MAURY USCG vessel records Sign in
← All vessels

SANDY

SANDY is a 1957 freight ship. The Coast Guard has recorded 16 inspections since 1994, most recently in October 1999, along with 136 deficiencies and 6 operational controls.

Records from 1994 to 1999. Most recent: inspection, 18 October 1999.

Built
1957
Last inspected
18 October 1999
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5385730 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
404385
Flag
ANGUILLA
—
Maury page id
psix-404385

Inspections, by type

…with no type recorded16
Years with a record 6 calendar years (1994–1999)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it235 - Regulatory (Subpart C or D), Gross Ton
463 - Convention (Subpart B), Gross Ton
221 - Convention (Subpart B), Net Ton
650 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 16

18 October 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 433988
17 August 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 431862
16 June 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 429902
29 January 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 424482
6 October 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 422238
24 April 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 415274
30 March 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 414307
13 March 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 413868
19 August 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 406908
15 April 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 402159
17 March 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 401755
4 February 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 400190
17 December 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 398236
16 February 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 700685
13 February 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 65849
18 April 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 366284

Deficiency record · 136

Documentation
Issued 17 August 1999 Resolved
PRIOR TO DEPARTING THE PORT OF SAN JUAN, PROVIDE VALID ANNUAL ENDORSEMENT FOR CCSSC CERTIFICATE.
Condition: Unknown
Due 17 August 1999
Resolved 3 September 1999
Navigation
Issued 17 August 1999 Resolved
PROVIDE COPY OF SAILING DIRECTIONS NLT 17 SEP99.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Documentation
Issued 17 August 1999 Resolved
PROVIDE ANNEX 3 (EQUIPMENT PARTICULARS) FOR THE CCSSC CERTIFICATE NLT 17 SEP 99.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Lifesaving
Issued 17 August 1999 Resolved
PROVIDE NEW HYDRO RELEASE MECHANISM FOR EPIRB NLT 17SEP99.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Construction/Loadline › Structures › Air Pipe
Issued 17 August 1999 Resolved
REMOVE DUCT TAPE AND REPAIR FWD PORTSIDE BALLAST TANK VENT PIPE, TO THE SATISFACTION OF CLASS SURVEYOR NLT 17SEP99.
Condition: Unknown
Due 17 September 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Construction/Loadline › Structures › Air Pipe
Issued 17 August 1999 Resolved
RENEW BALLAST TANK FILL CAP FWD PORTSIDE TO THE SATISFACTION OF CLASS SURVEYOR NLT 17SEP99.
Condition: Unknown
Due 17 September 1999
Resolved 6 October 2004
Engineering › Diesel Engine (auxiliary) › Air Cleaner
Issued 17 August 1999 Resolved
REPAIR FUEL LEAK ON FOCSLE HYDRAULIC ENGINE TO THE SATISFACTION OF CLASS NLT 17 SEP99.
Condition: Unknown
Due 17 September 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Navigation
Issued 17 August 1999 Resolved
PROVIDE DIAGRAMATIC STEERING DRAWING IN PILOTHOUSE AND STEERING ROOM FOR EMERGENCY STEERING PROCEDURES NLT 17SEP99.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Documentation
Issued 17 August 1999 Resolved
INDICATE CORRECTLY ON THE CCSSC CERTIFICATE WETHER OR NOT AN EXEMPTION CERTIFICATE HAS BEEN ISSUED NLT 17 SEP 99.
Condition: Unknown
Due 17 September 1999
Resolved 3 September 1999
Navigation
Issued 17 August 1999 Resolved
PROVIDE 1999 COPY OF LIGHT LIST NLT 17SEP99.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Navigation
Issued 17 August 1999 Resolved
PROVIDE UPDATED DEVIATION TABLE FOR MAGNETIC NAVIGATION COMPASSES NLT 17SEP99.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Navigation
Issued 17 August 1999 Resolved
PROVIDE ADEQUATE & UPDATED CHARTS FOR INTENDED OPERATING AREA.
Condition: Unknown
Due 17 September 1999
Resolved 3 September 1999
Documentation
Issued 17 August 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 September 1999
Resolved 3 September 1999
Construction/Loadline
Issued 17 August 1999 Resolved
PRIOR TO DEPARTING PORT OF SAN JUAN, DEMONSTRATE PROPER OPERATION OF BILGE/BALLAST PUMP TO THE SATISFACTION OF THE CLASS SURVEYOR.
Condition: Unknown
Due 17 August 1999
Resolved 3 September 1999
Deck/Cargo › Cargo Stowage › General
Issued 17 August 1999 Resolved
PROVIDE CLASS SURVEYORS REPORT AS TO THE CONDITION OF THE CARGO CRANE MOUNTING FOUNDATIONS NLT 17SEP99.
Condition: Unknown
Due 17 September 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Engineering › Diesel Engine (auxiliary) › Air Cleaner
Issued 17 August 1999 Resolved
LAG EXHAUST PIPING FOR FOCSLE HYDRAULIC ENGINE, EMERGENCY GENERATOR, MAIN PROPULSION ENGINE, AND SHIPS ELECTRICAL GENERATOR TO THE SATISFACTION OF THE ADMINISTRATION IAW CCSSC 2.42 NLT 17SEP99.
Condition: Unknown
Due 17 September 1999
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Construction/Loadline
Issued 16 June 1999 Resolved
PROVE BILGE AND BALLAST PUMPING ARRANGEMENT PERVENTS THE POSSIBILITY OF WATER PASSING FROM THE SEA AND BALLAST TANKS INTO CARGO AND MACHINERY SPACES.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Navigation
Issued 16 June 1999 Resolved
PROVIDE A TECHNICIAN'S REPORT ATTESTING TO PROPER OPERATION OF THE MAIN RADAR.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Documentation
Issued 16 June 1999 Resolved
PROVIDE STABILITY CALCULATIONS FOR SUBJECT VESSEL.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Fire Fighting
Issued 16 June 1999 Resolved
HAVE CLASS ADDRESS CROSS CONNECTION OF THE VESSEL'S FIRE AND BILGE SYSTEM AND IT'S SUITABILITY TO OPERATE SIMULTANEOUSLY.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Fire Fighting
Issued 16 June 1999 Resolved
CROP AND RENEW WASTED FIREMAIN PIPING FORWARD OF FOSCLE'S ENTRANCE.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Unknown
Issued 16 June 1999 Resolved
PROVE PROPER OPERATION OF SHIP'S BILGE SYSTEM.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Fire Fighting
Issued 16 June 1999 Resolved
SATISFACTORILY TEST ALL FIRE HOSES.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Unknown
Issued 16 June 1999 Resolved
REMOVE ALL OILY RESIDUES FROM THE VESSEL'S MAIN DECK. ALL OILY RESIDUES MUST BE PROPERLY DISPOSED TO AN APPROVED FACILITY AND A RECEIPT PROVIDED TOLOCAL USCG OFFICE.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Deck/Cargo
Issued 16 June 1999 Resolved
REPAIR HYDRAULIC LEAKS AT MAIN DECK CRANE AND FORWARD EMERGENCY GENERATOR.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Electrical
Issued 16 June 1999 Resolved
REPAIR DIESEL FUEL LEAK AT EMERGENCY GENERATOR.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Electrical
Issued 16 June 1999 Resolved
CONDUCT FULL OPERATIONAL TEST OF THE EMERGENCY GENERATOR
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Fire Fighting
Issued 16 June 1999 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Fire Fighting
Issued 16 June 1999 Resolved
CONDUCT NECESSARY MODIFICATIONS TO VESSEL'S PAINT LOCKER TO MAINTAIN CO2 DISCHARGE WITHIN THE COMPARTMENT.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Navigation
Issued 16 June 1999 Resolved
PROVE PROPER OPERATION OF THE EMERGENCY STEERING SYSTEM AS WELL AS CREW'S CAPABILITY TO OPERATE THE SYSTEM.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Navigation
Issued 16 June 1999 Resolved
PROVIDE EMERGENCY STEERING INSTRUCTIONS AT THE REQUIRED LOCATION.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Lifesaving
Issued 16 June 1999 Resolved
PROVIDE PROPER MUSTER LIST CONDUCT SATISFACTORY ABANDONSHIP AND FIRE FIGHTING DRILLS.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Documentation
Issued 16 June 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Documentation
Issued 16 June 1999 Resolved
PROVIDE VALID LOAD LINE CERTIFICATE. LOADLINE CERTIFICATE NOTED ONBOARD SHOWED LAST DRYDOCK DATE 31AUG93.IF NO EVIDENCE IS PROVIDED, VESSEL MUST BEDRYDOCKED AND A MARINE SURVEYOR REPORT MUST BE PROVIDED TO LOCAL USCG.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Fire Fighting
Issued 16 June 1999 Resolved
PROVE PROPER OPERATION OF THE VESSEL'S MAIN FIRE PUMP AND FIREMAIN.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Construction/Loadline
Issued 16 June 1999 Resolved
PROVE PROPER OPERATION OF PORTABLE BILGE PUMP.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Deck/Cargo
Issued 16 June 1999 Resolved
PROVIDE ACCESS (REMOVE WOOD PLANKS) TO AT LEAST 6 AREAS WITHIN THE CARGO HOLD IN ORDER TO EXAMINE BOTTOM LONGITUDINAL AND TRANSVERSE STRUCTURAL FRAMING, INCLUDING OUTSIDE PLATING OF BALLAST TANKS.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Deck/Cargo
Issued 16 June 1999 Resolved
PROVE PROPER OPERATION OF PORT SIDE ANCHORING SYSTEM, INCLUDING OPERATION OF WINCH AND CAPSTAN.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Documentation
Issued 29 January 1999 Resolved
PROVISE A REPORT FROM CLASS ADDRESSING CORRECTION TO 6 OUTSTANDING ITEMS PREVIOUSLY ISSUED DURING 06OCT98.
Condition: Unknown
Due 29 January 1999
Resolved 2 March 1999
Documentation
Issued 29 January 1999 Resolved
PROVIDE A REPORT FROM CLASS SOCIETY ADDRESSING 23,580 GROSS TONAGE IN CCSSCCERTIFICATE.
Condition: Unknown
Due 29 January 1999
Resolved 2 March 1999
Documentation
Issued 29 January 1999 Resolved
PROVIDE PROPER CARGO SHIP SAFETY RADIO CERTIFICATE.
Condition: Unknown
Due 29 January 1999
Resolved 2 March 1999
Documentation
Issued 29 January 1999 Resolved
PROVIDE OIL RECORD BOOK AND RECEIPTS OF PROPER OIL DISPOSAL.
Condition: Unknown
Due 29 January 1999
Resolved 2 March 1999
Engineering
Issued 29 January 1999 Resolved
PROVIDE PROPER OILY WATER SEPARATING UNIT FOR VESSEL.
Condition: Unknown
Due 29 January 1999
Resolved 2 March 1999
Unknown
Issued 29 January 1999 Resolved
DISPOSE OF ALL OILY RESIDUES PRESENTLY LOCATED ON VSL BILGE TO AN APPROVED COAST GUARD FACILITY AND PROVIDE A RECEIPT OF PROPER DISPOSAL.
Condition: Unknown
Due 29 January 1999
Resolved 2 March 1999
Documentation
Issued 29 January 1999 Resolved
PROVIDE OWNERS ADDRESS AND NAME INCLUDING NAME AND ADDRESS OF OPERATING COMPANY.
Condition: Unknown
Due 29 January 1999
Resolved 2 March 1999
Documentation
Issued 29 January 1999 Resolved
PROVIDE VESSEL TONNAGE MEASUREMENT IAW ISSUED ITC CERTIFICATE.
Condition: Unknown
Due 29 January 1999
Resolved 2 March 1999
Documentation
Issued 29 January 1999 Resolved
PROVIDE COPY OF THE LOADLINE CERTIFICATE AND RECENT SURVEYS.
Condition: Unknown
Due 29 January 1999
Resolved 2 March 1999
Documentation
Issued 29 January 1999 Resolved
PROVIDE A REPORT FROM CLASS ADDRESSING CORRECTION OF ALL OUTSTANDING ITEMS ISSUED 06 OCT98 AND 12 JAN 99. REPORT MUST BE DETAILED AS FAR AS INDICATINGDISCREPANCIES AND CORRECTION MEASUREMENTS TAKEN.
Condition: Unknown
Due 29 January 1999
Resolved 2 March 1999
Unknown
Issued 6 October 1998 Resolved
PROVE OPERATION OF SSB RADIO.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Engineering
Issued 6 October 1998 Resolved
PROVIDE MISSING HEAT SHIELD ON RACOR FILTER GENERATOR E/R.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Lifesaving
Issued 6 October 1998 Resolved
LABEL VESSEL NAME ON RESCUE BOAT.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Construction/Loadline
Issued 6 October 1998 Resolved
REPAIR TO SATISFACTION OF CLASS ENGINEROOM BALAST TANK. TANK HAS LEAKING EPOXY PATCH.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Engineering
Issued 6 October 1998 Resolved
MISSING PORT AND STBD FUEL OIL VENTS. FIX TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Deck/Cargo
Issued 6 October 1998 Resolved
PROVIDE GUARD FOR HYDRAULIC CRANE PUMP SHAFT IN FORE PEAK TO SAQTISFACTION OF CLASS.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Navigation
Issued 30 March 1998 Resolved
PROVIDE ONBOARD A COPY OF NOTICE TO MARINERS.
Condition: Unknown
Due 1 May 1998
Resolved 3 November 1998
Documentation
Issued 30 March 1998 Resolved
PROVIDE COPIES OF IOPP CERTIFICATE, CLASSIFICATION DOCUMENT AND CERTIFICATEOF REGISTRY TO MSO SAN JUAN PRIOR TO DEPARTURE.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Lifesaving
Issued 30 March 1998 Resolved
PROVIDE PROPER MARKINGS IN ACCORDANCE WITH REQUIREMENTS OF PARAGRAPHS 4.2.6.3, 4.2.7, 4.3.6, AND 4.4.9 OF LSA CODE AS PER CCSSC CHAPTER 4 REG.4.5PAGE 70.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Electrical
Issued 30 March 1998 Resolved
PROVIDE EMERGENCY LIGHTING IN WHEELHOUSE.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Fire Fighting
Issued 30 March 1998 Resolved
PROVIDE FIRE EXTINGUISHER AT TOP OF STAIRWAY TO ENGINE ROOM.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Fire Fighting
Issued 30 March 1998 Resolved
PROVIDE TWO MORE EXTINGUISHERS IN ENGINE ROOM.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Electrical
Issued 30 March 1998 Resolved
INSTALL EMERGENCY LIGHT IN GALLEY AREA TO EXIT DOORS.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Engineering
Issued 30 March 1998 Resolved
INSTALL FUEL SHUT-OFF VALVE TO FUEL TANK ON STAND-BY GENERATOR.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Unknown
Issued 30 March 1998 Resolved
CONDUCT HOUSEKEEPING OF SPACE CONTAINING STAND-BY GENERATOR.
Condition: Unknown
Due 1 May 1998
Resolved 3 November 1998
Engineering
Issued 30 March 1998 Resolved
CONDUCT PERMANENT REPAIRS TO MAIN ENGINE COOL WATER OVERBOARD PIPE AT T- CONNECTION, PORT SIDE AFT, ABOVE ENGINE.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Deck/Cargo
Issued 30 March 1998 Resolved
PROVIDE CONTAINMENT UNDER FUEL OIL AND LUBE OIL VENTS ON MAIN DECK.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Unknown
Issued 30 March 1998 Resolved
PROVIDE HEARING PROTECTION FOR ENTRY INTO ENGINE ROOM.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Unknown
Issued 30 March 1998 Resolved
REMOVE OIL BUCKETS FROM POWER DISTRIBUTION PANEL AREA.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Navigation
Issued 30 March 1998 Resolved
PROVIDE PROVIDE THE VESSEL MANUEVERING INFORMATION AND POST ON BRIDGE.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Navigation
Issued 30 March 1998 Resolved
PROVIDE NECESSARY EQUIPMENT FOR ALTERNATE MEANS OF STEERING AND FUNCTION TEST IN PRESCENCE OF COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Lifesaving
Issued 30 March 1998 Resolved
PROVIDE ILLUMINATION AT LAUNCHING STATIONS FOR LIFERAFTS AND RESCUE BOAT UNDER EMERGENCY POWER SOURCE.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Fire Fighting
Issued 30 March 1998 Resolved
PROVIDE AN INTERNATIONAL SHORE CONNECTION.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Fire Fighting
Issued 30 March 1998 Resolved
PROVIDE PAINT LOCKER WITH FIXED FIREFIGHTING EQUIPMENT OR REMOVE ALL PAINT FROM VESSEL.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Navigation
Issued 30 March 1998 Resolved
REPLACE SHIP'S BELL WITH LARGER UNIT. I.A.W. COLREGS.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Navigation
Issued 30 March 1998 Resolved
REPAIR WEAK SHIP'S AIR HORN.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Documentation
Issued 30 March 1998 Resolved
COMMENCE RADIO LOG AS PER CCSS 5.7.1 WITH COPY TO MSO SAN JUAN.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Navigation
Issued 30 March 1998 Resolved
REPAIR INOPERATIVE NAVIGATION LIGHT PANEL WARNING LIGHTS.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Electrical
Issued 30 March 1998 Resolved
PROVIDE A C.B. BLANK TO OPENING IN C.B. PANEL ON BRIDGE NAVIGATION PANEL LIGHT.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Unknown
Issued 30 March 1998 Resolved
PROVIDE EFFICIENT VENTILATION TO BATTERY ROOM INSIDE ENGINE ROOM. I.A.W._x001C_ 2.32.9.1
Condition: Unknown
Due 1 May 1998
Resolved 3 November 1998
Electrical
Issued 30 March 1998 Resolved
INSTALL LIGHT FIXTURE AT TOP OF STAIRWAY FROM AFT ACCOMODATION TO MAIN DECK.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Engineering
Issued 30 March 1998 Resolved
INSTALL RIGID FUEL LINE TO STAND-BY GENERATOR FROM FUEL TANK.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Fire Fighting
Issued 30 March 1998 Resolved
PROVIDE ADDITIONAL FIRE EXTINGUISHER AT STAND-BY GENERATOR LOCATION.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Engineering
Issued 30 March 1998 Resolved
PROVIDE FLAME SHIELD BOWL TO RACOR FILTER FOR CRANE DIESEL/HYDRAULIC ENGINE.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Navigation
Issued 30 March 1998 Resolved
INSTALL COMPASS AS ORIGINAL EQUIPMENT ON BRIDGE.
Condition: Unknown
Due 1 May 1998
Resolved 3 November 1998
Fire Fighting
Issued 30 March 1998 Resolved
REPAIR INOPERATIVE SMOKE DETECTOR IN GALLEY.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Electrical
Issued 30 March 1998 Resolved
INSTALL LIGHT FIXTURE IN FIREMAN'S OUTFIT STORAGE ROOM.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Documentation
Issued 13 March 1998 Resolved
PROVIDE TO THE MSO SAN JUAN OFFICE MANUFACTURER DATA INFORMATION OF FIXED FIRE FIGHTING PRESSURE POT SYSTEMS IN THE ENGINE ROOM.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Lifesaving
Issued 13 March 1998 Resolved
REPLACE CURRENT ZODIAC RESCUE BOAT WITH A RIDIG HULL BOAT AS PER THE CARIBBEAN CARGO SHIP SAFETY CODE.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Lifesaving
Issued 13 March 1998 Resolved
INSTALL PROTECTIVE GUARD TO POWER TAKE-OFF UNIT FOR MAIN FIRE PUMP.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Documentation
Issued 19 August 1997 Resolved
PROVIDE INTERNATIONAL TONNAGE CERTIFICATE AS REQUIRED BY THE INTERNATIONAL CONFERENCE ON TONNAGE MEASUREMENT OF SHIPS,1969.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Lifesaving
Issued 17 December 1996 Resolved
PAINTS AND OTHER FLAMMABLES STORED THROUGHOUT THE VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 January 1997
Resolved 5 February 1997
Construction/Loadline
Issued 17 December 1996 Resolved
CONFERANCE ROOM FORWARD WINDOW LOCATED ON 01 DECK ON STARBOARD SIDE CRACKED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 January 1997
Resolved 5 February 1997
Documentation
Issued 17 December 1996 Resolved
OUTDATED TIDE CURRENTS AND TIDE TABLES_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Construction/Loadline
Issued 17 December 1996 Resolved
MISSING POLLUTION PLACARD
Condition: Unknown
Due 17 December 1996
Resolved 26 December 1996
Construction/Loadline
Issued 17 December 1996 Resolved
WASTED BULKHEAD ON FORWARD PART OF SUPERSTRUCTURE ON WEATHERDECK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Construction/Loadline
Issued 17 December 1996 Resolved
WASTED HATCH LEADING TO ENGINE ROOM LADDERWELL/ENGINEROOM LOCATED STARBOARDJUST FORE OF FIRE EQPT STREROOM ON 01 DECK. VESSEL CORRECTED DEFICIENCY 17MAR97.
Condition: Unknown
Due 5 January 1997
Resolved 20 March 1997
Construction/Loadline
Issued 17 December 1996 Resolved
BALLAST TANK VENTS/PIPING WASTED AND HOLED THROUGHOUT VESSEL. _x001C_ ILCC 66_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Fire Fighting
Issued 17 December 1996 Resolved
MAKE REPAIRS TO BALLAST/FIRE PUMP ENGAGEMENT DEVICE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1997
Resolved 17 April 1997
Electrical
Issued 17 December 1996 Resolved
LIGHT UNCOVERED AND WITH EXPOSED WIRING IN GALLEY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Fire Fighting
Issued 17 December 1996 Resolved
FIRE STATION NOT FULLY EQUIPPED WITH HOSES, WRENCH AND/OR NOZZLES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Construction/Loadline
Issued 17 December 1996 Resolved
MANHOLE GOING TO ENGINE ROOM LOCATED AFT TO STACK ON 02 DECK BEHIND WHEELHOUSE WASTED AND DISCONNECTED FROM HINGES AT DECK. VESSEL CORRECTED DEFICIENCY.
Condition: Unknown
Due 5 January 1997
Resolved 20 March 1997
Fire Fighting
Issued 17 December 1996 Resolved
MAKE REPAIRS TO FIREMAIN ON PORTSIDE BRIDGEDECK_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Fire Fighting
Issued 17 December 1996 Resolved
FIRE EXTINGUISHERS EXPIRED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 17 December 1996 Resolved
12 PARACHUTE FLARES EXPIRED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Documentation
Issued 17 December 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Electrical
Issued 17 December 1996 Resolved
LIGHT COVER MISSING IN PORTSIDE REFIGERATOR ROOM JUST AFT OF OFFICER'S DINING ROOM ON 01 DECK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Construction/Loadline
Issued 17 December 1996 Resolved
BRIDGE WINDOWS LOCATED: STARBOARD FRONT, STARBOARD HATCH AND AT CHART DESK CRACKED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 January 1997
Resolved 5 February 1997
Accommodation/Occupational Safety
Issued 17 December 1996 Resolved
HANDRAILS ON PORT/STARBOARD LIFERAFT EMBARKATION POINTS WASTED AND HOLES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Construction/Loadline
Issued 17 December 1996 Resolved
BOOBY HATCH LOCATED ON 01 DECK JUST FORWARD OF SUPERSTRUCTURE LEADING TO CREWS BERTHING MISSING ALL DOGS AND GASKETS. VESSEL CORRECTED DEFICIENCY 17MAR97.
Condition: Unknown
Due 5 January 1997
Resolved 20 March 1997
Accommodation/Occupational Safety
Issued 17 December 1996 Resolved
LADDERWELL LOCATED PORT BETWEEN 01-02 DECKS WASTED THROUGHOUT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Accommodation/Occupational Safety
Issued 17 December 1996 Resolved
HANDRAILS AT PORT/STARBOARD BOW MISSING AND/OR WASTED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Construction/Loadline
Issued 17 December 1996 Resolved
BOSUN'S LOCKER MANHOLE LOCATED AT BOW ADJACENT TO WINDLASS MISSING ALL DOGS/GASKETS. VESSEL CORRECTED DEFICIENCY 17MAR97.
Condition: Unknown
Due 5 January 1997
Resolved 20 March 1997
Accommodation/Occupational Safety
Issued 17 December 1996 Resolved
LADDERWELLS LOCATED AT BOW BETWEEN WEATHERDECK AND WHERE ANCHOR WINDLASS ISLOCATED WASTED THROUGHOUTY STRUCTURE. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Electrical
Issued 17 December 1996 Resolved
BOSUN'S LOCKER HAS EXPOSE WIRING, OPEN CIRCUIT/DISTRIBUTOR PANEL, UNCOVEREDLIGHT FIXTURES AND UNCOVERED ELECTRICAL OUTLETS. VESSEL CORRECTED DEFICIENCY 17MAR97.
Condition: Unknown
Due 5 January 1997
Resolved 20 March 1997
Lifesaving
Issued 17 December 1996 Resolved
LIFERAFTS NEED TO BE SERVICED/INSPECTED WITH VESSEL NAME, PORT AND CAPACITYMARKED ON THEM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Documentation
Issued 17 December 1996 Resolved
VESSEL IN NEED OF CURRENT/UP-TO-DATE COAST PILOT, LIGHT LIST, INLAND NAVIGATIONAL RULES AND AREA AND APPROACH CHARTS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 17 December 1996 Resolved
LIFEBUOYS DO NOT HAVCE REFLECTIVE TAPE/NAME OF VESSEL, ETC._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 17 December 1996 Resolved
EXPIRED EPIRB HYDROSTATIC RELEASE (2/96)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Accommodation/Occupational Safety
Issued 17 December 1996 Resolved
HANDRAIL PORT/STARBOARD AFT ON 02 DECK WASTED THROUGHOUT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Deck/Cargo
Issued 17 December 1996 Resolved
MAKE REPAIRS TO LEAKING AUXILLARY DIESEL ENGINE EXHAUST PIPING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 January 1997
Resolved 17 December 1996
Accommodation/Occupational Safety
Issued 17 December 1996 Resolved
LADDERWELL LOCATED AFT OF SUPERSTRUCTURE BETWEEN 01-02 DECKS WASTED THROUGHOUT. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 January 1997
Resolved 5 February 1997
Construction/Loadline
Issued 17 December 1996 Resolved
HATCH/DOGS AT STACK/AFT ON 02 DECK WASTED, FROZEN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Electrical
Issued 17 December 1996 Resolved
EXPOSED WIRING AT PORTSIDE BRIDGEWING.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 18 April 1994 Resolved
VSL HAS GEAR ADRIFT IN STEERING ROOM AND NOT SECURED.
Condition: Unknown
Due 3 May 1994
Resolved 24 May 1994
Lifesaving
Issued 18 April 1994 Resolved
VSL DOES NOT HAVE AN EPIRB AS PER NAVIC 9-93.
Condition: Unknown
Due 3 May 1994
Resolved 24 May 1994
Lifesaving
Issued 18 April 1994 Resolved
HYDROSTATIC RELEASES ON LIFERAFTS HAVE NOT BEEN ANNUALLY TESTED._x001C_ 46 C.F.R. 97.15-45.
Condition: Unknown
Due 3 May 1994
Resolved 24 May 1994
Lifesaving
Issued 18 April 1994 Resolved
LIFERAFTS ON VSL HAVE NOT BEEN ANNUALLY INSPECTED._x001C_ 46 C.F.R. 97.15-45
Condition: Unknown
Due 3 May 1994
Resolved 24 May 1994
Lifesaving
Issued 18 April 1994 Resolved
ALL OF VSL'S FLARES ARE OUTDATED.
Condition: Unknown
Due 3 May 1994
Resolved 24 May 1994
Lifesaving
Issued 18 April 1994 Resolved
BATTERIES IN E/R NOT SECURED AND NOT IN A BATTERY BOX.
Condition: Unknown
Due 3 May 1994
Resolved 24 May 1994
Lifesaving
Issued 18 April 1994 Resolved
VSL DOES NOT HAVE THE REQUIRED LIFE RINGS AS PER 46 CFR 94.43-10(a).
Condition: Unknown
Due 3 May 1994
Resolved 24 May 1994
Lifesaving
Issued 18 April 1994 Resolved
VSL'S THREE (3) LIFE RING BUOYS DO NOT HAVE LIGHTS AS REQUIRED BY_x001C_ 46 CFR 94.43-10.
Condition: Unknown
Due 3 May 1994
Resolved 24 May 1994
Navigation
Issued 18 April 1994 Resolved
VSL HAS NO LARGE SCALE HARBOR CHART, COAST PILOT, LIGHT LIST, TIDE TABLES ,OR TIDAL CURRENT TABLES._x001C_ 46 C.F.R. 97.05-5
Condition: Unknown
Due 3 May 1994
Resolved 24 May 1994
Fire Fighting
Issued 18 April 1994 Resolved
VSL'S FIRE EXTINGUISHERS HAVE NOT BVEEN ANNUALLY INSPECTED AS REQUIRED BY_x001C_ 46 CFR 95.25-20.
Condition: Unknown
Due 3 May 1994
Resolved 24 May 1994
Accommodation/Occupational Safety
Issued 18 April 1994 Resolved
LADDERS ON DECK WASTED WITH RUST AND ARE UNSAFE.
Condition: Unknown
Due 3 May 1994
Resolved 24 May 1994
Lifesaving
Issued 18 April 1994 Resolved
VSL HAS OIL ON DECK IN FOREPEAK.
Condition: Unknown
Due 3 May 1994
Resolved 24 May 1994
Documentation
Issued 18 April 1994 Resolved
VESSEL HAS NO EVIDENCE FROM FLAG STATE THAT IT IS SAFELY MANNED AND VESSEL HAS NO LICENSED OFFICERS ON BOARD._x001C_ VESSEL HIRED THREE U.S. OFFICERS TO COMPLY WITH A SAFE MANNING STATEMENT ISSUED BY ANTIGUA. CREW TO BE RE-CHECKED UPON RETURNING TO NEXT U.S. PORT
Condition: Unknown
Due 25 May 1994
Resolved 26 May 1994
Accommodation/Occupational Safety
Issued 18 April 1994 Resolved
VSL HAS NO HOT AND COLD FRESH WATER AVAILABLE IN ANY COMMUNAL WASH PLACES. NO WATER IN CREWS CABINS.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.