Records from 2016 to 2026. Most recent: inspection, 26 May 2026.
Inspection history · 13
26 May 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8412256
18 June 2025
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8151467
3 June 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7926552
8 June 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7801923
22 May 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7464384
1 July 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7246892
8 June 2021
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7222262
14 July 2020
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7001241
6 May 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6949278
24 May 2019
Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6698398
9 May 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6402855
19 May 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6142522
6 June 2016
Deadweight Survey · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5898949
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 June 2026
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment...
The center hull's bilge pump was inoperable at the time of inspection. Repair/replace bilge pump and provide objective evidence to the marine inspector of satisfactory operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2026
Resolved 2 July 2026
Resolution: Received video of bilge pump operating as intended.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 June 2025
Resolved
All vessels shall be provided with bilge pimps in accordance with Table 182.25-10(a). Fixed bilge pump in each pontoon (03) were inoperable at timne of inspection.
46CFR182.25-10
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 July 2025
Resolved 2 July 2025
Resolution: Vessel Rep [name withheld] provided video of all three bilge pumps working
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 June 2025
Resolved
For vessels having a square bow, the name of the vessel must be marked on some clearly visable exterior part of the bow ina manner to avaoid obliteration. The name and hailing port must be mareked on the some clearly visable exterior part of the stern. Vessels name is not marked on bow or stern.
46CFR67.123(b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2025
Resolved 2 July 2025
Resolution: Vessel rep [name withheld] provided receipt of decals of vessels name.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 June 2024
Resolved
A positive shutoff valve shall be installed at the bilge pump discharge hull penetration. Install a valve at the hull penetration. Due at next DDX.
Action required: 705 - Other - as specified
Resolved 4 June 2024
Resolution: Def cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be serviceable condition must be repaired or replaced. Ring buoy in unserviceable condition and to be removed. Vessel has another ring buoy onboard. 46 CFR 176.303(b)
Action required: 10 - Deficiency Rectified
Resolved 3 June 2024
Resolution: new bring buoy is onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 June 2024
Resolved
A vessel must be supplied with bilge pumps. All three bilge pumps are inop.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2024
Resolved 4 June 2024
Resolution: Def cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2022
Resolved
Prove proper operation of bilge pumping arrangements. Bilge pumps in all pontoons inoperable.
46 CFR 182.50
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2023
Resolution: Received video evidence of functioning bilge pump.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 May 2022
Resolved
Repair and demonstrate proper operation of stern light.
COLREGS
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2022
Resolved 8 June 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 July 2021
Resolved
Bilge alarms inoperable. Repair and demonstrate proper operation of alarms. Vessel operates on short runs and permitted to operate until corrected with requirement to run bilge pumps and verify no water intrusion in pontoons prior to each departure.
46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2023
Resolved 8 June 2023
Resolution: Witnessed operation of alarm.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 8 June 2021
Resolved
Make aft deck access ports for pontoons watertight. Seals/o-rings missing from covers.
46 CFR 179.360
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2021
Resolved 8 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 July 2020
Resolved
Properly mark life ring with retroreflective tape as required.
46 CFR 185.604 (i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 23 May 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 July 2020
Resolved
Provide documentation showing enrollment in approved DAPI program.
46 CFR 16
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2021
Engineering › Bilge Water Management System › Pump
Issued 9 May 2018
Resolved
Port bilge pump inoperable. Repair/Replace IAW 46CFR182.520
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2018
Resolved 28 June 2018
Resolution: RCVD Invoice vrom [name withheld] for bilge repair.
Engineering › Bilge Water Management System › Pump
Issued 19 May 2017
Resolved
Repair/Replace port pontoon electric submersible bilge pump IAW 46CFR182.520.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 28 June 2018
Resolution: RCVD repair invoice
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 May 2017
Resolved
Prove proper operation of stern navigation light IAW 46CFR183.420.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 9 May 2018
Resolution: 3rd annual
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 May 2017
Resolved
Provide approved first aid kit IAW 46CFR184.710.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 9 May 2018
Resolution: 3rd annual
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 May 2017
Resolved
Install 60’ of approved line on ring buoy IAW 46CFR180.70(c).
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 9 May 2018
Resolution: 3rd annual
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 May 2017
Resolved
Install 3’-6’ of line for floating water light to ring buoy with corrosion resistant clip IAW 46CFR180.70(d)(2).
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 9 May 2018
Resolution: 3rd annual
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 June 2016
Resolved
Ring buoy floating water light batteries must be replaced during the annual inspection if the expiration date of the battery has passed. Replace expired water light battery with proper type and manufacturer recomendation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 June 2016
Resolved 11 June 2016
Resolution: Vessel replaced battery in floating water light with manufacturer approved type. All, SAT.
Lifesaving › Lifebuoys › Serviceable
Issued 11 June 2016
Resolved
Vessel must carry a minimum of one servicable 24" in diameter ring life buoy IAW 46CFR180.70(a)(1). Life buoy onboard vessel was unservicable, replace with life buoy that meets the requirements of 46CFR160.050.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 June 2016
Resolved 11 June 2016
Resolution: Life buoy was replaced with approved type and size. All, SAT.