Records from 2010 to 2026. Most recent: inspection, 20 April 2026.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 16.0 ft × 3.5 ft
Registered tonnagegross 14 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLIVING CLASSROOMS FDN · BALTIMORE, MD, UNITED STATES · built 1994
Hull materialWood
PropulsionDiesel Reduction
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portBALTIMORE, MD
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 April 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
12 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
20 April 2026
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8353619
25 February 2026
Hull Examination · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8329248
19 March 2025
Administrative Inspection · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8098576
16 January 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8064588
9 December 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8045318
13 June 2024
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7943028
30 May 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7923365
29 June 2023
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7726136
20 June 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7719000
17 March 2023
Internal Structural Exam · In-Service Inspection · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7664536
23 January 2023
Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7625418
6 June 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7469657
16 June 2021
In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7227315
29 May 2021
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7209648
5 May 2021
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7209621
23 March 2020
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6902501
5 August 2019
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6776621
30 April 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6697941
25 March 2019
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6655804
4 February 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6619626
23 April 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6397676
3 April 2018
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6384659
6 March 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6366587
18 April 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6127498
20 April 2016
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5861911
25 February 2016
Administrative Inspection · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5821670
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2024
Resolved
46 CFR 182.455(b)(4) - Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection andone at the engine end of the fuel line to stop fuel flow when serviceing accessories. The shut off at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Fuel shutoff valve would not completely close.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 13 June 2024
Resolution: Operator sent video of corrected fuel shut-off valve to the satisfaction of the CG Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 June 2023
Resolved
10109 - A power-driven vessel underway shall exhibit a masthead light forward. The masthead light is inoperable.
33 CFR 83.23(a)(i)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 June 2023
Resolution: Received photographic evidence of operable masthead light.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 June 2021
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's running lights were inoperable at time of inspection.
46 CFR 183.420
33 CFR 83.22
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 22 June 2021
Resolution: Verified proper operation of vessel's running lights during underway inspection on 6/22/21.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 June 2021
Resolved
Flexible hose must be adapted to resist the action of heat and has a wall thickness sufficient to prevent collapsing. Chafing gear attached to flexible hose in exhaust line worn due to heat/vibration. Replace in kind.
46 CFR 182.115(a)
"Old T" 182.15-20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 17 June 2021
Resolution: Received photographic evidence from vessel rep [name withheld] confirming new chafing gear has been affixed to engine exhaust hoses.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 June 2021
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] intrusion observed in vessel's forward compartment at copper flashing joining keel and centerboard trunk
46 CFR 176.700(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2021
Resolved 30 June 2021
Resolution: Received satisfactory photographic evidence of repairs made to vessel's centerboard and adjacent copper flashing. Photos and explanation of repair provided by vessel rep uploaded into activity under "Documents."
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 May 2021
Resolved
A vessel that is exposed to salt water more than three months in any twelve month period since the last exam must undergo a drydock exam at least once every two years. Due to the personnel shortage due to the COVID-19 pandemic the vessel owner/operator was unable to complete the drydock exam prior to their required date of 2/28/2021
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2021
Resolution: Vessel O/O completed successful Drydock inspection. See Activity # 7209621
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 March 2020
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's stern light lens wasted/fogged negatively impacting visibility. Repair to standards within Inland Navigation Rules, 33CFR83.22.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2020
Resolved 16 June 2021
Resolution: Verified operation of sternlight lens during annual inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 March 2020
Resolved
Each ring life buoy with a floating waterlight must have a lanyard securing the waterlight around the body of the ring buoy. Lanyard was found to be wasted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2020
Resolved 16 June 2021
Resolution: Ring life buoys and lanyards found in serviceable condition at time of annual inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 March 2020
Resolved
The float free link required by 46CFR180.130(a)(1) must be of proper strength for the size of the life float as indicated on its identification tag. Float free link tag was missing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2020
Resolved 16 June 2021
Resolution: Float free link tag was found in good condition during annual inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 23 March 2020
Resolved
Deck rails must be designed to and construct to withstand a point load of 200 lbs applied at any point in any direction, and a uniform load of 50 lbs per foot applied to the top rail in any direction. Port side forward railing where it joins the deck was found to be wasted and fractured.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2020
Resolved 16 June 2021
Resolution: Railing portion appeared in serviceable condition at time of annual inspection.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 23 March 2020
Resolved
At each inspection for certification, the marine inspector may require abandon ship or man overboard drills be held. Drills not held due to insurance hold.
Drills must be held prior to carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2020
Resolved 22 June 2021
Resolution: Successfully completed drills while underway 6/22/21. See MISLE #7227315 for more information.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 February 2019
Resolved
Due to Dry-dock/ISE/Refastening, Vessel will be required to get underway to examine interior spaces for leaks and weepage prior to operating with passengers for hire.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 February 2019
Resolved 25 March 2019
Resolution: Sea Trials Completed. All Sat.
Construction/Loadline › Hull › Bracket
Issued 20 April 2016
Resolved
During underway evaluation of vessel operation. A minimal weepege was noticed IWO the stem block above the waterline intersection. noticed due to moisture visable and not continous. Vessel is to provide a proposal to make permanent repairs. Proposal due by 01 June and final repairs NLT end of next DDX (2017)
Condition: Invalid
Due 1 June 2016
Resolved 3 April 2018
Resolution: Conducted sea trial after dry-dock/ISE and cleared above deficiency.
Construction/Loadline › Hull › Bracket
Issued 20 April 2016
Resolved
Copper sheathing around centerboard socket had noticable weepege but not excessive. Repair or replace sheathing around centerboard thunk and hull mounting interface to prevent excesive weeping
Condition: Invalid
Due 1 July 2016
Resolved 3 April 2018
Resolution: Conducted sea trial after dry-dock/ISE and cleared above deficiency.
Construction/Loadline › Hull › Sheerstrake
Issued 4 March 2016
Resolved
Repair Stbd side Sheer Strake plank forward edge in way of stem which is soft and wasted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 29 March 2016
Resolution: Inspected affected area. O/O is preserving area after cleaning out soft wood and treated with paint.
Sail Rigging › Spars › Masthead Hardware and Sheaves
Issued 25 February 2016
Resolved
Vessel required to operate under full sail, to the satisfaction of attending marine inspectors, prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2016
Resolved 29 March 2016
Resolution: Attended vessel conducted U/W undersail inspection of vessels mast, standing and running rigging. All sat