ISLAND EXPLORER 3

Built
1994
Last inspected
15 May 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 May 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL7058
404712
Flag
UNITED STATES
Maury page id
psix-404712

Documentation record

Registered dimensions (L × B × D)76.7 ft × 24.0 ft × 9.6 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)76.7 ft × 24.0 ft × 9.6 ft
ITC tonnagegross 131 / net 67
BuilderNETWORK MARINE, INC. · PIERRE PART, LA, UNITED STATES · built 1994
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLONG BEACH, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 6 June 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it131 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
67 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 25 inspections, each with its date, unit and type; 20 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 25

15 May 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8046369
22 January 2025 Drydock Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8066947
20 June 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7873861
14 February 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7847867
16 October 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7809296
13 October 2023 Type not recorded
No type recorded · Station Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7808181
20 July 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7673207
31 January 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7610154
27 January 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7628172
14 July 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7460723
15 March 2022 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7411656
13 August 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7285664
17 June 2021 Administrative Inspection · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7225571
9 February 2021 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7138129
2 February 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7134553
30 September 2020 Internal Structural Exam · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7067312
23 July 2020 Administrative Inspection · Deadweight Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7029608
19 July 2019 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6727937
1 February 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6618759
11 January 2019 DAPI Audit · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6609119
8 January 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6602872
8 March 2018 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6368582
6 March 2017 Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6100067
9 January 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6066686
29 March 2016 Internal Structural Exam · DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5842375

Deficiency record · 20

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 May 2025 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. MI observed hole at bilge suction foot. 46 CFR 119.520(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 30 May 2025
Resolution: Received pictures of welded and sealed bilge suction foot.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 May 2025 Resolved
Except for continuously manned operating stations as allowed by paragraph (f) of this section, each accommodation space, control space, and service space must be fitted with the following systems:(1) A smoke actuated fire detection system of a type approved by the Commandant that is installed in accordance with 46 CFR part 76. MI observed missing smoke detector from the galley. 46 CFR 118.400(f)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 27 May 2025
Resolution: Received picture from vessel operator of missing smoke detector in galley space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to:(b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI observed exposed wiring behind pilothouse console. 46 CFR 120.200(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 30 May 2025
Resolution: Received pictures of capped exposed wiring behind pilothouse console.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 May 2025 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. MI observed two holes on the aft deck above the lazarette space that can compromise downflooding in space. 46 CFR 116.100(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 27 May 2025
Resolution: Received picture from vessel operator of sealed holes on deck above lazarette space.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 January 2025 Resolved
Remove or repair rotted/holed pipe on starboard upper side of transom.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2025
Resolved 21 February 2025
Resolution: Pipe removed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 22 January 2025 Resolved
Noted 3 cracked welds on rails. Grind to good metal and make repairs to rails.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2025
Resolved 21 February 2025
Resolution: Rails repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 January 2025 Resolved
Port side bilge flange overboard damaged. Make repairs to flange.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2025
Resolved 21 February 2025
Resolution: Flange repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 22 January 2025 Resolved
Numerous pitts and clad welds in spaces. Create and continue program to accurately track pitting and clad weld size and location in dry stores, engine room and lazerette.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2025
Resolved 21 February 2025
Resolution: Tracking of pittting completed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 June 2024 Resolved
Waste Receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Vessel has several combustible trash cans. 46 CFR 116.405 (i)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2024
Resolved 1 July 2024
Resolution: Combustible waste receptacles have been removed from vessel.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 20 June 2024 Resolved
For vessels other than those covered in paragraphs (b) and (c) of this section, the name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Vessel's name on port and stbd bow is missing the number three. Vessel's hailing port is missing from the stern. 46 CFR 67.123 (a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2024
Resolved 1 July 2024
Resolution: Vessel's hailing port and name have been corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 20 June 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Vessel's refrigerator and house battery are not secured for sea. 46 CFR 115.830 (a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2024
Resolved 1 July 2024
Resolution: Vessel's house battery and refrigerator have been secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 June 2024 Resolved
Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. It shall be gas tight throughout its length and shall be properly supported by noncombustible hangers or blocks. Stbd side exhaust pipe in lazarette is corroded. 46 CFR 182.15-20 (a)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2024
Resolved 22 July 2024
Resolution: Vessel utilized a non metallic hose that is rated for wet exhaust systems with double band clamps at each end securing it to the aluminum pipes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 October 2023 Resolved
All vessels except non-self propelled vessels shall be provided with suitable steering apparatus. Vessel self reported loss of propulsion while outbound the Port of LA. 46CFR 182.30-1
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2023
Resolution: Vessel provided proof of proper steering operation to an attending USCG Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 July 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to:Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Vessel has four light fixtures in engine room that are not properly wired safely within junction box.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2022
Resolved 18 July 2022
Resolution: Verified proper installations in junction boxes for all light fixtures in engine room
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 14 July 2022 Resolved
The following plans must be submitted to the Coast Guard for approval in accordance with § 50.20-5 and § 50.20-10 of this chapter: Design Verification and Periodic Safety test procedures. Vessel could not provide periodic safety test procedures required for propulsion control microprocessors.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2022
Resolved 15 August 2022
Resolution: Operator provided copy of required documents.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 February 2021 Resolved
A vessel that is exposed to salt water for more than three months in any twelve month period since the last examination must undergo a dry dock examination and internal structural examination at least once every two years. Vessel is over due for dry dock. Vessel is prohited from carrying passengers for hire until a dry dock and internal structural examination are complete.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2021
Resolved 11 February 2021
Resolution: Credited DDX/ISE
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 25 July 2019 Resolved
A SMALL PASSENGER VESSEL WITH A RADIOTELEPHONE STATION MUST CARRY A RADIO OPERATOR HOLDING MARINE RADIO OPERATOR'S PERMIT. 47CFR80.159(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2019
Resolved 16 September 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 July 2019 Resolved
ELECTRICAL EQUIPMENT MUST BE INSTALLED TO PROTECT PAX AND CREW FROM ELECTRICAL HAZARDS. MAKE REPAIRS TO THE MOTOR CONTROLLER AT THE BILGE PUMP. 46CFR185.200
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 25 July 2019
Resolution: VESSEL CREW WAS ABLE TO REPAIR DEFECTIVE SWITCH WITH INKIND PART. OPS TESTED SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 July 2019 Resolved
BILGE PIPING SYSTEM: EACH INDIVIDUAL BILGE SUCTION LINE SHALL BE PROVIDED WITH A STOP VALVE AT THE CONTROL POINT AND A CHECK VALVE AT SOME ACCESSIBLE POINT IN THE BILGE LINE. PROVIDE A CHECK VALVE IN ALL INDIVIDUAL BILGE SUCTION LINES. 46CRF182.510
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 25 July 2019
Resolved 16 September 2019
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 19 July 2019 Resolved
The owner or master shall instruct each crew member as to duties that are expected to be performed in an emergency. Conduct and record (log) train of all potential crew members in the location and use of all emergency equipment and procedures.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2019
Resolved 31 October 2019

Recorded names · 1

AMERICAN DREAM (2002–2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.