MAURY USCG vessel records Sign in
← All vessels

PHILIP

PHILIP is a 1998 freight ship. The Coast Guard has recorded 41 inspections since 2004, most recently in September 2011, along with 38 deficiencies and 17 operational controls.

Records from 2004 to 2011. Most recent: inspection, 21 September 2011.

Built
1998
Last inspected
21 September 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9126716 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-40294

Inspections, by type

…with no type recorded21
Years with a record 8 calendar years (2004–2011)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it2005 - Convention (Subpart B), Net Ton
4150 - Convention (Subpart B), Gross Ton
5031 - Dead Weight, Ton
7520 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 41

21 September 2011 Ballast Water Examination · Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4150604
20 September 2011 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4144849
1 February 2010 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3673732
30 January 2010 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3672681
28 January 2010 NPV Safety Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3671084
25 January 2010 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3669852
25 January 2010 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3671677
2 January 2010 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3655577
20 July 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3535990
15 March 2009 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3433685
14 March 2009 ISPS I Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3430685
21 February 2009 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3421627
6 February 2009 COE-Dockside · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3413346
25 August 2008 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3308542
6 August 2008 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3290472
24 July 2008 MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3277428
11 June 2008 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3232773
13 May 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3205595
28 December 2007 PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3121667
12 December 2007 MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3114542
28 November 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3106444
21 November 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3102196
13 November 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3097723
13 November 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3097917
13 November 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3109274
14 October 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3079772
4 October 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3073066
25 September 2007 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3065958
22 September 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3063422
17 July 2007 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2998220
9 April 2007 Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2904446
6 April 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2903320
20 May 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2653866
3 May 2006 ILO-147 Exam · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2639721
18 March 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2604719
22 February 2006 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2590015
22 January 2006 ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2570834
25 November 2005 ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2540493
24 July 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2437652
18 November 2004 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2243495
18 November 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2243690

Deficiency record · 38

Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 21 September 2011 Resolved
To enable pipes of reception facilities to be connected w/ the ship's discharge pipeline for residues from machinery bilges and from sludge, both lines shall be fitted w/ a staandard discharge connection. Vsl has 3 bolts instead of 6 on stbd side pipe. Port side pipe is rusted.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 September 2011
Resolution: Proper repairs made to standard discharge connections IAW class report.
Engineering › Steering Gear System › Rudder Stock
Issued 21 September 2011 Resolved
All steering gear componetns and rudder stock shall be of sound and reliable construction to the satisfaction of the administration. Steering gear has no containment for leaks, and when the pump is running, a seawater leak flows through the rudderstock.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2011
Resolution: Repacked stuffing box of rudderstock, no leaking present. Two damns installed which closed off containment according to class report.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 21 September 2011 Resolved
One of the two means of escape from each machinery space shall be within a protected enclousure with self closing fire doors of the same fire integrity and hsall have emergency lighting provisions. Escape trunk access from the engine room and main control room are not self closing and two of the emergency lamps are inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2011
Resolution: Self closing mechanisms installed according to class survey.
Documentation › Logs/Records › Oil Record Book
Issued 28 January 2010 Resolved
A new ORB Part one is onboard but the vsl does not have a complete version of previous ORB readily available for inspection. CG inspectors were provided with a photo copied version dated June09. ORB should be kept onboard for three years. Vsl detained. To the satisfaction of Flag Administration. MARPOL 2006 consolidated Annex I/17.6
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2010
Resolution: Past three years of ORB obtained from previous vessel Manager''''s and provided onboard.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 January 2010 Resolved
It was reported by crew that the OWS was repaired but not tested after repairs. MARPOL 2006 Annex I/14.6
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2010
Resolved 29 January 2010
Resolution: Full function tests were carried out satisfactorily in the presence of CG inspectors and attending class surveyor.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 January 2010 Resolved
While conducted operational tests of emergency lighting, it was discovered that several lights were inoperable. Lights at muster stations and embarkation stations were among those that did not illuminate. Vsl detained-SOLAS 2004 II-1/43.2.1 To satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2010
Resolution: Emergency lights repaired, tested and found satisfactorily.
Electrical › Electric Generation Source (emergency) › Generator
Issued 28 January 2010 Resolved
Emergency generator starts but does not longer than 10 seconds. Several attempts were made with same results. In case of fire, emergency generator would not operate properly. Additionally, there is no evidence in the official log book that the required weekly tests were carried out. Vsl detained-SOLAS 2004 II-1/43.3.1.2 To the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2010
Resolution: Emergency generator repaired and tested including secondary means of starting and found satisfactory.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 28 January 2010 Resolved
There are no entries in the SOLAS training manual that indicates crew is familiar with the use of ships lifesaving appliances, survival craft equipment and firefighting appliances. All crew has been onboard longer than two weeks. SOLAS 2004 III/19.2.1. To the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2010
Resolution: Crew has now reviewed manuals and familiar with contents. Now noted in compliance.
Navigation › Voyage Data Recorder › Simplified Voyage Data Recorder (SVDR)
Issued 28 January 2010 Resolved
The vessel's Voyage Data Recorder is inoperable. As per Safety Equipment Certificate, the VDR must be operational by first scheduled dryckock after 01JUL07, but no later than 01JUL10. SOLAS 2004 V/20. To the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2010
Resolution: Repaired by specialist technician and confirmed now satisfactory.
Fire Fighting › International Shore Connection › Bolts
Issued 28 January 2010 Resolved
International shore connection is missing 04 bolts and a gasket. In the event of a fire, shore side personnel could not assist. SOLAS 74 II-2/5 (h). To the satisfaction of class.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2010
Resolution: Missing bolts and gasket now provided and satisfactory.
Construction/Loadline › Structures › Door
Issued 28 January 2010 Resolved
Door leading from steering gear space to open deck has loose dogs (closing) devices. The weathertight integrity of space is compromised. ICLL 1966 Annex I/12.1. To the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2010
Resolution: Loose dogs repaired, door tested for weathertightness and security and found satisfactory.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 28 January 2010 Resolved
Following equipment was identified as unsatisfactory: port quarter ring buoy light inoperable, port amidship ring buoy missing and bracket broken, reflective tape on one immersion suit falling off, port quarter ring buoy (rescue boat) missing, 04 parachute flares in lifeboat expired, SART not located in freefall lifeboat. SOLAS 2004 III/20.2. To satisfaction of class.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2010
Resolution: All items found rectified/repaired/renewed as required and satisfactory.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 28 January 2010 Resolved
Lifesaving equipment in forward deck store is blocked by ships stores and is not readily accessible. SOLAS 74 III/22 (e). To satisfaction of CG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2010
Resolution: Ships store removed and equipment now accessible.
Fire Fighting › Means of Escape › Blocked
Issued 28 January 2010 Resolved
Means of escape from engine control room is blocked by ships stores and does not allow a ready means of escape to embarkation deck. SOLAS 2004 II-2/13.1.2. To the satisfaction of CG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2010
Resolution: Ships stores removed and means of escape is accessible.
Fire Fighting › Fire Hoses › Condition
Issued 28 January 2010 Resolved
While testing fire hoses on cargo deck, six hoses had significant leaks and one hose completely separated. The vessel does not have sufficient number of hoses that are available and accessible at all times. Vsl detained. SOLAS 2004 II-2/10.2.3.1.1. To the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2010
Resolution: Fire hoses times 10 pc noted renewed and found satisfactory with proper bindings employed.
Fire Fighting › Fire Main › Condition
Issued 28 January 2010 Resolved
During an operational test of the fire main, a leak of at least one gallon per minute was discovered. The leak is located just aft deck of cargo hatch #3. SOLAS 2004 II-2/10.2. To the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2010
Resolution: Permanently repaired, tested and found satisfactory.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 28 January 2010 Resolved
Objective evidence discovered during an expanded examination of the safety management system onboard indicates a serious lack of effective implementation. Request external audit of SMS. Detained- SOLAS 2004 IX/3 and 5. To the satisfaction of Recognized Organization.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2010
Resolution: Bureau Veritas conducted and completed external ISM audit on 01JUN10. Two minor non-conformities identified to be dealt with at next scheduled audit.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 25 July 2008 Resolved
PSCO's noted multiple fire screen doors which did not operate properly: 1) Doors in vicinity galley & engine room with holdbacks & not closing securely. 2) Doors in stairwell not closing securely. Class to attest to proper operation of all fire screen doors. Solas 74 (amend.) II-2/46 & 47 To the satisfaction of class
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 August 2008
Resolved 25 August 2008
Resolution: Received Class report stating action had been taken to correct defs
Operations/Management › Ballast Water Managment › Submission of Report
Issued 24 July 2008 Resolved
Vessel Ballast Water Management Plan does not reflect current reporting requirements for the United States. 33 CFR151.2041 To the satisfaction of the Coast Guard
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 August 2008
Navigation › Piloting/Steering › Gyro Compass
Issued 13 May 2008 Resolved
Vsl has an inop gyro compass.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2008
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 12 December 2007 Resolved
Vessels #4 and #5 fuel oil pumps on the Main Engine are leaking fuel oil creating a fire hazard due to heated surfaces directly below. Vessel must repair fuel oil leaks to prevent any furl oil from coming in contact with heated surfaces.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2007
Resolution: Heated surfaces freed of flammable materials and leaks have been repaired
Electrical › Electric Generation Source (service) › Generator
Issued 12 December 2007 Resolved
Vessels #2 and #3 Service Generators are leaking fuel oil onto heated surfaces directly below creating a hazard. Vessel must repair fuel oil leaks to prevent any fuel oil from coming in contact with heated surfaces.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2007
Resolution: Leakes are repaired and heated surfaces freed of flammable material
Navigation › Piloting/Steering › Magnetic Compass
Issued 12 December 2007 Resolved
Vessels Magnetic Compass was not illuminated and required removing the cover allowing natural light to enter in order to be visible.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2007
Resolution: Vessel''s compass light working properly.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 12 December 2007 Resolved
Vessel could not provide adequate pressure from the emergency fire pump.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2007
Resolution: Vessel''s emergency fire pump working fine.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 12 December 2007 Resolved
Vessel could not provide a Coast Guard Light List or Inland Nav Rules.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2007
Resolution: Vessel able to locate CG Light List and Nav Rules.
Electrical › Electric Generation Source (service) › Generator
Issued 12 December 2007 Resolved
Vessels impulse sensor on #1 Ships service Generator is inoperable. Vessel must make proper repairs to impulse sensor. Condition creates hazardous engine speed condition.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2007
Resolution: Impulse sensor renewed and in proper working condition
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 13 November 2007 Resolved
Received notification a loss of propulsion. Vessel required to submit documentation from the certificate issuing authority attesting to the nature of the problem, corrective action taken, and the ability of the vessel to safely transit through the Port of Houston.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2007
Resolution: Received Class report attesting to the nature of problem and proper repairs made.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 14 October 2007 Resolved
Vessel missing starboard anchor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2007
Resolution: Received satisfactory class report.
Navigation › Collision/Grounding Avoidance › Radar
Issued 22 September 2007 Resolved
Primary marine radar is inoperable.
Action required: 705 - Other - as specified
Resolved 22 September 2007
Resolution: Received tech report attesting to the repair and a satisfactory op test of the radar.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 9 April 2007 Resolved
vessel has two proximity suits, required to have fire fighting suits in compliance with FSS code.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2007
Resolution: CLEARED PER INSPECTOR''S REPORT AND CLASS REPORT.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 9 April 2007 Resolved
alarm on bridge had very low decibles for audible alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2007
Resolved 17 July 2007
Resolution: CLEARED PER INSPECTOR''S REPORT AND CLASS REPORT.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 February 2006 Resolved
Automatic/retractable doors leading to engine room and AC room were not closing properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2006
Resolved 22 February 2006
Resolution: 3 doors in question were observed to be working satisfactorily by a CG Inspector.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 January 2006 Resolved
Auto-doors to the Engine room (034a & 034), Steering Gear room, and A/C room (024) did not self-close.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 February 2006
Resolved 22 February 2006
Resolution: Cleared during def check conducted on 22 feb 06
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 19 November 2004 Resolved
Properly seal fire stop (insulation) in steering room overhead.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2004
Resolved 19 November 2004
Resolution: Insulation for fire stop installed by crew.
Fire Fighting › Fire Hoses › Connections
Issued 19 November 2004 Resolved
Ten fire hoses unable to hold pressure.
Action required: 705 - Other - as specified
Due 19 November 2004
Resolved 20 November 2004
Resolution: Vessel received and installed ten new fire hoses.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 19 November 2004 Resolved
One liferaft is condemed. Provide additional liferaft prior to departure.
Action required: 705 - Other - as specified
Due 19 November 2004
Resolved 20 November 2004
Resolution: New liferaft delivered to vessel and properly installed.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 18 November 2004 Resolved
Fuel oil containment missing plugs.
Action required: 705 - Other - as specified
Due 26 November 2004
Resolved 20 November 2004
Resolution: Plugs have been installed.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 18 November 2004 Resolved
Combustible material found behind engine control switchboard.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2004
Resolved 19 November 2004
Resolution: Material removed by crew member.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.