← All vessels
PHILIP
Freight Ship · Bulk Carrier class · Built 1990s · USCG Northeast District (CGD-NE) · Other hulls named PHILIP
PHILIP is a 1998 freight ship. The Coast Guard has recorded 41 inspections since 2004, most recently in September 2011, along with 38 deficiencies and 17 operational controls.
Records from 2004 to 2011. Most recent: inspection, 21 September 2011.
- Built
- 1998
- Last inspected
- 21 September 2011
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 38 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9126716 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7JH3
40294
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-40294
Inspections, by type
…with no type recorded21
Years with a record
8 calendar years (2004–2011)
The 41 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it2005 - Convention (Subpart B), Net Ton
4150 - Convention (Subpart B), Gross Ton
5031 - Dead Weight, Ton
7520 - Displacement, Ton
4150 - Convention (Subpart B), Gross Ton
5031 - Dead Weight, Ton
7520 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 41
21 September 2011
Ballast Water Examination · Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4150604
20 September 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4144849
1 February 2010
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3673732
30 January 2010
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3672681
28 January 2010
NPV Safety Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3671084
25 January 2010
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3669852
25 January 2010
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3671677
2 January 2010
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3655577
20 July 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3535990
15 March 2009
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3433685
14 March 2009
ISPS I Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3430685
21 February 2009
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3421627
6 February 2009
COE-Dockside · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3413346
25 August 2008
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3308542
6 August 2008
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3290472
24 July 2008
MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3277428
11 June 2008
ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3232773
13 May 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3205595
28 December 2007
PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3121667
12 December 2007
MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3114542
28 November 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3106444
21 November 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3102196
13 November 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3097723
13 November 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3097917
13 November 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3109274
14 October 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3079772
4 October 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3073066
25 September 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3065958
22 September 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3063422
17 July 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2998220
9 April 2007
Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2904446
6 April 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2903320
20 May 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2653866
3 May 2006
ILO-147 Exam · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2639721
18 March 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2604719
22 February 2006
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2590015
22 January 2006
ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2570834
25 November 2005
ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2540493
24 July 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2437652
18 November 2004
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2243495
18 November 2004
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2243690
Deficiency record · 38
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 21 September 2011
Resolved
To enable pipes of reception facilities to be connected w/ the ship's discharge pipeline for residues from machinery bilges and from sludge, both lines shall be fitted w/ a staandard discharge connection. Vsl has 3 bolts instead of 6 on stbd side pipe. Port side pipe is rusted.
Engineering › Steering Gear System › Rudder Stock
Issued 21 September 2011
Resolved
All steering gear componetns and rudder stock shall be of sound and reliable construction to the satisfaction of the administration. Steering gear has no containment for leaks, and when the pump is running, a seawater leak flows through the rudderstock.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 21 September 2011
Resolved
One of the two means of escape from each machinery space shall be within a protected enclousure with self closing fire doors of the same fire integrity and hsall have emergency lighting provisions. Escape trunk access from the engine room and main control room are not self closing and two of the emergency lamps are inoperable.
Documentation › Logs/Records › Oil Record Book
Issued 28 January 2010
Resolved
A new ORB Part one is onboard but the vsl does not have a complete version of previous ORB readily available for inspection. CG inspectors were provided with a photo copied version dated June09. ORB should be kept onboard for three years. Vsl detained. To the satisfaction of Flag Administration. MARPOL 2006 consolidated Annex I/17.6
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 January 2010
Resolved
It was reported by crew that the OWS was repaired but not tested after repairs. MARPOL 2006 Annex I/14.6
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 January 2010
Resolved
While conducted operational tests of emergency lighting, it was discovered that several lights were inoperable. Lights at muster stations and embarkation stations were among those that did not illuminate. Vsl detained-SOLAS 2004 II-1/43.2.1 To satisfaction of class.
Electrical › Electric Generation Source (emergency) › Generator
Issued 28 January 2010
Resolved
Emergency generator starts but does not longer than 10 seconds. Several attempts were made with same results. In case of fire, emergency generator would not operate properly. Additionally, there is no evidence in the official log book that the required weekly tests were carried out. Vsl detained-SOLAS 2004 II-1/43.3.1.2 To the satisfaction of class.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 28 January 2010
Resolved
There are no entries in the SOLAS training manual that indicates crew is familiar with the use of ships lifesaving appliances, survival craft equipment and firefighting appliances. All crew has been onboard longer than two weeks. SOLAS 2004 III/19.2.1. To the satisfaction of class.
Navigation › Voyage Data Recorder › Simplified Voyage Data Recorder (SVDR)
Issued 28 January 2010
Resolved
The vessel's Voyage Data Recorder is inoperable. As per Safety Equipment Certificate, the VDR must be operational by first scheduled dryckock after 01JUL07, but no later than 01JUL10. SOLAS 2004 V/20. To the satisfaction of class.
Fire Fighting › International Shore Connection › Bolts
Issued 28 January 2010
Resolved
International shore connection is missing 04 bolts and a gasket. In the event of a fire, shore side personnel could not assist. SOLAS 74 II-2/5 (h). To the satisfaction of class.
Construction/Loadline › Structures › Door
Issued 28 January 2010
Resolved
Door leading from steering gear space to open deck has loose dogs (closing) devices. The weathertight integrity of space is compromised. ICLL 1966 Annex I/12.1. To the satisfaction of class.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 28 January 2010
Resolved
Following equipment was identified as unsatisfactory: port quarter ring buoy light inoperable, port amidship ring buoy missing and bracket broken, reflective tape on one immersion suit falling off, port quarter ring buoy (rescue boat) missing, 04 parachute flares in lifeboat expired, SART not located in freefall lifeboat. SOLAS 2004 III/20.2. To satisfaction of class.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 28 January 2010
Resolved
Lifesaving equipment in forward deck store is blocked by ships stores and is not readily accessible. SOLAS 74 III/22 (e). To satisfaction of CG.
Fire Fighting › Means of Escape › Blocked
Issued 28 January 2010
Resolved
Means of escape from engine control room is blocked by ships stores and does not allow a ready means of escape to embarkation deck. SOLAS 2004 II-2/13.1.2. To the satisfaction of CG.
Fire Fighting › Fire Hoses › Condition
Issued 28 January 2010
Resolved
While testing fire hoses on cargo deck, six hoses had significant leaks and one hose completely separated. The vessel does not have sufficient number of hoses that are available and accessible at all times. Vsl detained. SOLAS 2004 II-2/10.2.3.1.1. To the satisfaction of class.
Fire Fighting › Fire Main › Condition
Issued 28 January 2010
Resolved
During an operational test of the fire main, a leak of at least one gallon per minute was discovered. The leak is located just aft deck of cargo hatch #3. SOLAS 2004 II-2/10.2. To the satisfaction of class.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 28 January 2010
Resolved
Objective evidence discovered during an expanded examination of the safety management system onboard indicates a serious lack of effective implementation. Request external audit of SMS. Detained- SOLAS 2004 IX/3 and 5. To the satisfaction of Recognized Organization.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 25 July 2008
Resolved
PSCO's noted multiple fire screen doors which did not operate properly: 1) Doors in vicinity galley & engine room with holdbacks & not closing securely. 2) Doors in stairwell not closing securely. Class to attest to proper operation of all fire screen doors.
Solas 74 (amend.) II-2/46 & 47
To the satisfaction of class
Operations/Management › Ballast Water Managment › Submission of Report
Issued 24 July 2008
Resolved
Vessel Ballast Water Management Plan does not reflect current reporting requirements for the United States.
33 CFR151.2041
To the satisfaction of the Coast Guard
Navigation › Piloting/Steering › Gyro Compass
Issued 13 May 2008
Resolved
Vsl has an inop gyro compass.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 12 December 2007
Resolved
Vessels #4 and #5 fuel oil pumps on the Main Engine are leaking fuel oil creating a fire hazard due to heated surfaces directly below. Vessel must repair fuel oil leaks to prevent any furl oil from coming in contact with heated surfaces.
Electrical › Electric Generation Source (service) › Generator
Issued 12 December 2007
Resolved
Vessels #2 and #3 Service Generators are leaking fuel oil onto heated surfaces directly below creating a hazard. Vessel must repair fuel oil leaks to prevent any fuel oil from coming in contact with heated surfaces.
Navigation › Piloting/Steering › Magnetic Compass
Issued 12 December 2007
Resolved
Vessels Magnetic Compass was not illuminated and required removing the cover allowing natural light to enter in order to be visible.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 12 December 2007
Resolved
Vessel could not provide adequate pressure from the emergency fire pump.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 12 December 2007
Resolved
Vessel could not provide a Coast Guard Light List or Inland Nav Rules.
Electrical › Electric Generation Source (service) › Generator
Issued 12 December 2007
Resolved
Vessels impulse sensor on #1 Ships service Generator is inoperable. Vessel must make proper repairs to impulse sensor. Condition creates hazardous engine speed condition.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 13 November 2007
Resolved
Received notification a loss of propulsion. Vessel required to submit documentation from the certificate issuing authority attesting to the nature of the problem, corrective action taken, and the ability of the vessel to safely transit through the Port of Houston.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 14 October 2007
Resolved
Vessel missing starboard anchor.
Navigation › Collision/Grounding Avoidance › Radar
Issued 22 September 2007
Resolved
Primary marine radar is inoperable.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 9 April 2007
Resolved
vessel has two proximity suits, required to have fire fighting suits in compliance with FSS code.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 9 April 2007
Resolved
alarm on bridge had very low decibles for audible alarm.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 February 2006
Resolved
Automatic/retractable doors leading to engine room and AC room were not closing properly.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 January 2006
Resolved
Auto-doors to the Engine room (034a & 034), Steering Gear room, and A/C room (024) did not self-close.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 19 November 2004
Resolved
Properly seal fire stop (insulation) in steering room overhead.
Fire Fighting › Fire Hoses › Connections
Issued 19 November 2004
Resolved
Ten fire hoses unable to hold pressure.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 19 November 2004
Resolved
One liferaft is condemed. Provide additional liferaft prior to departure.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 18 November 2004
Resolved
Fuel oil containment missing plugs.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 18 November 2004
Resolved
Combustible material found behind engine control switchboard.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.