EXTENDED HORIZONS II

EXTENDED HORIZONS II is a 1994 passenger vessel (inspected). The Coast Guard has recorded 48 inspections since 1994, most recently in August 2023, along with 58 deficiencies and 2 casualty investigations between 2003 and 2023.

Records from 1994 to 2023. Most recent: inspection, 9 August 2023.

Built
1994
Last inspected
9 August 2023
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCH4608
402727
Flag
UNITED STATES
—
Maury page id
psix-402727

Inspections, by type

…with no type recorded10
Years with a record 26 calendar years (1994–2023)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)32.5 ft × 9.8 ft × 5.8 ft
Registered tonnagegross 12 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMUNSON MANUFACTURING · EDMONDS, WA, UNITED STATES · built 1994
Hull materialAluminum
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portLAHAINA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 48

9 August 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7770000
9 August 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7787950
26 April 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7675721
24 January 2023 Construction Oversight · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7632860
7 June 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7471130
17 February 2022 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7401736
4 October 2021 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7326703
27 April 2021 Drydock Exam · Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7183566
10 June 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6973134
12 June 2019 Internal Structural Exam · Drydock Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6712318
7 June 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6437360
21 June 2017 Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6180899
11 May 2016 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5874580
17 June 2014 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4890805
11 June 2012 Deficiency Check · Internal Structural Exam · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4340941
3 March 2010 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3689552
10 February 2010 Deficiency Check · DAPI Audit · Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3678120
21 April 2008 Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3189413
12 April 2007 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2906921
3 April 2007 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2900844
29 September 2006 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2790206
7 June 2006 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2672728
12 May 2006 Hull Examination · Simplified Stability Test
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2647779
24 May 2005 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2367129
15 June 2004 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2099511
5 May 2004 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2056415
13 February 2004 Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2006270
21 January 2004 Type not recorded
No type recorded · USCG Oceania District (dre) · USCG Oceania District (CGD-O) · Activity 1989914
26 November 2003 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1955093
29 October 2003 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1939194
29 October 2003 Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 1939350
30 May 2003 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2006383
17 April 2002 Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1606511
9 May 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1064937
4 May 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1370148
24 April 2000 Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1365720
22 April 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1381558
7 December 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 63067
3 April 1998 Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1381186
15 May 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1364148
8 August 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1088611
24 July 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1091919
21 June 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1081252
1 May 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1359105
5 April 1996 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1421110
5 April 1995 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355210
1 June 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1414308
12 April 1994 Hull Examination · Inclining Experiment · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 857833

Deficiency record · 58

11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 April 2023 Resolved
Each rescue boat must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. Life float on board vessel has worn Type II retroreflective material. Add/replace retroreflective type material on life float. 46 CFR 185.604(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2023
Resolved 3 May 2023
Resolution: Retro tape provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 April 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Wiring for antenna cracked and wasted. Provide new wiring. 46 CFR 183.200 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2023
Resolved 3 May 2023
Resolution: New wiring provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 June 2022 Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The fuel shut off valve did not fully close when activated from outside the space. Adjust fuel valve cable to ensure full closure of valve when activated. 46 CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2022
Resolution: Fuel shut off operational.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 7 June 2022 Resolved
A complete application for an original MMC must contain proof, documented on CG-719-K or CG-719-K/E, as appropriate, that the applicant passed all applicable vision, hearing, medical, and/or physical exams as required by subpart C of this part or a valid medical certificate issued by the Coast Guard. The Master did not have his medical certificate available. 46CFR184.420(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2022
Resolution: MMC medical certificate provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 June 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Charts on board where not up-to-date. 46 CFR 16.401 (b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 13 June 2022
Resolution: Nav pubs provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 June 2022 Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisor personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. EAP supervisor did not have proper training. 46 CFR 16.401 (b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 13 June 2022
Resolution: EAP Training provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 June 2022 Resolved
In systems and application where flexible hoses are permitted to be clamped double hose clamping is required where practicable. Several hoses only had one hose clamp in place. Add second hose clamps. 46 CFR 182.410 (d)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 8 June 2022
Resolution: Double hose clamps provided.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 7 June 2022 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. The main deck of vessels has pitting exceeding 25% in multiple areas. Submit a repair proposal to be reviewed and approved by the attaining USCG Marine Inspector. 46 CFR 177.300
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 11 July 2022
Resolution: Repair proposal permitted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 June 2022 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. The aft port side bimini bracket is cracked. Submit a repair proposal to be reviewed and approved by the attaining USCG Marine Inspector. 46 CFR 177.300
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 13 June 2022
Resolution: Bimini repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 October 2021 Resolved
Port side hull cracked where drydock block/jack stand was placed during drydock. Crop and renew damaged area.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 November 2021
Resolution: Area repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 April 2021 Resolved
Discharge end of fuel tank vent pipe had screen that was not 30 x 30 mesh. Provide 30 x 30 mesh screen for discharge end of fuel tank vent pipe.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 3 May 2021
Resolution: 30 x 30 mesh installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 April 2021 Resolved
Port side engine bellows that covers u-joint holed. Replace bellows.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 3 May 2021
Resolution: New bellows installed.
Stability › Watertight Integrity › General
Issued 11 June 2012 Resolved
Prove fwd hatch and machinery space hatches watertight.
Action required: 705 - Other - as specified
Due 29 June 2012
Resolved 19 November 2012
Navigation › Piloting/Steering › Compass Deviation Table
Issued 10 February 2010 Resolved
Vessel does not have compass deviation table. Obtain and post deviation table onboard vessel.
Due 10 March 2010
Resolved 1 March 2010
Navigation › Piloting/Steering › Magnetic Compass
Issued 10 February 2010 Resolved
Compass light was disconnected and inoperable. Repair compass light. Vessel restricted to daylight operations only until discrepancy is repaired.
Due 10 March 2010
Resolved 1 March 2010
Engineering › Bilge Water Management System › Not Operational
Issued 10 February 2010 Resolved
Automatic bilge pumps do not operate in automatic mode. Repair bilge pumps to normal operating condition.
Due 17 February 2010
Resolved 12 February 2010
Construction/Loadline › Hull › Hull Plating
Issued 10 February 2010 Resolved
Vessel had 3 pitted areas in fwd peak under anchor line stowage area. Clad weld pitted areas to the satisfaction of attending marine inspector.
Due 10 March 2010
Resolved 1 March 2010
Lifesaving › Lifefloat › Serviceable
Issued 3 April 2007 Resolved
Renew as original lifefloat strap for lifelines. Strap fractured when tested.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 May 2007
Resolved 17 April 2007
Fire Fighting › Combustible Materials › Insulation
Issued 3 April 2007 Resolved
Remove flammable insulation from around wiring in the bulkhead between in the forward bilge space and the engine room.
Action required: 705 - Other - as specified
Due 2 May 2007
Resolved 13 April 2007
Navigation › Piloting/Steering › Marine Charts
Issued 7 June 2006 Resolved
Provide current and corrected charts of large enough scale for safe navigation of the area of operation.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 July 2006
Resolved 31 July 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 June 2006 Resolved
Provide a wire splint for the first aid kit, per 46 CFR 160.041.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 July 2006
Resolved 31 July 2006
Lifesaving › Lifefloat › Lifeline
Issued 7 June 2006 Resolved
Replace lifelines and retro-reflective tape as needed on lifefloat.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 July 2006
Resolved 31 July 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 May 2006 Resolved
Failure to operate with a valid COI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2006
Resolved 12 May 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 May 2006 Resolved
Failure to make vessel availible for drydock examination and internal structual exam as required by this section.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2006
Resolved 12 May 2006
Lifesaving › Hand Flares
Issued 5 May 2004 Resolved
Provide 3 orange smoke flares. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Due 19 May 2004
Resolved 15 June 2004
Operations/Management › Drug and Alcohol Testing
Issued 5 May 2004 Resolved
Provide training for supervisors. LEGACY COMPONENT DESC: EAP Training Requirements
Condition: Unknown
Due 19 May 2004
Resolved 15 June 2004
Accommodation/Occupational Safety
Issued 4 May 2001 Resolved
Provide 30x30 mesh flame screen for MSD discharge vent nlt 15MAY01.
Condition: Unknown
Due 4 May 2001
Resolved 4 May 2001
Lifesaving
Issued 4 May 2001 Resolved
Provide life float in a float free arrangement nlt 15MAY01.
Condition: Unknown
Due 4 May 2001
Resolved 4 May 2001
Navigation
Issued 4 May 2001 Resolved
Provide Coast Guard Light List and Coast Pilot nlt 15MAY01.
Condition: Unknown
Due 4 May 2001
Resolved 4 May 2001
Fire Fighting
Issued 22 April 1999 Resolved
Provide proof of NFPA 10 servicing to portable fire extinguishers.
Condition: Unknown
Due 22 May 1999
Resolved 8 June 1999
Fire Fighting
Issued 1 May 1996 Resolved
Provide one B-I portable fire extinguisher at the steering station in accordance with 46 CFR 181.30-1(a)._x001C_
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Engineering
Issued 1 May 1996 Resolved
Provide bonding wire for fuel tank fill pipe in accordance with 46 CFR 182.20-30(d).
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Lifesaving
Issued 5 April 1996 Resolved
Post PFD placards in accordance with 46 CFR 185.516.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Construction/Loadline
Issued 5 April 1996 Resolved
Install high level bilge alarms in the engine room and sewage tank space. Alarm shall be audible and visual at the helm.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Accommodation/Occupational Safety
Issued 5 April 1996 Resolved
Properly label the MSD overboard valve.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996 Resolved
Conduct and log crew training in accordance with 46 CFR 185.420.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Electrical
Issued 5 April 1996 Resolved
Provide portable lights in accordance with 46 CFR 183.430.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Navigation
Issued 5 April 1996 Resolved
Post a radio emergency broadcast placard in accordance with 46 CFR 184.506.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Navigation
Issued 5 April 1996 Resolved
Provide a code Alpha flag.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Electrical
Issued 5 April 1996 Resolved
Wiring installation for the high level bilge alarms must comply with 46 CFR183.340.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Construction/Loadline
Issued 5 April 1996 Resolved
Replace plastic through hull fittings with metallic fittings.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996 Resolved
Conduct and log monthly maintenance of the survival craft in accordance with 46 CFR 185.722.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Engineering
Issued 5 April 1996 Resolved
Install 30x30 corrosion resistant wire mesh flame screen in the fuel tank vent line.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996 Resolved
Conduct passenger safety orientation in accordance with 46 CFR 185.506.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996 Resolved
Conduct and log abandon ship and man overboard drills and training in accordance with 46 CFR 185.520.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Fire Fighting
Issued 5 April 1996 Resolved
Conduct and log fire fighting drills and training in accordance with 46 CFR185.524.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996 Resolved
Properly label all lifesaving equipment in accordance with 46 CFR 185.604.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Construction/Loadline
Issued 5 April 1996 Resolved
Properly label the watertight hatches in accordance with 46 CFR 185.610.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996 Resolved
Provide a suitable container for the distress signals in accordance with 46CFR 185.614.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996 Resolved
Provide manufacturer maintenance and inspection instructions for the survival craft in accordance with 46 CFR 185.702.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 5 April 1996 Resolved
Conduct and log weekly maintenance and inspection of the survival craft in accordance with 46 CFR 185.720.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Fire Fighting
Issued 12 April 1994 Resolved
Install portable fire extinguishers (1 BI and 1 BII) onboard vessel.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Construction/Loadline
Issued 12 April 1994 Resolved
Install chain to midship compartment watertight hatch and connect it to hull.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Unknown
Issued 12 April 1994 Resolved
Provide radio telephony certificate after receipt from FCC. Paperwork was provided that proved that inspection was ordered from operator/owner._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Navigation
Issued 12 April 1994 Resolved
Provide Deviation table for magnetic compass for area in which vessel is tooperate.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Lifesaving
Issued 12 April 1994 Resolved
Properly stencil "8 PERSON CAPACITY" on life float._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Lifesaving
Issued 12 April 1994 Resolved
Stow paddles on or near lifefloat.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Electrical
Issued 12 April 1994 Resolved
Provide 2 flashlights or other means for emergency lighting.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994

Casualty record · 2

30 May 2003Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2006383
9 August 2023Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7787950
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.