Records from 2016 to 2026. Most recent: inspection, 28 January 2026.
Documentation record
Registered dimensions (L × B × D)50.2 ft × 14.9 ft × 7.3 ft
Registered tonnagegross 36 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNIFLITE INC · BELLINGHAM WA, UNITED STATES · built 1975
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portOCEAN CITY, MD
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36 - Simplified, Gross Ton
29 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
28 January 2026
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8278209
14 July 2025
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8186496
15 January 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8063894
2 October 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8013583
5 December 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7833706
20 September 2023
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7795145
12 September 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7790862
17 May 2022
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7453996
1 December 2021
Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7359371
19 May 2021
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7205431
24 July 2020
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6971866
9 December 2019
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6867023
23 September 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6818567
16 May 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6726412
15 May 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6421047
4 October 2017
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6276845
5 June 2017
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6166238
16 May 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6170263
14 September 2016
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5999649
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2024
Resolved
46 CFr 182.20-40(b)(3) {Old T} - Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line. The shutoff valve at the tank shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck. Vessel does not have shutoff valves at the tank.
Action required: 705 - Other - as specified
Due 31 December 2024
Resolved 14 July 2025
Resolution: Verified fuel shut off installation
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 2 October 2024
Resolved
46 CFR 4.06-15(a)(1) - The marine employer must have a sufficient number of alcohol testing devices readily accessible onboard the vessel to determine the presence of alcohol in the system of each individual who was directly involved in a SMI. Vessels testing strips were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 14 July 2025
Resolution: Verified testing with shoreside facility.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 September 2023
Resolved
13104 - On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Vessel's rear compartment high water level visual and alarm was inoperable.
46 CFR 182.530(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 September 2023
Resolution: Vessel send a video showing the high level alarm operating.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 September 2023
Resolved
11117 - Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Ring life buoy retroreflective tape was found to be wasted.
46 CFR 185.604(i)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 September 2023
Resolution: Vessel sent photographic evidence of new retro on the lifebuoy.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 12 September 2023
Resolved
18299 - The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. No alcohol testing devices maintained onboard vessel.
46 CFR 4.06-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 September 2023
Resolution: The vessel owner sent photographic evidence of new alcohol test strips.
09 - Working and Living Conditions › 091 - Living Conditions › Record of inspection (Accommodation)
Issued 12 September 2023
Resolved
09122 - A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 September 2023
Resolution: The vessel sent photographic evidence of a new first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 May 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2022
Resolved 23 May 2022
Resolution: New pubs were produced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 May 2022
Resolved
Each floating waterlight must be approved in accordance with 161.010 in subchapter Q of this chapter, including but not limited to 160.110. Floating waterlight was operational but had an expired battery. Replace battery. 46CFR180.70(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 23 May 2022
Resolution: New battery installed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 14 September 2016
Resolved
No hydrostatit test date found on the pre-engineered fixed fire fighting system. Provide adaquate servicning certificate/proof of servicing for the pre-engineered fixed fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2016
Resolved 16 May 2017
Resolution: An attending Coast Guard Marine Inspector verified that the vessel had a new extinguisher bottle (w/current Hydro date) for fixed FF system in E/R. We also conducted OP Test of fixed FF system; ALL SAT.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 September 2016
Resolved
Six lifejackets found in worn condition. Repair or replace lifejackets to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2016
Resolved 28 September 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 September 2016
Resolved
RLB waterlight battery found expired. Replace with a non-expired battery to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 September 2016
Resolved 16 September 2016