This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it1370 - Convention (Subpart B), Gross Ton 1370 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 August 2021Resolved
Doors fitted in boundry bulkheads of machinery spaces of category A shall be reasonably gastight & self closing. 03 doors missing gasket material from engine room and sesmic rooms.
74SOLAS(97)II-2/47.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2021
Resolved 25 August 2021
Resolution: Doors fitted in boundry bulkheads of machinery spaces of category A shall be reasonably gastight & self closing. Three doors
missing gasket material from engine room and sesmic rooms.
<Action taken>
: It was confirmed that gaskets were installed in 3 p
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 August 2021Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks mentioned elsewhere in this part, the minimum fire integrity of bulkheads and decks shall be as prescribed in tables 44.1 and 44.2.
74SOLAS(97)II-2/44.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2021
Resolved 25 August 2021
Resolution: <Action taken>
: It was confirmed that the four indicated bulkhead penetrations were sealed to a practicable level taking into account the fire
integrity of the bulkhead.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 19 August 2021Resolved
The absence or improper installation of built-in guards or other protective devices such as railings, fencing or shielding, for moving parts of mechanical and electrical machinery and equipment presenting hazards to personnel;
PWSA 46USC7002
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2021
Resolved 25 August 2021
Resolution: <Action taken>
: It was confirmed that the appropriate protection cover was installed in 4 points of mechanical and electrical machinery.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 19 August 2021Resolved
The structural condition and arrangement of the ship’s accommodation ladders, with particular attention to any unsafe situation with respect to stringers, handrails, threads, end-roller and suspension rigging. No handrails leading to dry store provision.
PWSA 46USC7002
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2021
Resolved 25 August 2021
Resolution: <Action taken>
: It was confirmed that the handrail is installed on the stair going down to dry stores provision.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.