← All vessels
GANT VISION
GANT VISION is a 1992 freight ship. The Coast Guard has recorded 20 inspections since 1995, most recently in July 2009, along with 9 deficiencies and 3 operational controls.
Records from 1995 to 2009. Most recent: inspection, 30 July 2009.
- Built
- 1992
- Last inspected
- 30 July 2009
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9047049 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HHJ7
403522
Flag
MALTA
—
Maury page id
psix-403522
Inspections, by type
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it25899 - Regulatory (Subpart C or D), Gross Ton
13673 - Regulatory (Subpart C or D), Net Ton
43536 - Dead Weight, Ton
51680 - Displacement, Ton
13673 - Regulatory (Subpart C or D), Net Ton
43536 - Dead Weight, Ton
51680 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
30 July 2009
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3550793
6 January 2009
ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3380782
19 December 2008
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3380894
28 April 2005
Annual Inspection · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2344668
27 April 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2344060
26 March 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2031595
7 May 2003
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1793519
24 March 2003
Deficiency Check · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1761816
19 March 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1759729
17 April 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1603378
2 February 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 286741
29 January 2001
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 286081
21 April 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 277082
6 March 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 426281
6 February 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 425319
4 July 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 417599
29 July 1997
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 406133
18 June 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 392476
11 November 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 384734
5 February 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 374941
Deficiency record · 9
Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 26 March 2004
Resolved
NO WAY TO SHUT OFF FLOW OF FUEL TO EMERGENCY GENERATOR FROM OUTSIDE OF EMERGENCY GENERATOR SPACE. FUEL OIL TANK IS GREATER THAN 500 LITERS. IT HAS A 725 LITER CAPACITY. CITE: USCG NVIC 10-99. CLASS TO ADDRESS WITHIN 90 DAYS. LEGACY COMPONENT DESC: Remote valve for fuel system
Engineering › Diesel Engine (propulsion-direct drive)
Issued 7 May 2003
Resolved
MAKE PERMANENT REPAIRS TO PROPULSION SYSTEM.
Navigation › Piloting/Steering
Issued 24 March 2003
Resolved
Inoperable gyro compass. Gyro compass is off by approximately 30 degrees. 33 CFR 164.35(d). Provide technician's report for satisfactory operation prior to departure from port. LEGACY COMPONENT DESC: Gyro Compass
Navigation › Collision/Grounding Avoidance
Issued 24 March 2003
Resolved
ARPA is inoperable (due to inoperable gyro compass). 33 CFR 164.38. Provide technician's report for satisfactory operation prior to departue from port. LEGACY COMPONENT DESC: Automatic Radar Plotting Aid (ARPA)
Navigation › Piloting/Steering
Issued 24 March 2003
Resolved
Unable to conduct main steering gear and rudder stock tests due to inoperable gyro compass/steering system. Solas 74/78, Ch. II-1, Reg. 29, 3.2. Correct prior to departure from port. LEGACY COMPONENT DESC: Steering test
Accommodation/Occupational Safety › Occupational Safety
Issued 24 March 2003
Resolved
Non-Conductive mats are missing from in front of control panels throughout the engine compartment. Solas 74/78, Ch. II-1, Reg. 45,/2. Correct prior to next U.S. port after sailing foreign. LEGACY COMPONENT DESC: Non-conductive Flooring
Navigation › Collision/Grounding Avoidance
Issued 17 April 2002
Resolved
THREE LINKS OF PORT ANCHOR CHAIN HAVE BROKEN/MISSING STUDS TO LINK. LEGACY COMPONENT DESC: ANCHOR CHAIN
Navigation
Issued 6 February 1999
Resolved
The vessel charts were not updated to the most recent corrections_x001C_
Navigation
Issued 6 February 1999
Resolved
The ARPA screen was inoperative.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.