MAURY USCG vessel records Sign in
← All vessels

NORDPOLEN

NORDPOLEN is a 1993 tank ship. The Coast Guard has recorded 32 inspections since 1994, most recently in March 2009, along with 25 deficiencies and 5 operational controls.

Records from 1994 to 2009. Most recent: inspection, 16 March 2009.

Built
1993
Last inspected
16 March 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8705618 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
403821
Flag
MALTA
—
Maury page id
psix-403821

Inspections, by type

…with no type recorded20
Years with a record 14 calendar years (1994–2009)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11636 - Convention (Subpart B), Net Ton
18094 - Convention (Subpart B), Gross Ton
29027 - Dead Weight, Ton
38213 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

16 March 2009 Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3434308
15 February 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3418164
2 November 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3355715
1 November 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3357132
31 October 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3355272
17 January 2006 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2567820
11 January 2006 COC-TVE Renew · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex II Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2564774
18 September 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2496428
23 April 2005 Ballast Water Examination · COC-TVE Annual
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2341181
31 October 2004 ISPS II Exam
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2231044
20 November 2003 Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1950979
30 August 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1891882
4 June 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1809600
28 May 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1808059
20 January 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1732746
19 January 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1732512
12 December 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1717964
9 December 2002 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1716530
9 November 2001 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 295212
10 August 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 539239
4 November 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 434402
4 November 1999 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 804358
9 October 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 408457
9 October 1997 Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 773673
19 January 1996 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 451634
28 December 1995 Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 386404
27 November 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 385298
9 August 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 472616
2 February 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 689752
21 November 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 497269
19 November 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 451030
19 November 1994 Tank Vessel Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1464557

Deficiency record · 25

Construction/Loadline › Structures › Door
Issued 2 November 2008 Resolved
Stbd focsle door, when closed, shows light penetration. Gasket and steel are wasted compromising weathertightness. ICLL 66 Annex I/12 (1)
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 December 2008
Resolved 23 January 2009
Resolution: Received class report clearing def.
Electrical › Lighting (service) › Ground Detection
Issued 2 November 2008 Resolved
Numerous lighting fixtures in cargo pump room are missing electrical bonding straps and protective globes; potential of hazardous vapors and flammability hazard. SOLAS 2004 II-1/45.10 IBC 10
Action required: 705 - Other - as specified
Due 2 December 2008
Resolved 23 January 2009
Resolution: Received class report clearing def.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 2 November 2008 Resolved
Several cargo samples do not have labels identifying what cargo is in the container. To ensure cargo compatibility, samples must be labeled. SOLAS 2004 VII/10 (1) IBC 16.5.3
Action required: 705 - Other - as specified
Due 2 December 2008
Resolved 23 January 2009
Resolution: Received class report clearing def.
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 2 November 2008 Resolved
high oxygen content alarm and low water to scrubber alarms did not provide audio and visual alarms. Prove proper operation of IGS and all associated alarms prior to carrying cargo requiring inertion. FSS Code 15
Action required: 705 - Other - as specified
Due 2 December 2008
Resolved 23 January 2009
Resolution: Received class report clearing def.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 11 January 2006 Resolved
4 of the life jackets in engineroom had dead batteries.
Due 11 January 2006
Resolved 11 January 2006
Resolution: Corrected on the spot
Deck/Cargo › Inert Gas System › IGS Blower
Issued 11 January 2006 Resolved
Prove proper operation of IGS blower motor(newly installer) prior to cargo operations to the satisfaction of the class society surveyor.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2006
Resolution: Recieved faxed class report #MM10640010 from Lloyds Register clearing the same.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 11 January 2006 Resolved
Prove proper operation of Vessel IGS O2 analyzer unit(reliable). Crew was unable to provide test to USCG inspector. Prior to cargo operations to satisfaction of vessels classification society.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2006
Lifesaving › Lifeboat › Propulsion Starting System
Issued 11 January 2006 Resolved
prove proper operation of port and stbd lifeboats (engine test). Port would not start after second attempt. Stbd would not start.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2006
Deck/Cargo › Vapor Control Systems › Vapor Recovery Unit
Issued 11 January 2006 Resolved
Provide class letter approving vessels vapor recovery system fully meets 46CFR Part 39 regulations. Prior to use of vapor recovery system.
Condition: Placed in Improper Service
Due 11 January 2006
Resolved 15 January 2006
Lifesaving › Launching Appliances › Winch Brake
Issued 23 April 2005 Resolved
PORT lifeboat gravity brake failed to stop boat during launch; PORT lifeboats's remote launching release wire came loose from lifeboat during launch.
Condition: Unknown
Due 23 April 2005
Resolved 24 April 2005
Resolution: Class faxed report to CG attesting to satisfactory repairs to gravity brake & remote launching release mechanism.
Engineering › Steering Gear System
Issued 20 November 2003 Resolved
Vessels #1 steering gear pump was inop. LEGACY COMPONENT DESC: Pump
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2003
Resolution: Vessel provide class report of #1 pump working properly
Deck/Cargo › Cargo Stowage › General
Issued 20 November 2003 Resolved
Vessel to restow all compress air bottles in a proper storage area or rack
Due 30 December 2003
Resolved 23 April 2005
Resolution: All compress air bottles are properly stored.
Deck/Cargo › Inert Gas System
Issued 4 June 2003 Resolved
Two Gasoline cargo tanks tested for 02% percentage. Both tanks were in the 20% range. Two different meters were used by the crew Chief Engineer of vessel.
Action required: 705 - Other - as specified
Resolved 4 June 2003
Resolution: Vessel''s rcvd COTP for this condition prior to entry. Vsl received a COTP recsission
Lifesaving › Lifeboat
Issued 9 December 2002 Resolved
prove proper operation of simultaneous release mechanism of port lifeboat.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 December 2002
Resolved 9 December 2002
Resolution: Examination of vessel''''''''s repairs were completed and found satisfactory, lifeboat release was not performed due to high winds. Class to provide acceptance of repairs.
Lifesaving › Lifeboat
Issued 9 December 2002 Resolved
Prove proper operation of simultaneous release mechanism of starboard lifeboat.
Action required: 705 - Other - as specified
Due 10 December 2002
Resolved 11 December 2002
Communications › Radio Communications
Issued 9 December 2002 Resolved
provide current hydrostatic release for EPIRB. LEGACY COMPONENT DESC: EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Due 9 December 2002
Resolved 9 December 2002
Navigation
Issued 9 November 2001 Resolved
Vessel's ARPA and Port radar were inoperative.
Condition: Unknown
Due 10 November 2001
Resolved 3 December 2001
Deck/Cargo
Issued 4 November 1999 Resolved
Required to make adjustments to the #6 center tank hatch.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Lifesaving
Issued 4 November 1999 Resolved
Required to replace two portable oxygen monitors.
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Fire Fighting
Issued 9 October 1997 Resolved
PROVIDE FIRE HOSES, NOZZLES, AND SPANNER WRENCHES FOR ALL FIRE STATIONS IN ACCORDANCE WITH SOLAS 74 II-2/4.7
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Navigation
Issued 9 October 1997 Resolved
PROVE COMPLETION OF MANEUVERING PERFORMANCE TESTS IN ACCORDANCE WITH 33CFR157.445.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Fire Fighting
Issued 9 October 1997 Resolved
PROVE PROPER OPERATION OF ALL FIRE SCREEN DOORS IN ACORDANCE WITH SOLAS 74 II-2/47.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Lifesaving
Issued 9 October 1997 Resolved
PROVE PROPER OPERATION OF LIFEBOAT DAVIT LIMIT SWITCH IN ACCORDANCE WITH SOLAS 74III/48.2.5.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Construction/Loadline
Issued 9 October 1997 Resolved
PROVE PROPER OPERATION OF ALL WATER TIGHT DOORS IN MAIN AND SECOND DECKS_x001C_ IN ACCORDANCE WITH ICLL 66 ANNEX 1/12.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Navigation
Issued 9 October 1997 Resolved
PROVIDE AN AUTOPILOT OVERRIDE DEVICE OR ALARM IN ACCORDANCE WITH 33CFR157.440.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999