MAURY USCG vessel records
← All vessels

SALTY GOAT

SALTY GOAT is a 1994 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in July 2026, along with 58 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 22 July 2026.

Built
1994
Last inspected
22 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 July 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC9302
402907
Flag
UNITED STATES
Maury page id
psix-402907

Documentation record

Registered dimensions (L × B × D)46.0 ft × 14.0 ft × 6.0 ft
Registered tonnagegross 25 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARKLEY'S MARINA INC · BALTIMORE, MD, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 11 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Simplified, Gross Ton
20 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

22 July 2026 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8438564
21 July 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8191211
17 April 2025 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8113124
11 October 2024 Examination of Repairs · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8026641
11 June 2024 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7941872
22 August 2023 Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7774195
1 August 2023 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7756819
24 April 2023 Internal Structural Exam · Drydock Exam · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7672229
3 May 2022 COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7438377
9 August 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7281547
23 April 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7161318
17 June 2020 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6977239
9 April 2020 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6938238
3 May 2019 Administrative Inspection · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6675546
4 April 2018 Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6384990
29 March 2017 Internal Structural Exam · Administrative Inspection · Hull Examination · COI Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6131861
1 February 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6081153
1 April 2016 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5845367

Deficiency record · 58

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 July 2026 Resolved
The Cat 1 EPIRB must be in a float free arrangement. Provide and mark a new hydrostatic release prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 July 2026 Resolved
The vessel must have a total of 6 hand red flare and 6 orange smoke (or 12 hand red flare) distress signals on board. Provide 3 red and 6 orange (or 9 red) additional distress signals prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 July 2026 Resolved
Provide 7 additional Type I adult life jackets prior to carrying more than 26 passengers and 28 total people.
Action required: 705 - Other - as specified
Due 5 August 2026
Resolved 6 August 2026
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 July 2026 Resolved
Conduct and log an abandon ship, man overboard, and fire fighting drill for each crewmember at least once every three months.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2026
Resolved 6 August 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 July 2026 Resolved
Provide and mark 1 additional "Fire Bucket" of at least 2.5 gallons and attach a lanyard long enough to reach the water.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2026
Resolved 6 August 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 July 2026 Resolved
Provide a visual indicator to show when the forward automatic bilge pump is operating.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2026
Resolved 6 August 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 July 2026 Resolved
There is an open electrical outlet in the pilot house. Completely enclose or remove the electrical outlet and exposed wires (outlet and wiring was powered from the former generator).
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2026
Resolved 6 August 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 July 2025 Resolved
Replace the 5-B:C portable fire extinguisher located in the pilot house with a 10-B:C portable fire extinguisher.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2025
Resolved 7 August 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 July 2025 Resolved
Provide a valid FCC Safety Radio Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2025
Resolved 7 August 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 October 2024 Resolved
Propulsion machinery mast be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel owner reported a grinding noise coming from the transmission preventing the vessel from safely getting underway. Diagnose and address issue prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2024
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 August 2023 Resolved
The hydrostatic release for the Cat 1 EPIRB is expired and the vessel is not equipped with survival craft.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 August 2023 Resolved
Install a plug in the valve for removing water from the Raycor filter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 August 2023 Resolved
Remove the dead end wiring in the life jacket stowage locker or cap and properly secure in an enclosure.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2023 Resolved
Vessel rep reported an issue with the engine's ignition switch preventing the engine from starting as designed. Diagnose issue and provide repair plan. Start and run the engine and perform pre-engineered fixed fire extinguisher automatic shutdown and override restart.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2023
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 May 2022 Resolved
Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit. Operator does not have Marine Radio Operator Permit. Vessel is restriced to 1000 feet from shore until provided.
Action required: 705 - Other - as specified
Due 3 May 2022
Resolved 11 September 2023
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 May 2022 Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel. Vessel did not have records of EAP training available.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2022
Resolved 14 May 2022
Resolution: Documentation provided.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 May 2022 Resolved
Supervisory personnel must receive at least 60 minutes of EAP traning. Master had not completed training.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2022
Resolved 14 May 2022
Resolution: Documentation provided.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 3 May 2022 Resolved
Provide fire extinguishing service record.
Action required: 10 - Deficiency Rectified
Due 3 May 2022
Resolved 3 May 2022
Resolution: Documentation provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 May 2022 Resolved
Repair emergency steering device.
Action required: 10 - Deficiency Rectified
Due 3 May 2022
Resolved 3 May 2022
Resolution: Repaired on the spot
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 August 2021 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is overdue for annual inspection. Anniversary date is 09MAY.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2021
Resolved 16 August 2021
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 23 April 2021 Resolved
Seal the holes in the engine room's forward bulkhead to make the bulkhead vapor tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 April 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 April 2021 Resolved
There is flexible hose between the hull fittings and shutoff valves for the forward and aft submersible electronic bilge pumps. Install the shutoff valve directly at the hull penetration.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 April 2021
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 17 June 2020 Resolved
Vesel crew must provide verification of first aid training.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2020
Resolved 18 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 June 2020 Resolved
Vessel must provide required amount of distress flares for a limited coastwise route (6 red and 6 orange, red may be substituted for orange).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2020
Resolved 18 September 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 June 2020 Resolved
Vessel failed to conduct an annual inspection in 2019 during the alloted timeframe. Vessel prohibited from operating until successful inspection conducted.
Action required: 10 - Deficiency Rectified
Due 17 June 2020
Resolved 17 June 2020
Resolution: Successful annual inspection conducted. Letter of Warning pursued as enforcement action and accepted by operator. See attached witness statement from operator attesting to operations outside of the inspections window.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 May 2019 Resolved
Replace cutlass bearing, aft of bearing delaminated and wore past 50%.
Action required: 705 - Other - as specified
Resolved 10 May 2019
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 3 May 2019 Resolved
Repair/replace aft wooden deck frames #1 and #3, frames are rotten. If repair is requested submit plan prior to conducting repairs to local Coast Guard unit.
Action required: 705 - Other - as specified
Resolved 7 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 3 May 2019 Resolved
Provide metallic positive shutoff valves at hull penetration for all installed submersible bilge pumps. Access shall be provided to operate valve when needed.
Action required: 705 - Other - as specified
Resolved 10 May 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2019 Resolved
Installed bow thruster shall be restricted from use by shutting off both power supply switches, removal of battery terminal connections and protecting terminals from contact to prevent arcing.
Action required: 705 - Other - as specified
Due 10 May 2019
Resolved 10 May 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 May 2019 Resolved
Submit electrical drawings to the Coast Guard Marine Safety Center at [email withheld] (note vessel name and Official Number) include Manufacture specifications of bow thruster assembly, battery bank, switches, over current protection, battery charger, wire run length, wire size, wire type and connection to house panel if applicable. Following MSC approval local Coast Guard will re-attend Vessel to certify proper installation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 April 2021
Resolution: bow thruster has be secured
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 3 May 2019 Resolved
Secure metal cover forward of collision bulkhead on upper deck just aft of bow. Compartment shall be able to be made weathertight.
Action required: 705 - Other - as specified
Resolved 10 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 3 May 2019 Resolved
Provide securing devices of suitable strength for all deck hatches so that hatches are not lost or become sliding hazards.
Action required: 705 - Other - as specified
Resolved 10 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 May 2019 Resolved
Make exhaust system ready for re-inspection upon completion of replacing flexible tubing.
Action required: 705 - Other - as specified
Resolved 10 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 May 2019 Resolved
Make engine ready for re-inspection upon completion of replacing flexible tubing.
Action required: 705 - Other - as specified
Resolved 10 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 3 May 2019 Resolved
Demonstrate proper operation of all thru-hull valves below waterline, valves are being replaced.
Action required: 705 - Other - as specified
Resolved 10 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 3 May 2019 Resolved
Install suitable hull strainer for engine cooling intake. No strainer had been previously installed.
Action required: 705 - Other - as specified
Resolved 10 May 2019
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 3 May 2019 Resolved
Temporary fiberglass repairs on weather deck shall be removed and repairs shall be made as per NVIC 8-87 as provided.
Action required: 705 - Other - as specified
Resolved 10 May 2019
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 3 May 2019 Resolved
Remove delaminated fiber glass on areas of keel identified by Marine Inspector, properly carry out replacement in kind (biaxial fibers) as per NVIC 8-87. Make Available for re-inspection prior to painting or sanding down.
Action required: 705 - Other - as specified
Resolved 7 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 May 2019 Resolved
Install emergency fuel shut off valves at tanks (two).
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2019
Resolved 10 May 2019
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 April 2018 Resolved
Provide valid Certification of Documentation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2018
Resolution: Vessel located orginal COD.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 4 April 2018 Resolved
Provide proof of enrollment for all crew members fro Drug Testing Program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2018
Resolved 7 June 2018
Resolution: Proof of enrollment for all crewmembers onboard.
Lifesaving › Lifefloat › Serviceable
Issued 4 April 2018 Resolved
Repair/Replace Lifefloat, (SOLAS tape, Vessel name, passenger count, orange paint, 100' painter line).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2018
Resolved 7 June 2018
Resolution: Life Float repainted, re labeled, new SOLAS tape applied and new 100' painter replaced.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 4 April 2018 Resolved
Provide Waste Managment Plan
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2018
Resolved 7 June 2018
Resolution: Plan on board.
Accommodation/Occupational Safety › Ventilation › General
Issued 4 April 2018 Resolved
Provide vent closure devices for engine room Port/STBD deck vents.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2018
Resolved 7 June 2018
Resolution: Vent closure devices installed and functional.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 9 May 2017 Resolved
Conduct man overboard drill while underway.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2017
Resolution: Vessel got underway and conducted satisfactory MOB drill.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 9 May 2017 Resolved
Conduct operational test of fireboy system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2017
Resolution: Conducted satisfactory test of fireboy system.
Lifesaving › Lifebuoys › Serviceable
Issued 9 May 2017 Resolved
Replace/Renew life ring buoy.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 15 May 2017
Documentation › Markings/Placards › Lifejacket Placard
Issued 9 May 2017 Resolved
Provide donning instructions for each type of life jackets onboard.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 15 May 2017
Resolution: Placard installed.
Communications › Radio Communications › EPIRB
Issued 9 May 2017 Resolved
Mount EPIRB in a float free location.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2017
Resolution: EPIRB mounted above wheelhouse.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 9 May 2017 Resolved
Replace 02 PFD's.
Action required: 705 - Other - as specified
Resolved 15 May 2017
Resolution: 02 new PFD's added to vessel.
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 May 2017 Resolved
Provide audible indication for engine space bilge high level alarm.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 15 May 2017
Resolution: Observed audible indication for engine space.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 9 May 2017 Resolved
Provide documentation of servicing history for fireboy system.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 15 May 2017
Resolution: Documentation provided of servicing from prior year.
Lifesaving › Hand Flares › Expired
Issued 9 May 2017 Resolved
Provide 04 additional hand flares.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 15 May 2017
Resolution: 04 new flares provided.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 9 May 2017 Resolved
Provide valid masters license for vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2017
Resolution: Master provided with valid MMD.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 February 2017 Resolved
Vessel must complete a credit dry dock prior to operating with passengers. Vessel will be taken out of service.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2017
Resolution: deactivated COI
Engineering › Bilge Water Management System › Pump
Issued 4 April 2016 Resolved
Bilge pump needs to be installed in engine space.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2016
Resolved 22 April 2016
Resolution: Tested bilge pump in ER.
Lifesaving › Lifefloat › Float-free Link
Issued 4 April 2016 Resolved
Weak link on Life float was improperly installed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2016
Resolved 22 April 2016
Resolution: Verfied proper weaklink installation.
Communications › Radio Communications › EPIRB
Issued 4 April 2016 Resolved
EPIRB Hydrostatic Release was expired. Vessel needs to replace hydrostatic release or provide proof of installation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 22 April 2016
Resolution: Hydrostatic release replaced w/approved type.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.