MAURY USCG vessel records Sign in
← All vessels

AMFITRITE

AMFITRITE is a freight ship. The Coast Guard has recorded 7 inspections since 1998, most recently in June 2003, along with 19 deficiencies.

Records from 1998 to 2003. Most recent: inspection, 2 June 2003.

Built
Not recorded
Last inspected
2 June 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8003773 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
403760
Flag
PANAMA
—
Maury page id
psix-403760

Inspections, by type

…with no type recorded3
Years with a record 4 calendar years (1998–2003)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it4627 - Regulatory (Subpart C or D), Net Ton
10364 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 7

2 June 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1808056
21 May 2003 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1798074
16 May 2003 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1794773
30 December 2002 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1723056
28 October 2002 Ballast Water Examination · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1695108
24 October 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 294980
7 April 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 414554

Deficiency record · 19

Operations/Management › Drills/Instruction
Issued 21 May 2003 Resolved
TRAINING MANUAL NOT IN WORKING LANGUAGE OF THE CREW. LEGACY COMPONENT DESC: Safety Orientation
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 27 May 2003
Resolution: AGENT PROVIDED VESSEL WITH TRAINING MANUAL IN CREWS LANGUAGE.
Personnel › Certificates/Documents/Licenses
Issued 28 October 2002 Resolved
No edorsement by Flag State for Crew/Officer Licenses, LEGACY COMPONENT DESC: STCW Endorsement
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 November 2002
Lifesaving › Lifeboat
Issued 28 October 2002 Resolved
Starboard side lifeboat has patch work to hull. Class to provide report on condition prior to departure. LEGACY COMPONENT DESC: Hull
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 November 2002
Lifesaving › Lifeboat
Issued 28 October 2002 Resolved
Port side Life Boat show's evidence of water in Hull. Has rust stains and pin holes. Class to provide report prior to departure. LEGACY COMPONENT DESC: Hull
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 November 2002
Pollution Prevention/Response › Prevention Equipment
Issued 28 October 2002 Resolved
Mechanical plugs missing from all bunkering stations on deck. LEGACY COMPONENT DESC: Fixed Containment
Due 1 December 2002
Resolved 30 December 2002
Engineering
Issued 28 October 2002 Resolved
Excessive oil in shaft alley bilge. Water and oil in engine room bilge.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 November 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 28 October 2002 Resolved
Paint locker vent closure mssing natural vent. Install proper vent.
Due 1 December 2002
Resolved 30 December 2002
Operations/Management › Drills/Instruction
Issued 28 October 2002 Resolved
Fire drill unsat. Coordination between bridge and fire parties not satisfactory. Crew not familiar with duties. LEGACY COMPONENT DESC: Fire
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2002
Navigation
Issued 24 October 2001 Resolved
VSL HAD NO CURRENT NOTICE TO MARINERS ONBOARD, MUST PROVIDE UP TO DATE NOTICE AND UP DATE CHARTS PRIOR TO DEPARTURE.
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Accommodation/Occupational Safety
Issued 24 October 2001 Resolved
EXPIRED MEDICATION ONBOARD, RENEW EXPIRED MED, FAX RECIEPT TO MSO PRIOR TO DEPARTURE
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Accommodation/Occupational Safety
Issued 24 October 2001 Resolved
PEST/BUGS RUNNING AROUND VSL IN GALLEY AND DRY STORES, HAVE PEST CONTROL COMPANY ATEND TO VSL, PRIOR TO DEPARTURE FROM PORT
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Navigation
Issued 24 October 2001 Resolved
VSL DID NOT COMPLETE PRE ARRIVAL CHECKS PRIOR TO ENTRY PORT, STATED THEY WERE AT ANCHOR FOR A WEEK, LOG WAS NOT UPDATED SINCE 21 AUG01, UPDATE LOGS AND HAVE CLASS ADDRESS PROBLEM AND SEND REPORT TO MSO JAX PRIOR TO DEPARTURE.
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Accommodation/Occupational Safety
Issued 24 October 2001 Resolved
NO P/W HOSE USED SAME ONE FOR BILGE SYSTEM/FIREFIGHTING. PROVIDE NEW HOSE AND STENCIL FOR P/W ONLY
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Navigation
Issued 24 October 2001 Resolved
VSL HAD NO CURRENT CHARTS OF AOR ONBOARD, MUST PROVIDE NEW UPDATED CHARTS PRIOR TO DEPARTURE
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Documentation
Issued 24 October 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 October 2001
Resolved 2 November 2001
Navigation
Issued 24 October 2001 Resolved
BLOCK DIAGRAM FOR STEERING ON BRIDGE CONSOLE MISSING, MUST PROVIDE COPY OF BLOCK DIAGRAM, PRIOR TO DEPARTURE FROM PORT
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Navigation
Issued 24 October 2001 Resolved
ECHO DEPTH SOUNDER CHART RECORDER NOT WORKING PROPERLY, PROVIDE TECH REPORTON DEPTH SOUNDER PRIOR TO DEPARTURE.
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Navigation
Issued 7 April 1998 Resolved
The block diagram for the emergency steering was not available on the bridge or in the steering flat.
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001
Construction/Loadline
Issued 7 April 1998 Resolved
THE OIL DISCHARGE PLACARD WAS MISSING FROM ENGINE ROOM_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 2001
Resolved 30 October 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.