MAURY USCG vessel records
← All vessels

BEACHWATER II

Built
1975
Last inspected
27 January 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 January 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH9594
403812
Flag
UNITED STATES
Maury page id
psix-403812

Documentation record

Registered dimensions (L × B × D)63.0 ft × 16.0 ft × 8.0 ft
Registered tonnagegross 54 / net 43
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJOE R THORNTON · PENSACOLA, FL, UNITED STATES · built 1975
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBILOXI, MS
Endorsements, as the file codes themcw_un, fi, rec
DocumentationValid · issued 6 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it54 - Simplified, Gross Ton
43 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 27 inspections, each with its date, unit and type; 39 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 27

27 January 2026 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8302118
3 December 2025 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8272407
17 April 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8113435
6 June 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7929107
1 February 2024 Drydock Exam · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7859000
13 November 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7824046
8 June 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7686748
3 February 2023 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7631817
17 January 2023 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7632988
4 June 2022 Type not recorded
No type recorded · USCGC DOLPHIN (WPB 87354) · USCG Heartland District (CGD-H) · Activity 7472464
19 May 2022 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7454852
15 February 2022 Administrative Inspection · Hull Examination · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7396520
6 October 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7328753
1 March 2021 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7148274
1 July 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6992838
17 January 2020 Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6891366
17 September 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814334
27 June 2019 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6727103
21 June 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6427392
10 January 2018 Hull Examination · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6335732
29 September 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6277786
25 July 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6220803
13 June 2017 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6174878
5 May 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5869779
7 March 2016 Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5828178
29 February 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5824566
3 February 2016 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5808642

Deficiency record · 39

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2026 Resolved
Marine inspector shall examine and test the main and auxiliary steering apparatus to the extent necessary to determine that its condition is satisfactory and that it is fit for the service intended. Hydraulic hose on the vessels steering system was found with deterioration on the outside rubber hose. 46 CFR 176.25-35
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2026
Resolved 9 March 2026
Resolution: Vessel owner replaced hose.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 March 2026 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessels Safety Radiotelephony Certificate expires on 04MAR26. Vessel must provide proof of new certificate before departing with passengers beyond 1000 ft. from shore. 46 CFR 184.502
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 March 2026
Resolved 9 March 2026
Resolution: Vessel recieved new Radio Safety Telephony Cert.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2026 Resolved
Batteries shall be effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping a metal object across terminals. Vessels battery for generator did not have a cover and the starting batteries cover was unsecured. 46 CFR 183.05-20
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2026
Resolved 9 March 2026
Resolution: Owner replaced battery box cover and secured all covers for batteries.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 June 2022 Resolved
Vessel must be enrolled in a consortium and be able to provide proof of enrollment as part of a consortium. Vessel did not have proof of enrollment in a random drug testing program.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2022
Resolved 19 June 2022
Resolution: See docs for photos
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 June 2022 Resolved
02 Vessels fuel hoses on both generators are not of an approved type. Vessel must purchase and install approved fuel hoses on both generators.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2022
Resolved 19 June 2022
Resolution: See docs for photos
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 18 March 2021 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Captain's MMC was missing medical certificate.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 24 June 2021
Resolution: Operator provided medical certificate.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 March 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel did not have a complete approved first-aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 24 June 2021
Resolution: Operator provided a complete approved first aid kit.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 18 March 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel did not have a complete approved first-aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 24 June 2021
Resolution: Operator provided an approved first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 March 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Charts on-board were not updated.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 24 June 2021
Resolution: Operator provided up to date navigational charts.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 18 March 2021 Resolved
eck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. The point and uniform loads do not need to be applied simultaneously.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 24 June 2021
Resolution: Operator corrected deficency as so the rails could withstanda point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 March 2021 Resolved
Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Twist on type connectors were made in cabinet in pilot house.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 24 June 2021
Resolution: Operator removed twist type connectors and made connections permanent.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 18 March 2021 Resolved
Drills were not performed due to Captain's concerns with the weather/gusty winds. Drills must be preformed for Coast Guard Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 24 June 2021
Resolution: Fire and man overboard drills were conducted by captain and crew while vessel was underway.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 July 2020 Resolved
Batterys for waterlights (life ring and life float) both had spring terminal type. Replace with screw terminal type battery
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 16 July 2020
Resolution: Recieved pictures, ALL SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 July 2020 Resolved
Battery in wheelhouse had wingnuts on the connectors, provide evidnece of permanent type conenctors.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 2 July 2020
Resolution: Recieved pictures, all sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 July 2019 Resolved
Batteries for floating water lights on the life float and the ring life buoy were expired. Renew batteries for both floating water lights with one of an approved type on the light's label.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 17 July 2019
Resolution: New approved batteries were provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 July 2019 Resolved
All types of life jackets are required to have posted donning instructions. There were 02 types of child size life jackets that did not have posted donning instructions. Post donning instructions for all life jacket types.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 17 July 2019
Resolution: Owner posted new life jacket donning instructions
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 July 2019 Resolved
First aid kit had expired ammonia inhalants and burn gel. Provide new in-date inhalants and burn gel to meet approval under 46 CFR 160.041
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 17 July 2019
Resolution: Owner provided replacement first aid items
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 July 2019 Resolved
Life ring buoy retroflective tape was worn. Renew Type II retroflective tape or provide new life ring buoy approved under 46 CFR 160.050.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 17 July 2019
Resolution: Owner renewed retroflective tape on ring buoy
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 1 July 2019 Resolved
Wiring on the aft generator providing power to fuel and air engine shutdown solenoid was exposed. Replace worn connectors with appropriate crimp style connections so no wires are exposed.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 17 July 2019
Resolution: Owner renewed crimp wire connectors with heat shrink and properly covered wiring with protective tubing
Stability › Weathertight Integrity › General
Issued 30 June 2017 Resolved
Weather tight emergency escape hatch on fwd weather deck needs to have securing device that is operable from both sides. IAW 46 CFR 171.124
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 25 July 2017
Resolution: The emergecny escape hatch has locking hinges installed, where the hatch can be opened/closed from either side and will remain in the closed/open postioned until changed. thsi meets the intent of the regulation.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 29 June 2017 Resolved
Need updated Inland Navigation Rules. IAW 46 CFR 184.420
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 25 July 2017
Resolution: An updated NAV Rules was provided.
Navigation › Piloting/Steering › US Coast Pilot
Issued 29 June 2017 Resolved
Need Coast Pilot. IAW 46 CFR184.420
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 25 July 2017
Resolution: An updated Coast Pilot was provided.
Documentation › Logs/Records › Logbook (official)
Issued 29 June 2017 Resolved
Need to log radio checks. IAW 46 CFR 184.502
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 25 July 2017
Resolution: Radio checks have been conducted and logged into the vessel's log book.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 29 June 2017 Resolved
Need proof of supervisor training for Master and Mate. IAW 46 CFR 16.401
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 25 July 2017
Resolution: Documentation was provided showing recent Supervisory Training, of the Drug & Alcohol Program was completed by the Master and Mate.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 June 2017 Resolved
Need to update Aspirin and burn cream in first aid kit. IAW 46 CFR 184.710
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 25 July 2017
Resolution: Valid asprin and burn cream was provided.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 June 2017 Resolved
Need coursing across top of ladder. IAW 46 CFR 177.900
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 25 July 2017
Resolution: A chain was provided to comlpete the course railing at the top of the ladder on the 01 level.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 June 2017 Resolved
Need to fix ‘T’ cap on station, starboard side, top deck. IAW 46 CFR 177.900
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 25 July 2017
Resolution: the "T" cap on the stantion at the starboard side of hte top deck was satisfactorily repaired.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 June 2017 Resolved
Engine room bilge light needs to be labled. IAW 46 CFR 183.220
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 25 July 2017
Resolution: The engine room bilge light indicator in the pilot house was repaired and is operating satisfactorily.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 June 2017 Resolved
Bilge shower visual indicator needs to correctly operate. IAW 46 CFR 182.530
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 25 July 2017
Resolution: The bilge shower visual indicator at he pilot house was repaired and functions properly.
Engineering › Bilge Water Management System › Piping
Issued 29 June 2017 Resolved
Bilge pump, engine room, starboard side, need to remove PVC and replace with appropriate flexible hose. IAW 46 CFR 182.720
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 28 September 2017
Resolution: Vessel owner replaced bilge piping PVC with flex hosing and added a ovbd COV.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 June 2017 Resolved
Remark life ring buoy. IAW 46 CFR 185.604
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 25 July 2017
Resolution: Re-labeling of the ring buoys were completed satisfactorily.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 4 April 2016 Resolved
Water light for life ring and life float missing battery, needs approved battery.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 5 April 2016
Resolution: Owner replaced both waterlight batteries.
Fire Fighting › Ventilation Systems › Ducts
Issued 4 April 2016 Resolved
Engine room ventilation covers hard to shut, need to make easier to close when fire.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2016
Resolved 4 April 2016
Resolution: Was corrected before we left inspection.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 4 April 2016 Resolved
Inspection tags had wrong year punched out on tag. Had paper work of inspection done but needs proper tag.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2016
Resolved 5 May 2016
Resolution: Updated tags were provided for.
Engineering › Steering Gear System › Hydraulic Hose
Issued 4 April 2016 Resolved
Steering hose in engine room needs replaced w/J1942 or provide paper work to show it complies.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 April 2016
Resolved 5 May 2016
Resolution: Hose was replaced with J1942 type and proper connections.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure Gauge
Issued 4 April 2016 Resolved
Fire extinguisher in engine room needs recharged or replaced, gauge was in red.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2016
Resolved 5 May 2016
Resolution: Extinguisher was re-charged.
Engineering › Bilge Water Management System › Pump
Issued 4 April 2016 Resolved
Bilge high water alarm light did not work on bridge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2016
Resolved 5 April 2016
Resolution: High level alarm indicator operates audibly and visually.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 4 April 2016 Resolved
Second master did not have marine operator permit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 April 2016
Resolved 5 May 2016
Resolution: Marine Operator Permit documentation was provided.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 11 February 2016 Resolved
Flooring in STBD aft accomodation space presented hazard to crew members and passengers. Replace flooring.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 29 February 2016
Resolution: Owner replaced damaged flooring with reinforced plywood.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.