MAURY USCG vessel records Sign in
← All vessels

STJERNEBORG

STJERNEBORG is a 1994 freight ship. The Coast Guard has recorded 32 inspections since 1994, most recently in May 2014, along with 26 deficiencies and 8 operational controls.

Records from 1994 to 2014. Most recent: inspection, 9 May 2014.

Built
1994
Last inspected
9 May 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8508369 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V8703
404183
Flag
SINGAPORE
—
Maury page id
psix-404183

Inspections, by type

…with no type recorded18
Years with a record 12 calendar years (1994–2014)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it20370 - Convention (Subpart B), Gross Ton
6111 - Convention (Subpart B), Net Ton
10517 - Dead Weight, Ton
23684 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

9 May 2014 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4854111
5 May 2014 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4851124
2 May 2014 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4847725
24 August 2011 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4126712
23 August 2011 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4119453
22 August 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4124386
31 May 2008 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3222818
24 March 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3170136
26 September 2007 Random ISPS/MTSA/PSC
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3066401
18 September 2007 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3060671
15 September 2007 MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · PI Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3058160
14 September 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3057302
27 April 2007 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2916967
27 April 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2917073
26 April 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2916615
25 April 2007 MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2915569
19 April 2007 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2910709
21 February 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1488273
15 February 2002 Annual Inspection · In-Service Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1486868
14 October 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 282935
6 October 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 433478
19 April 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 427673
30 September 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 421030
2 May 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 403202
21 June 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 392619
21 December 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 55645
21 December 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 385890
13 October 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 383719
24 May 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 378965
18 January 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 374399
15 July 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 368696
15 July 1994 Control Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 860634

Deficiency record · 26

Navigation › Piloting/Steering › Gyro Compass
Issued 2 May 2014 Resolved
1540 - Gyro Compass - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all all respects will remain fit to proceed to sea without danger to the ship or person onboard. The gyrocompass has a 10 second delay. -74 SOLAS (09) I/11
Action required: 705 - Other - as specified
Due 2 June 2014
Resolved 9 May 2014
Resolution: Recived Class report attesting to the replacement of the faulty gyro-compass.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 May 2014 Resolved
1299 - Guard rails - Guard rails fitted on superstructure and freeboard decks shall have at least three courses. The opening below the lowest course of the guard rails shall not exceed 230 mm. The third course is missing between the fifth and sixth stanchions, starboard side aft of forward crane. -ICLL Annex I/25.3
Action required: 705 - Other - as specified
Due 2 June 2014
Resolved 9 May 2014
Resolution: Received a class report and photos attesting to the repair of the damaged guard rail.
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 August 2011 Resolved
1530- Ships shall be fitted with a 9 GHz radar or other means to assist in navigation and collision avoidance. The ship's 9GHz radar is not fully operational. 74 SOLAS(2009) V/19.2.3.2 60A/C Prior to Movement
Due 23 August 2011
Resolved 24 August 2011
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 August 2011 Resolved
1530- Ships of 3000GT and upward shall have a 3GHz radar. The ship's 3GHz radar is not fully operational. SOLAS74(2009) V/19.2.7.1 60A/C Prior to Movement
Due 23 August 2011
Resolved 24 August 2011
Fire Fighting › Combustible Materials › Insulation
Issued 23 August 2011 Resolved
1499- The shall be maintained and fit to proceed to sea without presenting a hazard to the crew. The main diesel engine manifold and no. 1 lube oil heater have excessive wastage and metal cans with paint and paint thinner are being stowed in the engine room machinery space. SOLAS74(2009) I/11 17A/C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2011
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 23 August 2011 Resolved
Electrical installations shall be such that the safety of the crew and ship from electrical hazards shall be ensured. Clothes washer installed in water closet next to the bridge has multiple extension cords. SOLAS74 II-2/27
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2011
Engineering › Steam System (main) › Piping
Issued 23 August 2011 Resolved
1499- All conditions on the vessel must be maintined in accordance with the most recent survey. Part of the piping arrangement leading to the accomodation boiler is missing. SOLAS74(2009) I/11 70A/C
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 August 2011
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Pump
Issued 23 August 2011 Resolved
0740- All conditions on the vessel must be maintained in accordance with the most recent survey. The fire general service pump i sactively leaking. SOLAS74(2009) I/11 70A/C
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 August 2011
Construction/Loadline › Structures › Door
Issued 23 August 2011 Resolved
1270- All doors in superstructure shall be fiitted with gaskets and therefore be weathertight when closed. Doors are not fitted properly with gaskets, leading to galley. ICLL Annex I/12.1 70A/C
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 August 2011
Engineering › Steering Gear System › Ram
Issued 24 March 2008 Resolved
While conducting steering gear test PSCOs witnessed mechanical binding while rudder angle indicator was reading between 30-35 degrees port. It appears that the stbd side ram connecting arm to rudder connection has excessive clearance due to worn or missing friction bearing. Class to attest to proper operation of steering gear components and that they are sound and reliable/ SOLAS 74(81) II-2/40
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2008
Resolution: REPAIRS COMPLETED TO THE SATISFACTION OF CLASS.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 24 March 2008 Resolved
PSCOs witnessed excessive steam flash off from condensate tank. Upon further investigation, PSCOs witnessed saturation of water droplets in the overhead. The smoke detector in the immediate overhead was tested and did not work as designed due to the saturation. In addition, two lighting fixtures in the vicinity were also rendered inoperable due to water damage. Class to attest to the proper repair
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2008
Resolution: REPAIRS COMPLETED TO THE SATISFACTION OF CLASS.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 24 March 2008 Resolved
The ramp fire door to engine room trunk stairway, is not fitted with a self closing device. Class to attest to proper operation of fire door. SOLAS 74 (81) II-2/47
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2008
Resolution: REPAIRS COMPLETED TO THE SATISFACTION OF CLASS.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 March 2008 Resolved
Deck railing on weather deck, (topside of ramp, leading to upper deck) on the port side is broken off at the bracket/stanchion. Directly aft of the broken railing another is severely bent. Master explained that the damage is due to loading/unloading containers. Class to attest to the proper repairs of the deck railings. ILLC 66 Annex I/25.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 May 2008
Resolution: Recieved BV Class Report ALX0/2008/J0104 attesting to repairs.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 26 September 2007 Resolved
The starboard lifeboat engine did not start due to dead batteries (SOLAS 04 CH III REG 31.1.1.1.1, LSA 4.4.6.2).
Due 26 September 2007
Resolved 26 September 2007
Resolution: Batteries replaced
Lifesaving › Lifeboat Equipment › Food Ration
Issued 26 September 2007 Resolved
04 Port lifeboat food rations were wasted (SOLAS 04 CH III REG 31.1.1.1.1, LSA 4.4.8.12).
Due 26 September 2007
Resolved 26 September 2007
Resolution: New food rations were placed in the lifeboat
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 26 September 2007 Resolved
Evidence was found that a PWSA crewmember was living in sickbay (PWSA, 33 USC1223B).
Due 26 September 2007
Resolved 26 September 2007
Resolution: Crew cleaned hospital space and secured gear adrift.
Navigation › Collision/Grounding Avoidance › Radar
Issued 27 April 2007 Resolved
Vessel issued LOD for inoperable second radar 33 CFR 164.37(a). Equipment to be repaired prior to departure from port and tech report to be faxed to this office.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2007
Resolution: Rcv''d Tech Report from Radio Holland, system tested and in good order.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 April 2007 Resolved
The vessel's Oily Water Separator (OWS) was found to be in an unusable and inoperative condition.The vessel is required to provide documentation from the certificate issuing authority attesting to the proper repair and operation of the OWS prior to departure. The vessel is placed on IMO detention.
Action required: 705 - Other - as specified
Resolved 2 May 2007
Resolution: Rcv''d Class Report (BV) OWS is now operational. Marine Inspector on board vsl to witness proper operation as well. C/E and BV surveyor stated OWS is never used, all slops go to holding tanks and transferred ashore.
Documentation › Logs/Records › Oil Record Book
Issued 19 April 2007 Resolved
The crew was unable to provide more than a few weeks worth of Oil Record Book entries.The previous 3 years of Oil Record books were missing. The vessel is required to rectify the deficiency with in 30 days to the satisfaction of the administration.
Action required: 705 - Other - as specified
Due 20 May 2007
Resolved 20 April 2007
Resolution: Recieved report from the classification society on behalf of the Administration attesting to the presence of Oil Record Books from the previous three years.
Engineering › Diesel Engine (propulsion-electric) › Cylinder
Issued 19 April 2007 Resolved
The vessel's main diesel engine has fuel oil leak on numerous cylinders. The vessel is required to provide documentation from the certificate issuing authority attesting to the proper repair and operation of the MDE. Prior to departure.
Action required: 705 - Other - as specified
Resolved 20 April 2007
Resolution: recieved class report attesting to the proper repair and operation of the MDE.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 19 April 2007 Resolved
Numerous fire doors located in the vessel's main ladder well failed to operate properly. Vessel is required to provide documentation attesting to the proper repair and operation of all the fire doors located in the ladder well.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2007
Resolution: recieved class report attesting to the proper repair and operation of all the fire doors located in the ladder well.
Documentation
Issued 24 May 1995 Resolved
NUMEROUS IMPROPER SHIPPING NAMES ON DANGEROUS CARGO MANIFEST.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Navigation
Issued 24 May 1995 Resolved
VESSEL WAS GRANTED DIVIATION FROM NAVIGATION REGULATIONS FOR A MALFUNCTIONING GYROCOMPASS.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Lifesaving
Issued 15 July 1994 Resolved
SERVICE FORWARD LIFERAFT HYDROSTATIC RELEASE UNIT, PROVIDE TECHNICIAN SERVICE REPORT TO LOCAL U.S.C.G. PRIOR TO DEPARTING PORT.
Condition: Unknown
Due 20 July 1994
Resolved 20 July 1994
Navigation
Issued 15 July 1994 Resolved
INSTALL STEERING GEAR HYDRALIC FLUID LOW LEVEL ALARM ON BRIDGE, PROVIDE CLASS SOCIETY REPORT TO LOCAL U.S.C.G. PRIOR TO NEXT U.S. VOYAGE OR 30 AUG94, WHICHEVER COMES FIRST.
Condition: Unknown
Due 20 July 1994
Resolved 20 July 1994
Navigation
Issued 15 July 1994 Resolved
PROVIDE CLASS SOCIETY REPORT ATTESTING TO SATISFACTORY OPERATION OF STEERING GEAR ROOM COURSE HEADING REPEATER, PRIOR TO NEXT U.S. VOYAGE OR 30AUG94, WHICHEVER COMES FIRST.
Condition: Unknown
Due 20 July 1994
Resolved 20 July 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.