MAURY USCG vessel records Sign in
← All vessels

PACIFIC ENDEAVOR

PACIFIC ENDEAVOR is a 1992 freight ship. The Coast Guard has recorded 13 inspections since 1999, most recently in June 2024, along with 3 deficiencies and 1 operational control.

Records from 1999 to 2024. Most recent: inspection, 28 June 2024.

Built
1992
Last inspected
28 June 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9040352 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
404049
Flag
LIBERIA
—
Maury page id
psix-404049

Inspections, by type

…with no type recorded6
Years with a record 8 calendar years (1999–2024)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it24139 - Convention (Subpart B), Gross Ton
14384 - Convention (Subpart B), Net Ton
50403 - Displacement, Ton
43366 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

28 June 2024 VRP Review
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7954802
9 January 2009 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3391326
9 January 2007 Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2852775
24 October 2006 Ballast Water Examination · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2806471
29 March 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2612349
29 March 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2638685
28 March 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2611651
23 February 2006 MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2588596
11 November 2004 PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2237345
16 June 2004 MTSA/ISPS Verification · Annual Inspection · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2099585
9 October 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 294509
15 May 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 277661
27 May 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 429084

Deficiency record · 3

Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 16 June 2004 Resolved
The manual for the Marine Sanitation Device (MSD) was not on board, resulting in the lack of maintenance on machinery, and improper addition of chemicals necessary to maintain a type II MSD. The crew was directed to implement and schedule a maintenance program according to the manual prior to the next U.S. port. 33 CFR 159.7
Action required: 15 - Rectify deficiencies by next port
Resolved 11 November 2004
Resolution: MSD manual and appropriate chemical tablets for type II MSD onboard vessel. Questioning of master, chief engineer, and crewman in charge of MSD operation confirmed their sufficient knowledge of MSD operation and maintenance in accordance with manual.
Fire Fighting
Issued 15 May 2000 Resolved
Cement patch on fire pump piping._x001C_ SOLAS 74 chap.I reg.11
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Engineering
Issued 15 May 2000 Resolved
Soft patch on auxillay salt water cooling line._x001C_ SOLAS 74 chap.I Reg 11.
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.