MAURY USCG vessel records
← All vessels

GSL MARIA

GSL MARIA is a 2001 freight ship. The Coast Guard has recorded 24 inspections since 2017, most recently in May 2026, along with 8 deficiencies and 3 operational controls, 1 with no removal date recorded.

Records from 2017 to 2026. Most recent: inspection, 8 May 2026.

Built
2001
Last inspected
8 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 May 2026
…with no type recorded2
Operational controls 1 with no removal date recorded
Years with a record 10 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9231236
Flag
LIBERIA
Maury page id
psix-40493

Documentation record

Tonnage as PSIX records it37491 - Convention (Subpart B), Net Ton
71607 - Dead Weight, Metric Ton
96021 - Displacement, Metric Ton
65792 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

24 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 24

8 May 2026 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8369091
21 April 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8115953
2 April 2024 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7885977
16 August 2023 In-Service Inspection · PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7765879
15 August 2023 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7768758
28 May 2023 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7698236
25 May 2023 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7694935
14 December 2022 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7608915
6 December 2022 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7604783
2 June 2022 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7466717
24 May 2022 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7452856
17 May 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7453119
23 May 2021 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7204032
13 May 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7196292
24 March 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7162105
4 January 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6882740
3 January 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6882489
12 November 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6853606
20 May 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6689615
11 October 2018 ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6557284
1 March 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6364211
5 January 2018 NPV Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6331505
23 May 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6153101
1 April 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6114290

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 December 2022 Resolved
07126 - The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: Means shall be provided to control leaks of flammable liquids. PSCO observed excess amounts of oil around and below the ship’s no. 1 generator, including a blue tub filled with approximately 4 gallons of oil. 74SOLAS(20)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2022
Resolved 6 December 2022
Resolution: Vessel provided class documentation attesting to the rectification of the vessel fuel oil leak on the auxiliary generator.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 December 2022 Resolved
07105 - Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures other than power-operated watertight doors and those which are normally locked shall satisfy the following requirements: Hold-back hooks not subject to central control station release are prohibited. PSCO observed A-60 door to purifier room wedged open with wooden block. 74SOLAS(20)II-2/9.4.1.1.5.4
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 6 December 2022
Resolved 6 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 24 May 2022 Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensuring reliability of such appliances. PSCO observed STBD hydrostatic release for the life raft was expired. 74 SOLAS (20) III/20.3.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2022
Resolution: Received photographs of hydrostatic release and installation, both satisfactory.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 24 May 2022 Resolved
Every ship of 400GT and above, and every ship which is certified to carry 15 persons of more, shall carry a garbage management plan which the crew shall follow. This plan shall provide written procedures for collecting, storing, processing and disposing of garbage. PSCO observed garbage management plan was not being followed. Ships garbage and oily rags were not stored or disposed of in accordance with the ship's garbage management plan. Marpol V/9.2
Action required: 15 - Rectify deficiencies by next port
Resolved 2 June 2022
Resolution: Vessel submitted garbage management plan.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 23 May 2017 Resolved
1499-Propulsion & aux (other) Generator #1 had an active fuel leak from fuel pump. 74SOLAS(04)II-1/26.7 17 A C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2017
Resolution: Class attended vessel fuel leak has been repaired to satisfaction of class.
Lifesaving › Lifeboat › Propeller
Issued 23 May 2017 Resolved
0610-Lifeboats- Port lifeboat wheel is inoperable. The only way to control steering is use of the tiller which is not permanently installed. 74SOLAS (14) III/34 LSA Code 4.4.7.2 10c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2017
Navigation › Piloting/Steering › Swing Meter
Issued 23 May 2017 Resolved
1581-Rudder angle indicator- The rudder angle indicators located on the bridge wings are inaccurate compared to the wheelhouse. The starboard indicator is off 5 deg and the port indicator is off 8 deg from the main indicator. 74SOLAS(14)V/19.2.5.4- 17 A C
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 14 July 2017
Resolution: Vessel provided proper documentation and classification society report indiciating deficient item was repaired.
Fire Fighting › Structural - Horizontal Zones › General
Issued 23 May 2017 Resolved
799-Other (Firefighting) Self closing door in galley was blocked in the open position with a piece of wood. 74SOLAS(01)II-2/47.2- 10 c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2017

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.