MAURY USCG vessel records Sign in
← All vessels

GANT VISION

GANT VISION is a 1992 freight ship. The Coast Guard has recorded 20 inspections since 1995, most recently in July 2009, along with 9 deficiencies and 3 operational controls.

Records from 1995 to 2009. Most recent: inspection, 30 July 2009.

Built
1992
Last inspected
30 July 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9047049 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
403522
Flag
MALTA
—
Maury page id
psix-403522

Inspections, by type

…with no type recorded13
Years with a record 13 calendar years (1995–2009)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it25899 - Regulatory (Subpart C or D), Gross Ton
13673 - Regulatory (Subpart C or D), Net Ton
43536 - Dead Weight, Ton
51680 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

30 July 2009 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3550793
6 January 2009 ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3380782
19 December 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3380894
28 April 2005 Annual Inspection · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2344668
27 April 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2344060
26 March 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2031595
7 May 2003 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1793519
24 March 2003 Deficiency Check · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1761816
19 March 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1759729
17 April 2002 Ballast Water Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1603378
2 February 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 286741
29 January 2001 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 286081
21 April 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 277082
6 March 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 426281
6 February 1999 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 425319
4 July 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 417599
29 July 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 406133
18 June 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 392476
11 November 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 384734
5 February 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 374941

Deficiency record · 9

Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 26 March 2004 Resolved
NO WAY TO SHUT OFF FLOW OF FUEL TO EMERGENCY GENERATOR FROM OUTSIDE OF EMERGENCY GENERATOR SPACE. FUEL OIL TANK IS GREATER THAN 500 LITERS. IT HAS A 725 LITER CAPACITY. CITE: USCG NVIC 10-99. CLASS TO ADDRESS WITHIN 90 DAYS. LEGACY COMPONENT DESC: Remote valve for fuel system
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 June 2004
Resolved 28 April 2005
Resolution: USCG Foreign Freight Inspector tested recently installed remote shutoff. System works effectively and deficiency is cleared.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 7 May 2003 Resolved
MAKE PERMANENT REPAIRS TO PROPULSION SYSTEM.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 May 2003
Resolved 13 May 2003
Resolution: RECEIVED CLASS REPORT STATING THAT REPAIRS HAVE BEEN MADE.
Navigation › Piloting/Steering
Issued 24 March 2003 Resolved
Inoperable gyro compass. Gyro compass is off by approximately 30 degrees. 33 CFR 164.35(d). Provide technician's report for satisfactory operation prior to departure from port. LEGACY COMPONENT DESC: Gyro Compass
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2003
Resolution: Reviewed technician''''''''s report and visually inspected gyro compass for proper operation. Compass is operating satisfactorally.
Navigation › Collision/Grounding Avoidance
Issued 24 March 2003 Resolved
ARPA is inoperable (due to inoperable gyro compass). 33 CFR 164.38. Provide technician's report for satisfactory operation prior to departue from port. LEGACY COMPONENT DESC: Automatic Radar Plotting Aid (ARPA)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2003
Resolution: ARPA back in operation after repair to gyro compass. Visually inspected and tested ARPA and radar capabilities. All tests satisfactory.
Navigation › Piloting/Steering
Issued 24 March 2003 Resolved
Unable to conduct main steering gear and rudder stock tests due to inoperable gyro compass/steering system. Solas 74/78, Ch. II-1, Reg. 29, 3.2. Correct prior to departure from port. LEGACY COMPONENT DESC: Steering test
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2003
Resolution: Conducted main steering gear and and emergency loss of power alarm tests now that gyro compass is back in order. All satisfactory.
Accommodation/Occupational Safety › Occupational Safety
Issued 24 March 2003 Resolved
Non-Conductive mats are missing from in front of control panels throughout the engine compartment. Solas 74/78, Ch. II-1, Reg. 45,/2. Correct prior to next U.S. port after sailing foreign. LEGACY COMPONENT DESC: Non-conductive Flooring
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 March 2003
Resolution: Reviewed receipt for purchase of non-conductive mats and visually inspected new mats in the engine room.
Navigation › Collision/Grounding Avoidance
Issued 17 April 2002 Resolved
THREE LINKS OF PORT ANCHOR CHAIN HAVE BROKEN/MISSING STUDS TO LINK. LEGACY COMPONENT DESC: ANCHOR CHAIN
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 July 2002
Resolved 24 March 2003
Resolution: Deficiency cleared by classification survey dated 14 DEC 02, attesting to replacement of links of Port side anchor chain.
Navigation
Issued 6 February 1999 Resolved
The vessel charts were not updated to the most recent corrections_x001C_
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Navigation
Issued 6 February 1999 Resolved
The ARPA screen was inoperative.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.