repairs.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 28 May 2008 Resolved
Cargo holds 2 and 4 stiffeners are cracked at base. Class must attest to repairs.
Action required: 705 - Other - as specified
Due 27 June 2008
Resolved 13 June 2008
Resolution: Received class report addressing the completion of repairs.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 28 May 2008 Resolved
Handrail leading to fore castle port and starboard side broken. Class must attest to repairs.
Action required: 705 - Other - as specified
Due 27 June 2008
Resolved 13 June 2008
Resolution: Received class report addressing the repairs.
Electrical › Electrical Distribution System (service)
Issued 19 December 2002 Resolved
Properly support wire runs in forecastle. LEGACY COMPONENT DESC: Wiring
Action required: 15 - Rectify deficiencies by next port
Due 19 December 2002
Resolved 21 January 2003
Electrical › Lighting (service)
Issued 19 December 2002 Resolved
Repair electrical light fixtures in forecastle. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 15 - Rectify deficiencies by next port
Due 19 December 2002
Resolved 21 January 2003
Fire Fighting › Combustible Materials › Ceilings
Issued 19 December 2002 Resolved
Remove flammables from above sprinkler heads in paint locker.
Action required: 15 - Rectify deficiencies by next port
Due 19 December 2002
Resolved 19 December 2002
Fire Fighting › Structural - B Class Divisions
Issued 19 December 2002 Resolved
Replace fire doors between galley and crew mess areas. LEGACY COMPONENT DESC: Openings - Doors
Action required: 15 - Rectify deficiencies by next port
Due 19 December 2002
Resolved 21 January 2003
Fire Fighting › Combustible Materials
Issued 19 December 2002 Resolved
Remove flammables from unprotected storage containers on deck.
Action required: 15 - Rectify deficiencies by next port
Due 19 December 2002
Resolved 21 January 2003
Fire Fighting › Miscellaneous Items
Issued 24 December 2001 Resolved
PROVIDE VESSELS NAME AND CALL SIGN ON FIRE CONTROL PLAN
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 24 December 2001
Deck/Cargo › Cargo Transfer (solid)
Issued 17 December 2001 Resolved
CARRYOUT INSPECTION AND MAINTENANCE PROCEDURES IAW CARGO SECURING MANUAL
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 11 January 2002
Resolution: Cargo transfere manual updated for current usage to include required check-off list. Activity #1473701
Pollution Prevention/Response › Prevention Equipment
Issued 17 December 2001 Resolved
UPDATE OIL TRANSFER PROCEDURES TO REFLECT CURRENT OPERATIONS
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Resolved 11 January 2002
Resolution: Cargo transfere manual updated for current usage to include required check-off list. Activity #1473701

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.