MAURY USCG vessel records
← All vessels

CARBON COPY

CARBON COPY is a 1994 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2016, most recently in May 2026, along with 20 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 26 May 2026.

Built
1994
Last inspected
26 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF4392
403191
Flag
UNITED STATES
Maury page id
psix-403191

Documentation record

Tonnage as PSIX records it3 - Regulatory (Subpart C or D), Net Ton
3 - Regulatory (Subpart C or D), Gross Ton
3 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

26 May 2026 Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8412256
18 June 2025 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8151467
3 June 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7926552
8 June 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7801923
22 May 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7464384
1 July 2021 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7246892
8 June 2021 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7222262
14 July 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7001241
6 May 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6949278
24 May 2019 Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6698398
9 May 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6402855
19 May 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6142522
6 June 2016 Deadweight Survey · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5898949

Deficiency record · 20

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 June 2026 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment... The center hull's bilge pump was inoperable at the time of inspection. Repair/replace bilge pump and provide objective evidence to the marine inspector of satisfactory operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2026
Resolved 2 July 2026
Resolution: Received video of bilge pump operating as intended.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 June 2025 Resolved
All vessels shall be provided with bilge pimps in accordance with Table 182.25-10(a). Fixed bilge pump in each pontoon (03) were inoperable at timne of inspection. 46CFR182.25-10
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 July 2025
Resolved 2 July 2025
Resolution: Vessel Rep [name withheld] provided video of all three bilge pumps working
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 June 2025 Resolved
For vessels having a square bow, the name of the vessel must be marked on some clearly visable exterior part of the bow ina manner to avaoid obliteration. The name and hailing port must be mareked on the some clearly visable exterior part of the stern. Vessels name is not marked on bow or stern. 46CFR67.123(b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2025
Resolved 2 July 2025
Resolution: Vessel rep [name withheld] provided receipt of decals of vessels name.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 June 2024 Resolved
A positive shutoff valve shall be installed at the bilge pump discharge hull penetration. Install a valve at the hull penetration. Due at next DDX.
Action required: 705 - Other - as specified
Resolved 4 June 2024
Resolution: Def cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2024 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be serviceable condition must be repaired or replaced. Ring buoy in unserviceable condition and to be removed. Vessel has another ring buoy onboard. 46 CFR 176.303(b)
Action required: 10 - Deficiency Rectified
Resolved 3 June 2024
Resolution: new bring buoy is onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 June 2024 Resolved
A vessel must be supplied with bilge pumps. All three bilge pumps are inop.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2024
Resolved 4 June 2024
Resolution: Def cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2022 Resolved
Prove proper operation of bilge pumping arrangements. Bilge pumps in all pontoons inoperable. 46 CFR 182.50
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2023
Resolution: Received video evidence of functioning bilge pump.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 May 2022 Resolved
Repair and demonstrate proper operation of stern light. COLREGS
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2022
Resolved 8 June 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 July 2021 Resolved
Bilge alarms inoperable. Repair and demonstrate proper operation of alarms. Vessel operates on short runs and permitted to operate until corrected with requirement to run bilge pumps and verify no water intrusion in pontoons prior to each departure. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2023
Resolved 8 June 2023
Resolution: Witnessed operation of alarm.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 8 June 2021 Resolved
Make aft deck access ports for pontoons watertight. Seals/o-rings missing from covers. 46 CFR 179.360
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2021
Resolved 8 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 July 2020 Resolved
Properly mark life ring with retroreflective tape as required. 46 CFR 185.604 (i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 23 May 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 July 2020 Resolved
Provide documentation showing enrollment in approved DAPI program. 46 CFR 16
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2021
Engineering › Bilge Water Management System › Pump
Issued 9 May 2018 Resolved
Port bilge pump inoperable. Repair/Replace IAW 46CFR182.520
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2018
Resolved 28 June 2018
Resolution: RCVD Invoice vrom [name withheld] for bilge repair.
Engineering › Bilge Water Management System › Pump
Issued 19 May 2017 Resolved
Repair/Replace port pontoon electric submersible bilge pump IAW 46CFR182.520.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 28 June 2018
Resolution: RCVD repair invoice
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 May 2017 Resolved
Prove proper operation of stern navigation light IAW 46CFR183.420.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 9 May 2018
Resolution: 3rd annual
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 May 2017 Resolved
Provide approved first aid kit IAW 46CFR184.710.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 9 May 2018
Resolution: 3rd annual
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 May 2017 Resolved
Install 60’ of approved line on ring buoy IAW 46CFR180.70(c).
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 9 May 2018
Resolution: 3rd annual
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 May 2017 Resolved
Install 3’-6’ of line for floating water light to ring buoy with corrosion resistant clip IAW 46CFR180.70(d)(2).
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 9 May 2018
Resolution: 3rd annual
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 June 2016 Resolved
Ring buoy floating water light batteries must be replaced during the annual inspection if the expiration date of the battery has passed. Replace expired water light battery with proper type and manufacturer recomendation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 June 2016
Resolved 11 June 2016
Resolution: Vessel replaced battery in floating water light with manufacturer approved type. All, SAT.
Lifesaving › Lifebuoys › Serviceable
Issued 11 June 2016 Resolved
Vessel must carry a minimum of one servicable 24" in diameter ring life buoy IAW 46CFR180.70(a)(1). Life buoy onboard vessel was unservicable, replace with life buoy that meets the requirements of 46CFR160.050.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 June 2016
Resolved 11 June 2016
Resolution: Life buoy was replaced with approved type and size. All, SAT.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.