Records from 2002 to 2014. Most recent: inspection, 25 January 2014.
Inspection history · 29
25 January 2014
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4788915
29 February 2012
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4252990
21 July 2010
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 3802162
9 May 2010
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3748317
7 December 2009
ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3645989
11 August 2009
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3562369
9 July 2009
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3528674
4 June 2009
ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3493968
16 December 2008
PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3379611
9 August 2008
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3293477
29 May 2008
ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3221761
19 May 2008
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3211040
23 March 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2610256
19 March 2006
Type not recorded
No type recorded · Station Bellingham · USCG Northwest District (CGD-NW) · Activity 2605286
8 March 2006
Type not recorded
No type recorded · Station Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2627338
9 September 2005
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2537345
31 August 2005
Random ISPS/MTSA/PSC
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2480144
30 August 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2479400
10 September 2004
ISPS II Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2192370
28 July 2004
NPV Safety Exam · ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2147170
15 July 2004
NPV Safety Exam · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2130466
1 May 2004
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2057503
24 November 2003
Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 1953385
10 October 2003
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1928118
11 August 2003
Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 1875313
31 July 2003
MARPOL Annex I Examination · Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1861835
8 May 2003
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 1809904
8 May 2003
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2612385
24 July 2002
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1651934
Lifesaving › Lifebuoys › Size
Issued 4 June 2009
Resolved
0600; The light / smoke lifebuoy combination calls for a buoy weighing 4kg which was not on board. Also there were only two line throwing devices on board. The buoys must be replaced with the correct weight and an exempting letter must be on board for requiring only two line throwing devices.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 June 2009
Resolved 9 July 2009
Resolution: New lifebuoys of 4kg were place on board to the satisfaction of Transport Canada.
Documentation › Logs/Records › Oil Record Book
Issued 4 June 2009
Resolved
1710; The Oil Record Book is outdated. The Chief Engineer is using the incorrect items numbers for recording bunkering and weekly recordings of tanks name, size and capacity after soundings as per IOPP Certificate section 3.1.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 June 2009
Resolved 9 July 2009
Resolution: A new Oil Record Book was placed on board to the satisfaction of Transport Canada.
Electrical › Electric Generation Source (service) › Neutral Ground
Issued 4 June 2009
Resolved
0950; The electrical junction box for the wires leading to the steering unit which is located in the engine room port side is not properly covered. The wires are wrapped in electrical tape but still could cause someone to become injured if touched. A proper type of junction box must be provided for the safety of the crew.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 June 2009
Resolved 9 July 2009
Resolution: The junction box was replaced to the satisfaction of Transport Canada.
Construction/Loadline › Hull › Hull Plating
Issued 4 June 2009
Resolved
1200; Load Line items noted. Doors to the upper deck aft of house no longer weather-tight. Galley entrance door P/S not weather tight. Bow Thruster vent port not weather tight. Crack approx. 9cm on deck starboard side aft near tow bit. Starboard side, two windows on upper deck and four windows on main deck cracked. Bulwark starboard side frames bent gunnel cracked. Port aft bulwark wasted.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 June 2009
Resolved 9 July 2009
Resolution: Galley door gaskets were renewed / weather tight, Bow Thruster vent repaired, Double placed over 9cm crack, Bulwark repaired, upper deck doors were repaired and the windows are on order and will be installed ASAP to the satisfaction of Transport Canada.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 4 June 2009
Resolved
0300; In the wash / dry provision room there is approximately 20 feet of deck that is wasted. It is located at the end of the deck and has been covered up with a deck filler. You can see the wastage by going into the lower deck store area behind the fresh water tank. There are no records on board to indicate when this was covered up.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 June 2009
Resolved 9 July 2009
Resolution: Section of deck was cut out and replaced to the satisfaction of Transport Canada.
Documentation › Certificates/Documents › IOPP Certificate
Issued 15 July 2004
Resolved
IOPP Certificate requires annual survey. Current certificate exceeds month requirement. MARPOL Annex I Reg.4(1)(c).
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 July 2004
Resolved 28 July 2004
Resolution: Corrected.
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 15 July 2004
Resolved
Obtain and place on board a current copy of ISM-DOC. ISM Code Reg. 13.6.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 July 2004
Resolved 28 July 2004
Resolution: Corrected.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 15 July 2004
Resolved
Obtain date of Safety Construction Certificate 2004 endorsement. SOLAS 74 Ch. I Reg 14.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 July 2004
Resolved 28 July 2004
Resolution: Corrected.
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 15 July 2004
Resolved
Obtain current safe manning certificate. SOLAS Ch. V Reg 13.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 July 2004
Resolved 28 July 2004
Resolution: Corrected.
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 15 July 2004
Resolved
Provide daylight signal light. SOLAS Ch. V Reg. 11.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 July 2004
Resolved 28 July 2004
Resolution: Corrected.
Documentation › Markings/Placards › Warning Signs
Issued 15 July 2004
Resolved
Provide and install steering gear block diagram/instruction for emergency changeoevr. SOLAS Ch. V Reg. 19.2.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 July 2004
Resolved 28 July 2004
Resolution: Corrected.
Communications › Radio Communications › VHF Radiotelephone
Issued 15 July 2004
Resolved
Re-new expired batteries for GMDSS handheld VHF radios. SOLAS Ch. III Reg. 62.2.1.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 July 2004
Resolved 28 July 2004
Resolution: Corrected.
Documentation › Markings/Placards › Hull Identification Number (HIN)
Issued 15 July 2004
Resolved
Call sign must be posted near radio installation. Prove proper operation of single side band radio. SOLAS Ch. IV Reg. 6.2.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 July 2004
Resolved 28 July 2004
Resolution: Corrected.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 15 July 2004
Resolved
Amend fire control plan to properly reflect current location of fireman's outfits, fire control plans and line throwing appliances. SOLAS Ch. II-2 Reg. 20.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 July 2004
Resolved 28 July 2004
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 July 2004
Resolved
Provide globe/cover for light in ECR and at crew mess. SOLAS Ch. II-1 Reg 27.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 July 2004
Resolved 28 July 2004
Resolution: Corrected.
Engineering › Diesel Engine (propulsion-direct drive) › Nozzle, Injection (fuel injection)
Issued 15 July 2004
Resolved
Properly protect high pressure oil lines on main engines and generators as necessary. SOLAS Ch II-2 Reg. 15.9 - 15.11.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 July 2004
Resolved 28 July 2004
Resolution: Corrected.
Fire Fighting › Miscellaneous Items
Issued 10 October 2003
Resolved
Obtain class or administration approval for fire control plan as required. Correct to the satisfaction of attending marine inspector. LEGACY COMPONENT DESC: Fire Control Plan
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 November 2003
Resolved 24 November 2003
Navigation › Piloting/Steering
Issued 31 July 2003
Resolved
Provide a currently corrected copy of Coast Pilot Vol. 7, Light List and 2003 Tidal Current Tables. 33 CFR 164.33 LEGACY COMPONENT DESC: Nautical Publications
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 11 August 2003
Construction/Loadline › Markings
Issued 31 July 2003
Resolved
Mark loadline in contrasting colors to the hull. ICLL 66 Reg 8. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 11 August 2003
Lifesaving › Line-Throwing Appliances
Issued 31 July 2003
Resolved
Provide 4 chrages for line throwing device. 60 SOLAS Ch III/23. LEGACY COMPONENT DESC: Projectiles
Condition: Unknown
Due 8 August 2003
Resolved 11 August 2003
Lifesaving › Lifeboat
Issued 31 July 2003
Resolved
Obtain class/administration approval for damage and repairs made to lifeboat. 60 SOLAS III/5. LEGACY COMPONENT DESC: Damage
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 11 August 2003
Resolution: Flag State amended safety equipment removing lifeboat. There are liferafts both port and stbd with a rescue boat aft port.
Fire Fighting › Miscellaneous Items
Issued 31 July 2003
Resolved
Update fire control plan with proper int'l symbols to include international shore connection and post on both sides of the house in a weather tight container. 74 SOLAS Ch II-2/20. LEGACY COMPONENT DESC: Fire Control Plan
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 September 2003
Resolved 10 October 2003
Resolution: Vessel has obtained a new/appropriate fire control plan as required.
Fire Fighting › International Shore Connection
Issued 31 July 2003
Resolved
Provide means to make international shore connection usable. 60 SOLAS Ch. II/56h. LEGACY COMPONENT DESC: Connection
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 11 August 2003
Pollution Prevention/Response › Prevention Equipment
Issued 31 July 2003
Resolved
Provide standard discharge connection. (Iopp Cert. indicates installation however no flange or connection point could be located). 33 CFR 155.430. LEGACY COMPONENT DESC: Standard Discharge Connection
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 11 August 2003
Fire Fighting › Firemans Outfit
Issued 31 July 2003
Resolved
Provide two complete fireman's outfits. 60 SOLAS Ch. II/63. LEGACY COMPONENT DESC: Self-Contained Breathing Apparatus
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 11 August 2003
Resolution: Crew dressed out and operated equipment
Documentation › Certificates/Documents
Issued 31 July 2003
Resolved
Provide International Loadline Certificate meeting the requirements of ICLL 66 Article 18(2) and Annex III. LEGACY COMPONENT DESC: International Load Line Certificate
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 11 August 2003
Operations/Management › Vessel Safety Management
Issued 8 May 2003
Resolved
Provide evidence of complience with SOLAS Chap IX - International Safety Management Code.
Vessel required to have valid DOC & SMC documents aboard. LEGACY COMPONENT DESC: External Certification/Verification/Control
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 6 June 2003
Resolved 6 June 2003
Resolution: ABS Issued interm/temp DOC & SMC with final audit scheduled prior to 21 October 2003.
Documentation › Certificates/Documents
Issued 8 May 2003
Resolved
Vessel required to be in compliance with SOLAS Chap I, Reg 12 - Missing and Incomplete SOLAS Certificates.
Vessel required to have a valid Safety Construction Certificate & Approved Fire Control Plan aboard. LEGACY COMPONENT DESC: Cargo Ship Safety Construction Certificate
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 6 June 2003
Resolved 6 June 2003
Resolution: Transport Canada Inspections issued interm/temp Safety Construction Certificate valid to 11 July 2003 and accepted/approved the present Fire Control Plan.
Pollution Prevention/Response › Prevention Equipment
Issued 8 May 2003
Resolved
OWS system needs to be fitted with a discharge oil content meter and alarm system or properly exempted on the IOPP Certificate. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 6 June 2003
Resolved 6 June 2003
Resolution: OWS was properly fitted with a discharge meter and alarm system.
Documentation › Certificates/Documents
Issued 8 May 2003
Resolved
Vessel required to have a valid IOPP Certificate including form "A" or an valid Exemption Certificate aboard.
The IOPP Certificate indicates the past two annual surveys has not been completed as the certificate has not been endorsed since it was issued on 02 April 2001. LEGACY COMPONENT DESC: IOPP Certificate
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 6 June 2003
Resolved 6 June 2003
Resolution: New IOPP Certificate valid until 01 Aprial 2006 is onboard.
Documentation › Logs/Records
Issued 8 May 2003
Resolved
An oil record book was on board, but most entries were incorrect and/or incomplete. This one log had entries more than six years prior, mainly recording of amounts of fuel/oil struck onboard. No correct entries for discharge of the OWS system and the vessel's masters had never signed the log. LEGACY COMPONENT DESC: Oil Record Book
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 6 June 2003
Resolved 6 June 2003
Resolution: New oil record book has been started, Master & Chief engineer have been instructed on making proper entries.