MAURY USCG vessel records Sign in
← All vessels

DEFIANT

DEFIANT is a 2001 freight ship. The Coast Guard has recorded 18 inspections since 2001, most recently in June 2017, along with 1 deficiency and 2 operational controls.

Records from 2001 to 2017. Most recent: inspection, 8 June 2017.

Built
2001
Last inspected
8 June 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9251030 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
LIBERIA
—
Maury page id
psix-40497

Inspections, by type

…with no type recorded8
Years with a record 9 calendar years (2001–2017)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it18011 - Convention (Subpart B), Net Ton
60718 - Displacement, Ton
52478 - Dead Weight, Ton
29885 - Regulatory (Subpart C or D), Gross Ton
18011 - Regulatory (Subpart C or D), Net Ton
29885 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 18

8 June 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6167941
19 November 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3895146
19 November 2010 ISPS I Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3895378
25 June 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3247348
22 May 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2937167
21 May 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2937026
8 May 2007 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2924956
4 March 2006 Random ISPS/MTSA/PSC
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2595985
8 December 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2548666
7 December 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2547369
6 December 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2547368
1 June 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2376024
18 May 2005 PII Safety Exam · ISPS II Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2361399
16 May 2005 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2359485
21 May 2004 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2074253
6 April 2004 MARPOL Annex I Examination · Annual Inspection · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2038355
2 December 2002 MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1710704
26 December 2001 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1474091

Deficiency record · 1

Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 18 May 2005 Resolved
Vessel's emergency generator is not able to start with two seperate energey sources. The two banks of batteries fail to provide sufficent power independently to start the emergency generator . Vessel shall be able to have enough power in each bank of batteries to start the emergency generator.
Action required: 15 - Rectify deficiencies by next port
Due 21 May 2005
Resolved 24 May 2005
Resolution: Vessel master provided a letter attesting to the proper operation of the ship''''s emergency generator. Vessel replaced the batteries and provided the reciept for the batteries.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.