MAURY USCG vessel records Sign in
← All vessels

GENMAR GULF

GENMAR GULF is a 1991 tank ship. The Coast Guard has recorded 21 inspections since 1998, most recently in November 2010, along with 8 deficiencies and 1 operational control.

Records from 1998 to 2010. Most recent: inspection, 23 November 2010.

Built
1991
Last inspected
23 November 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8919154 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
404518
Flag
MARSHALL ISLANDS
—
Maury page id
psix-404518

Inspections, by type

…with no type recorded10
Years with a record 10 calendar years (1998–2010)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it44754 - Convention (Subpart B), Net Ton
149803 - Dead Weight, Ton
170428 - Displacement, Ton
81135 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

23 November 2010 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3894660
12 May 2009 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3473158
11 May 2009 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3472275
17 August 2008 ISPS II Exam · PII Safety Exam · COC-TVE Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3292686
30 July 2007 Ballast Water Examination · COC-TVE Renew · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3002305
6 June 2007 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2953418
21 September 2006 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2784192
5 July 2005 MARPOL Annex I Examination · Ballast Water Examination · COC-TVE Renew · ISPS III Exam · MARPOL Annex V Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2401983
28 July 2004 ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2148345
28 July 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2163425
23 June 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2127148
23 June 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2392588
14 June 2004 MARPOL Annex I Examination · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2097735
14 June 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2124974
14 June 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2392516
10 September 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1901881
17 June 2003 Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1820005
26 April 2003 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1796973
26 September 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 282591
21 January 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 411987
21 January 1998 Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 779036

Deficiency record · 8

Construction/Loadline › Hull › Hull Plating
Issued 21 September 2006 Resolved
CODE 2545: Hull inset, #2 WBT, approx. 4"X12"X12", was not reported to class society. 70A Vessel is due in DDX within 3 weeks.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Resolved 6 June 2007
Deck/Cargo › Crude Oil Washing Systems › Crude Oil Washing System Pump
Issued 21 September 2006 Resolved
CODE: 2545: Soft patch found on discharge side of piping for the tank washdown system, s/w supply pump. 70A Vessel is due in DDX in 3 weeks. Pin hole was not reported to class society
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 6 June 2007
Construction/Loadline › Structures › Door
Issued 21 September 2006 Resolved
1270 CODE: Fire screen doors on stair tower, 2nd dk, do not self latch. 70A
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 21 September 2006
Engineering › Fuel Oil Service System › Pump
Issued 5 July 2005 Resolved
Numerous pumps are leaking from packing glands and gaskets. Replace all leaking fuel pumps prior to next U.S. port to the satisfaction of class, pumps located in purifier room.
Action required: 15 - Rectify deficiencies by next port
Resolved 31 October 2005
Resolution: Received class report from DNV satisfying the requirement.
Engineering › Sea-water System (primary cooling) › Piping
Issued 5 July 2005 Resolved
Seawater cooling line on starboard side of engine foward of ladder adjacent to turbo has soft patch. Repair soft patch or replace to the satisfaction of class prior to next U.S. port.
Action required: 15 - Rectify deficiencies by next port
Resolved 31 October 2005
Resolution: Received class report from DNV satisfying the requirement.
Navigation › Collision/Grounding Avoidance › Radar
Issued 28 July 2004 Resolved
Inop Radar
Condition: Unknown
Due 28 July 2004
Resolved 28 July 2004
Resolution: Inop radar inspected and tested to the satisfaction of repair technition.
Engineering › Freshwater Generation System › Piping
Issued 14 June 2004 Resolved
Make permanent repairs to failed pipeing at freshwater generator. To the satisfaction to flag or class.
Action required: 705 - Other - as specified
Due 14 July 2004
Resolved 29 July 2004
Resolution: MSO PHILADELPHIA RECIEVED A COPY OF CLASS SURVEY STATING THAT PROPER REPAIRS WERE MADE.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 14 June 2004 Resolved
Make permanent repairs to failed gasket on #1 Turbo hot side. To the satisfaction of flag or class.
Action required: 705 - Other - as specified
Due 21 June 2004
Resolved 29 July 2004
Resolution: MSO PHILADELPHI RECIEVED A COPY OF CLASS SURVEY STATING THAT THE GASKET ON #1 TURBO HOT SIDE HAS BEEN REPLACED.

Ownership record