THE MARGARET MARY is a 1994 passenger vessel (inspected). The Coast Guard has recorded 178 inspections since 1994, most recently in February 2011, along with 277 deficiencies and 1 casualty investigation in 2009.
Records from 1994 to 2011. Most recent: inspection, 15 February 2011.
- Built
- 1994
- Last inspected
- 15 February 2011
- Documentation
- Not in the documentation file of 10 September 2026
- Inspections
- 178
- Deficiencies
- 277 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2009
Identity
1020786
402897
Flag
UNITED STATES
366962480, 367130120 (licence lapsed)
Maury page id
psix-402897
Inspections, by type
…with no type recorded93
Years with a record
18 calendar years (1994–2011)
The 178 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it1596 - Regulatory (Subpart C or D), Gross Ton
6425 - Convention (Subpart B), Gross Ton
1085 - Regulatory (Subpart C or D), Net Ton
1927 - Convention (Subpart B), Net Ton
1934 - Dead Weight, Ton
6425 - Convention (Subpart B), Gross Ton
1085 - Regulatory (Subpart C or D), Net Ton
1927 - Convention (Subpart B), Net Ton
1934 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WDD3361MMSI 367130120 · expired · compulsorily equipped · granted 27 April 2016, cancelled 22 August 2026
WCJ6222MMSI 366962480 · expired · compulsorily equipped · granted 8 July 2004, cancelled 13 September 2014 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 178
15 February 2011
MTSA Verification · Deficiency Check · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3946393
15 February 2011
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3949982
27 October 2010
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3879207
6 October 2010
Administrative Inspection · MTSA Verification · Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3865469
12 March 2010
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3694550
6 January 2010
Deficiency Check · MTSA Verification · Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3662160
29 December 2009
Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3656317
2 December 2009
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3644008
13 July 2009
In-Service Inspection · Administrative Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3540727
13 April 2009
Hull Examination · MTSA Verification · Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3453117
5 February 2009
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3412828
6 January 2009
Administrative Inspection · MTSA Verification · In-Service Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3396824
23 October 2008
In-Service Inspection · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3353667
29 July 2008
Internal Structural Exam · Deficiency Check · MTSA Verification · In-Service Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3302962
14 April 2008
COI Inspection · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3180469
16 January 2008
In-Service Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3137480
24 October 2007
In-Service Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3089167
6 September 2007
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3050524
12 April 2007
COI Inspection · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2906812
8 September 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2772899
12 July 2006
In-Service Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2710407
17 April 2006
MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2635827
12 April 2006
MTSA Verification · COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2623359
27 February 2006
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2592634
2 February 2006
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2578303
7 November 2005
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2544915
25 April 2005
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2342130
18 January 2005
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2285341
5 October 2004
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2225292
9 July 2004
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2127473
9 April 2004
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2040718
29 January 2004
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2005538
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979449
6 October 2003
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1917564
6 August 2003
Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1873531
28 July 2003
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1859930
15 April 2003
COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1773967
26 January 2003
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1735610
23 October 2002
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1696981
27 September 2002
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1681163
20 September 2002
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1678314
23 July 2002
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1650598
16 April 2002
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1604031
10 January 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1477655
10 October 2001
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1074507
25 July 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1457974
17 May 2001
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 700407
24 April 2001
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1470605
23 February 2001
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1059661
24 January 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1384669
12 January 2001
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 111889
12 October 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1373197
26 July 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1448163
9 June 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1050485
25 April 2000
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1408520
26 January 2000
Deficiency Check · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1464264
28 December 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 812399
27 October 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449253
29 July 1999
Deadweight Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1372706
26 July 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1372705
11 June 1999
Deadweight Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 809125
28 April 1999
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1432106
24 February 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 798272
25 January 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1459468
2 November 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1446698
17 August 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1404626
6 August 1998
Deficiency Check · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1472732
22 May 1998
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1126458
28 April 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1378360
14 March 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 101421
26 January 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1372110
6 November 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1428853
20 October 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 184146
16 August 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 68689
6 August 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1428815
30 June 1997
Deadweight Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 777939
10 June 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1111957
16 May 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 185727
6 May 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1464685
27 January 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1414741
25 November 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 173329
14 November 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 72302
11 November 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 137211
5 November 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1454378
8 October 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 49442
2 October 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 4301
12 September 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 956653
6 September 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 184240
4 September 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1251722
7 August 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1359226
10 July 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 114061
6 July 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 116108
6 July 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 132073
5 July 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 121902
29 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 112710
26 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 65568
19 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 43842
17 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 84393
6 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 172060
5 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 71330
5 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 113711
2 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 10358
2 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 119100
28 May 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 95219
27 May 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 67216
27 May 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 138267
14 May 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 152880
12 May 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 149221
6 May 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1407672
1 May 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 179541
24 April 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 40018
21 April 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 50745
21 April 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 112809
4 April 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 176061
25 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 112258
24 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 135380
18 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 154241
18 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 163985
17 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 49209
14 March 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396476
10 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 141074
9 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 6928
9 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 81776
3 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 136521
3 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 184888
29 February 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 139279
22 February 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 48376
19 February 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 167001
17 February 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 110491
12 February 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 115972
9 February 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 49873
30 January 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1380397
26 January 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 113354
26 January 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 152378
13 January 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 12174
5 January 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 157176
27 December 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 59505
16 December 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 166908
8 December 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425666
3 December 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 100195
26 November 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 105379
13 November 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 14217
13 November 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 48441
10 November 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 108645
9 November 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1355542
7 November 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 867866
27 October 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 27702
13 October 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 72513
4 October 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 44803
3 October 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 100746
3 October 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 161121
1 October 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 102726
29 September 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 26468
24 September 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 110661
23 September 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 38014
2 September 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 34094
2 September 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 60592
19 August 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 81673
16 August 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 135786
10 August 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1403994
30 July 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 178310
9 July 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 77722
7 July 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 158863
20 June 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 878985
23 May 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1380213
2 May 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 115408
13 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 14661
10 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 125183
29 March 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1363235
22 February 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1385393
17 November 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1387654
23 August 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1428379
15 June 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 872743
2 June 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1419271
20 May 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1438204
10 April 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1462389
8 April 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 177878
6 April 1994
Initial Construction-Excluding Oversight · Hull Examination · Initial Certification · Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443449
Deficiency record · 277
Fire Fighting › Ventilation Systems › Operating Controls
Issued 15 February 2011
Resolved
Manual fire dampers failed to operate when spot checked/tested 46CFR71.25-25(a)(3). Repair or replace all fire dampers.
Fire Fighting › Automatic Sprinkler System › Spare Sprinkler Heads
Issued 15 February 2011
Resolved
2nd Deck Portside VIP credit office, Replace missing ceiling tile then lower sprinkler head so it's properly positioned (BELOW) the false ceiling tile. 46CFR76.25-10
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 February 2011
Resolved
Found multiple missing clips on hand rail chains. Replace missing clips as needed thru out vessel peripheries. Install railing or chain and clips as necessary to comply with 46CFR72.40-5(a)
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 15 February 2011
Resolved
Found two non-marine electrical boxes being used in Main deck aft storage locker by paddle wheel 46CFR70.25-1. Remove electrical boxes and pull wires back to next junction box, 46CFR111.60-17(b) or replace the incorrect boxes with appropriate marine grade boxes 46CFR111.01-9(d).
Fire Fighting › Means of Escape › Blocked
Issued 15 February 2011
Resolved
Break room emergency escape is blocked. A chair was found on top off hatch in front of a slot machine. Carpet is not marked or protected to show area is an emergency escape hatch do not block.
Fire Fighting › Means of Escape › Doorways
Issued 15 February 2011
Resolved
Multiple fire screen doors in stair towers failed to latch once remotely released. Adjust doors so they comply with 46CFR72.05-25(b)(9)(ii)
Fire Fighting › Means of Escape › Doorways
Issued 15 February 2011
Resolved
Fire screen door #11 in stair tower will not latch back after testing remote release of door. Repair electric hold back device to comply with 46CFR72.05-25(b)(9)(ii) so it can automatically close in event of disruption to control system.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 15 February 2011
Resolved
Found missing IMO symbol stickers for multiple fire fighting and life saving equipment thru out vessel. Ensure all fire fighting and life saving IMO symbols and markings are in compliance with 46CFR78.47, 46CFR 78.47-45, 46CFR78.47-30 & 46CFR199.70
Personnel › Training › Safety Orientation
Issued 15 February 2011
Resolved
Noticed during fire drill Watch Quarter station bill and training didn't match the company's policy for responding to fires. Correct so Company policy, WQSB & Marine crew training all match. 46CFR78.13-1, 46CFR78.17-50, 46CFR199.80, 46CFR199.180(F)(2)(i)
Engineering › Compressed Air System (control) › Valve
Issued 15 February 2011
Resolved
Engine room air compressor relief valve failed to function when tested as required 46CFR71.20-20(c), 46CFR54.15-10(g). Repair or replace.
Engineering › Diesel Engine (auxiliary) › Cylinder Head
Issued 15 February 2011
Resolved
Emergency generator has a small fuel oil leak on top of engine, find and repair as needed. 46CFR71.25-45.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 15 February 2011
Resolved
Noticed a missing electrical receptacle outlet cover plate allowing electrical wires to be easily accessible 46CFR70.25-1, Replace manufacture cover plate 46CFR111.79-1(e) or remove outlet properly terminate wires in box and cover box to prevent electrical shock hazard 46CFR111.60-17(b).
Electrical › Lighting (emergency) › Lighting Fixture
Issued 6 January 2010
Resolved
Exit light in chiller room is missing. Repair or replace in accordance with 46CFR78.47-40.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 January 2010
Resolved
Life Jacket storage locker on deck 2 is not marked in accordance with 46CFR78.47-45. Check all life saving appliance lockers on the vessel to ensure they are properly marked.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 6 January 2010
Resolved
All trash cans shall meet 46CFR72.05-55(b) constructed of incombustible material. Please remove those trash cans which can't meet or your unable to prove they meet 46CFR72.05-55(b) or NVIC 9-97.
Fire Fighting › Fixed Fire Detection System › Manually Operated Call Points
Issued 13 July 2009
Resolved
Pulled one manual pull box on third deck 3 separate times but failed to energize alarm system. Tried another pull box on third deck no alarms sounded except in Pilot house. Went to second deck and pull one pull station and Fire Alarms sounded. Required a third party fire detection tech evaluate the problem.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 29 July 2008
Resolved
Clean deck of liquor and repair leaking liquid tray racks.
Engineering › Bilge Water Management System › Valve
Issued 29 July 2008
Resolved
Make operable, forepeak reach-rod and valve.
Construction/Loadline › Structures › Manhole
Issued 29 July 2008
Resolved
Make operable, bow-thruster space emergency escape hatch. Clean knife-edge, remove rust and replace gasket.
Fire Fighting › Remote Fuel Shutoff › General
Issued 29 July 2008
Resolved
Make operable, emergency fuel shut-off in emergency generator space (cable needs adjustment).
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 16 January 2008
Resolved
Recharge portable dry-chemical fire extinguisher located in the engineroom adjacent to watertight door #5.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 16 January 2008
Resolved
Adjust port fire damper in emergency generator space. Damper does not fully close completely.
Communications › Public Address System › Announcing Station
Issued 24 October 2007
Resolved
AVADS is not working on 1st and 2nd deck due to construction. Post fire watch on both decks until repairs are made.
Fire Fighting › Automatic Sprinkler System › Stop Valves
Issued 12 July 2006
Resolved
Install valves before and after the air supply regulator for the sprinkler system for the fire fighting.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 12 July 2006
Resolved
demonstrate proper operation of the fire detector in the surveilance room.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 17 April 2006
Resolved
Emergency generator ventilators shutters will not close fast enough to contain the release of CO2 discharge in the space to extinguish the fire. 1a. Submit plans to coast guard by 28 April 2006 on how to correct the problem with the ventilators shutters. 1b. If the emergency generator is operated a watch stander will be present.
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 17 April 2006
Resolved
replace all plastic trash can liner or submitt plans to correct or change.
Electrical › Electric Generation Source (emergency) › Generator
Issued 12 April 2006
Resolved
emergency generator ventilator shutters will not close fast enough to contain the CO2 system discharge.
Fire Fighting › Automatic Sprinkler System › Power Sources
Issued 2 February 2006
Resolved
AEVADS must have seperate msg indicating affected deck for emergency. Additionally, radio does not shut off when AEVADS is activated. System needs to be updated or replaced.
Accommodation/Occupational Safety › Potable Water System › General
Issued 2 February 2006
Resolved
Vsl needs to complete pulling all leer lines on board vsl. They are no longer used and are in wasted condition. (no sub-system for beer line).
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 2 February 2006
Resolved
Install door closure device on 1st deck door leading to breakroom.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 February 2006
Resolved
Light in emergency generator room need to be replaced.
Construction/Loadline › Structures › Door
Issued 25 April 2005
Resolved
WTD #67 in engine room access has a hole in the insulation inside eng rm side.
Deck/Cargo › Cargo Stowage › General
Issued 25 April 2005
Resolved
Arrange supplies and equipment to conform to 18" from ceiling height restriction in slot storage
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 April 2005
Resolved
Determine leak and submit repair proposal for slot storage bulkhead.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 25 April 2005
Resolved
Repair/plug holes in ceiling of emergency gen rm and engine room.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 25 April 2005
Resolved
Replace worn CO2 supply hoses (2) located in CO2 room.
Deck/Cargo › Cargo Stowage › General
Issued 25 April 2005
Resolved
Paint locker needs to be established IAW regs. Paint needs to be moved out of hold immediately.
Operations/Management › Drills/Instruction › Not Conducted
Issued 25 April 2005
Resolved
Procedures for suspicious package needs to be established and in writing.
Operations/Management › Drills/Instruction › Not Conducted
Issued 25 April 2005
Resolved
Produce confined space entry procedures and determine if confined spaces hace been designated IAW plan.
Accommodation/Occupational Safety › Ventilation › General
Issued 25 April 2005
Resolved
Replace AC filter in the aft crew lounge (lower deck) and replace lighting cover and light bulbs.
Deck/Cargo › Cargo Stowage › General
Issued 25 April 2005
Resolved
Place locks on all storage cabinets in rest rooms throughout vsl as a MTSA requirement.
Operations/Management › Passenger Operations › Safety Orientation
Issued 25 April 2005
Resolved
Produce procedures for the screening/authorization for private venders boarding vsl.
Construction/Loadline › Penetrations › Pipe Flange
Issued 25 April 2005
Resolved
Place insulation around pipes extending out of bulkheads/ceilings in the 2nd and 3rd deck (fwd) storage area and the emergency generator room.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 25 April 2005
Resolved
Provide an approval letter for ceiling tile being placed throughout vsl.
Deck/Cargo › Cargo Stowage › General
Issued 25 April 2005
Resolved
Remove all plastic mile crates from vsl.
Electrical › Electric Supply System (service) › Cable
Issued 25 April 2005
Resolved
Remove all old wires.
Engineering › Freshwater System (air cooling) › Discharge Strainer
Issued 25 April 2005
Resolved
Re-mount the "CLOSE DISCHARGE VALVE" placard in engine room.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 25 April 2005
Resolved
CO2 horn is behind all the recording banks and needs to be relocated to corner area IAW plan.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 25 April 2005
Resolved
Replace outlet cover on plug-in by door and duct tape around it. Current cover not correct one, replace with appropriate cover.
Construction/Loadline › Penetrations › Pipe Flange
Issued 25 April 2005
Resolved
Remove non-approved insulation and duct tape from vsl.
Construction/Loadline › Penetrations › Pipe Flange
Issued 25 April 2005
Resolved
Insure the two (2) bulkhead penetrations in the surveillance room (CCTV) are filled.
Lifesaving › Rescue Boat › Hull (rigid)
Issued 25 April 2005
Resolved
Repair one inch puncture on stbd (fwd) rescue boat. Puncture is located on the stbd bow 6" above water line.
Operations/Management › Drills/Instruction › Fire
Issued 18 January 2005
Resolved
Post new fire control plan throughout the vsl.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 18 January 2005
Resolved
Replace/replace wasted sections in bulkheads in AC chiller room.
Engineering › Freshwater System (air cooling) › Level Control
Issued 18 January 2005
Resolved
Replace missing butterfly handle in AC chiller room.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 18 January 2005
Resolved
Repair deck in women's restroom in fwd hold section.
Electrical › Electric Supply System (service) › Cable
Issued 18 January 2005
Resolved
Place boxes over wires on the liquor distribution system.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 18 January 2005
Resolved
Repair gap in bulkhead in surveillance room.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 5 October 2004
Resolved
98% of all external fire doors are worn/wasted half way up the door. Insulation is pushing through the rusted out holes in doors. All doors that are rusted must be replaced.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 5 October 2004
Resolved
New wires ran throughout vessel and new HVAC system install. Ceiling tile was moved around during this evolution. When ceiling tile was put back into place, sprinkler heads were not placed properly through the ceiling tile.
Construction/Loadline › Structures › Deck Plating
Issued 5 October 2004
Resolved
In beverage room located in lower hold, vsl has placed a water heater directly on the deck. Due to disimilar metals, the bottom of the water heater has rusted away, and has begun to rust away the deck plating. Required to replace water heater and place a protective layer between the deck and the water heater. Also have problem w/ CO bottles and a sound box. Need to place protective layer betwe
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 5 October 2004
Resolved
Checklist for a sercurity incident needs to be developed. It has been discovered that not all required persons are being notified when an incident occurs. Checklist to remind all personnel of who to contact needs to be developed. Checklist needs to include CSO, VSO and FSO.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 5 October 2004
Resolved
Update of training logs. When looked at, not all employees have recieved minimum required training in security. All departments will be trained IAW VSP and knowledge of CSO, VSO & FSO and MARSEC levels.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 5 October 2004
Resolved
AVEADS system message does not match the approved Emergency Evacuation Plan. Announcement has passengers proceed to lifejacket donning areas. Need to match plan and have passengers proceed to the nearest exit.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 July 2004
Resolved
While installing camera's and monitors for MTSA, the rock blocks were removed and/or damaged. Ensure installation of rock blocks IAW manufacter requirements.
Electrical › Electrical Distribution System (service)
Issued 9 April 2004
Resolved
Outlet boxes overlap in 3rd deck cage. Reinstall to not overlap. LEGACY COMPONENT DESC: Outlet Box
Electrical › Electrical Distribution System (service)
Issued 9 April 2004
Resolved
2nd deck credit office - remove power stripes and replace w/ UPS as per vessel plan. Continue to develope and implement maintenance plan for UPS installation on vessel.
Liquar room- remove power strip remove deadend wires;
Fire Fighting › Fire Hydrants
Issued 9 April 2004
Resolved
#6 fire station has a missing cap on the Y valve.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 April 2004
Resolved
Computer room has dead end wires, correct and install metal bands on wire runs. Install fire stop in penitrations through bulkhead.
Accommodation/Occupational Safety › Occupational Safety
Issued 9 April 2004
Resolved
Liquar room, replace or remove beer lines.
Engineering › Feedwater/Condensate Water System
Issued 9 April 2004
Resolved
Chiller room, gauge glass on chillers broke out when testing prior to CG inspection. Gauge is on order. LEGACY COMPONENT DESC: Gauge
Electrical › Electrical Distribution System (service)
Issued 9 April 2004
Resolved
Bow thruster room- mount or remove hanging outlet box. replace lightbulb; install instulation around stuffing box. LEGACY COMPONENT DESC: Outlet Box
Engineering › Generator (propulsion-electric)
Issued 9 April 2004
Resolved
Repair exhaust leak on generator #2 and #3. Repair overspeed on #1 Gen.
Construction/Loadline › Structures › Door
Issued 9 April 2004
Resolved
Repair WTD #7 alarm when shutting and shut. Alarm would not disengage after door was completely shut. When the door was bumped slightly open the alarm would shut off.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 April 2004
Resolved
Manual pull on CO 2 system located in emergency generator room failed. Part has been ordered and delivery to be within 24 hours. 24 hour fire watch to be posted until CO2 system is back online.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 29 January 2004
Resolved
Vessel needs to unclip all PFD's and restore them. Additionally, they need to restake locker on 2nd deck.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 29 January 2004
Resolved
Post lifejacket donning placard on upper deck. Vessel moved locker location and had not installed the donning placard.
Electrical › Electrical Distribution System (service)
Issued 29 January 2004
Resolved
Vessel had fabricated a plexiglass blank for the circuit breaker box. Need to replace with an proper blank cover. LEGACY COMPONENT DESC: Circuit Breaker
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 29 January 2004
Resolved
Find and repair ground on Ship service Generator Ammeter.
Construction/Loadline › Structures › Door
Issued 29 January 2004
Resolved
Gasket around WTD #9 and 10 needs to be replaced.
Electrical › Electrical Distribution System (service)
Issued 29 January 2004
Resolved
Remove all power stripes in all spaces on vessel. LEGACY COMPONENT DESC: Overcurrent Device
Fire Fighting › Nozzles › Condition
Issued 6 October 2003
Resolved
Fire station #16 nozzles needs to be exercised.
Fire Fighting › Structural - A Class Divisions
Issued 6 October 2003
Resolved
3rd deck bilge locker port side forward. Fix insulation on bulkhead in storage room. LEGACY COMPONENT DESC: Bulkheads - Store-rooms
Fire Fighting › Structural - B Class Divisions
Issued 6 October 2003
Resolved
2nd deck port side in life jacket locker. Repair insulation in back of space. LEGACY COMPONENT DESC: Bulkheads - Store-rooms
Electrical › Electrical Distribution System (service)
Issued 6 October 2003
Resolved
Panel S2-1A. Replace lock located on panel door. LEGACY COMPONENT DESC: Panelboard
Construction/Loadline › Structures
Issued 6 October 2003
Resolved
Replace label on emergency escape hatch 1st deck aft lounge. LEGACY COMPONENT DESC: Scuttle
Construction/Loadline › Structures
Issued 6 October 2003
Resolved
Replace gasket on escape hatch for bow thruster room. LEGACY COMPONENT DESC: Scuttle
Electrical › Electrical Distribution System (service)
Issued 6 October 2003
Resolved
Place metal bands around wires in all elevator shafts. LEGACY COMPONENT DESC: Conductor
Construction/Loadline › Structures
Issued 6 October 2003
Resolved
Move bilge alarm from chiller room to starboard bilge containment. LEGACY COMPONENT DESC: Bilge
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 6 October 2003
Resolved
Show proper operation of sprinkler pump discharge cutout alarm.
Operations/Management › Drills/Instruction › Fire
Issued 6 October 2003
Resolved
Conduct proper fire drill.
Deck/Cargo › Holds/Tanks
Issued 11 August 2003
Resolved
Potable water void under the liquar room is missing drain holes. Bilge system would only be able to drain only to the frame longitutinals. Vessel is required to submit plan for repairs. LEGACY COMPONENT DESC: Cargo Tank Drainage
Electrical › Electrical Distribution System (service)
Issued 6 August 2003
Resolved
Plastic zip ties were installed around wiring. Vessel needs to replace and/or install metal band around all wires throughout the vessel. Examples are engine room and elevator shaft. LEGACY COMPONENT DESC: Wiring
Electrical › Electric Generation Source (service)
Issued 6 August 2003
Resolved
Vessel needs to repair ground detection system at main switch board. When buttons are depressed to test for ground, nothing happens. System is locked up, continues to show 3-6 amps of current. LEGACY COMPONENT DESC: Ground Detection
Engineering › Bilge Water Management System
Issued 6 August 2003
Resolved
Strainer box around bilge suction located in forepeak was completely wasted away. Replacement of strainer box is required. LEGACY COMPONENT DESC: Strainer
Engineering › Bilge Water Management System
Issued 6 August 2003
Resolved
Require vessel to prove all bilge pumps and alarms at next inspection. Vessel did not have current plan on how to test system. Next inspection is a quarterly in October 2003. LEGACY COMPONENT DESC: Pump
Construction/Loadline › Penetrations
Issued 6 August 2003
Resolved
Vessel needs to make proper all deck penetrations throughout the vessel, IAW w/ an already outstanding CG-835.
Fire Fighting › Fixed Fire Detection System
Issued 6 August 2003
Resolved
Vessel needs to install a heat detector in chill rool. LEGACY COMPONENT DESC: Heat Detectors
Electrical › Electrical Distribution System (service)
Issued 28 July 2003
Resolved
Install outlets where needed in 2nd & 3rd deck cages to remove power strips. LEGACY COMPONENT DESC: Outlet Box
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 15 April 2003
Resolved
Provide ceiling tile support collars at sprinkler heads where missing. LEGACY COMPONENT DESC: Recreation Space
Accommodation/Occupational Safety › Messroom
Issued 15 April 2003
Resolved
Clean beverage hoses and seperate from electrical wires on 2nd deck bar.
Construction/Loadline › Penetrations
Issued 15 April 2003
Resolved
Seal electrical cable penetrations in bulkheads of hold deck.
Accommodation/Occupational Safety › Heating
Issued 15 April 2003
Resolved
Provide an overflow pipe at bar storage hot water heater. LEGACY COMPONENT DESC: Piping
Fire Fighting › Structural - A Class Divisions
Issued 15 April 2003
Resolved
Provide A60 insulation at emergency escapes hatches in aft breakroom. LEGACY COMPONENT DESC: Decks - Workshops
Documentation › Safety/Response Plans/Programs
Issued 15 April 2003
Resolved
Provide an updated fire control plan for pilot house, main ramp and engine room. LEGACY COMPONENT DESC: Fire Control Plans
Fire Fighting › Automatic Sprinkler System
Issued 15 April 2003
Resolved
Repair leak on sprinkler tank sight glass. LEGACY COMPONENT DESC: Pressure Tank
Communications › Alarms/Indicators
Issued 26 January 2003
Resolved
Provide sign at general alarm bell at 2nd deck cage. LEGACY COMPONENT DESC: General Alarm
Fire Fighting › Structural Fire Protection - General
Issued 26 January 2003
Resolved
Adjust/ repair fire screen door #5 to close, hanging on threshold.
Electrical › Electrical Distribution System (service)
Issued 26 January 2003
Resolved
Provide log of status of the ground fault detector. Record amps at the start of each C. E. watch also note what actions were taken to clear. LEGACY COMPONENT DESC: Ground Detection
Lifesaving › Lifeboat
Issued 23 October 2002
Resolved
Replace stern light lense on stbd life boat.
Electrical
Issued 23 October 2002
Resolved
Repair face plate on electrical outlet main deck fwd cage.
Deck/Cargo › Mooring/Anchoring
Issued 23 October 2002
Resolved
Properly install cable clamps on wire rope mooring lines.
Electrical › Electric Generation Source (emergency)
Issued 23 October 2002
Resolved
Adjust and prove proper operation of fuel stop on emergency generator.
Fire Fighting › Structural Fire Protection - General
Issued 23 October 2002
Resolved
Repair fire stop on wire run entering port lower stair tower.
Documentation › Logs/Records
Issued 23 July 2002
Resolved
Provide a copy of weight change #2- A.
Fire Fighting › Automatic Sprinkler System
Issued 23 July 2002
Resolved
Prove proper operation of sprinkler pump "stop" button on motor controller. LEGACY COMPONENT DESC: Power Sources
Electrical › Electric Supply System (service)
Issued 23 July 2002
Resolved
Repair/ replace 24v DC battery charger, float charge inop. LEGACY COMPONENT DESC: Battery Charger
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 23 July 2002
Resolved
Replace flex hose at "E" genset CO2 bottle. LEGACY COMPONENT DESC: Piping
Fire Fighting › Structural - A Class Divisions
Issued 23 July 2002
Resolved
Properly install deck penetrations (electrical). LEGACY COMPONENT DESC: Decks - Accommodation Spaces
Accommodation/Occupational Safety › Occupational Safety
Issued 16 April 2002
Resolved
Provide signage on hatch and nearby the forward "Emergency" escape scuttle.
Communications › Audible Communications
Issued 16 April 2002
Resolved
Prove proper operation of AEVADS system on both amplifiers.
Documentation › Logs/Records
Issued 16 April 2002
Resolved
Log training topics covered during safety meetings.
Documentation › Manifests/Lists
Issued 16 April 2002
Resolved
Submit muster list for review and approval.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 16 April 2002
Resolved
Clean deck area's of food and trash. Stop water leaks in all bar area's.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 16 April 2002
Resolved
Provide breaker panel insert's at panel's M6 and M4.
Engineering › Compressed Air System (start air)
Issued 16 April 2002
Resolved
Prove proper operation of safety relief valve on #2 air receiver.
Electrical › Electric Supply System (service)
Issued 16 April 2002
Resolved
Properly install and support electrical wires in overhead of ceiling tiles on 2nd deck.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 April 2002
Resolved
Provide and properly install a non-conducting cover on track lighting over high dollar slot's on 2nd deck.
Fire Fighting › Combustible Materials
Issued 16 April 2002
Resolved
Provide metal trash cans in all heads. LEGACY COMPONENT DESC: Furniture/Furnishings
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 16 April 2002
Resolved
Eliminate extension cords in cash cages. Ensure all plugs are properly seated.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 16 April 2002
Resolved
Replace/repair broken 110v outlets in 2nd deck and main deck cage.
Fire Fighting › Automatic Sprinkler System
Issued 16 April 2002
Resolved
Provide copy of fire and sprinkler pump test results.
Fire Fighting › Structural - Horizontal Zones
Issued 16 April 2002
Resolved
Refill fire stop at cable penetrations above bow thruster watertight door.
Electrical › Electric Generation Source (service) › Piping (exhaust)
Issued 16 April 2002
Resolved
Repair exhaust leak on #2 generator at turbo charger outlet flange.
Operations/Management › FireFighting
Issued 10 January 2002
Resolved
Vessel not conducting operational testing as required by 46 CFR 78.
Fire Fighting
Issued 10 October 2001
Resolved
RENEW ALL RECALLED SPRINKLER HEADS IN SPRINKLERS SYSTEM.
Fire Fighting
Issued 25 July 2001
Resolved
Conduct internal exam of both fixed sprinkler system storage tanks._x001C_
Fire Fighting
Issued 25 July 2001
Resolved
Install fire extinguisher in cage on third deck._x001C_
Lifesaving
Issued 25 July 2001
Resolved
Complete all required operational testing and provide documentation of the same. _x001C_
Lifesaving
Issued 25 July 2001
Resolved
Remove volume control switches from the AEVADS system on each deck._x001C_
Electrical
Issued 25 July 2001
Resolved
Renew batteries in emergency lighting on hole deck._x001C_
Accommodation/Occupational Safety
Issued 25 July 2001
Resolved
Properley insulate A/C equipment or provide containment for codensation to keep the deck dry and safe._x001C_
Fire Fighting
Issued 25 July 2001
Resolved
Provide list and repair plan to renew sprinkler heads in the fixed fire system._x001C_
Engineering
Issued 25 July 2001
Resolved
Install proper relief valves on both engine room air receivers._x001C_
Documentation
Issued 24 April 2001
Resolved
PROVIDE PROOF OF MEETING TITLE 33 CFR 130 CERTIFICATE OF FINANCIAL RESPONSIBILITY (COFR) REQUIREMENTS BY OBTAINING A VALID AND CURRENT COFR AND PROVIDE VERIFICATION TO THIS OFFICE VIA THE NATIONAL POLLUTION FUNDS CENTER.
Lifesaving
Issued 12 October 2000
Resolved
Provide required training manuals, maintenance records._x001C_
Fire Fighting
Issued 12 October 2000
Resolved
Post operating instructions at all CO2 remote pull stations._x001C_
Engineering
Issued 12 October 2000
Resolved
Provide proper plug for fuel fill containment._x001C_
Fire Fighting
Issued 12 October 2000
Resolved
Install fire station on fwd exterior deck._x001C_
Construction/Loadline
Issued 12 October 2000
Resolved
Repair escape hatch leaving the bow thruster compartment._x001C_ _x001C_
Engineering
Issued 26 July 2000
Resolved
BAND PADDLE WHEEL BOARDS THAT ARE FRACTURED SPLIT LESS THAN 12 INCHES - REPLACE ALL BOARDS THAT ARE SPLIT GREATER THAN 12 INCHES AND OR HAVE MORE THAN ONE FRACTURE IE..BOTH ENDS.
Unknown
Issued 9 June 2000
Resolved
COMPLETE DEADWEIGHT SURVEY AS A RESULT OF VESSEL'S CUMULATIVE AGGREGATE WEIGHT CHANGE EXCEEDING 2%.
Accommodation/Occupational Safety
Issued 25 April 2000
Resolved
INSTALL PERMANENT NON-COMBUSTIBLE RAMP ON HURRICANE DECK.
Electrical
Issued 25 April 2000
Resolved
HARDWIRE ELEVATOR COOLING PUMP MOTORS.
Fire Fighting
Issued 25 April 2000
Resolved
INSTALL SMOKE DETECTORS IN ALL BARS, CAGES AND OFFICES THAT DO NOT CURRENTLY HAVE THEM.
Electrical
Issued 25 April 2000
Resolved
RELOCATE SEARCHLIGHT FROM STBD BRIDGE WING TO PORT BRIDGE WING UNTIL NEW SEARCHLIGHT ARRIVES.
Fire Fighting
Issued 25 April 2000
Resolved
MAKE REPARIS TO SO-TEC SPRINKLER ALARM PANEL ON BRIDGE.
Fire Fighting
Issued 25 April 2000
Resolved
RE-INSTALL A-60 FIRE PRO INSULATION IN WAY OF COMPUTER ROOM OVERHEAD, EMERGENCY GENERATOR ROOM OVERHEAD, LIQUOR TRUNK AND ANY OTHER AREAS IT IS MISSING.
Lifesaving
Issued 25 April 2000
Resolved
PROVIDE KEYED LOCK FOR SURVEILLANCE W/KEY FOR PILOT HOUSE.
Accommodation/Occupational Safety
Issued 25 April 2000
Resolved
CLEAN SIDE OF COOLER AND STOP LEAK ON LIQUOR DISPENSING LINE 2ND DECK BAR.
Fire Fighting
Issued 26 January 2000
Resolved
PROVIDE APPROVAL DOCUMENTATION FOR SPRINKLER HEADS ON MAIN DECK IN VICINITYOF BAR WHICH WERE MOVED.
Accommodation/Occupational Safety
Issued 26 January 2000
Resolved
INSTALL PROPER COOLING FOR HYDRAULIC OIL STORAGE TANK IN CHILLER ROOM. REMOVE EXTENSION CORD AND PORTABLE FAN.
Electrical
Issued 26 January 2000
Resolved
PROPERLY RUN ELECTRICAL SUPPLY TO HOTWATER TANK IN BEVERAGE STORAGE ROOM.
Fire Fighting
Issued 26 January 2000
Resolved
PROVIDE PROPOSAL TO INCREASE SPRINKLER COVERAGE IN VICINITY OF MAIN DECK BAR AND ALL CAGE AREAS.
Lifesaving
Issued 26 January 2000
Resolved
PROVIDE CONTAINMENT FOR DRAIN CLEANER BARRELS STORED IN BOW THRUSTER SPACE.CONTAINMENT TO BE NON-CORROSIVE MATERIAL.
Lifesaving
Issued 26 January 2000
Resolved
REPAIR GENERAL ALARM BELL IN STATE POLICE OFFICE.
Documentation
Issued 26 January 2000
Resolved
PROVIDE APPROVAL PLANS FOR MINI-CAGE ADDITIONS/MODIFICATIONS ON MAIN DECK AND 3RD DECK STBD AFT AREAS.
Accommodation/Occupational Safety
Issued 26 January 2000
Resolved
REPAIR STARBOARD ELEVATOR TO ORIGINAL OPERATING CONDITION INCLUDING BUT NOTLIMITED TO DOOR LATCHES, SAFETY EQUIPMENT, RUNNING GEAR, DOORS. ELEVATOR TOREMAIN OUT OF SERVICE UNTIL WRITTEN SERVICE REPORT IS SUBMITTED AND APPROVED BY [name withheld] REPORT TO BE MADE BY OTHER THAN CURRENT CONTRA
Lifesaving
Issued 26 January 2000
Resolved
ADJUST EMERGENCY GENERATOR DAY TANK CUTOUT VALVE FOR FUEL TO ENSURE VALVE CLOSES ALL THE WAY.
Documentation
Issued 26 January 2000
Resolved
PROVIDE REVISED FIRE LOAD CALCULATIONS FOR ALL CASINO AREAS.
Fire Fighting
Issued 27 October 1999
Resolved
FIRE DAMPERS 1-1, 1-2, AND 1-7 INOPERATIVE. PROVE PROPER OPERATION OF SAME.
Lifesaving
Issued 27 October 1999
Resolved
REPAIR AND STOP ALL LEAKS IN PORT AND STBD ELEVATORS.
Accommodation/Occupational Safety
Issued 27 October 1999
Resolved
SANITIZE ALL BAR AREAS.
Fire Fighting
Issued 27 October 1999
Resolved
FSD #8 TO BE ADJUSTED TO OBTAIN FULL CLOSURE.
Unknown
Issued 27 October 1999
Resolved
RERUN, USING ESTABLISHED PIPE RUNS AND PROPER MOUNTING HANGERS, THE HOT WATER LINE IN BEVERAGE/LIQUOR STORE ROOM.
Lifesaving
Issued 27 October 1999
Resolved
REPAIR HYDRAULIC LEAKS IN MAIN HOLD AREA (SLOT & HOUSEKEEPING STORAGE).
Documentation
Issued 11 June 1999
Resolved
AS PER MARINE SAFETY CENTER TECHNICAL NOTE 4-95, COMPLETE A DEADWEIGHT SURVEY AND FORWARD RESULTS TO THE USCG MARINE SAFETY CENTER FOR APPROVAL NOLATER THAN 31JUL99.
Electrical
Issued 28 April 1999
Resolved
Properly label UPS service distribution panels in CCTV space.
Lifesaving
Issued 28 April 1999
Resolved
Provide clear passage on main deck in way of engine room emergency escape hatch.
Electrical
Issued 28 April 1999
Resolved
Repair and prove proper operation of starboard set of exhaust blowers in emergency generator space.
Lifesaving
Issued 25 January 1999
Resolved
INSTALL PA SPEAKER IN EOS.
Construction/Loadline
Issued 25 January 1999
Resolved
HARD PIPE DRAINS FROM CHILLER UNIT IN BEVERAGE ROOM AND AIR CONDITIONER IN AFT BREAKROOM.
Electrical
Issued 25 January 1999
Resolved
REMOVE/PERMANENTLY MOUNT JUNCTION BOX HANGING IN WIREWAY OVER #3 WTD IN HOUSEKEEPING STORAGE ROOM.
Accommodation/Occupational Safety
Issued 25 January 1999
Resolved
CLEAN AND SANITIZE RESIDUE FROM DECK IN BEVERAGE ROOM.
Engineering
Issued 25 January 1999
Resolved
REPLACE WASTED PADDLEWHEEL BOARDS.
Lifesaving
Issued 25 January 1999
Resolved
INSTALL SAFETY RELIEF VALVES SET AT NO MORE THAN 110 PSI ON ALL POTABLE WATER PUMPS IN E/R.
Lifesaving
Issued 2 November 1998
Resolved
Secure all loose deck plates in engineering spaces.
Accommodation/Occupational Safety
Issued 2 November 1998
Resolved
Sanitize all beverage/bar areas.
Fire Fighting
Issued 2 November 1998
Resolved
Remove/move signage in way of sprinkler heads installed in accordance with approved sprinkler plan.
Electrical
Issued 2 November 1998
Resolved
Install and prove proper operation of the 24 volt DC distribution panel power supply.
Navigation
Issued 6 August 1998
Resolved
PROVE PROPER OPERATION OF AUDIBLE ALARM FOR STEERING SYSTEM LOSS OF POWER.
Electrical
Issued 6 August 1998
Resolved
LABEL PANEL BOARDS AS PER 46 CFR 111.40-11.
Construction/Loadline
Issued 6 August 1998
Resolved
PROPERLY INSTALL REACH ROD FOR BALLAST PIPING CUT OFF VALVE FOR FOREPEAK.
Electrical
Issued 6 August 1998
Resolved
SUBMIT PROPOSAL TO [name withheld] TO CORRECT 24 VOLT ENGINE ROOM CONTROL PANEL POWER SUPPY.
Navigation
Issued 28 April 1998
Resolved
Prove proper operation of power available lights at steering alarm panel.
Navigation
Issued 28 April 1998
Resolved
Prove proper operation of audible alarm at steering alarm panel.
Fire Fighting
Issued 28 April 1998
Resolved
Install tamper switch on sprinkler tank discharge valve with monitoring at central control panel.
Engineering
Issued 28 April 1998
Resolved
Make permanent repairs to remote fuel shut off on port side of engine room.
Fire Fighting
Issued 28 April 1998
Resolved
Prove proper operation of tamper switches on sprinkler system overboard cutout valve and back up sprinkler pump seachest suction.
Electrical
Issued 28 April 1998
Resolved
Prove proper operation of emergency light at starboard life raft embarkation station.
Lifesaving
Issued 28 April 1998
Resolved
Renew line at life ring on starboard side bow.
Lifesaving
Issued 28 April 1998
Resolved
Repair/replace broken float light at port bridge wing.
Documentation
Issued 28 April 1998
Resolved
Show proof of radar endorsement renewal for master.
Lifesaving
Issued 28 April 1998
Resolved
Provide inspection procedures and logs for lifesaving equipment per 46 CFR 199.190
Documentation
Issued 28 April 1998
Resolved
Provide training/drill logs per 46 CFR 199.180.
Lifesaving
Issued 28 April 1998
Resolved
Mark lifesaving equipment per 46 CFR 199.178.
Lifesaving
Issued 28 April 1998
Resolved
PROVIDE AN APPROVED MUSTER LIST PER 46 CFR 199.80
Engineering
Issued 28 April 1998
Resolved
Prove proper operation of "Z" drive control fault indicators.
Fire Fighting
Issued 28 April 1998
Resolved
Install (3) seperate AEVADS zones for stairtowers and prove proper operation.
Engineering
Issued 28 April 1998
Resolved
Prove proper operation of emergency stop at bridge control station for bow thruster.
Navigation
Issued 28 April 1998
Resolved
Prove proper operation of stern light sensor alarm at navigation light panel.
Lifesaving
Issued 26 January 1998
Resolved
INSTALL THREE (3) SEPERATE AEVADS ZONES FOR STAIR TOWERS (ONE ZONE PER STAIR TOWER) AND PROVE PROPER OPERATION.
Fire Fighting
Issued 6 November 1997
Resolved
MAKE PROPER REPAIRS TO AEVADS MAIN AMPLIFIER. SYSTEM MUST REMAIN ARMED AND ON THE BACKUP AMPLIFIER UNTIL REPAIRS ARE MADE TO MAIN AMP.
Lifesaving
Issued 10 June 1997
Resolved
COORDINATE WITH THE MARINE SAFETY CENTER TO HAVE THE VESSEL'S NEW LIGHTSHIPCHARACTERISTICS EVALUATED DUE TO A 2.12% CHANGE FROM ORIGINAL LIGHTSHIP DISPLACEMENT.
Electrical
Issued 6 May 1997
Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL ALARM/SHUTDOWN AND OVERSPEED TRIP ONEMERGENCY GENERATOR PRIME MOVER.
Electrical
Issued 6 May 1997
Resolved
PROVE PROPER OPERATION OF REVERSE POWER RELAY ON #2 GENERATOR.
Electrical
Issued 27 January 1997
Resolved
PROPERLY DEAD END WIRING IN J-BOX IN OVHD OF MAIN DECK FOR NEW SLOT MACHINEINSTALLATION.
Lifesaving
Issued 27 January 1997
Resolved
PROVIDE "MUSTANG" SUITS (OR EQUIVALENT) FOR RESCUE BOAT CREWS (4 EA).
Engineering
Issued 27 January 1997
Resolved
PROPERLY REPAIR REMOTE FUEL SHUT OFF VALVE PORT SIDE ENGINEROOM.
Fire Fighting
Issued 27 January 1997
Resolved
REPLACE PAINTED SPRINKLER HEAD IN CHILLER ROOM.
Lifesaving
Issued 27 January 1997
Resolved
INSTALL PROPER 12 VOLT MARINE BOW & STERN LIGHTS ON BOTH RESCUE BOATS.
Construction/Loadline
Issued 7 August 1996
Resolved
PROVE PROPER OPERATION OF CLASS III WTD'S IN HOLD DECK WHEN LOSS OF POWER OCCURS.
Fire Fighting
Issued 6 May 1996
Resolved
REPLACE STRUCTURAL FIRE PROTECTION TO ORIGINAL ON OVERHEAD PENETRATION & ATTACHMENTS (SEE NVIC 6-80) IN CREWS LOUNGE HOLD DECK.
Fire Fighting
Issued 6 May 1996
Resolved
INSULATE OVERHEAD ATTACHMENTS IN CREWS LOUNGE (12" BACK, INSULATION ABUTTEDPER NVIC 6-80 THAT HAVEN'T ALREADY BEEN (i.e. WIRE, SPRINKLER PIPE HANGERS,PIPE AND WIRE PENETRATIONS).
Electrical
Issued 6 May 1996
Resolved
MAKE PROPER REPAIRS TO ELIMINATE AN ELECTRICAL GROUND INDICATION AT THE MAIN SWITCHBOARD.
Lifesaving
Issued 6 May 1996
Resolved
REMOVE ALL UNNECESSARY EQUIPMENT AND SECURE ALL LOOSE GEAR IN SLOT REPAIR ROOM.
Unknown
Issued 6 May 1996
Resolved
REPAIR OR REPLACE AND TEST OPERATE THE PRESSURE RELIEF VALVE TO #2 AIR- RECEIVER IN ENGINEROOM
Accommodation/Occupational Safety
Issued 6 May 1996
Resolved
REPLACE/REPAIR INOPERATIVE LED READOUT IN STBD ELEVATOR (INDICATE WHAT FLOOR PASSENGERS ARE ON).
Fire Fighting
Issued 30 January 1996
Resolved
Provide a relief valve on the sprinkler air head tank.
Fire Fighting
Issued 30 January 1996
Resolved
Install 1 1/4 inch buttons on A-60 insulation holding pins in storage spaceon 4th deck aft of pilot house.
Electrical
Issued 30 January 1996
Resolved
Repair 5-10 AMP ground fault on 480 volt ship's service generator.
Fire Fighting
Issued 30 January 1996
Resolved
Provide proper clearances for fire screen doors in hold deck. (Max 1/2 inch)
Electrical
Issued 30 January 1996
Resolved
Prove proper operation of reverse power relay on No. 2 generator.
Documentation
Issued 9 November 1995
Resolved
COMPLETE CHEMICAL TESTING PROGRAM AUDIT (FORM "B") AND RETURN TO ATTENDING MARINE INSPECTOR, OR PROVE SUBMISSION OF M.I.S. FORM FOR CALENDER YEAR 1994.
Accommodation/Occupational Safety
Issued 9 November 1995
Resolved
MAKE PROPER REPAIRS TO #1 CHILLER UNIT.
Engineering
Issued 10 August 1995
Resolved
PROVE PROPER OPERATION OF THE #4 AUXILIARY GENERATOR ENGINE. ENGINE WILL NOT START.
Navigation
Issued 23 May 1995
Resolved
INSTALL TAGS ON GRAULER PHONE WITH PROPER IDENTIFICATION NUMBERS LOCATED INTHE P/S Z-DRIVE COMPARTMENTS.
Fire Fighting
Issued 23 May 1995
Resolved
REPAIR A-60 INSULATION IN HOUSEKEEPING COMPARTMENT ON PORT SIDE FORWARD, PORT SIDE AFT, AND STBD SIDE AFT.
Construction/Loadline
Issued 23 May 1995
Resolved
MAKE BILGE & BALLAST PIPING/PUMPING SYSTEM COMPLY WITH 46 CFR 56.50-50(l).
Fire Fighting
Issued 23 May 1995
Resolved
PROVIDE AND MOUNT SPARE SPRINKLER CABINET WITH COMPLETE STOCK OF SPARE SPRINKLER HEADS AND WRENCH IAW NFPA 13 2-2.7.1 THRU 2-2.7.3
Fire Fighting
Issued 23 May 1995
Resolved
PROVIDE LOG FOR INSPECTION, TESTING & MAINTENANCE OF SPRINKLER SYSTEM.
Documentation
Issued 29 March 1995
Resolved
REVISE VESSEL'S APPROVED PLANS (IE. PIPING, ELECTRICAL, FIRE CONTROL, ETC.)TO REFLECT MODIFICATIONS TO SPRINKLER SYSTEM AND FIRE DETECTION SYSTEM (PULL STATIONS, SMOKE DETECTORS).
Electrical
Issued 29 March 1995
Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL SWITCH/SHUTDOWN ON #2 S/S GEN.
Fire Fighting
Issued 29 March 1995
Resolved
REVISE VESSEL'S SPRINKLER MANUAL TO REFLECT MODIFICATIONS TO SPRINKLER SYSTEM.
Electrical
Issued 22 February 1995
Resolved
PROVIDE A MEANS OF DETERMINING ENGINE RPM ON THE EMERGENCY GENERATOR TO TEST OPERATION OF ENGINE OVERSPEED.
Electrical
Issued 22 February 1995
Resolved
PROVIDE BATTERY POWERED EMERGENCY LIGHTING FOR ENGINEROOM SWITCHBOARDS, EMERGENCY SWITCHBOARDS, ESCAPE SCUTTLES/WTD'S IN ENGINEERING SPACES AND HOLD DECK.
Electrical
Issued 22 February 1995
Resolved
PROVIDE WRITTEN/POSTED PROCEDURES TO SECURE SHORE POWER TO MAIN SWITCHBOARDFROM THE SOURCE ASHORE IN THE EVENT OF AN ELECTRICAL CASUALTY TO MAIN SWITCHBOARD. POST PROCEDURES ON MAIN SWITCHBOARD AND MAINTENANCE CONTROL STATION.
Fire Fighting
Issued 22 February 1995
Resolved
PROVE SPRINKLER SYSTEM IS DESIGNED/INSTALLED IAW NVIC 10-93; SPECIFICALLY PARAGRAPH 4-6.1. ALARM SIGNALS FOR MONITORING POSITION OF ALL CONTROL VALVES, FIRE PUMP POWER SUPPLIES & OPERATING CONDITION TO ALARM IN THE CENTRAL SAFETY STATION & AUTO START-UP OF MAIN & BACK-UP SPRINKLER PUMPS.
Fire Fighting
Issued 22 February 1995
Resolved
PROVIDE A SOURCE OF POWER TO THE FORWARD FIRE PUMP, SUCH AS TO ENSURE THAT A FIRE IN THE ENGINEROOM WILL NOT PUT BOTH FIRE PUMPS OUT OF OPERATION.
Construction/Loadline
Issued 22 February 1995
Resolved
CHANGE ALARM INDICATORS ON CLASS I WTD'S #2,5, & 6 TO MONITOR DOG, PROVING DOORS ARE CLOSED AND FULLY DOGGED.
Lifesaving
Issued 22 February 1995
Resolved
INSTALL & PROVE PROPER OPERATION OF POWER OPERATED WINCHES FOR BOTH RESCUE BOATS.
Engineering
Issued 22 February 1995
Resolved
PROVE OPERATION OF ALL FIVE (5) DIESEL ENGINE/GEN SET LOW OIL PRESSURE SWITCHES TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Accommodation/Occupational Safety
Issued 23 August 1994
Resolved
Permenantly repair all cracked handrails on 04 deck. Ensure adequate measures are taken to ensure passenger safety.
Engineering
Issued 23 August 1994
Resolved
Repair leakingfitting and cracked weld on the emergency gen. F/O service tank permenantly,
Engineering
Issued 23 August 1994
Resolved
Permenantly repair expansion tank for colling water on #4 Gen. where fractured and leaking.
Engineering
Issued 23 August 1994
Resolved
Permenantly repair F/O leaks for #4 gen. where leaking at piping elbows.
Electrical
Issued 23 August 1994
Resolved
Permenantly repair or modify the Beer/Ice machine Circ. pump breaker in theengine room to eliminate cause of repeated high temp readings and tripping.
Documentation
Issued 23 August 1994
Resolved
Provide a copy of fuel oil transfer procedures for vessel's fuel oil transfer system, including DOI. See 33 CFR 155.720.
Electrical
Issued 23 August 1994
Resolved
Properly terminate all loose wire ends in Pyrotronics panel.
Documentation
Issued 23 August 1994
Resolved
Consolidate information found in vessels elevator instaallation manuals into one manual to provide specific guidance on the operation, testing, reset, maintenance of the vessel's elevators for ships crew.
Fire Fighting
Issued 23 August 1994
Resolved
Lable all vents on main deck.
Documentation
Issued 23 August 1994
Resolved
Modify sprinkler system manual required by 46CFR 76.25-35 (j) include vessel piping diagram with valves, pumps, controls, etc. and directions for all required /Emergency modes of operation.
Construction/Loadline
Issued 23 August 1994
Resolved
Permenantly repair 1" penetration in emergency generator blkhd.
Accommodation/Occupational Safety
Issued 2 June 1994
Resolved
REPLACE MISSING DOOR KNOBS ON THE FOLLOWING FIRESCREEN DOORS, HURRICANE DECK STBD SIDE, PORT SIDE FWD DOOR, DOOR TO E/R SDTB SIDE MIDSHIP. DUE TO MISSING AND MALFUNCTIONING DOOR KNOBS.
Accommodation/Occupational Safety
Issued 2 June 1994
Resolved
REPAIR/RENEW BROKEN HANDRAILS PORT AND STBD SIDE FWD LADDER LEADING TO 3RD DECK. CURRENT TEMP REPAIRS UNSAFE TO PASSENGERS.(ROUND STOCK TAPED TO THE UNDERSIDE OF THE BROKEN RAILS)
Accommodation/Occupational Safety
Issued 2 June 1994
Resolved
FIRE SCRREN DOOR 2ND DK CENTERLINE AT BOW COVERED BY RUG DUE TO DOOR SILL DAMAGE, MAKE PROPER AND PERMENANT REPAIRS TO ORIGINAL SILL AND ADJUST /REPAIR FIRE DOORS.
Accommodation/Occupational Safety
Issued 2 June 1994
Resolved
PROVIDE SERVICING REPORT /CERTIFICATION FOR SHIPS ELEVATORS, PROVIDE PROOF OF APPROPRIATE CREW TRAINING IN THE OPERATION AND CONTROLS OF THE ELEVATORS.
Fire Fighting
Issued 2 June 1994
Resolved
OBTAIN/PROVIDE COPY OF SPRINKLER SYSTEM OPERATING TESTING AND MANITENANCE MANUAL. PROVIDE PROFF OF APPROPRIATE CREW TRAINING IN THIS REGARD. 46CFR 76.35(J).
Fire Fighting
Issued 2 June 1994
Resolved
PROVIDE SERVICING REPORT ON PYROTECHNIC FIRE DETECTION CABINET (SYSTEM TESTED AND FOUND SAT, BY CG MARINE INSPECTORS 02JUN94)
Deck/Cargo
Issued 20 May 1994
Resolved
PROVIDE CALCULATIONS TO COGIZANT [name withheld] OF THE ANCHOR SIZE WITH ABS INLAND PASSENGER.
Accommodation/Occupational Safety
Issued 20 May 1994
Resolved
INSTALL PHONES BOXESIN PORT AND STBD ELEVATOR.
Fire Fighting
Issued 20 May 1994
Resolved
PROVIDE UPDATED COPY OF THE FIRE CONTROL PLAN TO COGNIZANT OCMI FOR APPROVAL.
Accommodation/Occupational Safety
Issued 20 May 1994
Resolved
PERMANENTLY INSTALL STEEL RETAINING CLIPS ON ALL EXTERIOR WINDOWS (TAP AND BOLT).
Fire Fighting
Issued 20 May 1994
Resolved
ENCLOSE PILOT HOUSE WELL TO PROVIDE A-O BOUNDRY OR SUBMIT PROPOSAL TO THE MARINE SAFETY CENTER TO REDISIGNATE COMPARTMENT WITHOUT HYDRAULIC PUMP AND ASSOCIATED EQUIPMENT.
Accommodation/Occupational Safety
Issued 20 May 1994
Resolved
INSTALL PERMENANT EXIT SIGNS IN VICINITY OF THE FWD DOOR TO ALL (PORT AND STBD ALL DECKS) AFT STAIR TOWERS.
Fire Fighting
Issued 20 May 1994
Resolved
SUBMIT CONSOLIDATED EEP WITH ADDENDUM ATTACHED. REMOVE REFERENCE TO THE BOILER DECK FROM THE ADDENDUM.
Casualty record · 1
14 October 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3616140
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.