Records from 2005 to 2026. Most recent: inspection, 14 May 2026.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2026
Resolved
Properly mount spanner wrenches at firefighting stations
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2026
Resolved 15 May 2026
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 14 May 2026
Resolved
Program Lat & Long in VHF Radio
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2026
Resolved 23 June 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2026
Resolved
Remount strainer on bilge line in forepeak
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2026
Resolved 15 May 2026
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 May 2026
Resolved
Remount fire damper on starboard side, as discussed
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2026
Resolved 15 May 2026
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 14 May 2026
Resolved
Properly mount retention chains on rudders
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2026
Resolved 15 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2026
Resolved
Properly label lifejacket storage lockers with amount and type of jackets
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2026
Resolved 15 May 2026
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 May 2026
Resolved
Properly install and test fixed integrated smoke detection systems.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2026
Resolved 15 May 2026
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 May 2024
Resolved
Need at least 48 doses of non-expired aspirin
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2024
Resolved 22 May 2024
Resolution: Purchased new aspirin.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 20 May 2024
Resolved
Repair the stanchion in way of the life float as discussed
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2024
Resolved 22 May 2024
Resolution: Stanchions repaired
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 May 2024
Resolved
Label the emergency escape hatch using 2” block letters stating “Keep Clear, Emergency Exit”
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2024
Resolved 22 May 2024
Resolution: Escape hatches labelled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 May 2024
Resolved
Renew lights on lifejackets as discussed
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2024
Resolved 22 May 2024
Resolution: lights were renewed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 May 2024
Resolved
Install the smoke detectors and ensure they are integrated with each other.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2024
Resolved 22 May 2024
Resolution: Smoke detectors were installed.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 13 October 2022
Resolved
Prove adequate berthing for crew.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 20 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 October 2022
Resolved
Provide approved smoke detection for passenger berth, adjoining Main Cabin and crew berthing space, Prior to approval to carry overnight passengers.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 20 May 2025
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 13 October 2022
Resolved
Provided a means to assist in egress from the emergency scuttle IAW 46CFR177.500(m).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 20 May 2025
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 13 October 2022
Resolved
Provide adequate markings/labeling to the satisfaction of an attending marine inspector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 20 May 2025
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 13 October 2022
Resolved
Provide approved mattresses for all berths to include crew overnight accommodations, Prior to approval to carry overnight passengers.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: Mattresses that have been provided are of the approved type. Several berths do not have mattresses and O/O stated passengers will utilized their own sleeping bag and not require mattress.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 29 June 2022
Resolved
Ensure all required drills are logged quarterly and recommended monthly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 11 August 2022
Resolution: Logged
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 June 2022
Resolved
Fire nozzle broken. Replace with a new one.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 11 August 2022
Resolution: Purchased and installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 June 2022
Resolved
Spanner wrenches were missing from fire connections. Replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 11 August 2022
Resolution: Purchased and installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 June 2022
Resolved
Replace port side fire main valve connection handle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 11 August 2022
Resolution: Repaired.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 June 2022
Resolved
MDE vents do not have a means of closing. Fabricate closures.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 11 August 2022
Resolution: Made out of wood and permanantly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2022
Resolved
Reapir water leak in center MDE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 11 August 2022
Resolution: Repaired
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 June 2022
Resolved
Replace missing/expired items in vessels first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 11 August 2022
Resolution: New kit purchased.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 29 June 2022
Resolved
Vessel is required to have on board or available within 2 hours, alcohol testing strips or equipment.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2022
Resolved 11 August 2022
Resolution: Purchased.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 20 July 2021
Resolved
Prove proper operation of bilge alarm light space #4
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2021
Resolution: Rectified
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 July 2021
Resolved
Renew epirb hydrostatic release and battery prior to operations beyond 3 NM.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 July 2021
Resolved 20 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2021
Resolved
Replace 01 type 1 PFD prior to carrying more than 159 total persons.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 July 2021
Resolved 20 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 July 2021
Resolved
Fix loose wiring underneath console and properly connect with approved connectors.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2021
Resolved 7 September 2021
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 20 July 2021
Resolved
Prove position information in DSC capable VHF radio.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2021
Resolved 11 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 July 2021
Resolved
Double up hose clamps where able to do so on all raw water providing connections in E/R.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2021
Resolved 7 September 2021
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 20 July 2021
Resolved
Lock wire all shackles on anchor terminal gear.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2021
Resolved 7 September 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 20 July 2021
Resolved
Provide alcohol test kits as required for all crew. cleared same day
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2021
Resolved 20 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 August 2020
Resolved
Starboard navigation light lens identified cracked and not water proof. Additionally white light would shine through the cracked green lense. Vessel greater than 65' Navlights do not conform to UL 1104.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 17 September 2020
Resolution: Starboard navigation light replaced with LED light.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 August 2020
Resolved
EPIRB battery expirery date marked states expired 2019. Issued requirement to prove EPIRB battery was replaced in 2019 as stated by the crew.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 17 September 2020
Resolution: EPIRB replaced and registered.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 August 2020
Resolved
Use of "twist-on" type connectors may not be used iaw 46 CFR 183.430 (i)(2). Identified twist on type connectors or the vessel's primary VHF -fm radio.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 17 September 2020
Resolution: Wiring for VHF-fm radio reconfigured to standards.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 18 August 2020
Resolved
Where the air compressor is located forward in th machinery space,port side. address the cracked welds at the next dry dock period. Added note to vessel file.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 August 2020
Resolved 18 August 2020
Resolution: Plan to address the cracked welds submitted and added to this activity.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 August 2020
Resolved
Separation of machinery space and accommodation space must be such to prevent the passage of vapors. Identified where the fuel shut off reachrods pertrude through the deck of the passenger compartment need fire stop seperating the boundry between the two spaces. submit plans for re-configuration at next dry dock.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2020
Resolved 18 August 2020
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 18 August 2020
Resolved
Remote fuel valves not labled.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 17 September 2020
Resolution: Valves Labled
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 August 2020
Resolved
Post vessel's stability letter in the pilot house as required by the issued stability letter.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 17 September 2020
Resolution: Stability leter posted as prescribbed on theissued sstability letter.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 August 2020
Resolved
Post the issued COI in the passenger cabin IAW 46 CFR 176.302
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 17 September 2020
Resolution: COI posted as prescribed in regulation
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 August 2020
Resolved
Two outlets at or near the deck of the passenger compartment were identified burnt at the ground port where deck washdowns take place. Issued requirement to replace outlets and to enclose in water tight containers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 17 September 2020
Resolution: Outlets replaced
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 18 August 2020
Resolved
Establish and maintain a drills and training log for the vessel
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 August 2020
Resolved 18 August 2020
Resolution: Training log established
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 May 2019
Resolved
46 CFR 181.30-10
Portable fire extinguishers shall be installed and located to the satisfaction of the OCMI. 02 portable fire extinguishers were found to have expired servicing tags. Provide documentation attesting to servicing of both extinguishers to the satisfaction of attending USCG MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2020
Resolution: Deficiency inspected for the 2020 annual inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2019
Resolved
46 CFR 182.530
ON a vessel of 26 feet in length and greater, a visual and audibule alarm must be provided at the operating station to indicate high water level for a machinery space bilge. The engine room high level visual alarm did not illuminate during testing. Prove proper operation of engine room visual high level alarm to the satisfaction of attending USCG MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2020
Resolution: Visual and audible alarms tested and inspected for the 202 annual exam; all sat
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 7 May 2019
Resolved
Float lights were not water tight IAW with specifications listed subchapter Q. Repair or replace floating electric marker lights.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 May 2019
Resolved 7 May 2019
Resolution: Floating electric marker lights were replaced with new units.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2019
Resolved
Vessel certificated for 160 "total persons" (150 passengers). vessel only had 159 type I PFDs on board. Restricted use to a maximum of 159 "total persons".
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 May 2019
Resolved 7 May 2019
Resolution: Vessel O/O placed 1 new adult size PFD on board. Def. cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 May 2019
Resolved
PFD lights attached were installed improperly, where in order to energize the PFD light, the lights would become detached from the PFD.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 13 May 2019
Resolution: Crew attached all lifejacket lights correctly so they would stay attached to lifejackets when energized.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 May 2019
Resolved
Wiring in the machinerty space is secured to other wires by plastic wire ties only. Wires must be secured by wetallic wiring harnesses IAW CFR
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 13 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 May 2019
Resolved
Fire extinguishers on board had improperly marked tags with past due dates marked. O/O had paperwork on the vessel stating all PFEs were inspected by an approved facility. Facility returned to the vessel an corrected the tags. 1 PFE was extinguished and the PFE was removed from the vessel, buit not required to be replaced as it was in excess to requirements.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 May 2019
Resolved 7 May 2019
Resolution: Deficiencies corrected by approved facility and extinguished PFE was removed from the vessel. Removed PFE was carried in excess.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 7 May 2019
Resolved
Remote fuel shut-off pulls not labled. Label remote fuel shut off valves. Crew demonstrated knowledge of the valves location and operation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 13 May 2019
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 7 May 2019
Resolved
Found oil absorbent pads under bilge suction screens where if flooding occured pads would clog and cover bilge suction. required O/O to remove bilge suction pads from under the suction fitting.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 13 May 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 May 2019
Resolved
Electrical recepticle in the pilot house STBD side was discolored and showed signs of overloading with possible burn marks. required O/O to install new recepticle and test.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2019
Resolved 13 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 17 September 2018
Resolved
Vsl is broadcasting greater than expected vessel length and Vsl is broadcasting no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 1 October 2020
Resolution: Closed. Deficiency issued by NAVCEN
Communications › Radio Communications › EPIRB
Issued 22 May 2018
Resolved
Replace the sticker on the EPIRB for new vessel name. Vessel's EPIRB is registered, but the sticker is not updated.
Action required: 705 - Other - as specified
Due 29 May 2018
Resolved 24 July 2018
Resolution: O/O updated sticker on EPIRB
Navigation › Piloting/Steering › Marine Charts
Issued 5 July 2017
Resolved
Provide corrected marine charts through JUL 2017.
Due 4 August 2017
Resolved 1 August 2017
Resolution: Vessel provided updated chart with corrections.
Operations/Management › Passenger Operations › Safety Orientation
Issued 5 July 2017
Resolved
Post emergency instructions in main accommodation space.
Due 4 August 2017
Resolved 1 August 2017
Resolution: Vessel posted emergency instructions in the accommodation space.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 July 2017
Resolved
Replace thermostat cable with marine-grade, stranded copper wire.
Due 4 August 2017
Resolved 1 August 2017
Resolution: Vessel replaced cable with marine grade, stranded wire.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 5 July 2017
Resolved
Make all high-water alarm wires enclosed in juntion boxes.
Due 4 August 2017
Resolved 1 August 2017
Resolution: Junction boxes were installed for all bilge alarm wires.
Engineering › Sea-water System (primary cooling) › Pump
Issued 5 July 2017
Resolved
Replace No.2 (port) generator raw water intake pump. Prove proper operation of generator.
Due 19 July 2017
Resolved 1 August 2017
Resolution: Vessel replaced raw water pump and proved proper operation.
Engineering › Steam Boiler (auxiliary/waste heat) › Fuel Oil Burner
Issued 5 July 2017
Resolved
Vessel replaced its package boiler with new (heating only). Prior to use, vessel must prove installation in accordance with manufacturer's installation requirements, prove operation of safety alarms and shutdowns and submit aggregate weight changes to the Marine Safety Center for review. Vessel must also provide a specification sheet for the fuel hose. 46CFR176.700
Action required: 705 - Other - as specified
Resolved 7 May 2019
Resolution: Deficiency inspected by attending MI during annual inspection.
Engineering › Fuel Oil Service System › Valve
Issued 28 March 2016
Resolved
The port side fuel oil shutoff valve was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2016
Resolved 13 April 2016
Resolution: Observed proper operation of port f/o shutoff.
Communications › Radio Communications › EPIRB
Issued 28 March 2016
Resolved
The hydrostatic release for the EPIRB is expired. Install valid hydrostatic release.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2016
Resolved 13 April 2016
Resolution: Observed valid hydrostatic release on EPIRB.
Operations/Management › Pollution › Control of Garbage
Issued 28 March 2016
Resolved
The vessel does not have a waste management plan onboard. Provide CG marine inspector with a waste management plan.
Condition: Improper/Lack of Maintenance
Due 15 April 2016
Resolved 13 April 2016
Resolution: Vessel provided waste management plan.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 28 March 2016
Resolved
The vessel's nautical publications where out of date.
Condition: Invalid
Due 28 April 2016
Resolved 13 April 2016
Resolution: Vessel provide 2016 nautical publications.
Documentation › Logs/Records › Logbook (official)
Issued 28 March 2016
Resolved
The vessel did not have a logbook for the 2016 year onboard. Provide a CG marine inspector with a 2016 logbook.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2016
Resolved 13 April 2016
Resolution: Vessel provided 2016 logbook.