← All vessels
SEA BLASTER
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Heartland District (CGD-H) · Other hulls named SEA BLASTER
SEA BLASTER is a 1994 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1995, most recently in January 2026, along with 71 deficiencies and 5 casualty investigations between 2002 and 2019.
Records from 1995 to 2026. Most recent: inspection, 28 January 2026.
- Built
- 1994
- Last inspected
- 28 January 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 71 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 5 investigations · 2002–2019
Identity
1021718
WDH6076
404766
Flag
UNITED STATES
367634420
Maury page id
psix-404766
Inspections, by type
…with no type recorded10
Years with a record
30 calendar years (1995–2026)
The 65 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)64.7 ft × 19.7 ft × 6.0 ft
Registered tonnagegross 51 / net 40
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAQUA BAY MARINE INC · PANAMA CITY, FL, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 April 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Simplified, Gross Ton
40 - Simplified, Net Ton
40 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDH6076MMSI 367634420 · active · compulsorily equipped · granted 4 June 2024, expires 29 July 2034
WDB7958MMSI 366950510 · expired · compulsorily equipped · granted 22 May 2004, cancelled 26 July 2014
WCP9606MMSI not assigned · expired · compulsorily equipped · granted 14 February 1995, cancelled 16 April 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 65
28 January 2026
Administrative Inspection · Vessel Attendance · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8296960
11 March 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8091363
28 February 2024
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7872062
26 October 2023
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7814739
2 May 2023
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7680463
10 April 2023
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7666141
6 March 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7646485
28 February 2022
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7403476
15 November 2021
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7354130
2 February 2021
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7135071
3 March 2020
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6919141
3 December 2019
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6874605
24 May 2019
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6745113
28 February 2019
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6634466
25 January 2018
Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6340354
7 December 2017
Administrative Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6315019
8 August 2017
Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6247140
3 August 2017
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6292260
23 March 2017
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6105444
26 January 2016
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5800642
3 December 2015
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5774376
22 May 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4906188
22 May 2012
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4318000
17 February 2012
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4246346
25 January 2012
Drydock Exam · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4230210
24 February 2011
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3951143
13 January 2010
Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3662611
4 June 2008
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3227594
7 May 2008
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3200313
18 March 2008
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3164041
3 January 2008
Internal Structural Exam · Examination of Repairs · Hull Examination · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3115158
22 May 2007
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2937010
27 February 2007
Type not recorded
No type recorded · Station Pensacola · USCG Heartland District (CGD-H) · Activity 2878895
12 July 2006
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2710722
25 June 2006
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2703821
31 January 2006
Deficiency Check · COI Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2576573
29 October 2005
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2582374
8 October 2005
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2526423
11 August 2005
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2458611
21 June 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2099505
30 March 2004
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2039374
24 March 2004
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2033085
19 June 2003
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1821831
14 May 2003
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1793250
11 February 2003
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1740215
13 May 2002
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1616639
13 March 2002
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1494742
26 February 2002
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1493100
26 February 2002
Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1493305
11 June 2001
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1065317
1 March 2001
COI Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1362118
22 August 2000
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1516356
23 April 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1386852
27 August 1999
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1115270
27 August 1999
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1116457
10 June 1999
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1510042
13 April 1999
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1349446
30 March 1999
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1393204
23 February 1998
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 782873
18 February 1998
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1114094
15 May 1997
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446566
4 February 1997
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1359346
9 July 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1089307
16 May 1996
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1442394
22 February 1995
Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1407520
Deficiency record · 71
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 November 2023
Resolved
Make permanent repairs to the forward, overhead beam in the engine room.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 March 2023
Resolved
The inspected vessel is absent of the appropriate FCC documentation. Provide evidence of valid FCC Safety Radiotelephony Certificate.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 March 2023
Resolved
A passenger accommodation space must be maintained to minimize fire and safety hazards and to preserve sanitary conditions. Both stanchions holding up each Restroom are in deteriorating condition, thus creating a potential safety hazard for passengers.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 28 February 2022
Resolved
Visible oil leak noted from flexible hose fitting above breaker panel in space forward of engine room. Ensure hose fitting is free of leaks and remove excess oil.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 February 2022
Resolved
Installed rudder stops in way of tiller arm prevent full range of motion of steering ram. Ensure proper installation of rudder stops to allow for full range of motion of steering ram.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 28 February 2022
Resolved
Shutoff valve fitted in fuel supply lines at tank connection must be manually operable from outside of the compartment in which the valve is located. The handle on the starboard remote fuel shutoff valve located in the space forward of the engine room was severely wasted. Replace valve to ensure proper operation. 46 CFR 182.20-40(b)(3)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 February 2022
Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. Excessive debris was noted in way of the forward bilge pump. Remove excess debris to ensure functionality of bilge pump.
46 CFR 182.25-1
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 28 February 2022
Resolved
Owner or operator must be prepared to conduct tests of its fire protection equipment, including operation of the fire main system. A broken belt on the fire pump rendered the fire main inoperable. Install new belt to ensure proper operation of the system.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 3 March 2020
Resolved
Sewage piping from port toilet to sewage collection tank has a small leak at the T connection. Sewage piping must not have leaks to prevent possible overboard discharge via bilge pump. Repair piping to make watertight.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 3 March 2020
Resolved
Overboard sewage discharge valve is in the closed position, but has no lock on it for discharge prevention. Overboard sewage discharge valve must be padlocked in the closed position or the valve handle must be removed in the closed position or non-releasable wire-tie must be applied to hold the valve in the closed position.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 March 2020
Resolved
Visual indicator for aft high level alarm did not ignite. Repair alarm indicator so that visual indicator is ignited when high level alarm is activated.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 3 March 2020
Resolved
Electric submersible bilge pump in V Berth did not activate when float switch was raised. Repair or replace so that float switch activates bilge pump as per original design.
Electrical › Electrical Distribution System (service) › Switch
Issued 25 January 2018
Resolved
Replace electrial light switch cover plate near operating station.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 January 2018
Resolved
Secure wires in the fwd space.
Construction/Loadline › Hull › Girder
Issued 25 January 2018
Resolved
Repair deck beam tabbing in FWD space and replace wasted fastiners in the deck beam tabbing in the FWD sapce.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 December 2017
Resolved
Renew broken seats for passengers.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 December 2017
Resolved
Stern ladder deck hand rail, repair or renew lower part of rail where holes have been rubbed.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 August 2017
Resolved
Replace port shaft
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 August 2017
Resolved
Remove stbd side prop and conduct dye penerant test of shaft aft of cutlass bearing and prop keyway.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 August 2017
Resolved
Conduct satisfactory underway vessel operation
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 22 May 2014
Resolved
Provide a current FCC safety radiotelephony certificate, Capt. shall maintain cell phone at all times while underway until a valid certificate is onboard.
Engineering › Steering Gear System › Rudder Stock
Issued 22 May 2014
Resolved
Repair the plate for the port side rudder stock prior to carrying passengers for hire.
Navigation › Piloting/Steering › Magnetic Compass
Issued 22 May 2014
Resolved
Provide a light for the magnetic compass
Stability › Watertight Integrity › General
Issued 13 January 2010
Resolved
Penetrations in collision bulkhead starboard side shall be made watertight as required by 46 CFR 179.310(a)(2) and 46 CFR 179.320(c) to the satisfaction of the attending marine inspector.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 13 January 2010
Resolved
Renew flexible non-metallic hose to fuel oil fill piping and install a conductor for protection against generation of a static charge when filling with fuel as required by 46 CFR 182.445(g) to the satisfaction of the attending marine inspector.
Engineering › Steering Gear System › Linkage
Issued 13 January 2010
Resolved
Repair steering gear connections to jockey bar/tiller arm connections as to prevent farther mechanical wear to the satisfaction of the attending marine inspector.
Accommodation/Occupational Safety › Potable Water System › General
Issued 13 January 2010
Resolved
Repair or renew PVC piping in way of potable water suction to tank connection to the satisfaction of the attending marine inspector.
Construction/Loadline › Structures › Cofferdam
Issued 13 January 2010
Resolved
Crop and renew deteriorated deck support framing port and starboard side stern compartment to the satisfaction of the attending marine inspector.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 January 2010
Resolved
Tighten and or refasten all deck rail connections to the bulwark. Noted loose rail connections on starboard side bow, port side midships and aft deck swim platform. Repair shall be made to the satisfaction of the attending marine inspector.
Stability › Watertight Integrity › General
Issued 13 January 2010
Resolved
Prove tightness of weatherdeck in way of deck repairs by a means of a hose test of at least 30 psi in the presence of the attending marine inspector.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 13 January 2010
Resolved
Install propellers to port and starboard shafts and make available for Coast Guard inspection.
Engineering › Fuel Oil Service System › Valve
Issued 7 May 2008
Resolved
Replace access hatch to emergency fuel shut off so that opening does not require a tool.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 May 2008
Resolved
Replace grab line on ring buoy.
Documentation › Markings/Placards › Lifejacket Placard
Issued 7 May 2008
Resolved
Place additional life jacket donning placards about passenger area.
Construction/Loadline › Structures › Machinery Space Opening
Issued 3 January 2008
Resolved
Make proper repairs the starboard engine room hatch cover.
Engineering › Diesel Engine (propulsion-reduction gear) › Air Cleaner
Issued 3 January 2008
Resolved
Provide the manufactures specifications for new and replacement engines.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 3 January 2008
Resolved
Provide shaft and strut specifications for new engine replacements including size, struts and torques.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 28 February 2006
Resolved
Replace wasted retro reflective material on life jackets as required by 46 CFR 180.71.
Communications › Radio Communications › EPIRB
Issued 28 February 2006
Resolved
Install EPIRB in float-free arrangement as required by 46 CFR 185.728.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 February 2006
Resolved
Provide proper type of line on ring life buoy with buoyant line as required by 46 CFR 180.70.
Construction/Loadline › Hull › Hull Plating
Issued 31 January 2006
Resolved
Repair blisters on exterior hull as marked.
Engineering › Bilge Water Management System › Pump
Issued 31 January 2006
Resolved
Permanently mount electric bilge pump in lazerette and provide junction box for electrical connections as required by
46 CFR 182.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 28 January 2006
Resolved
Repair/replace port shaft.
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 11 August 2005
Resolved
Provide FCC Marine Radio operator License 47CFR180.155
Fire Fighting › Fire Pumps › Casing
Issued 21 June 2004
Resolved
Tighten bolts on the face plate of the propulsion driven fire pump to discontinue leak 46 CFR 181.10(d) (1995).
Engineering › Steering Gear System › Rudder
Issued 21 June 2004
Resolved
Tighten the rudder packing on the starboard rudder to stop excessive flow of water per 46 CFR 182.30-1(1995).
Construction/Loadline › Hull
Issued 24 March 2004
Resolved
Repair 9 blisters port & stbd hull 12 to 1 ratio, as identified IWO bow 4 to 6 ft aft of stem. LEGACY COMPONENT DESC: Bottom Plating
Construction/Loadline › Hull
Issued 24 March 2004
Resolved
Repair tabs in fwd storage space 1st frame port and stbd at blkhd LEGACY COMPONENT DESC: Tabs
Electrical › Electric Supply System (service)
Issued 24 March 2004
Resolved
Remove dead end cable in fwd storage area LEGACY COMPONENT DESC: Cable
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 24 March 2004
Resolved
Have fixed fire fighting system serviced LEGACY COMPONENT DESC: Service
Stability › Watertight Integrity
Issued 24 March 2004
Resolved
Renew gaskets on all watertight hatches LEGACY COMPONENT DESC: Hatches
Engineering › Steering Gear System
Issued 24 March 2004
Resolved
Repack port and stbd rudder tubes LEGACY COMPONENT DESC: Rudder
Engineering › Shafting/Propeller Arrangements
Issued 24 March 2004
Resolved
Renew stbd strut bearing LEGACY COMPONENT DESC: Strut Bearing
Navigation › Piloting/Steering
Issued 14 May 2003
Resolved
Provide chart and publications as required by 46 CFR 184.420. LEGACY COMPONENT DESC: Marine Charts
Accommodation/Occupational Safety › Medical/First Aid
Issued 14 May 2003
Resolved
Provide First Aid Kit as required by 46 CFR 184.710. LEGACY COMPONENT DESC: Medicine Chest
Electrical › Electric Supply System (service)
Issued 26 February 2002
Resolved
Prior to carrying passenger, make proper repairs of all wiring and associated electrical equipment damaged by fire on 26FEB02. LEGACY COMPONENT DESC: Battery Charger
Documentation
Issued 23 April 2000
Resolved
46 CFR 67.7 / 33 CFR 173.25 - CONTACT THE VESSEL DOCUMENTATION OFFICE AND MAKE THE PROPER NAME CHANGE FOR THE VESSEL.
Lifesaving
Issued 23 April 2000
Resolved
46 CFR 180.64 - REGISTER EPIRB WITH NOAA AND CONDUCT REQUIRED MONTHLY TESTSAND RECORD TEST RESULTS.
Documentation
Issued 23 April 2000
Resolved
47 CFR 80.903 - RENEW VESSEL'S FCC STATION LICENSE.
Construction/Loadline
Issued 23 April 2000
Resolved
46 CFR 177 - HAVE VESSEL DRYDOCKED FOR FURTHER INSPECTION OF WATER LEAK AT STARBOARD RUDDER POST.
Lifesaving
Issued 23 April 2000
Resolved
46 CFR 185.604 - PROPERLY INSTALL REQUIRED RETRO-TAPE ON PFDS.
Lifesaving
Issued 18 February 1998
Resolved
Provide 3 additional orange smoke flares.
Lifesaving
Issued 18 February 1998
Resolved
Affix retro-reflective tape to ring buoy.
Lifesaving
Issued 18 February 1998
Resolved
Provide proof of registration of EPIRB.
Lifesaving
Issued 15 May 1997
Resolved
PROVIDE FOR VESSEL A 406MHz, CATAGORY 1 EMERGENCY POSITION RADIO INDICATINGBEACON AS REQUIRED BY 46 CFR 180.64. VSL IS RESTRICTED FROM OPERATION MORETHAN 3 NAUTICAL MILES FROM SHORE UNTIL INSTALLED AND REGISTERD WITH NOAA.
Accommodation/Occupational Safety
Issued 16 May 1996
Resolved
COMPLETE REPAIRS TO FIRST FORWARD FIXED SEAT ON STBD SIDE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Navigation
Issued 16 May 1996
Resolved
PROVIDE MOUNTING HARDWARE FOR VESSELS BELL.
Lifesaving
Issued 16 May 1996
Resolved
COMPLETE REPAIRS TO RING LIFEBOUY AND ATTACH WATER LIGHT TO RING LIFEBOUY.
Documentation
Issued 16 May 1996
Resolved
PROVIDE DOCUMENTATION THAT VESSELS OPERATOR PROVIDE A EMPLOYEES ASSISTANCE PROGRAM IAW 46CFR16.401 FOR VESSELS CREW.
Accommodation/Occupational Safety
Issued 16 May 1996
Resolved
TIGHTEN ALL MOUNTING HARDWARE ATTACHING FIXED SEATING TO VESSEL.
Construction/Loadline
Issued 16 May 1996
Resolved
OPEN AFT PEAK COMPARTMENTS FOR INSPECTION.
Casualty record · 5
26 February 2002Routine · role: Involved in a Marine Casualty · activity 1493100
25 June 2006Routine · role: Involved in a Marine Casualty · activity 2703821
23 June 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4054588
3 August 2017Routine · role: Involved in a Marine Casualty · activity 6292260
24 May 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6745113
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.