Records from 1994 to 2026. Most recent: inspection, 21 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 36
21 April 2026
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8354040
16 April 2025
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8129546
15 August 2022
COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7531906
13 April 2022
Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7431927
9 July 2021
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7250927
14 June 2021
Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7226316
22 April 2021
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7189232
21 May 2020
Simplified Stability Test
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6973091
5 August 2019
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6810861
7 May 2019
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6718970
13 December 2018
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6597190
18 April 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6440993
20 April 2017
Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6146925
12 April 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5844761
11 March 2014
Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4813355
29 April 2009
Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3465454
3 March 2009
Hull Examination · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3430488
23 April 2008
Deficiency Check · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3179462
18 January 2008
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3132870
8 May 2007
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2940447
17 April 2007
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2916814
7 March 2006
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2597472
18 April 2005
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2318866
9 February 2005
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2283787
2 June 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2101448
12 April 2004
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2000346
21 April 2003
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1942614
22 April 2002
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1618573
16 April 2001
Deficiency Check · Hull Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1065351
28 April 2000
COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1052687
15 April 1999
Deficiency Check · Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1384184
20 April 1998
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1124055
17 April 1997
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 774809
22 April 1996
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1182397
15 March 1995
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1355134
2 May 1994
Initial Construction-Excluding Oversight · Hull Examination · Plan Review "T" Boat · Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1356622
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 August 2022
Resolved
A [flammable vapor detection] sensor must be located above the expected bilge water level in...the lowest part of a machinery space. Fume sensor had detached from bulkhead and was in the bilge. Secure sensor above expected bilge water level.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2022
Resolved 16 April 2025
Resolution: Vapor detector installed correctly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2022
Resolved
A conductor of a control, interlock, or indicator circuit...must be protected by an overcurrent device, and an emergency switch must be provided in the normally ungrounded main supply conductor from the battery. No overcurrent devices or battery switches were seen at time of inspection. Provide overcurrent protection and battery emergency switch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2022
Resolved 16 April 2025
Resolution: Vessel added battery switch and over current protection
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 August 2022
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. No vessel log or record of training was on board vessel. Provide record of crew training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2022
Resolved 16 April 2025
Resolution: Drills and training are actively being conducted and logged.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 August 2022
Resolved
Each...ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Ring life buoy was unmarked. Mark ring life buoy with vessel name.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2022
Resolved 16 April 2025
Resolution: Ring life buoy has been marked with vessel name.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 August 2022
Resolved
A pre-engineered fixed gas fire extinguishing system must...automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space; and...must have the following equipment at the operating station:...a means to reset devices used to automatically shut down ventilation systems and engines. Vessel's pre-engineered fire extinguishing system was unable to automatically shut down ventilation and engines. Provide automatic shutdown capability and means of override at operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2022
Resolved 16 April 2025
Resolution: Fireboy shuts down ventilation and over ride switch is functional.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 August 2022
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child size life jackets were stowed in same compartment as adult life jackets. Provide physical separation of child and adult life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2022
Resolved 16 April 2025
Resolution: Vessel has been moved to Grants Pass where it conducts whiewater trips and passengers must wear lifejackets during operation.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 August 2022
Resolved
A vessel must comply with the applicable requirements for any radio...including the requirements for a station license and installation certificates to be issued by the FCC. Vessel had no station license or safety radio certificate on board. Provide valid FCC certificates.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2022
Resolved 16 April 2025
Resolution: Vessel moved to Grants Passand is exempt from FCC station and safet radio cert
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 15 August 2022
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station...must carry a radio operator who...hold[s] a marine radio operator permit or higher class license. Operator was unable to produce marine radio operator permit. Confirm carriage of radio operator permit for master. 47 CFR 80.159(e)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2022
Resolved 16 April 2025
Resolution: Vessel moved to Grants Pass, exempt from FCC regs
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 June 2021
Resolved
Fire protective devices. Electrical apparatus which operates as part of, or in conjunction with, a fire protective device installed on board the vessel shall be tested by operation. Vessel's vapor detection system not tested. Complete valid test to provide proper functionality.
46 CFR 176.25-15 (6) Old T
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2021
Resolved 28 June 2021
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 June 2021
Resolved
Spaces containing gasoline machinery or fuel tanks shall have natural supply and mechanical exhaust ventilation. Port side engine room ventilation fan not operational. Fix blower fan to provide adequate ventilation for engine room space.
46 CFR 182.15-45 (a) Old T
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 June 2021
Resolved
Distress flares and smoke signals. A vessel on a lakes, bays, and sounds, or rivers route must carry: three hand red flare distress signals and three hand orange smoke distress signals.
46 CFR 180.68 (b)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 June 2021
Resolved
Bilge and Ballast systems. All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Vessel's bilge high level audio alarm and automatic switch for the bilge system inoperable. Fix faulty components of bilge system.
46 CFR 182.25-1 (a) Old T
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: Corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 June 2021
Resolved
Employers must ensure that they and their crewmembers meet the requirements of this part. Drug and alcohol program records not available for inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2021
Resolved 28 June 2021
Resolution: Corrected.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 3 March 2009
Resolved
Replace fuel fill and fuel tank vent lines IAW 46 CFR 182.445 and .450
Due 10 March 2009
Resolved 13 March 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 April 2008
Resolved
Update First Aid Kit
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2008
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2008
Resolved
Properly drill stop, v/w fracture on stbd side amidships.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2008
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2008
Resolved
v/w transom IWO center post of jet guard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2008
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 18 January 2008
Resolved
Random pool element missing from MIS.
Action required: 705 - Other - as specified
Due 18 January 2008
Resolved 18 January 2008
Resolution: New, updated report sent.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 18 January 2008
Resolved
EAP display not posted.
Action required: 705 - Other - as specified
Due 18 January 2008
Resolved 18 January 2008
Resolution: Display posted.
Construction/Loadline › Hull › Weld
Issued 17 April 2007
Resolved
Drill stop crack IWO engine cover.
Due 30 April 2007
Resolved 25 May 2007
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 17 April 2007
Resolved
Place newly ordered lifejackets on vessel when they arrive prior to operating with passengers. Notify Coast Guard Marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2007
Resolved 25 May 2007
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 12 April 2004
Resolved
Make blowers for engine compartment shut down during fixed fire fighting system discharge. 46 CFR 182.460(d). Correct to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper Installation
Due 13 June 2004
Resolved 2 June 2004
Resolution: Corrected.
Lifesaving
Issued 16 April 2001
Resolved
PROVIDE MAN OVERBOARD AND FIRE DRILL RECORDS OR CONDUCT DRILLS FOR ATTENDING CG INSPECTOR.
Condition: Unknown
Due 14 May 2001
Resolved 15 June 2001
Unknown
Issued 16 April 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 May 2001
Resolved 15 June 2001
Lifesaving
Issued 16 April 2001
Resolved
PROVIDE CLIPS FOR LIFE RING WATERLIGHT AND PERMANENTLY UN-TIE LIFE RING LINE FROM VESSEL.
Condition: Unknown
Due 14 May 2001
Resolved 15 June 2001
Lifesaving
Issued 28 April 2000
Resolved
PROVIDE OPERATIONAL TESTING AND FIRE/MAN OVERBOARD DRILLS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR
Condition: Unknown
Due 1 June 2000
Resolved 31 July 2000
Construction/Loadline
Issued 28 April 2000
Resolved
PROVIDE DOUBLE CLAMPS FOR ALL THRU HULL PENETRATIONS UP TO SEA VALVES.
Condition: Unknown
Due 1 June 2000
Resolved 31 July 2000
Lifesaving
Issued 15 April 1999
Resolved
PROVIDE LIFEJACKETS ON BOARD AND PROPERLY LABELED
Condition: Unknown
Due 6 May 1999
Resolved 29 June 1999