Records from 1994 to 2026. Most recent: inspection, 28 January 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 44
28 January 2026
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8278209
14 July 2025
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8186496
15 January 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8063894
2 October 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8013583
5 December 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7833706
20 September 2023
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7795145
12 September 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7790862
17 May 2022
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7453996
1 December 2021
Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7359371
19 May 2021
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7205431
24 July 2020
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6971866
9 December 2019
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6867023
23 September 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6818567
16 May 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6726412
15 May 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6421047
4 October 2017
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6276845
5 June 2017
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6166238
16 May 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6170263
14 September 2016
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5999649
12 August 2015
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5213960
28 July 2015
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5198442
20 July 2015
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5186166
27 June 2014
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4901425
8 July 2011
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4080172
14 September 2010
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3849490
5 July 2007
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3099250
4 May 2007
Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2922066
17 August 2006
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2750920
18 November 2005
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2536877
13 April 2005
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2332015
21 October 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2233204
9 October 2003
Annual Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1923841
10 September 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1673232
3 August 2001
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1068820
7 June 2001
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1068821
9 September 1998
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 799582
7 July 1998
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1129822
31 July 1997
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 778987
4 October 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1146101
8 August 1996
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1087622
12 June 1996
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 880037
14 July 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1421006
22 July 1994
Plan Review "T" Boat · Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1173192
20 May 1994
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1172431
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2024
Resolved
46 CFr 182.20-40(b)(3) {Old T} - Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line. The shutoff valve at the tank shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck. Vessel does not have shutoff valves at the tank.
Action required: 705 - Other - as specified
Due 31 December 2024
Resolved 14 July 2025
Resolution: Verified fuel shut off installation
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 2 October 2024
Resolved
46 CFR 4.06-15(a)(1) - The marine employer must have a sufficient number of alcohol testing devices readily accessible onboard the vessel to determine the presence of alcohol in the system of each individual who was directly involved in a SMI. Vessels testing strips were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 14 July 2025
Resolution: Verified testing with shoreside facility.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 September 2023
Resolved
13104 - On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Vessel's rear compartment high water level visual and alarm was inoperable.
46 CFR 182.530(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 September 2023
Resolution: Vessel send a video showing the high level alarm operating.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 September 2023
Resolved
11117 - Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Ring life buoy retroreflective tape was found to be wasted.
46 CFR 185.604(i)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 September 2023
Resolution: Vessel sent photographic evidence of new retro on the lifebuoy.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 12 September 2023
Resolved
18299 - The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. No alcohol testing devices maintained onboard vessel.
46 CFR 4.06-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 September 2023
Resolution: The vessel owner sent photographic evidence of new alcohol test strips.
09 - Working and Living Conditions › 091 - Living Conditions › Record of inspection (Accommodation)
Issued 12 September 2023
Resolved
09122 - A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 September 2023
Resolution: The vessel sent photographic evidence of a new first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 May 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2022
Resolved 23 May 2022
Resolution: New pubs were produced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 May 2022
Resolved
Each floating waterlight must be approved in accordance with 161.010 in subchapter Q of this chapter, including but not limited to 160.110. Floating waterlight was operational but had an expired battery. Replace battery. 46CFR180.70(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 23 May 2022
Resolution: New battery installed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 14 September 2016
Resolved
No hydrostatit test date found on the pre-engineered fixed fire fighting system. Provide adaquate servicning certificate/proof of servicing for the pre-engineered fixed fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2016
Resolved 16 May 2017
Resolution: An attending Coast Guard Marine Inspector verified that the vessel had a new extinguisher bottle (w/current Hydro date) for fixed FF system in E/R. We also conducted OP Test of fixed FF system; ALL SAT.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 September 2016
Resolved
Six lifejackets found in worn condition. Repair or replace lifejackets to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2016
Resolved 28 September 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 September 2016
Resolved
RLB waterlight battery found expired. Replace with a non-expired battery to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 September 2016
Resolved 16 September 2016
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 20 July 2015
Resolved
Vessel's engine tachometer at operating station is not not displaying any RPMs. Issued CG-835 requiring repair of gauge and reinspection within 07 days. 46 CFR 182.410(b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2015
Resolved 28 July 2015
Resolution: Vessel owner replaced inoperable tachometer with a new and functional one. All sat.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 20 July 2015
Resolved
Vessel does not have any emergency instructions onboard, as required by 46 CFR 185.510 (a). Issued CG-835 requiring emergency instructions to be posted onboard vessel within 07 days. Emphasized requirement for instructions to be specific to vessel arrangements and manning.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 July 2015
Resolved 12 August 2015
Resolution: Received emergency instructions for vessel as required by 46 CFR 185.510; all sat.
Lifesaving › Lifefloat › Serviceable
Issued 1 July 2014
Resolved
Life float is condemned and must be destroyed. Until new life float is placed on board, the vessel is restricted to operate in warm water only.
Due 31 October 2014
Resolved 6 August 2014
Resolution: Vessel Life Float has been removed and destroyed by owner/operator. Vessel allowed to operate only during warm water period 01June to 31 Oct as identified on vessel COI.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 1 July 2014
Resolved
Improper repair found on cooling line to heat exchanger. Repair as original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2014
Resolution: Old cooling line removed and new cooling line (Authorized hose) installed, all sat.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 1 July 2014
Resolved
B-I fire extinguisher required at operating station. Replace as new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2014
Resolution: New B-I fire extinguisher installed and verified during visit to vessel.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 July 2014
Resolved
All-round light was inoperable and lens was cracked. Repair/replace as new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2014
Resolution: New light installed and checked by attending MI, all sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 July 2014
Resolved
Multiple first aid kits with expired medicine on board. Replace as new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2014
Resolution: Expired Medicines from medical kit removed and replaced with new items.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 1 July 2014
Resolved
Provide copy of Light List for operating area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2014
Resolution: New Light list onboard vessel all, sat.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 July 2014
Resolved
Relabel and replaces grab line around ring buoy. Attach line around body not grab line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2014
Resolution: Grab line installed as required (yellow in color). Vessel owner informed that this line will detriorate sooner then black line due to sun damage. Owner stated that he understood and will replace it as needed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 July 2014
Resolved
Replace floating waterlight battery. Must be replaced annually.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2014
Resolution: Water light batteries replaced and light float tested all sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 July 2014
Resolved
Dead end wiring found on engine. Repair with proper connections.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2014
Resolution: Dead end wiring removed and proper wiring connections made, all sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 July 2014
Resolved
Found exposed wiring on starboard side of engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2014
Resolution: Wiring made fast on stbd side of MDE.
Documentation › Markings/Placards › Garbage Placard
Issued 1 July 2014
Resolved
Garbage placard is faded. Replace as new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2014
Resolution: Owner renewed Garbage Placard, all sat.
Lifesaving › Hand Flares › Storage
Issued 1 July 2014
Resolved
Provide waterproof box for distress signals.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2014
Resolution: Vessel owner made old waterproof box water tight by using sealing compound.
Stability › Watertight Integrity › General
Issued 1 July 2014
Resolved
Plug anchor locker so water does not drain into vessel or replace hatch with watertight hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2014
Resolution: Anchor locker hatch plugged, all sat.
Stability › Watertight Integrity › General
Issued 1 July 2014
Resolved
Replace aft hatch with watertight hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2014
Resolution: Owner refastened aft hatch, all sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 July 2014
Resolved
Replace dead end wiring in cabin/improper wiring connections found in cabin.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2014
Resolution: Dead end wiring removed and wire connections made fast as required.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 1 July 2014
Resolved
Missing 30x30 wire mesh for fuel tank vents.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2014
Resolution: Vessel owner installed wire mesh to both port and stbd fuel tanks.
Stability › Watertight Integrity › General
Issued 1 July 2014
Resolved
Water ingress observed in the staboard side lazarette. The plywood decking was saturated with water and collected in a puddle below the deck. Investigate source of water ingress and repair as new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2014
Resolution: Owner removed saturated deck area and replaced wasted deck with new deck covering, all sat.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 27 June 2014
Resolved
Provide training for drug and alcohol program for all crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2014
Resolution: Master and documented mate trained in vessel drug program.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 5 July 2007
Resolved
Provide for proper working RPM guage at operating station.
Action required: 705 - Other - as specified
Due 4 August 2007
Resolved 24 July 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 17 August 2006
Resolved
Prove properation of the automatic engine shut down.
Action required: 705 - Other - as specified
Due 31 August 2006
Resolved 12 September 2006
Documentation › Certificates/Documents › FCC SSL
Issued 17 August 2006
Resolved
Provide current Radio Safety Cert.
Action required: 705 - Other - as specified
Due 31 August 2006
Resolved 12 September 2006
Stability › Watertight Integrity › General
Issued 17 August 2006
Resolved
Properly replace the gasket on the aft deck hatch.
Action required: 705 - Other - as specified
Due 31 August 2006
Resolved 12 September 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 August 2006
Resolved
Properly label and place retro tape on the Life Ring
Action required: 705 - Other - as specified
Due 31 August 2006
Resolved 12 September 2006
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 17 August 2006
Resolved
Prove proper operation ofthe RPM indicator
Action required: 705 - Other - as specified
Due 31 August 2006
Resolved 12 September 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 November 2005
Resolved
Properly replace the line around the L/R.
Action required: 705 - Other - as specified
Due 23 November 2005
Resolved 23 November 2005
Engineering › Bilge Water Management System › Not Operational
Issued 18 November 2005
Resolved
Properly repair the lazzarette high lvl alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 November 2005
Stability › Watertight Integrity › General
Issued 21 October 2004
Resolved
Properly replace the gasket and the chain on the aft hatch cover.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 November 2004
Resolved 5 November 2004
Lifesaving › Rigid Liferafts › Markings
Issued 21 October 2004
Resolved
Properly label the life raft with the vessels name and max number of POB.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 November 2004
Resolved 5 November 2004
Lifesaving › Hand Flares › Expired
Issued 21 October 2004
Resolved
Properly replace the flares and smoke signals.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2004
Resolution: Recieved reciept for purchase of flares.
Documentation › Markings/Placards
Issued 9 October 2003
Resolved
Provide a new life jacket donning placard. LEGACY COMPONENT DESC: life jacket donning placard
Condition: Unknown
Due 9 November 2003
Resolved 6 November 2003
Documentation › Certificates/Documents
Issued 9 October 2003
Resolved
Post vessel's stability letter at the operating station. LEGACY COMPONENT DESC: Stability Letter
Condition: Unknown
Due 9 November 2003
Resolved 6 November 2003
Engineering › Bilge Water Management System
Issued 9 October 2003
Resolved
Repair the forward compartment bilge pump operating switch and run indicator. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 9 November 2003
Resolved 6 November 2003
Pollution Prevention/Response › Prevention Equipment
Issued 9 October 2003
Resolved
Remove oily rags from all bilges, clean bilges and remove all excess debris. Provide all bilges for follow up inspection. LEGACY COMPONENT DESC: Oily Residue (sludge/slop) Tank
Due 9 November 2003
Resolved 6 November 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 9 October 2003
Resolved
Double hose clamp all transmission oil cooler hoses.
Condition: Improper Installation
Due 9 November 2003
Resolved 6 November 2003
Lifesaving
Issued 9 October 2003
Resolved
Label life float passenger capacity in 3 inch lettering on top of life float. LEGACY COMPONENT DESC: life float
Condition: Improper/Lack of Maintenance
Due 9 November 2003
Resolved 6 November 2003
Navigation › Collision/Grounding Avoidance
Issued 9 October 2003
Resolved
Repair or replace the vessel's sound producing device. LEGACY COMPONENT DESC: sound producing device
Condition: Damaged By Earlier Event
Due 9 November 2003
Resolved 6 November 2003
Operations/Management
Issued 9 October 2003
Resolved
Replace expired aspirins in first aid kit. LEGACY COMPONENT DESC: first aid kit
Condition: Placed in Improper Service
Due 9 November 2003
Resolved 6 November 2003
Electrical
Issued 3 August 2001
Resolved
PROVIDE BATTERY BOXES FOR ALL BATTERIES ONBOARD VESSEL.
Condition: Unknown
Due 3 September 2001
Resolved 11 September 2001
Construction/Loadline
Issued 3 August 2001
Resolved
PROVIDE ADDITIONAL BILGE PUMP CONTROLS THAT INDICATE BILGE PUMP OPERATING CONDITION.
Condition: Unknown
Due 3 September 2001
Resolved 11 September 2001
Construction/Loadline
Issued 7 July 1998
Resolved
MAKE PERMANENT REPAIRS TO DELAMINATED AREA OF HULL STBD SIDE BENEATH FWD DECK DRAIN OVBD. INSURE CG INSPECTION AFTER AREA IS PREPARED; PRIOR TO INSTALLING NEW FIBERGLASS.
Condition: Unknown
Due 1 September 1998
Resolved 1 September 1998