Records from 1998 to 2024. Most recent: operational control imposed, 21 October 2024.
Inspection history · 59
21 October 2024
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8021952
20 October 2024
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8028150
31 May 2024
PSC A
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7919047
29 May 2024
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7921604
7 August 2017
ISPS II Exam · Ballast Water Examination · PI Safety Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6227888
3 August 2017
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6230196
19 September 2015
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5238623
18 August 2014
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4958374
14 February 2012
Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 4241107
23 September 2011
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4152523
8 February 2011
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3942498
6 February 2011
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3940284
25 October 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3979662
4 May 2009
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3466897
24 April 2009
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 3459529
28 March 2009
Internal Structural Exam · MARPOL Annex VI Survey · Hull Examination · COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 3417105
26 January 2009
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3400045
23 January 2009
Examination of Repairs · Deficiency Check · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3398924
14 May 2008
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3206670
4 April 2008
MTSA/ISPS Verification · Deficiency Check · Annual Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3197292
3 January 2008
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3124418
27 July 2007
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3009254
27 July 2007
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3009349
2 July 2007
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2981135
5 June 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2952125
15 May 2007
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2969405
9 September 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2773645
30 August 2006
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2764070
31 July 2006
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 2730193
27 July 2006
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2726789
27 June 2006
Annual Inspection · Deficiency Check · MTSA/ISPS Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2694287
2 February 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2577905
1 June 2005
MTSA/ISPS Verification · Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 2367451
27 October 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2229191
31 July 2004
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2153245
28 July 2004
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2148087
29 June 2004
MTSA/ISPS Verification
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 2112612
26 May 2004
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2079114
25 May 2004
In-Service Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2078022
8 March 2004
Internal Structural Exam · COI Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2024428
14 January 2004
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1984899
17 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1950174
17 September 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1906794
22 July 2003
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1854266
14 July 2003
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1846416
10 May 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1804732
18 July 2002
Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1648558
15 June 2002
Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1634695
6 March 2002
Underwater Inspection in lieu of Drydock
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1632832
4 September 2001
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1072817
28 August 2001
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1071429
23 July 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1439241
6 July 2001
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1065173
13 October 2000
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 143469
15 August 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 86237
28 June 2000
Initial Certification
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1365934
9 April 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 276605
1 October 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 433394
22 April 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 415139
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 14 February 2012
Resolved
Repair boiler exhaust pipe leak and replace damaged pipe insulation.
Action required: 705 - Other - as specified
Due 19 March 2014
Resolved 2 November 2013
Resolution: Received satisfactory Class report and photos from last dry dock period-Oct 2013.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 28 March 2009
Resolved
Low Pressure Fixed fire fighting CO2 system modification does not conform to MSC approved plans. Submit 'as-builts' for review and approval to CG Marine Safety Center within 30 days.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 April 2009
Resolved 5 May 2009
Resolution: Received approval letter from MSC.
Communications › Long Range Identification and Tracking (LRIT) › Transmission Unit
Issued 28 March 2009
Resolved
Commission LRIT no later than June 23, 2009 in accordance with FCC Exception.
Condition: Unknown
Due 23 June 2009
Resolved 10 September 2009
Resolution: Rvcd copy of Conformance Test Report dtd 1 May 2009 and postive feedback from U. S. LRIT Data Center that the vessel LRIT is sending positions correctly.
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 March 2009
Resolved
Provide proof of PVC piping conformance to IMO requirements in IMO resolution A.753(18) or replace to original specification material (steel) in LP CO2 refrigerations sea water cooling piping within 60 days. PVC piping and associated fittings must meet flame spread, smoke generation and toxicity requirements as well as class rules.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 May 2009
Resolved 5 May 2009
Resolution: Observed PVC piping to have been replaced with satisfactory steel piping.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 28 March 2009
Resolved
Provide 2 buoyant leader heads for line-throwing appliances within 30 days.
Condition: Improper Installation
Due 28 April 2009
Resolved 5 May 2009
Resolution: Observed new leader heads aboard vessel.
Construction/Loadline › Hull › Hull Plating
Issued 24 January 2009
Resolved
Properly repair to the satisfaction of Coast Guard and ABS the damaged hull plating between frames 25 and 27 (stbd side, aft, at turn of the bilge) IWO of the engine room. Repair to be conducted in accordance with ABS rules. Hull plating was punctured as a result of allision with pier upon arrival in the Port of Baltimore on 24JAN09. CG-2692 is attached.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2009
Resolved 24 January 2009
Resolution: Satisfactory insert installed and tested.
Construction/Loadline › Hull › Hull Plating
Issued 24 January 2009
Resolved
Upon arrival at shipyard in Singapore provide repair proposal to Coast Guard Activities Far East for damage to starboard side hull plating (aft at turn of the bilge) between frames 27 and 45. Damage sustained as a result of allision with the pier at the Port of Baltimore on 24JAN09. Damage in this area does not impact the safety of the vessel. CG-2692 is attached.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2009
Resolved 30 March 2009
Resolution: Vessel inserted subject area to the satisfaction of attending ABS Surveyor and CG Marine inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 5 April 2008
Resolved
Provide Unitor report for satisfactory service of LP CO2, portable extinguishers, EEBD's, and SCBA's.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2008
Resolved 6 April 2008
Resolution: Received report via master
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 5 April 2008
Resolved
Perform overdue periodic machinery maintenance. Example of overdue items: Control Air Filters, Water Filters, ME LO Pumps, ME Cylinder head/exhaust valves, Air Compressors, LO Purifiers, Vent Dampers, Fire Alarms,
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 May 2008
Resolved 7 May 2008
Resolution: Received documenation of performed maintenance
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 5 April 2008
Resolved
Perform general housekeeping of machinery space, especially oil soaked machinery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 7 May 2008
Resolution: Received documenation of performed maintenance.
Engineering › Fuel Oil Service System › Piping
Issued 5 April 2008
Resolved
Replace oil soaked lagging on ME, SDG's and purifier room piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 7 May 2008
Resolution: Received documenation of performed maintenance
Fire Fighting › Fire Hydrants › Condition
Issued 5 April 2008
Resolved
Perform periodic maintenance of machinery space fire stations.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 May 2008
Resolved 7 May 2008
Resolution: Received documenation of performed maintenance
Fire Fighting › Fire Hoses › Condition
Issued 5 April 2008
Resolved
Conduct hydro test of all fire hoses. Two decks not accessible until discharge in Port Hueneme, CA 12MAY08.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2008
Resolved 14 May 2008
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 5 April 2008
Resolved
Submit periodic saftey test procedures to USCG Marine Safety Center for review or prove this wsas completed prior to BALMS approval of PTSP 31JUL04.
Due 5 May 2008
Resolved 2 May 2008
Resolution: Phonecon w/MSC confirms review. See MSC Letters E2-030-7315 and E2-0306179.
Lifesaving › Immersion Suits › Serviceable
Issued 5 April 2008
Resolved
Immersions suits (36) must be on board ship at all times vessel is underway outside 32 degrees N/S latitude.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2008
Resolved 6 April 2008
Resolution: Report received from master 19 serviced, 5 repaired, 12 replaced.
Engineering › Diesel Engine (auxiliary) › Bedplate
Issued 4 April 2008
Resolved
Locate and secure source of machinery oil leaks on ME and SDG 1-3 by completion of class surveys.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 7 May 2008
Resolution: Received 2 page documention of repaired leaks
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 15 May 2007
Resolved
Provide CO2 Level Gauge (alarm) for CO2 System.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 2 July 2007
Resolution: Received e-mail confirmation that gauge was repaired and is operating satisfactorily.
Engineering › Fuel Oil Service System › Hose
Issued 27 June 2006
Resolved
#2 SSDG F/O low pressure switch supply line leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2006
Resolution: Replaced low pressure switch, (switch was leaking not line)
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Turbocharger
Issued 27 June 2006
Resolved
#3 SSDG Turbo Charger making loud noise at high loads. This generator is not to be used except in emergency until repairs are made.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2006
Resolved 30 August 2006
Resolution: Cleared deficiency due to receipt of ABS Survey Report. Vessel made repairs by replacing the defective #2 cylinder cover and cleaning the carbon/soot from intake manifold.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 27 June 2006
Resolved
Remove/Clean excessive oil form bilge containment under SSDG
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2006
Resolution: Satisfactory cleaned containment area.
Engineering › Fuel Oil Service System › Valve
Issued 27 June 2006
Resolved
MDE fuel oil supply and return lines for injection pumps are leaking excessively and insulation blankets are saturated with F/O. Repair leaks and renew insulation blankets.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 June 2006
Resolved 27 June 2006
Resolution: All valve seals replaced, and insulation blankets renewed.
Lifesaving › Lifeboat › Hull
Issued 27 June 2006
Resolved
Starboard Life Boat has damaged gel coat on port bow.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2006
Resolved 30 August 2006
Resolution: Cleared deficiency due to receipt of ABS survey report. Vessel made gelcoat repairs to starboard side bow of port lifeboat.
Lifesaving › Lifeboat › Carriage Requirement
Issued 27 June 2006
Resolved
Both Port and Starboard Life Boats have food packages (provisions) that have lost there seal, remove bad packages and ensure the proper amount of packages are onboard each boat.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2006
Resolution: Removed bad packages and counted remaining packages, both boats have required amount of packages onboard.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 27 June 2006
Resolved
110 volt distribution panel shows a ground. Make repairs as necessary.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2006
Resolution: Repaired ground on 110 volt panel.
Engineering › Fuel Oil Service System › Piping
Issued 28 May 2004
Resolved
Renew laging on pipe works port side HFO circ pump in purifier room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2004
Resolved 31 July 2004
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 27 May 2004
Resolved
Expanded ISM exam indicaes non-conformitiesare not dealt with by the company (ISM CODE 6 & 10), Conduct external audit of companies SMS by a recognised organization and provide report to [name withheld].
Condition: Unknown
Due 27 June 2004
Resolved 20 July 2004
Resolution: Received copies of Audit.
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 27 May 2004
Resolved
Condition of equipment is evidence of possible SMS failure, conduct external audit of vessels SMS prior to departing U.S. waters and provide copy to [name withheld].
Due 27 June 2004
Resolved 20 July 2004
Resolution: Received copies of Audit.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 26 May 2004
Resolved
Renew high pressure fuel oil delivery piping to MDE #5 cylinder, demonstrate proper operation to show system is no longer leaking. LEGACY COMPONENT DESC: Injector (fuel injection)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2004
Resolution: Renewed fuel injector delivery pipe, witnessed satisfactory operation.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 26 May 2004
Resolved
Clean the machinery spaces in the vicinity of the MDE, all areas sprayed w/HFO due to leakage, bulkheads, machinery flats area, bilges and associatedpiping to be degreased. Remove all flammables and stow as required.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2004
Engineering › Fuel Oil Service System
Issued 26 May 2004
Resolved
Clean the HFO centrifuge room bilge flats and all installed machinery and bulkheads.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2004
Engineering › Fuel Oil Service System
Issued 26 May 2004
Resolved
Repair leaks on the HFO centrifuges and associated pumps and stariners. LEGACY COMPONENT DESC: Filter
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2004
Engineering › Steam System (auxiliary) › Piping
Issued 26 May 2004
Resolved
Replace expansion ducting from forced air blower to boiler inlet. Presently sealed with duct or packing tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 June 2004
Resolved 31 July 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 26 May 2004
Resolved
Prove proper operation of the port side 6 deck emergency escape.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2004
Fire Fighting › Fire Pumps › Pumpshaft
Issued 26 May 2004
Resolved
Repair leaking shaft glands on the emregency fire pump and associated priming pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 June 2004
Resolved 31 July 2004
Engineering › Steam System (auxiliary) › Piping
Issued 26 May 2004
Resolved
Make permanent repairs to the generator HFO steam heating line strbd side of centrifuge room overhead. Presently has a soft ptch in place. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 26 June 2004
Resolved 31 July 2004
Documentation › Logs/Records › Logbook (official)
Issued 26 May 2004
Resolved
Provide copies of ships logs from 3 Apr 04 to 26 Mar 04 to include copies of company and official logs. LEGACY COMPONENT DESC: Logbook (official)
Condition: Unknown
Due 5 June 2004
Resolved 20 July 2004
Accommodation/Occupational Safety › Ventilation
Issued 14 January 2004
Resolved
Provide a repair proposal to CG Activities Baltimore to replace overhead paneling in the Engine Control Room and a means to prevent the saturation of paneling from moisture due to overhead ventilation ducting. Ensure area above main switchboard is included in the repair. Complete repairs.
Due 31 March 2004
Resolved 18 March 2004
Engineering › Diesel Engine (auxiliary)
Issued 22 July 2003
Resolved
Repair #1 and #3 generator overpseed protection device to the satisfaction of the attending Coast Guard Inspector. LEGACY COMPONENT DESC: Overspeed Device
Action required: 705 - Other - as specified
Due 22 September 2003
Resolved 24 July 2003
Resolution: Test and repairs were satisfactory to the attending inspector, for both generators.
Personnel › Manning/Qualifications
Issued 21 July 2003
Resolved
Provide this office a copy of vessel's manning reduction approval letter, issued by the USCG as per Marine Safety Manual Volume III, Chapter 25, paragraph A.3.a. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 2 January 2004
Resolution: Provided class certificate bearing the code ACCU meaning that the vessel has met the automation system design and failsafe requirements of SOLAS in lieu of technical plan review of vital system automation by the USCG.
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 21 July 2003
Resolved
Provide this office a copy of vessel's Periodic Safety Test Procedure, approved by the USCG as per 46 CFR 61.40-1(a).
Action required: 705 - Other - as specified
Due 18 June 2004
Resolved 31 July 2004
Resolution: Witnessed proper testing of PSTP. Stamped PSTP approved.
Engineering › Diesel Engine (auxiliary)
Issued 14 July 2003
Resolved
Prove proper operation of Low L/O Pressure Shut Down on #'s 1, 2, and 3 ships service generators as per 74/78 SOLAS (2001) II-1/27.5.
Action required: 705 - Other - as specified
Due 22 July 2003
Resolved 22 July 2003
Resolution: Repaired and tested to the satisfactory of the attending CG inspector.
Engineering › Diesel Engine (auxiliary)
Issued 14 July 2003
Resolved
Prove proper operation of Overspeed Trips on #'s 1, 2, and 3 ships service generators as per 74/78 SOLAS (2001) II-1/27.1. LEGACY COMPONENT DESC: Overspeed Device
Action required: 705 - Other - as specified
Due 22 July 2003
Resolved 22 July 2003
Resolution: # 2 generator overspeed Repaired and tested to the satisfactory of the attending CG inspector.
Electrical › Electric Generation Source (service)
Issued 14 July 2003
Resolved
Panelboards EL-K/Emer Light Dist Board, DC-B/Common Dist Board, L-K/Light Dist Board, all located in Engine Control Room are missing covers which expose energized circuits. Install covers as per 74/78 SOLAS (2001) II-1/45.1.3 LEGACY COMPONENT DESC: Panelboard
Action required: 705 - Other - as specified
Due 22 July 2003
Resolved 22 July 2003
Resolution: Repaired and tested to the satisfactory of the attending CG inspector.
Construction/Loadline › Hull
Issued 14 July 2003
Resolved
Repair buckeled overhead, frame, and trip bracket in hold # 2, 3rd Deck, on Starboard side Frame 125 as per 74/78 SOLAS (2001) I/11.b. Due date is next scheduled dry dock. LEGACY COMPONENT DESC: Side Shell
Action required: 705 - Other - as specified
Due 31 March 2004
Resolved 18 March 2004
Engineering › Diesel Engine (auxiliary)
Issued 14 July 2003
Resolved
Repair as to original, # 3 SSG L/O tubing on forward end of engine. Tubing contains a soft patch. 74/78 SOLAS (2001) I/11.b.
Action required: 705 - Other - as specified
Due 22 July 2003
Resolved 22 September 2003
Resolution: Repaired and tested to the satisfactory of the attending CG inspector.
Personnel › Manning/Qualifications
Issued 14 July 2003
Resolved
Engine Room is required to be manned until Activities Baltimore CG-835's BA01 and BA02 dated 14 July 2003 are cleared to the satisfaction of attending CG Marine Inspector. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 705 - Other - as specified
Due 22 September 2003
Resolved 24 July 2003
Resolution: CG-835 for Engine Room manning requirements for BA01 and BA02 were cleared to the satisfaction of the attending CG inspector.