MAURY USCG vessel records Sign in
← All vessels

SEA BLASTER

SEA BLASTER is a 1994 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1995, most recently in January 2026, along with 71 deficiencies and 5 casualty investigations between 2002 and 2019.

Records from 1995 to 2026. Most recent: inspection, 28 January 2026.

Built
1994
Last inspected
28 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH6076
404766
Flag
UNITED STATES
367634420
Maury page id
psix-404766

Inspections, by type

…with no type recorded10
Years with a record 30 calendar years (1995–2026)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.7 ft × 19.7 ft × 6.0 ft
Registered tonnagegross 51 / net 40
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAQUA BAY MARINE INC · PANAMA CITY, FL, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 April 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Simplified, Gross Ton
40 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH6076MMSI 367634420 · active · compulsorily equipped · granted 4 June 2024, expires 29 July 2034
WDB7958MMSI 366950510 · expired · compulsorily equipped · granted 22 May 2004, cancelled 26 July 2014
WCP9606MMSI not assigned · expired · compulsorily equipped · granted 14 February 1995, cancelled 16 April 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 65

28 January 2026 Administrative Inspection · Vessel Attendance · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8296960
11 March 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8091363
28 February 2024 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7872062
26 October 2023 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7814739
2 May 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7680463
10 April 2023 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7666141
6 March 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7646485
28 February 2022 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7403476
15 November 2021 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7354130
2 February 2021 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7135071
3 March 2020 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6919141
3 December 2019 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6874605
24 May 2019 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6745113
28 February 2019 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6634466
25 January 2018 Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6340354
7 December 2017 Administrative Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6315019
8 August 2017 Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6247140
3 August 2017 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6292260
23 March 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6105444
26 January 2016 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5800642
3 December 2015 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5774376
22 May 2014 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4906188
22 May 2012 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4318000
17 February 2012 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4246346
25 January 2012 Drydock Exam · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4230210
24 February 2011 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3951143
13 January 2010 Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3662611
4 June 2008 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3227594
7 May 2008 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3200313
18 March 2008 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3164041
3 January 2008 Internal Structural Exam · Examination of Repairs · Hull Examination · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3115158
22 May 2007 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2937010
27 February 2007 Type not recorded
No type recorded · Station Pensacola · USCG Heartland District (CGD-H) · Activity 2878895
12 July 2006 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2710722
25 June 2006 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2703821
31 January 2006 Deficiency Check · COI Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2576573
29 October 2005 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2582374
8 October 2005 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2526423
11 August 2005 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2458611
21 June 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2099505
30 March 2004 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2039374
24 March 2004 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2033085
19 June 2003 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1821831
14 May 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1793250
11 February 2003 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1740215
13 May 2002 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1616639
13 March 2002 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1494742
26 February 2002 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1493100
26 February 2002 Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1493305
11 June 2001 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1065317
1 March 2001 COI Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1362118
22 August 2000 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1516356
23 April 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1386852
27 August 1999 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1115270
27 August 1999 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1116457
10 June 1999 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1510042
13 April 1999 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1349446
30 March 1999 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1393204
23 February 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 782873
18 February 1998 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1114094
15 May 1997 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446566
4 February 1997 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1359346
9 July 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1089307
16 May 1996 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1442394
22 February 1995 Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1407520

Deficiency record · 71

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 November 2023 Resolved
Make permanent repairs to the forward, overhead beam in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 February 2024
Resolution: Repairs made.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 March 2023 Resolved
The inspected vessel is absent of the appropriate FCC documentation. Provide evidence of valid FCC Safety Radiotelephony Certificate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 10 April 2023
Resolution: Received evidence of valid FCC Safety Radiotelephony Certificate.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 March 2023 Resolved
A passenger accommodation space must be maintained to minimize fire and safety hazards and to preserve sanitary conditions. Both stanchions holding up each Restroom are in deteriorating condition, thus creating a potential safety hazard for passengers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 10 April 2023
Resolution: Recieved photographs of both corrected stanchions; satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 28 February 2022 Resolved
Visible oil leak noted from flexible hose fitting above breaker panel in space forward of engine room. Ensure hose fitting is free of leaks and remove excess oil.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 6 March 2023
Resolution: Verified fixed leaking from flexible hose fitting; satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 February 2022 Resolved
Installed rudder stops in way of tiller arm prevent full range of motion of steering ram. Ensure proper installation of rudder stops to allow for full range of motion of steering ram.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 6 March 2023
Resolution: Witnessed the satisfactory condition of the steering gear/ram; satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 28 February 2022 Resolved
Shutoff valve fitted in fuel supply lines at tank connection must be manually operable from outside of the compartment in which the valve is located. The handle on the starboard remote fuel shutoff valve located in the space forward of the engine room was severely wasted. Replace valve to ensure proper operation. 46 CFR 182.20-40(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 6 March 2023
Resolution: Witnessed the satisfactory operation of the starboard remote fuel shutoff valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 February 2022 Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. Excessive debris was noted in way of the forward bilge pump. Remove excess debris to ensure functionality of bilge pump. 46 CFR 182.25-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 6 March 2023
Resolution: Witnessed the satisfactory removal of debris in the way of the forward bilge pump.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 28 February 2022 Resolved
Owner or operator must be prepared to conduct tests of its fire protection equipment, including operation of the fire main system. A broken belt on the fire pump rendered the fire main inoperable. Install new belt to ensure proper operation of the system.
Action required: 10 - Deficiency Rectified
Due 28 February 2022
Resolved 28 February 2022
Resolution: Vessel representative provided video documentation showing operation of fire pump with adequate sea suction following installation of new belt.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 3 March 2020 Resolved
Sewage piping from port toilet to sewage collection tank has a small leak at the T connection. Sewage piping must not have leaks to prevent possible overboard discharge via bilge pump. Repair piping to make watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2020
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 3 March 2020 Resolved
Overboard sewage discharge valve is in the closed position, but has no lock on it for discharge prevention. Overboard sewage discharge valve must be padlocked in the closed position or the valve handle must be removed in the closed position or non-releasable wire-tie must be applied to hold the valve in the closed position.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2020
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 March 2020 Resolved
Visual indicator for aft high level alarm did not ignite. Repair alarm indicator so that visual indicator is ignited when high level alarm is activated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2020
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 3 March 2020 Resolved
Electric submersible bilge pump in V Berth did not activate when float switch was raised. Repair or replace so that float switch activates bilge pump as per original design.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2020
Electrical › Electrical Distribution System (service) › Switch
Issued 25 January 2018 Resolved
Replace electrial light switch cover plate near operating station.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 February 2018
Resolved 14 February 2018
Resolution: repairs conducted; all SAT.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 January 2018 Resolved
Secure wires in the fwd space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2018
Resolved 14 February 2018
Resolution: Repairs conducted; all SAT.
Construction/Loadline › Hull › Girder
Issued 25 January 2018 Resolved
Repair deck beam tabbing in FWD space and replace wasted fastiners in the deck beam tabbing in the FWD sapce.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2018
Resolved 14 February 2018
Resolution: Repairs conducted; all SAT.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 December 2017 Resolved
Renew broken seats for passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 25 January 2018
Resolution: Witnessed new seats.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 December 2017 Resolved
Stern ladder deck hand rail, repair or renew lower part of rail where holes have been rubbed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 25 January 2018
Resolution: Witness new rails.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 August 2017 Resolved
Replace port shaft
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2017
Resolved 14 August 2017
Resolution: Vesel replaced shaft
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 August 2017 Resolved
Remove stbd side prop and conduct dye penerant test of shaft aft of cutlass bearing and prop keyway.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2017
Resolved 14 August 2017
Resolution: Vessel conducted sat dye pen test.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 August 2017 Resolved
Conduct satisfactory underway vessel operation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2017
Resolved 17 August 2017
Resolution: Vessel conducted sat underway operation
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 22 May 2014 Resolved
Provide a current FCC safety radiotelephony certificate, Capt. shall maintain cell phone at all times while underway until a valid certificate is onboard.
Action required: 705 - Other - as specified
Due 3 June 2014
Resolved 1 July 2014
Resolution: Captain stated he had a FCC Lic.
Engineering › Steering Gear System › Rudder Stock
Issued 22 May 2014 Resolved
Repair the plate for the port side rudder stock prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2014
Navigation › Piloting/Steering › Magnetic Compass
Issued 22 May 2014 Resolved
Provide a light for the magnetic compass
Action required: 705 - Other - as specified
Due 3 June 2014
Resolved 3 July 2014
Resolution: Cleared to the satisfaction of Marine Inspector.
Stability › Watertight Integrity › General
Issued 13 January 2010 Resolved
Penetrations in collision bulkhead starboard side shall be made watertight as required by 46 CFR 179.310(a)(2) and 46 CFR 179.320(c) to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2010
Resolved 19 January 2010
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 13 January 2010 Resolved
Renew flexible non-metallic hose to fuel oil fill piping and install a conductor for protection against generation of a static charge when filling with fuel as required by 46 CFR 182.445(g) to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Due 27 January 2010
Resolved 19 January 2010
Engineering › Steering Gear System › Linkage
Issued 13 January 2010 Resolved
Repair steering gear connections to jockey bar/tiller arm connections as to prevent farther mechanical wear to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Due 27 January 2010
Resolved 19 January 2010
Resolution: Installed new bushings and found satisfactory
Accommodation/Occupational Safety › Potable Water System › General
Issued 13 January 2010 Resolved
Repair or renew PVC piping in way of potable water suction to tank connection to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 27 January 2010
Resolved 19 January 2010
Construction/Loadline › Structures › Cofferdam
Issued 13 January 2010 Resolved
Crop and renew deteriorated deck support framing port and starboard side stern compartment to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Due 27 January 2010
Resolved 19 January 2010
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 January 2010 Resolved
Tighten and or refasten all deck rail connections to the bulwark. Noted loose rail connections on starboard side bow, port side midships and aft deck swim platform. Repair shall be made to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Due 27 January 2010
Resolved 19 January 2010
Stability › Watertight Integrity › General
Issued 13 January 2010 Resolved
Prove tightness of weatherdeck in way of deck repairs by a means of a hose test of at least 30 psi in the presence of the attending marine inspector.
Due 27 January 2010
Resolved 19 January 2010
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 13 January 2010 Resolved
Install propellers to port and starboard shafts and make available for Coast Guard inspection.
Due 27 January 2010
Resolved 19 January 2010
Engineering › Fuel Oil Service System › Valve
Issued 7 May 2008 Resolved
Replace access hatch to emergency fuel shut off so that opening does not require a tool.
Action required: 705 - Other - as specified
Due 7 June 2008
Resolved 4 June 2008
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 May 2008 Resolved
Replace grab line on ring buoy.
Action required: 705 - Other - as specified
Due 7 June 2008
Resolved 4 June 2008
Documentation › Markings/Placards › Lifejacket Placard
Issued 7 May 2008 Resolved
Place additional life jacket donning placards about passenger area.
Action required: 705 - Other - as specified
Due 7 June 2008
Resolved 4 June 2008
Construction/Loadline › Structures › Machinery Space Opening
Issued 3 January 2008 Resolved
Make proper repairs the starboard engine room hatch cover.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2008
Resolved 7 February 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Air Cleaner
Issued 3 January 2008 Resolved
Provide the manufactures specifications for new and replacement engines.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2008
Resolved 7 February 2008
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 3 January 2008 Resolved
Provide shaft and strut specifications for new engine replacements including size, struts and torques.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 February 2008
Resolved 7 February 2008
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 28 February 2006 Resolved
Replace wasted retro reflective material on life jackets as required by 46 CFR 180.71.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 7 March 2006
Communications › Radio Communications › EPIRB
Issued 28 February 2006 Resolved
Install EPIRB in float-free arrangement as required by 46 CFR 185.728.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 7 March 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 February 2006 Resolved
Provide proper type of line on ring life buoy with buoyant line as required by 46 CFR 180.70.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 7 March 2006
Construction/Loadline › Hull › Hull Plating
Issued 31 January 2006 Resolved
Repair blisters on exterior hull as marked.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2006
Resolved 2 February 2006
Engineering › Bilge Water Management System › Pump
Issued 31 January 2006 Resolved
Permanently mount electric bilge pump in lazerette and provide junction box for electrical connections as required by 46 CFR 182.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2006
Resolved 2 February 2006
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 28 January 2006 Resolved
Repair/replace port shaft.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2006
Resolved 2 February 2006
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 11 August 2005 Resolved
Provide FCC Marine Radio operator License 47CFR180.155
Action required: 705 - Other - as specified
Due 11 September 2005
Resolved 1 November 2005
Resolution: Provided proof and a copy of current FCC Marine Radio Operator License
Fire Fighting › Fire Pumps › Casing
Issued 21 June 2004 Resolved
Tighten bolts on the face plate of the propulsion driven fire pump to discontinue leak 46 CFR 181.10(d) (1995).
Due 21 July 2004
Resolved 21 June 2004
Resolution: Bolts were tightened to discontine leak from pump housing.
Engineering › Steering Gear System › Rudder
Issued 21 June 2004 Resolved
Tighten the rudder packing on the starboard rudder to stop excessive flow of water per 46 CFR 182.30-1(1995).
Due 21 July 2004
Resolved 21 June 2004
Resolution: Starboard rudder packing was tightened and found satisfactory.
Construction/Loadline › Hull
Issued 24 March 2004 Resolved
Repair 9 blisters port & stbd hull 12 to 1 ratio, as identified IWO bow 4 to 6 ft aft of stem. LEGACY COMPONENT DESC: Bottom Plating
Action required: 705 - Other - as specified
Due 24 April 2004
Resolved 30 March 2004
Resolution: Owner repaired 9 blisters on hull.
Construction/Loadline › Hull
Issued 24 March 2004 Resolved
Repair tabs in fwd storage space 1st frame port and stbd at blkhd LEGACY COMPONENT DESC: Tabs
Action required: 705 - Other - as specified
Due 24 April 2004
Resolved 30 March 2004
Resolution: Owner repaired tabs.
Electrical › Electric Supply System (service)
Issued 24 March 2004 Resolved
Remove dead end cable in fwd storage area LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 24 April 2004
Resolved 30 March 2004
Resolution: Owner removed dead end cable
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 24 March 2004 Resolved
Have fixed fire fighting system serviced LEGACY COMPONENT DESC: Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2004
Resolution: Owner had Fixed Fire Fighting system serviced
Stability › Watertight Integrity
Issued 24 March 2004 Resolved
Renew gaskets on all watertight hatches LEGACY COMPONENT DESC: Hatches
Action required: 705 - Other - as specified
Due 24 April 2004
Resolved 30 March 2004
Resolution: Owner renewed gaskets on all hatches
Engineering › Steering Gear System
Issued 24 March 2004 Resolved
Repack port and stbd rudder tubes LEGACY COMPONENT DESC: Rudder
Action required: 705 - Other - as specified
Due 24 April 2004
Resolved 30 March 2004
Resolution: Owner repacked port and stbd rudder tubes
Engineering › Shafting/Propeller Arrangements
Issued 24 March 2004 Resolved
Renew stbd strut bearing LEGACY COMPONENT DESC: Strut Bearing
Action required: 705 - Other - as specified
Due 24 April 2004
Resolved 30 March 2004
Resolution: Owner renewedstbd strut bearing
Navigation › Piloting/Steering
Issued 14 May 2003 Resolved
Provide chart and publications as required by 46 CFR 184.420. LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Due 14 June 2003
Resolved 19 June 2003
Resolution: Owner provided up to date charts and publications.
Accommodation/Occupational Safety › Medical/First Aid
Issued 14 May 2003 Resolved
Provide First Aid Kit as required by 46 CFR 184.710. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 14 June 2003
Resolved 19 June 2003
Resolution: Owner provided approved first aid kit.
Electrical › Electric Supply System (service)
Issued 26 February 2002 Resolved
Prior to carrying passenger, make proper repairs of all wiring and associated electrical equipment damaged by fire on 26FEB02. LEGACY COMPONENT DESC: Battery Charger
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 March 2002
Resolution: Owner operator installed new electrical distribution box all associated machinery tested satisfactory. returned COI.
Documentation
Issued 23 April 2000 Resolved
46 CFR 67.7 / 33 CFR 173.25 - CONTACT THE VESSEL DOCUMENTATION OFFICE AND MAKE THE PROPER NAME CHANGE FOR THE VESSEL.
Condition: Unknown
Due 23 April 2000
Resolved 9 August 2000
Lifesaving
Issued 23 April 2000 Resolved
46 CFR 180.64 - REGISTER EPIRB WITH NOAA AND CONDUCT REQUIRED MONTHLY TESTSAND RECORD TEST RESULTS.
Condition: Unknown
Due 23 April 2000
Resolved 9 August 2000
Documentation
Issued 23 April 2000 Resolved
47 CFR 80.903 - RENEW VESSEL'S FCC STATION LICENSE.
Condition: Unknown
Due 23 April 2000
Resolved 9 August 2000
Construction/Loadline
Issued 23 April 2000 Resolved
46 CFR 177 - HAVE VESSEL DRYDOCKED FOR FURTHER INSPECTION OF WATER LEAK AT STARBOARD RUDDER POST.
Condition: Unknown
Due 23 April 2000
Resolved 9 August 2000
Lifesaving
Issued 23 April 2000 Resolved
46 CFR 185.604 - PROPERLY INSTALL REQUIRED RETRO-TAPE ON PFDS.
Condition: Unknown
Due 23 April 2000
Resolved 9 August 2000
Lifesaving
Issued 18 February 1998 Resolved
Provide 3 additional orange smoke flares.
Condition: Unknown
Due 25 February 1998
Resolved 24 February 1998
Lifesaving
Issued 18 February 1998 Resolved
Affix retro-reflective tape to ring buoy.
Condition: Unknown
Due 25 February 1998
Resolved 24 February 1998
Lifesaving
Issued 18 February 1998 Resolved
Provide proof of registration of EPIRB.
Condition: Unknown
Due 25 February 1998
Resolved 24 February 1998
Lifesaving
Issued 15 May 1997 Resolved
PROVIDE FOR VESSEL A 406MHz, CATAGORY 1 EMERGENCY POSITION RADIO INDICATINGBEACON AS REQUIRED BY 46 CFR 180.64. VSL IS RESTRICTED FROM OPERATION MORETHAN 3 NAUTICAL MILES FROM SHORE UNTIL INSTALLED AND REGISTERD WITH NOAA.
Condition: Unknown
Due 1 June 1997
Resolved 8 December 1997
Accommodation/Occupational Safety
Issued 16 May 1996 Resolved
COMPLETE REPAIRS TO FIRST FORWARD FIXED SEAT ON STBD SIDE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 16 June 1996
Resolved 14 July 1996
Navigation
Issued 16 May 1996 Resolved
PROVIDE MOUNTING HARDWARE FOR VESSELS BELL.
Condition: Unknown
Due 16 June 1996
Resolved 14 July 1996
Lifesaving
Issued 16 May 1996 Resolved
COMPLETE REPAIRS TO RING LIFEBOUY AND ATTACH WATER LIGHT TO RING LIFEBOUY.
Condition: Unknown
Due 16 June 1996
Resolved 14 July 1996
Documentation
Issued 16 May 1996 Resolved
PROVIDE DOCUMENTATION THAT VESSELS OPERATOR PROVIDE A EMPLOYEES ASSISTANCE PROGRAM IAW 46CFR16.401 FOR VESSELS CREW.
Condition: Unknown
Due 16 June 1996
Resolved 14 July 1996
Accommodation/Occupational Safety
Issued 16 May 1996 Resolved
TIGHTEN ALL MOUNTING HARDWARE ATTACHING FIXED SEATING TO VESSEL.
Condition: Unknown
Due 16 June 1996
Resolved 14 July 1996
Construction/Loadline
Issued 16 May 1996 Resolved
OPEN AFT PEAK COMPARTMENTS FOR INSPECTION.
Condition: Unknown
Due 16 June 1996
Resolved 14 July 1996

Casualty record · 5

26 February 2002Routine · role: Involved in a Marine Casualty · activity 1493100
25 June 2006Routine · role: Involved in a Marine Casualty · activity 2703821
23 June 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4054588
3 August 2017Routine · role: Involved in a Marine Casualty · activity 6292260
24 May 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6745113
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.