Records from 1995 to 1998. Most recent: inspection, 24 June 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
24 June 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 416671
4 June 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 416648
4 June 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1127207
6 December 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 712945
4 December 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 398166
4 December 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1097088
22 November 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 156099
18 November 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 397507
11 August 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 381739
8 August 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 381083
22 February 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 375367
22 February 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 521543
Construction/Loadline
Issued 4 June 1998
No resolution recorded
VESSEL'S BILGE PUMP PIPING FOR MACHINERY SPACES GOES DIRECTLY OVERBOARD ANDHAS A SOFT PATCH ON ITS DISCHARGE. VESSEL MUST REPAIR/RENEW AND PROVIDE CLASS REPORT ON WHY PIPING FOR MACHINERY SPACE DOES NOT GO THROUGH OILY WATER SEPERATOR SYSTEM PRIOR TO RETURNING TO U.S. WATERS.
Condition: Unknown
Due 29 June 1998 — due date passed with no resolution recorded
Engineering
Issued 4 June 1998
No resolution recorded
BUNKER PIPING OVER DUE FOR HYDROSTATIC TEST. HYDRO BUNKER PIPING AT 1 1/2 MAWP PRIOR TO BUNKERING IN U.S. WATERS, PROVIDE DOCUMENTATION.
Condition: Unknown
Due 30 June 1998 — due date passed with no resolution recorded
Deck/Cargo
Issued 4 June 1998
No resolution recorded
SEVERAL OF THE HIGH LEVEL ALARM SENSORS SHOW 98% FULL INCORRECTLY. REPAIR/RENEW AND PROVIDE CLASS REPORT STATING SYSTEM OPERATES PROPERLY.
Condition: Unknown
Due 30 June 1998 — due date passed with no resolution recorded
Fire Fighting
Issued 4 June 1998
No resolution recorded
VESSEL'S MAIN FIRE PUMP ON PORT SIDE SUCTION PIPE HAD CEMENT PATCH. VESSELMUST REPAIR/RENEW AND PROVIDE CLASS REPORT PRIOR TO RETURN U.S. WATERS.
Condition: Unknown
Due 29 June 1998 — due date passed with no resolution recorded
Engineering
Issued 4 June 1998
No resolution recorded
DRAIN VALVE ON PORT FUEL TANK HAD HOSE CONNECTED TO FUEL OIL PURIFIER. REPAIR/RENEW AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 30 June 1998 — due date passed with no resolution recorded
Electrical
Issued 4 June 1998
No resolution recorded
VESSEL HAS A TEMPORARY HOSE ATTACHED TO THE AC PUMP FOR COOLING THE PRIME MOVER. THE INSTALLED PUMP ON PRIME MOVER WAS REMOVED. REPAIR/RENEW PROVIDE CLASS REPORT.
Condition: Unknown
Due 30 June 1998 — due date passed with no resolution recorded
Electrical
Issued 18 November 1996
Resolved
Temporary repairs made to the #3 s/s generator salt water cooling line leaking. SOLAS 74 REG 1/11.
Condition: Unknown
Due 10 January 1997
Resolved 10 January 1997
Construction/Loadline
Issued 18 November 1996
Resolved
Load line markings not painted in contrasting colors. ILLC 66 Annex I/8.
Condition: Unknown
Due 10 January 1997
Resolved 10 January 1997
Construction/Loadline
Issued 18 November 1996
Resolved
Watertight doors on main deck do not seal properly. Need to be adjusted/replaced as needed. ILLC 66 Annex I/12.
Condition: Unknown
Due 10 January 1997
Resolved 10 January 1997
Electrical
Issued 18 November 1996
Resolved
Excessive lube oil leaking from the #6 cylinder on the #1 s/s generator. SOLAS 74 REG 1/11.
Condition: Unknown
Due 10 January 1997
Resolved 10 January 1997
Deck/Cargo
Issued 18 November 1996
Resolved
Deck cargo steam piping/heat shielding is in poor condition/wasted. SOLAS 74 REG 1/10.
Condition: Unknown
Due 10 January 1997
Resolved 10 January 1997
Fire Fighting
Issued 18 November 1996
Resolved
Emergency fire pump pressure (10 psi at discharge side of pump) is inadequate. SOLAS 74 REG II-2/52.
Condition: Unknown
Due 10 January 1997
Resolved 10 January 1997
Lifesaving
Issued 18 November 1996
Resolved
Port and starboard lifeboats davits are not equipped with limit switches. SOLAS 74 REG III/36.
Condition: Unknown
Due 10 January 1997
Resolved 10 January 1997
Deck/Cargo
Issued 18 November 1996
Resolved
Vessel is not equipped with overfill devices in accordance with 33 CFR 155.480.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Lifesaving
Issued 8 August 1995
Resolved
SERVICE 25 MAN LIFERAFT.
Condition: Unknown
Due 16 August 1995
Resolved 16 August 1995
Lifesaving
Issued 8 August 1995
Resolved
MAKE PROPER REPAIRS TO FORECASTLE RAILING PORT SIDE.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996