Records from 2002 to 2026. Most recent: inspection, 28 January 2026.
Documentation record
Registered dimensions (L × B × D)64.7 ft × 19.7 ft × 6.0 ft
Registered tonnagegross 51 / net 40
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAQUA BAY MARINE INC · PANAMA CITY, FL, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 April 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Simplified, Gross Ton
40 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
28 January 2026
Administrative Inspection · Vessel Attendance · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8296960
11 March 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8091363
28 February 2024
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7872062
26 October 2023
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7814739
2 May 2023
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7680463
10 April 2023
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7666141
6 March 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7646485
28 February 2022
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7403476
15 November 2021
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7354130
2 February 2021
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7135071
3 March 2020
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6919141
3 December 2019
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6874605
24 May 2019
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6745113
28 February 2019
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6634466
25 January 2018
Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6340354
7 December 2017
Administrative Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6315019
8 August 2017
Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6247140
3 August 2017
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6292260
23 March 2017
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6105444
26 January 2016
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5800642
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 November 2023
Resolved
Make permanent repairs to the forward, overhead beam in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 February 2024
Resolution: Repairs made.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 March 2023
Resolved
The inspected vessel is absent of the appropriate FCC documentation. Provide evidence of valid FCC Safety Radiotelephony Certificate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 10 April 2023
Resolution: Received evidence of valid FCC Safety Radiotelephony Certificate.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 March 2023
Resolved
A passenger accommodation space must be maintained to minimize fire and safety hazards and to preserve sanitary conditions. Both stanchions holding up each Restroom are in deteriorating condition, thus creating a potential safety hazard for passengers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 10 April 2023
Resolution: Recieved photographs of both corrected stanchions; satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 28 February 2022
Resolved
Visible oil leak noted from flexible hose fitting above breaker panel in space forward of engine room. Ensure hose fitting is free of leaks and remove excess oil.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 6 March 2023
Resolution: Verified fixed leaking from flexible hose fitting; satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 February 2022
Resolved
Installed rudder stops in way of tiller arm prevent full range of motion of steering ram. Ensure proper installation of rudder stops to allow for full range of motion of steering ram.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 6 March 2023
Resolution: Witnessed the satisfactory condition of the steering gear/ram; satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 28 February 2022
Resolved
Shutoff valve fitted in fuel supply lines at tank connection must be manually operable from outside of the compartment in which the valve is located. The handle on the starboard remote fuel shutoff valve located in the space forward of the engine room was severely wasted. Replace valve to ensure proper operation. 46 CFR 182.20-40(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 6 March 2023
Resolution: Witnessed the satisfactory operation of the starboard remote fuel shutoff valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 February 2022
Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. Excessive debris was noted in way of the forward bilge pump. Remove excess debris to ensure functionality of bilge pump.
46 CFR 182.25-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 6 March 2023
Resolution: Witnessed the satisfactory removal of debris in the way of the forward bilge pump.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 28 February 2022
Resolved
Owner or operator must be prepared to conduct tests of its fire protection equipment, including operation of the fire main system. A broken belt on the fire pump rendered the fire main inoperable. Install new belt to ensure proper operation of the system.
Action required: 10 - Deficiency Rectified
Due 28 February 2022
Resolved 28 February 2022
Resolution: Vessel representative provided video documentation showing operation of fire pump with adequate sea suction following installation of new belt.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 3 March 2020
Resolved
Sewage piping from port toilet to sewage collection tank has a small leak at the T connection. Sewage piping must not have leaks to prevent possible overboard discharge via bilge pump. Repair piping to make watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2020
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 3 March 2020
Resolved
Overboard sewage discharge valve is in the closed position, but has no lock on it for discharge prevention. Overboard sewage discharge valve must be padlocked in the closed position or the valve handle must be removed in the closed position or non-releasable wire-tie must be applied to hold the valve in the closed position.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2020
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 March 2020
Resolved
Visual indicator for aft high level alarm did not ignite. Repair alarm indicator so that visual indicator is ignited when high level alarm is activated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2020
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 3 March 2020
Resolved
Electric submersible bilge pump in V Berth did not activate when float switch was raised. Repair or replace so that float switch activates bilge pump as per original design.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2020
Electrical › Electrical Distribution System (service) › Switch
Issued 25 January 2018
Resolved
Replace electrial light switch cover plate near operating station.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 February 2018
Resolved 14 February 2018
Resolution: repairs conducted; all SAT.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 January 2018
Resolved
Secure wires in the fwd space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2018
Resolved 14 February 2018
Resolution: Repairs conducted; all SAT.
Construction/Loadline › Hull › Girder
Issued 25 January 2018
Resolved
Repair deck beam tabbing in FWD space and replace wasted fastiners in the deck beam tabbing in the FWD sapce.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2018
Resolved 14 February 2018
Resolution: Repairs conducted; all SAT.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 December 2017
Resolved
Renew broken seats for passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 25 January 2018
Resolution: Witnessed new seats.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 December 2017
Resolved
Stern ladder deck hand rail, repair or renew lower part of rail where holes have been rubbed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 25 January 2018
Resolution: Witness new rails.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 August 2017
Resolved
Replace port shaft
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2017
Resolved 14 August 2017
Resolution: Vesel replaced shaft
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 August 2017
Resolved
Remove stbd side prop and conduct dye penerant test of shaft aft of cutlass bearing and prop keyway.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2017
Resolved 14 August 2017
Resolution: Vessel conducted sat dye pen test.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 August 2017
Resolved
Conduct satisfactory underway vessel operation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2017
Resolved 17 August 2017
Resolution: Vessel conducted sat underway operation