MAURY USCG vessel records Sign in
← All vessels

BEACHWATER II

BEACHWATER II is a 1975 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1994, most recently in January 2026, along with 170 deficiencies, 1 operational control and 1 casualty investigation in 2005.

Records from 1994 to 2026. Most recent: inspection, 27 January 2026.

Built
1975
Last inspected
27 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH9594
403812
Flag
UNITED STATES
367669630
Maury page id
psix-403812

Inspections, by type

…with no type recorded2
Years with a record 30 calendar years (1994–2026)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)63.0 ft × 16.0 ft × 8.0 ft
Registered tonnagegross 54 / net 43
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJOE R THORNTON · PENSACOLA, FL, UNITED STATES · built 1975
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBILOXI, MS
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 21 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it54 - Simplified, Gross Ton
43 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ6309MMSI 367669630 · active · compulsorily equipped · granted 20 November 2025, expires 20 November 2035
WDH9594MMSI 367669630 · expired · compulsorily equipped · granted 30 April 2015, cancelled 7 June 2025
WCQ8817MMSI not assigned · expired · compulsorily equipped · granted 20 April 1995, cancelled 25 June 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 65

27 January 2026 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8302118
3 December 2025 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8272407
17 April 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8113435
6 June 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7929107
1 February 2024 Drydock Exam · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7859000
13 November 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7824046
8 June 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7686748
3 February 2023 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7631817
17 January 2023 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7632988
4 June 2022 Type not recorded
No type recorded · USCGC DOLPHIN (WPB 87354) · USCG Heartland District (CGD-H) · Activity 7472464
19 May 2022 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7454852
15 February 2022 Administrative Inspection · Hull Examination · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7396520
6 October 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7328753
1 March 2021 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7148274
1 July 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6992838
17 January 2020 Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6891366
17 September 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814334
27 June 2019 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6727103
21 June 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6427392
10 January 2018 Hull Examination · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6335732
29 September 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6277786
25 July 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6220803
13 June 2017 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6174878
5 May 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5869779
7 March 2016 Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5828178
29 February 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5824566
3 February 2016 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5808642
28 July 2015 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5198470
10 July 2012 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4367864
9 January 2012 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4221881
24 February 2010 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3677854
17 July 2009 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3526849
13 August 2008 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3295462
15 July 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3253436
12 February 2008 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3143601
18 July 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2999197
11 June 2007 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2927078
20 March 2007 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2891561
23 August 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2758448
17 April 2006 Deficiency Check · Hull Examination · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2626232
19 September 2005 Damage Survey · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2497293
2 June 2005 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2376569
21 May 2005 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2378435
22 March 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2029361
4 February 2004 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1994270
9 May 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1789788
9 April 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1494694
16 January 2002 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1478432
8 May 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1063734
12 April 2001 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1062471
17 August 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1053078
11 July 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1051322
14 February 2000 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1365582
23 August 1999 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1031787
15 June 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1454701
26 May 1998 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1427526
14 August 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 784280
3 July 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1431824
23 August 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1248017
23 July 1996 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1377802
21 March 1996 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1456353
17 January 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 880418
8 June 1995 Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1192126
25 April 1995 Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1183770
18 March 1994 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1192128

Deficiency record · 170

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2026 Resolved
Marine inspector shall examine and test the main and auxiliary steering apparatus to the extent necessary to determine that its condition is satisfactory and that it is fit for the service intended. Hydraulic hose on the vessels steering system was found with deterioration on the outside rubber hose. 46 CFR 176.25-35
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2026
Resolved 9 March 2026
Resolution: Vessel owner replaced hose.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 March 2026 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessels Safety Radiotelephony Certificate expires on 04MAR26. Vessel must provide proof of new certificate before departing with passengers beyond 1000 ft. from shore. 46 CFR 184.502
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 March 2026
Resolved 9 March 2026
Resolution: Vessel recieved new Radio Safety Telephony Cert.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2026 Resolved
Batteries shall be effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping a metal object across terminals. Vessels battery for generator did not have a cover and the starting batteries cover was unsecured. 46 CFR 183.05-20
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2026
Resolved 9 March 2026
Resolution: Owner replaced battery box cover and secured all covers for batteries.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 June 2022 Resolved
Vessel must be enrolled in a consortium and be able to provide proof of enrollment as part of a consortium. Vessel did not have proof of enrollment in a random drug testing program.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2022
Resolved 19 June 2022
Resolution: See docs for photos
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 June 2022 Resolved
02 Vessels fuel hoses on both generators are not of an approved type. Vessel must purchase and install approved fuel hoses on both generators.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2022
Resolved 19 June 2022
Resolution: See docs for photos
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 18 March 2021 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Captain's MMC was missing medical certificate.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 24 June 2021
Resolution: Operator provided medical certificate.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 March 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel did not have a complete approved first-aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 24 June 2021
Resolution: Operator provided a complete approved first aid kit.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 18 March 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel did not have a complete approved first-aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 24 June 2021
Resolution: Operator provided an approved first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 March 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Charts on-board were not updated.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 24 June 2021
Resolution: Operator provided up to date navigational charts.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 18 March 2021 Resolved
eck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. The point and uniform loads do not need to be applied simultaneously.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 24 June 2021
Resolution: Operator corrected deficency as so the rails could withstanda point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 March 2021 Resolved
Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Twist on type connectors were made in cabinet in pilot house.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 24 June 2021
Resolution: Operator removed twist type connectors and made connections permanent.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 18 March 2021 Resolved
Drills were not performed due to Captain's concerns with the weather/gusty winds. Drills must be preformed for Coast Guard Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 24 June 2021
Resolution: Fire and man overboard drills were conducted by captain and crew while vessel was underway.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 July 2020 Resolved
Batterys for waterlights (life ring and life float) both had spring terminal type. Replace with screw terminal type battery
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 16 July 2020
Resolution: Recieved pictures, ALL SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 July 2020 Resolved
Battery in wheelhouse had wingnuts on the connectors, provide evidnece of permanent type conenctors.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 2 July 2020
Resolution: Recieved pictures, all sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 July 2019 Resolved
Batteries for floating water lights on the life float and the ring life buoy were expired. Renew batteries for both floating water lights with one of an approved type on the light's label.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 17 July 2019
Resolution: New approved batteries were provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 July 2019 Resolved
All types of life jackets are required to have posted donning instructions. There were 02 types of child size life jackets that did not have posted donning instructions. Post donning instructions for all life jacket types.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 17 July 2019
Resolution: Owner posted new life jacket donning instructions
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 July 2019 Resolved
First aid kit had expired ammonia inhalants and burn gel. Provide new in-date inhalants and burn gel to meet approval under 46 CFR 160.041
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 17 July 2019
Resolution: Owner provided replacement first aid items
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 July 2019 Resolved
Life ring buoy retroflective tape was worn. Renew Type II retroflective tape or provide new life ring buoy approved under 46 CFR 160.050.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 17 July 2019
Resolution: Owner renewed retroflective tape on ring buoy
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 1 July 2019 Resolved
Wiring on the aft generator providing power to fuel and air engine shutdown solenoid was exposed. Replace worn connectors with appropriate crimp style connections so no wires are exposed.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 17 July 2019
Resolution: Owner renewed crimp wire connectors with heat shrink and properly covered wiring with protective tubing
Stability › Weathertight Integrity › General
Issued 30 June 2017 Resolved
Weather tight emergency escape hatch on fwd weather deck needs to have securing device that is operable from both sides. IAW 46 CFR 171.124
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 25 July 2017
Resolution: The emergecny escape hatch has locking hinges installed, where the hatch can be opened/closed from either side and will remain in the closed/open postioned until changed. thsi meets the intent of the regulation.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 29 June 2017 Resolved
Need updated Inland Navigation Rules. IAW 46 CFR 184.420
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 25 July 2017
Resolution: An updated NAV Rules was provided.
Navigation › Piloting/Steering › US Coast Pilot
Issued 29 June 2017 Resolved
Need Coast Pilot. IAW 46 CFR184.420
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 25 July 2017
Resolution: An updated Coast Pilot was provided.
Documentation › Logs/Records › Logbook (official)
Issued 29 June 2017 Resolved
Need to log radio checks. IAW 46 CFR 184.502
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 25 July 2017
Resolution: Radio checks have been conducted and logged into the vessel's log book.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 29 June 2017 Resolved
Need proof of supervisor training for Master and Mate. IAW 46 CFR 16.401
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 25 July 2017
Resolution: Documentation was provided showing recent Supervisory Training, of the Drug & Alcohol Program was completed by the Master and Mate.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 June 2017 Resolved
Need to update Aspirin and burn cream in first aid kit. IAW 46 CFR 184.710
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 25 July 2017
Resolution: Valid asprin and burn cream was provided.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 June 2017 Resolved
Need coursing across top of ladder. IAW 46 CFR 177.900
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 25 July 2017
Resolution: A chain was provided to comlpete the course railing at the top of the ladder on the 01 level.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 June 2017 Resolved
Need to fix ‘T’ cap on station, starboard side, top deck. IAW 46 CFR 177.900
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 25 July 2017
Resolution: the "T" cap on the stantion at the starboard side of hte top deck was satisfactorily repaired.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 June 2017 Resolved
Engine room bilge light needs to be labled. IAW 46 CFR 183.220
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 25 July 2017
Resolution: The engine room bilge light indicator in the pilot house was repaired and is operating satisfactorily.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 June 2017 Resolved
Bilge shower visual indicator needs to correctly operate. IAW 46 CFR 182.530
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 25 July 2017
Resolution: The bilge shower visual indicator at he pilot house was repaired and functions properly.
Engineering › Bilge Water Management System › Piping
Issued 29 June 2017 Resolved
Bilge pump, engine room, starboard side, need to remove PVC and replace with appropriate flexible hose. IAW 46 CFR 182.720
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 28 September 2017
Resolution: Vessel owner replaced bilge piping PVC with flex hosing and added a ovbd COV.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 June 2017 Resolved
Remark life ring buoy. IAW 46 CFR 185.604
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 25 July 2017
Resolution: Re-labeling of the ring buoys were completed satisfactorily.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 4 April 2016 Resolved
Water light for life ring and life float missing battery, needs approved battery.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 5 April 2016
Resolution: Owner replaced both waterlight batteries.
Fire Fighting › Ventilation Systems › Ducts
Issued 4 April 2016 Resolved
Engine room ventilation covers hard to shut, need to make easier to close when fire.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2016
Resolved 4 April 2016
Resolution: Was corrected before we left inspection.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 4 April 2016 Resolved
Inspection tags had wrong year punched out on tag. Had paper work of inspection done but needs proper tag.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2016
Resolved 5 May 2016
Resolution: Updated tags were provided for.
Engineering › Steering Gear System › Hydraulic Hose
Issued 4 April 2016 Resolved
Steering hose in engine room needs replaced w/J1942 or provide paper work to show it complies.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 April 2016
Resolved 5 May 2016
Resolution: Hose was replaced with J1942 type and proper connections.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure Gauge
Issued 4 April 2016 Resolved
Fire extinguisher in engine room needs recharged or replaced, gauge was in red.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2016
Resolved 5 May 2016
Resolution: Extinguisher was re-charged.
Engineering › Bilge Water Management System › Pump
Issued 4 April 2016 Resolved
Bilge high water alarm light did not work on bridge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2016
Resolved 5 April 2016
Resolution: High level alarm indicator operates audibly and visually.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 4 April 2016 Resolved
Second master did not have marine operator permit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 April 2016
Resolved 5 May 2016
Resolution: Marine Operator Permit documentation was provided.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 11 February 2016 Resolved
Flooring in STBD aft accomodation space presented hazard to crew members and passengers. Replace flooring.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 29 February 2016
Resolution: Owner replaced damaged flooring with reinforced plywood.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 10 July 2012 Resolved
Fire detection systems (smoke detectors) were missing in passenger berthing accommodation spaces per 46 CFR 181.400 (e) and 181.450
Due 10 August 2012
Resolved 2 October 2012
Resolution: Added UL approved smoke detector
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 10 July 2012 Resolved
183.210. Battery charger located in the engine room was found to be without a dripproof covering.
Due 10 August 2012
Resolved 22 August 2012
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 17 July 2009 Resolved
Make repairs to wooden ladder leading into engine room per 46 CFR 176.25-50(a)
Action required: 705 - Other - as specified
Due 17 August 2009
Resolved 18 August 2009
Resolution: The ladder was properly repaired.
Lifesaving › Lifefloat › Painter
Issued 17 July 2009 Resolved
Renew lifefloat lines, grabline, painter, and waterlight line per 46 CFR 180.175.
Action required: 705 - Other - as specified
Due 17 August 2009
Resolved 18 August 2009
Resolution: All required lines were replaced.
Engineering › Generator (propulsion/auxiliary-electric) › Receptacle
Issued 17 July 2009 Resolved
Provide approved plans for new generator installation including all wiring and cables. Plans to be submitted to Marine Safety Center for approval per 46 CFR 176.700 and 177.202(d).
Action required: 705 - Other - as specified
Due 17 August 2009
Resolved 11 September 2009
Resolution: Plans for generator installation were submitted to MSC for approval.
Communications › Alarms/Indicators › High Water Alarm
Issued 17 July 2009 Resolved
Provide and install visual and audible alarm to indicate high water level in accomodation space below deck per 46 CFR 182.530(a).
Action required: 705 - Other - as specified
Due 17 August 2009
Resolved 18 August 2009
Resolution: A bilge high level alarm was properly installed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 July 2009 Resolved
Provide and install a visual indicator of bilge pump operation for berthing space per 46 CFR 182.530 (c).
Action required: 705 - Other - as specified
Due 17 August 2009
Resolved 18 August 2009
Resolution: A visual indicator for the bilge pump in the berthing was properly installed.
Engineering › Generator (propulsion/auxiliary-electric) › Battery Charging Circuitry
Issued 17 July 2009 Resolved
Intall permanent connectors at battery terminals under bridge console per 46 CFR 183.05-20(c).
Action required: 705 - Other - as specified
Due 17 August 2009
Resolved 18 August 2009
Resolution: Permanent terminals were properly installed on the battery underneath the console in the wheel house.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 July 2009 Resolved
Properly install electrical wiring from wash down pump and bait well pump in engine room per 46 CFR 183.10-2(d)
Action required: 705 - Other - as specified
Due 17 August 2009
Resolved 18 August 2009
Resolution: The wiring for the wash down pump were properly installed.
Engineering › Fuel Oil Service System › Valve
Issued 17 July 2009 Resolved
Provide and install fuel shut off valves at engine for both main engines and generator per 46 CFR 182.20-40(b)(3)
Action required: 705 - Other - as specified
Due 17 August 2009
Resolved 18 August 2009
Resolution: Fuel shut off valves were installed at the engines in the engine rooms.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 17 July 2009 Resolved
Make emergency broadcast placard vessel specific per 46 CFR 184.506.
Action required: 705 - Other - as specified
Due 17 August 2009
Resolved 18 August 2009
Resolution: The emergency broadcast placard was made specific to the vessel.
Fire Fighting › Combustible Materials › Insulation
Issued 15 July 2008 Resolved
Secure all areas of open insulation in engine room.
Due 15 August 2008
Resolved 13 August 2008
Resolution: Areas secured.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 15 July 2008 Resolved
Properly mount oil pressure gauge on port main engine.
Due 15 August 2008
Resolved 13 August 2008
Resolution: Oil Pressure gauge removed.
Electrical › Electric Generation Source (service) › Generator
Issued 15 July 2008 Resolved
Clean generator windings on ship service generator.
Due 15 August 2008
Resolved 13 August 2008
Resolution: Windings cleaned.
Engineering › Fuel Oil Service System › Piping
Issued 15 July 2008 Resolved
Replace lube oil lines to lube oil filters due to deterioration.
Due 15 August 2008
Resolved 13 August 2008
Resolution: Lines replaced.
Engineering › Freshwater Generation System › Heating Tube
Issued 15 July 2008 Resolved
Make repairs to soft patch on hot water heater piping.
Due 15 August 2008
Resolved 13 August 2008
Resolution: Line with soft patch removed and new line added.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 July 2008 Resolved
Properly mount guards on ship service generators.
Due 15 August 2008
Resolved 13 August 2008
Resolution: Guards mounted.
Engineering › Steering Gear System › Bracket/Clamp
Issued 15 July 2008 Resolved
Provide and install carter pin in steering ram clevis.
Due 15 August 2008
Resolved 13 August 2008
Resolution: Carter pin added.
Fire Fighting › Combustible Materials › Insulation
Issued 15 July 2008 Resolved
Secure exhaust lagging on ship service generator.
Due 15 August 2008
Resolved 13 August 2008
Resolution: Lagging secured.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 July 2008 Resolved
Make repairs and prove operation of light fixture over ship service generator.
Due 15 August 2008
Resolved 13 August 2008
Resolution: Light fixture replaced and operates satisfactorily.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 12 February 2008 Resolved
Make prop and shaft ready for inspection. Prop was removed for repairs.
Action required: 705 - Other - as specified
Resolved 22 February 2008
Resolution: Inspected both prop and shaft satisfactorily.
Construction/Loadline › Hull › Bottom Plating
Issued 12 February 2008 Resolved
Repair blister on starboard bow below the waterline approximately 1 ft from keel.
Action required: 705 - Other - as specified
Resolved 22 February 2008
Resolution: Blister repaired.
Engineering › Steering Gear System › Rudder
Issued 12 February 2008 Resolved
Make starboard rudder ready for inspection. It was removed for repairs.
Action required: 705 - Other - as specified
Resolved 22 February 2008
Resolution: Starboard rudder was replaced and inspected sat.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 12 February 2008 Resolved
Replace starboard cutlass bearing.
Action required: 705 - Other - as specified
Resolved 22 February 2008
Resolution: Cutlass bearing was replaced.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 11 June 2007 Resolved
Provide a separate training log, bridge log, and lifesaving maintenance record in accordance with 46 CFR 185.702 and 185.520.
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 18 July 2007
Resolution: Provided separate logs.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 June 2007 Resolved
Provide a Coast Guard approved first aid kit in accordance with 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 18 July 2007
Resolution: Provided approved first aid kit.
Lifesaving › Lifebuoys › Serviceable
Issued 11 June 2007 Resolved
Replace the retroreflective tape on the ring lifebuoy in accordance with 46 CFR 185.604(i).
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 18 July 2007
Resolution: Replaced the tape.
Fire Fighting › Fire Bucket › Quantity
Issued 11 June 2007 Resolved
Provide three 2.5 gallon fire buckets in accordance with 46 CFR 181.610.
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 18 July 2007
Resolution: Provided 3 fire buckets.
Navigation › Collision/Grounding Avoidance › Radar
Issued 11 June 2007 Resolved
Provide a radar in accordance with 46 CFR 184.404.
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 18 July 2007
Resolution: Installed a radar.
Electrical › Electrical Distribution System (service) › Switch
Issued 11 June 2007 Resolved
Provide battery disconnect switches for the three starting batteries for both main engines and the generator in accordance with 46 CFR 183.380.
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 18 July 2007
Resolution: Installed all 3 battery disconnect switches.
Lifesaving › Lifefloat › Markings
Issued 11 June 2007 Resolved
Properly stencil the lifejackets with the vessel's name in accordance with 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 18 July 2007
Resolution: Properly stenciled lifejackets.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 11 June 2007 Resolved
Provide and install a latch on the oven door in accordance with 46 CFR 184.220.
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 18 July 2007
Resolution: Installed oven door latch.
Lifesaving › Lifefloat › Paddle
Issued 11 June 2007 Resolved
Properly stencil the lifefloat paddles with the vessel's name in accordance with 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 18 July 2007
Resolution: Properly stenciled paddles.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 June 2007 Resolved
Make the opening in the rails consistent with the deck rails in accordance with 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 18 July 2007
Resolution: Added lower chain to make chain rails consistent with deck rails.
Electrical › Electric Generation Source (service) › Panelboard
Issued 11 June 2007 Resolved
Properly mount the electrical terminal box on the generator in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 18 July 2007
Resolution: Properly mounted the electrical terminal box.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 11 June 2007 Resolved
Provide a catch basin for the blow-by so oil does not enter the bilge in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 18 July 2007
Resolution: Connected blow-by to a bucket via copper tubing.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 11 June 2007 Resolved
Provide a plug for all lube oil drains in the engine room in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 18 July 2007
Resolution: Plugged all lube oil drains.
Operations/Management › Drills/Instruction › Fire
Issued 11 June 2007 Resolved
Provide emergency instructions in the event of a fire in accordance with 46 CFR 185.510.
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 11 June 2007
Resolution: Provided emergency instructions in the event of a fire.
Lifesaving › Lifefloat › Float-free Link
Issued 11 June 2007 Resolved
Prove the weak link is approved for the life floatin way of providing the tag in accordance with 46 CFR 180.137.
Action required: 705 - Other - as specified
Due 11 June 2007
Resolved 11 June 2007
Resolution: Provided the tag for the weak link.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 23 August 2006 Resolved
Provide an approved time delay for the fixed fire fighting system in accordance with 46 CFR 181.410.
Action required: 705 - Other - as specified
Due 30 August 2006
Resolved 13 November 2006
Resolution: Provided an approved time delay for the fixed fire fighting system
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 23 August 2006 Resolved
Prove operation automatic shutdown of generator upon activation of the fixed fire suppression system in accordance with 46 CFR 181.410.
Action required: 705 - Other - as specified
Due 30 August 2006
Resolved 13 November 2006
Resolution: Proved operation of the automatic shutdown of the generator
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 17 April 2006 Resolved
Have the fixed CO2 extinguishing system for the engine room properly serviced in the presence of a Coast Guard Marine inspector.
Due 13 November 2006
Resolved 13 November 2006
Resolution: Had the fixed CO2 extinguishing system properly serviced
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 17 April 2006 Resolved
Provide a current training log with the required entries in accordance with 46 CFR 185.420.
Due 17 May 2006
Resolved 30 May 2006
Resolution: A training record was place onboard the vessel.
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 17 April 2006 Resolved
Provide a lifesaving equipment maintenance record in accordance with 46 CFR 185.702
Due 17 May 2006
Resolved 30 May 2006
Resolution: A lifesaving equipment maintenance record was place onboard.
Documentation › Logs/Records › Logbook (official)
Issued 17 April 2006 Resolved
Provide a bridge log with the required entries.
Due 17 May 2006
Resolved 30 May 2006
Resolution: A bridge log was placed onboard.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 17 April 2006 Resolved
Provide and post an emergency broadcast placard. in accordance with 46 CFR 184.506
Due 17 May 2006
Resolved 30 May 2006
Resolution: The emergency broadcast placard was posted.
Electrical › Electrical Distribution System (service) › Cable
Issued 17 April 2006 Resolved
Properly support the electrical wires in the passage way down below decks.
Due 17 May 2006
Resolved 30 May 2006
Resolution: Properly supported the electrical wires in the passageway down below decks.
Navigation › Piloting/Steering › US Coast Pilot
Issued 17 April 2006 Resolved
Provide a coast pilot and a coast guard light list in accordance with 46 CFR 184.420.
Due 17 May 2006
Resolved 30 May 2006
Resolution: A coast pilot and a light list was placed onboard.
Construction/Loadline › Penetrations › Bottom Plug
Issued 17 April 2006 Resolved
Remove the plastic plug in the through hull fitting just aft of the port main engine and replace with a metal plug.
Due 17 May 2006
Resolved 30 May 2006
Resolution: The plastic plug was replaced with a metal plug.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 17 April 2006 Resolved
Double nut both the port and starboard shaft packing glands.
Due 17 May 2006
Resolved 30 May 2006
Resolution: Both packing glands were double nutted.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 17 April 2006 Resolved
Provide and install pipe caps or plugs in the port and starboard main engine oil drains.
Due 17 May 2006
Resolved 30 May 2006
Resolution: Plugs were install in the oil drains.
Operations/Management › Drills/Instruction › Fire
Issued 17 April 2006 Resolved
Conduct drills in the presence of a Coast Guard inspector.
Due 17 May 2006
Resolved 30 May 2006
Resolution: Drills were completed.
Stability › Watertight Integrity › General
Issued 17 April 2006 Resolved
Prove water tight integrity of the collision bulkhead.
Due 17 May 2006
Resolved 30 May 2006
Resolution: Repairs were made to the bulkhead and satisfactory test was conduct.
Engineering › Sea-water System (primary cooling) › Valve
Issued 16 February 2006 Resolved
Replace gate valve and seat on Port side through hull fitting, MSD discharge side.
Action required: 705 - Other - as specified
Due 16 March 2006
Resolved 17 April 2006
Resolution: A new valve was installed in the sewage line.
Stability › Watertight Integrity › General
Issued 31 January 2006 Resolved
Prove water tight integrity of collision bulkhead with hydrostatic test due to removal of areas of bulkhead during fiberglass repair of hull
Action required: 705 - Other - as specified
Due 16 March 2006
Resolved 30 May 2006
Resolution: The forward peak was fill to the top with water to prove the repairs made to the collision bulkhead were good. The entire area of the bulkhead was visually examined and no leaks were found. The test is satisfactory.
Construction/Loadline › Penetrations › Valve Flange
Issued 31 January 2006 Resolved
Make through hull fittings ready for inspection.
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 16 February 2006
Resolution: Made through hull fittings ready for inspection.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 2 June 2005 Resolved
Provide valid CPR cards for 50% of crew as required by NVIC 1-91
Action required: 705 - Other - as specified
Due 5 July 2005
Resolved 30 June 2005
Resolution: Valid CPR card provided
Communications › Radio Communications › EPIRB
Issued 2 June 2005 Resolved
Relocate EPIRB to provide a float free arrangement as required by 46 CFR 180.64
Action required: 705 - Other - as specified
Due 2 July 2005
Resolved 30 June 2005
Resolution: EPIRB relocated
Construction/Loadline › Structures › Scuttle
Issued 2 June 2005 Resolved
Attach lanyard to forward compartment hatch as required by 46 CFR 171.124
Action required: 705 - Other - as specified
Due 2 July 2005
Resolved 30 June 2005
Resolution: Chain attached to hatch cover
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 June 2005 Resolved
Provide operable battery for starboard engine in accordance with 46 CFR 176.806
Action required: 705 - Other - as specified
Due 2 July 2005
Resolved 30 June 2005
Resolution: New battery properly installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 March 2004 Resolved
Provide corrosion ressistant clip connecting the waterlight to the life buoy IAW 46CFR180.70
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 June 2004
Resolved 12 May 2004
Resolution: Vessel provided clip on the spot
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 March 2004 Resolved
Provide emergency lighting IAW 46CFR183.432.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 June 2004
Resolved 12 May 2004
Resolution: Vessel installed emergency lighting prior to leaving vessel.
Personnel › Manning/Qualifications
Issued 9 May 2003 Resolved
Provide current CPR/First aid cards for 50% of crew as per NVIC 1-91. LEGACY COMPONENT DESC: First Aid Certified Personnel
Due 9 June 2003
Resolved 3 July 2003
Navigation › Piloting/Steering
Issued 9 May 2003 Resolved
Provide missing tidal current tables & USCG Light List as per 46 CFR 184.420. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Due 9 June 2003
Resolved 3 July 2003
Deck/Cargo › Fishing
Issued 9 May 2003 Resolved
Replace 4 deteriorated hydraulic hoses on boat davits (2 starboard, 2 port) as per 46 CFR 182.410. LEGACY COMPONENT DESC: Skiff davits
Due 9 June 2003
Resolved 3 July 2003
Lifesaving › Lifejacket/PFD (Type III)
Issued 9 May 2003 Resolved
Replace 3 (Foam Type) deteriorated PFDs in aft skiff as per 46 CFR 180.71. LEGACY COMPONENT DESC: Condition
Due 9 June 2003
Resolved 3 July 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 9 May 2003 Resolved
Replace expired eye wash and asprin in first aid kit as per 46 CFR 184.710. LEGACY COMPONENT DESC: Medicine Chest
Due 9 June 2003
Resolved 3 July 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 9 May 2003 Resolved
Provide annual servicing report for CO2 system as per 46 CFR176.810 LEGACY COMPONENT DESC: Service Report
Due 9 June 2003
Resolved 3 July 2003
Lifesaving › Hand Flares › Quantity
Issued 9 May 2003 Resolved
Provide 1 red flare as per 46 CFR 180.68.
Due 9 May 2003
Resolved 9 May 2003
Resolution: Replaced during inspection.
Lifesaving › Buoyant Apparatus
Issued 9 May 2003 Resolved
Replace lifeline on lifefloat as per 46 CFR 180.175. LEGACY COMPONENT DESC: Life line
Due 9 May 2003
Resolved 9 May 2003
Resolution: Replaced during inspection.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 9 April 2002 Resolved
Work list item repair Saltwater leak on outboard side of MDE.
Due 9 May 2002
Resolved 15 April 2002
Resolution: Leak repaired by replacing pipe plug in manifold.
Engineering › Shafting/Propeller Arrangements
Issued 9 April 2002 Resolved
Work list item 002-Tighten packing glands to reduce water flow. LEGACY COMPONENT DESC: Stern Tube
Due 9 May 2002
Resolved 15 April 2002
Resolution: Tightened packing glands.
Electrical › Lighting (service)
Issued 9 April 2002 Resolved
Work list item-Provide globe for light in E/R stbd side overhead.
Due 9 May 2002
Resolved 15 April 2002
Resolution: Globe installed on light in engine room.
Electrical › Electric Generation Source (service)
Issued 9 April 2002 Resolved
Work list item-Tape negative ground wire on generator and support to prevent chafing on frame. LEGACY COMPONENT DESC: Conductor
Due 9 May 2002
Resolved 15 April 2002
Resolution: Cable properly insulated and supported.
Engineering › Fuel Oil Service System
Issued 9 April 2002 Resolved
Work list item-tighten stbd F/O tank rtn line fittings to prevent leakage. LEGACY COMPONENT DESC: Piping
Due 9 May 2002
Resolved 15 April 2002
Resolution: Fitting tightened eliminating leaks.
Accommodation/Occupational Safety › Occupational Safety
Issued 9 April 2002 Resolved
Work list item-Provide chain at top of ladder going to upper deck forward. LEGACY COMPONENT DESC: Deck Rail
Due 15 April 2002
Resolved 15 April 2002
Resolution: Installed chain at top of ladder.
Electrical › Electrical Distribution System (service)
Issued 9 April 2002 Resolved
Work list item- Provide proper cover for junction box in fore peak. LEGACY COMPONENT DESC: Junction Box
Condition: Improper Installation
Due 9 May 2002
Resolved 15 April 2002
Resolution: Provided proper cover for electrical box.
Engineering › Bilge Water Management System
Issued 9 April 2002 Resolved
Work list item-Double clamp bilge line in forepeak. LEGACY COMPONENT DESC: Hose
Due 9 May 2002
Resolved 15 April 2002
Resolution: Installed clamps.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 9 April 2002 Resolved
Work list Item- Have CO2 bottle in e/r serviced.
Condition: Improper/Lack of Maintenance
Due 9 May 2002
Resolved 15 April 2002
Resolution: Had engine room CO2 serviced.
Navigation › Piloting/Steering
Issued 9 April 2002 Resolved
Work list item update navigation publications. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Due 9 May 2002
Resolved 15 April 2002
Resolution: Provided updated navigation publications.
Documentation › Certificates/Documents
Issued 9 April 2002 Resolved
Work list item-Provide current certificate of documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Due 9 May 2002
Resolved 15 April 2002
Resolution: Provided certificate of documentation.
Operations/Management › Drills/Instruction
Issued 9 April 2002 Resolved
Work list item-Provide crewmembers so drills can be performed.
Due 9 May 2002
Resolved 15 April 2002
Resolution: Performed drills with capt and crew.
Lifesaving
Issued 12 April 2001 Resolved
PROVIDE PROPER LIFELINE AND WATERLIGHT LANYARD AS REQUIRED BY 46 CFR 180.70CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 12 May 2001
Resolved 14 May 2001
Documentation
Issued 12 April 2001 Resolved
PROVIDE PROPER FCC DOCUMENTATION ( SAFETY RADIO TELEPHONE CERTIFICATE) AS REQUIRED BY 47 CFR 80.903
Condition: Unknown
Due 12 May 2001
Resolved 14 May 2001
Electrical
Issued 12 April 2001 Resolved
PROVIDE PROPER WIRING FOR ENGINE EXHAUST FAN AS REQUIRED BY 46 CFR 183.10- 20/340(P)
Condition: Unknown
Due 12 May 2001
Resolved 14 May 2001
Navigation
Issued 12 April 2001 Resolved
PROVIDE UPDATED CHARTS AND PUBLICATIONS AS REQUIRED BY 46 CFR 184.420
Condition: Unknown
Due 12 May 2001
Resolved 14 May 2001
Construction/Loadline
Issued 12 April 2001 Resolved
PROVIDE VISUAL INDICATOR FOR HIGH LEVEL BILGE ALARM AT OPERATING STATION ASREQUIRED BY 46 CFR 182.530
Condition: Unknown
Due 12 May 2001
Resolved 14 May 2001
Construction/Loadline
Issued 12 April 2001 Resolved
PROVIDE PROPER REINFORCED HOSE FOR FORWARD BILGE PUMP AS REQUIRED BY 46 CFR176.804(I)
Condition: Unknown
Due 12 May 2001
Resolved 14 May 2001
Lifesaving
Issued 12 April 2001 Resolved
PROVIDE P.A. SYSTEM AS REQUIRED BY 46 CFR 184.610
Condition: Unknown
Due 12 May 2001
Resolved 14 May 2001
Accommodation/Occupational Safety
Issued 12 April 2001 Resolved
PROVIDE RAIL COURSES ON BOW PULPIT AS REQUIRED BY 46 CFR 177.900
Condition: Unknown
Due 12 May 2001
Resolved 14 May 2001
Engineering
Issued 11 July 2000 Resolved
PROVIDE SUPPORT BRACKETS FOR EXHAUST HOSE ON MAIN ENGINES AS REQUIRED BY 46CFR 182.425
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Lifesaving
Issued 11 July 2000 Resolved
RENEW EXPIRED FLARES IN SKIFFS AS REQUIRED BY 46 CFR 180.68
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Engineering
Issued 11 July 2000 Resolved
INSTALL MACHINERY GUARD ON S/S GENERATOR AS REQUIRED BY 46 CFR 177.960
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Lifesaving
Issued 11 July 2000 Resolved
RENEW RETRO REFLECTIVE TAPE ON LIFEJACKETS IN SKIFF AS REQUIRED BY 46 CFR 185.604(H)
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Electrical
Issued 11 July 2000 Resolved
PROVIDE PROPER COVER ON ELECTRICAL JUNCTION BOX IN FORWARD LAZERTTE AS REQUIRED BY 46 CFR 186.354
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Electrical
Issued 15 June 1999 Resolved
Provide proper wiring for washdown pump located in engine room in accordance with 46 CFR 183,10-20.
Condition: Unknown
Due 15 July 1999
Resolved 24 August 1999
Lifesaving
Issued 15 June 1999 Resolved
provide hydrostatic release for epirb as required by 46 CFR 180.64.
Condition: Unknown
Due 15 July 1999
Resolved 24 August 1999
Construction/Loadline
Issued 15 June 1999 Resolved
Provide and install lanyard on forepeak hatchcover as required by 46 CFR 179.30.
Condition: Unknown
Due 15 July 1999
Resolved 24 August 1999
Engineering
Issued 15 June 1999 Resolved
Provide and install exhaust lagging on both MDEs and S/S generator.
Condition: Unknown
Due 15 July 1999
Resolved 24 August 1999
Fire Fighting
Issued 3 July 1997 Resolved
Conduct in the presence of a Coast Guard Marine Inspector a satisfactory fire, man overboard, and abandon vessel drill IAW 46 CFR 176.808(G).
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Lifesaving
Issued 3 July 1997 Resolved
Properly mark PFD storage IAW 46 CFR 185.604(F).
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Lifesaving
Issued 3 July 1997 Resolved
Properly attatch lifefloat waterlight to the lifefloat with 18 foot of darkline IAW 46 CFR 180.137.
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Construction/Loadline
Issued 3 July 1997 Resolved
Properly repair fractured transom on skiff MI 320AP. IAW Coast Guard NVIC 8/87.
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Documentation
Issued 3 July 1997 Resolved
Provide documentation that the deckhand is enrolled in a random drug testing program IAW 46 CFR 16.230.
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Documentation
Issued 3 July 1997 Resolved
Provide a valid FCC operators license IAW 47 CFR 80.155
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Lifesaving
Issued 3 July 1997 Resolved
Properly attach waterlight to the ringbuoy with 3 foot lanyard and corrosion resistant clip IAW 46 CFR 180.70(d)
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Lifesaving
Issued 3 July 1997 Resolved
Provide and properly post emergency check off list IAW 46 CFR 185.510
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Navigation
Issued 3 July 1997 Resolved
Provide and properly post an Emergency Broadcast Placard IAW 46 CFR 185.506
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Lifesaving
Issued 3 July 1997 Resolved
Provide 3 each valid red night flares and 3 each valid orange day smokes IAW 46 CFR 180.68.
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Documentation
Issued 3 July 1997 Resolved
Provide documentation that 50% of deckhands have valid Red Cross CPR and First Aid training IAW COAST GUARD NVIC 1-91.
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Lifesaving
Issued 3 July 1997 Resolved
Provide 13 each Coast Guard approved type I adult PFD's on board the vesselproperly marked IAW 46 CFR 180.71(A) and 185.604(B).
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Accommodation/Occupational Safety
Issued 3 July 1997 Resolved
Provide and properly install sea rails on galley stove IAW 46 CFR 184.220(E).
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Navigation
Issued 3 July 1997 Resolved
Provide valid publications IAW 46 CFR 184.420.
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Navigation
Issued 3 July 1997 Resolved
Provide a proper size bell (7.9" OR 200MM) IAW 72 COLREGS ANNEX III 2(B).
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Documentation
Issued 3 July 1997 Resolved
Provide valid state registration for all skiffs IAW 33 CFR 173.15
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Engineering
Issued 3 July 1997 Resolved
Properly ground fuel fill hose on both fuel tanks IAW 46 CFR 182.20-30(D).
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Engineering
Issued 3 July 1997 Resolved
Provide and properly install fuel shut off valves at the engine end of the fuel supply line IAW 46 CFR 182.20-40(b)(3)
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Engineering
Issued 3 July 1997 Resolved
Remove petcocks from generator prime mover fuel filters IAW 46 CFR 182.20- 40(A)(4).
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Electrical
Issued 3 July 1997 Resolved
Provide a main breaker to protect the sevice generator IAW 46 CFR 183.10- 35(C).
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Electrical
Issued 3 July 1997 Resolved
Derate 40 degree celsius ambient service generator to 80% of the full load rating IAW 46 CFR 183.10-5(F)(2). Provide and attatch derating placard IAW46 CFR 183.10-5(F)(2).
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Electrical
Issued 3 July 1997 Resolved
Properly mount general lighting (FLASHLIGHTS), one in the pilot house and one at the access to the engine room IAW 46 CFR 183.430.
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Electrical
Issued 3 July 1997 Resolved
Renew missing lighting fixture globes in the accomadation spaces IAW 46 CFR183.01-5.
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Lifesaving
Issued 3 July 1997 Resolved
Provide and properly post a Coast Guard approved first aid kit IAW 46 CFR 184.710 or provide all materials listed IAW 46 CFR 160.041.
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Engineering
Issued 3 July 1997 Resolved
Properly repair leak on port main engine sea water pump IAW 46 CFR 176.804
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Construction/Loadline
Issued 3 July 1997 Resolved
Provide and properly install a (6) inch coaming on the aft main deck weather tight door IAW 46 CFR 171.124.
Condition: Unknown
Due 22 March 1998
Resolved 20 August 1997
Navigation
Issued 23 July 1996 Resolved
REPLACE AND INSTALL NEW NAV. LIGHT BULB ON THE STBD. NAV. LIGHT.
Condition: Unknown
Due 23 August 1996
Resolved 23 August 1996
Unknown
Issued 23 July 1996 Resolved
REMOVE ALL PUSH FUEL HOSES AND THE FITTINGS.INSTALL NEW FUEL HOSES AND FITTINGS APPROVED ASTM 1692 STANDARD. 46CFR182.20-40 (ii)
Condition: Unknown
Due 23 August 1996
Resolved 23 August 1996
Unknown
Issued 23 July 1996 Resolved
INSTALL PULLEY GUARDS ON GEN. 46CFG177.35-15
Condition: Unknown
Due 23 August 1996
Resolved 23 August 1996
Fire Fighting
Issued 23 July 1996 Resolved
MOUNT PORTABLE FIRE EXT. IN LIVING SPACE. 46CFR181.30-10(B)
Condition: Unknown
Due 23 August 1996
Resolved 23 August 1996
Electrical
Issued 8 June 1995 Resolved
PROVIDE PROTECTIVE GLOBES FOR ALL THREE ENGINE ROOM HOV OVERHEAD LIGHTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 June 1995
Resolved 8 June 1995
Documentation
Issued 8 June 1995 Resolved
PROVDIE FCC SAFETY CERTIFICATE
Condition: Unknown
Due 8 June 1995
Resolved 8 June 1995

Casualty record · 1

21 May 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2378435
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.