JADRAN
Freight Ship · Bulk Carrier class · Built 1980s · USCG Northwest District (CGD-NW) · Other hulls named JADRAN
JADRAN is a 1982 freight ship. The Coast Guard has recorded 29 inspections since 1997, most recently in June 2008, along with 14 deficiencies and 6 operational controls.
Records from 1997 to 2008. Most recent: inspection, 21 June 2008.
- Built
- 1982
- Last inspected
- 21 June 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 14 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7925364 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7NS9
403668
Flag
LIBERIA
—
Maury page id
psix-403668
Inspections, by type
…with no type recorded16
Years with a record
11 calendar years (1997–2008)
The 29 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it24271 - Convention (Subpart B), Net Ton
40258 - Convention (Subpart B), Gross Ton
70947 - Dead Weight, Ton
85082 - Displacement, Ton
40258 - Convention (Subpart B), Gross Ton
70947 - Dead Weight, Ton
85082 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 29
21 June 2008
ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3238875
9 February 2007
ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2868607
24 January 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2860459
3 February 2006
MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2575541
21 October 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2225699
27 September 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2206932
22 July 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2141556
1 July 2004
PII Safety Exam · ISPS II Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2113575
27 February 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2014278
27 January 2004
Re-Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1993714
14 October 2003
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1935200
24 June 2003
Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1825813
23 June 2003
Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1824900
16 June 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1810400
13 January 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1729533
29 May 2002
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1622469
16 May 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1615830
4 February 2002
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1483596
2 February 2002
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1484015
2 February 2002
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1484115
11 March 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 287807
28 January 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 273976
14 October 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 433365
18 January 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 424252
4 August 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 418668
29 December 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 411290
31 July 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 406389
26 February 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 400917
27 January 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 399706
Deficiency record · 14
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 9 February 2007
Resolved
Emergency fire pump inoperable, Clutch between engine shaft and pump shaft is damaged. Emergency fire pump is unable to draw suction and supply firefighting water. Reticfy to vessels class society.
Deck/Cargo › Ballast › Piping
Issued 9 February 2007
Resolved
Vessel has a cement patch on the ballast water supply line directly adjacent to the #2 ballast pump.
Engineering › Bilge Water Management System › Pump
Issued 9 February 2007
Resolved
General service pump shaft seal cooling line has three small pinholes spraying steady streams of water. Rectify to the satisfaction of the attending classification society.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 February 2007
Resolved
Lower handrail on port side directly foward of the #5 double bottom tank (aft vent) is broken off at the support structure.
Deck/Cargo › Ballast
Issued 13 January 2003
Resolved
FOUND CEMENT PATCH ON BALLAST OVERBOARD PIPE INBOARD OF VALVE. MAKE PERMANENT REPAIRS TO SATISFACTION OF CLASS SOCIETY. LEGACY COMPONENT DESC: Piping
Deck/Cargo › Holds/Tanks
Issued 13 January 2003
Resolved
MAKE PERMANENT REPAIRS TO HATCH COAMING BRACKETS ON #5 AND #2 HATCHES TO SATISFACTION OF CLASS SOCIETY. LEGACY COMPONENT DESC: Coaming
Lifesaving › Lifeboat Equipment
Issued 13 January 2003
Resolved
REPLACE DAMAGED/MISSING FOOD RATIONS FOR A TOTAL OF 3 RATIONS TOTALING NOT LESS THAN 10,000 KJ EACH. FAX RECEIPT TO COTP BALTIMORE PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Food Ration
Lifesaving › Lifebuoys
Issued 16 May 2002
Resolved
Forward liferings (Port and Starboard) have wasted containment. Metal wire used to hold liferings in place. LEGACY COMPONENT DESC: Stowage
Construction/Loadline › Hull
Issued 5 February 2002
Resolved
PRIOR TO DEPARTING NEXT U.S. PORT PROVIDE CLASS REPORT ATTESTING TO CONDITION OF BOTTOM OF VESSEL IN WAY OF GROUNDING. LEGACY COMPONENT DESC: 0999
Construction/Loadline › Hull
Issued 1 February 2002
Resolved
POSSIBLE DAMAGE CAUSED FROM VESSEL GROUNDING LEGACY COMPONENT DESC: Bottom Plating
Construction/Loadline
Issued 11 March 2001
Resolved
Bilge pump in poor condition. Numerous leaks noted during operation. Alsoone valve failed to remain secured allowing 4ft spray of H2O.
Fire Fighting
Issued 11 March 2001
Resolved
Fire drill was unsatisfactory. Crew unfamiliar with equipment. Also unsafe response to entry. Fire drill to be practiced by crew and performedto satisfaction of USCG inspectors.
Construction/Loadline
Issued 11 March 2001
Resolved
#5 hold port side forward radius cracked. To be repaired and inspected by USCG.
Lifesaving
Issued 27 January 1997
Resolved
RENEW THE DETERIORATED EXPOSURE COVERS FOR THE PORT AND STARBOARD LIFEBOATSWITH APPROVED COVERS OF A HIGHLY VISIBLE COLOR CAPABLE OF PROTECTING THE OCCUPANTS AGAINST INJURY BY EXPOSURE._x001C_ SEE SOLAS 74 III/11(a)(xxvi)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.