Records from 2013 to 2021. Most recent: inspection, 5 January 2021.
Inspection history · 17
5 January 2021
COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7122545
16 November 2020
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7101334
19 August 2020
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7023286
5 March 2020
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6921391
30 July 2019
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6767001
24 June 2019
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6719439
1 November 2018
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6572685
24 September 2018
Administrative Inspection · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6545484
17 August 2018
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6567828
30 July 2018
Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6472817
17 November 2017
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 6376527
8 November 2017
Drydock Extension · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6303622
11 September 2017
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6265309
24 August 2016
Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5982213
21 July 2016
Examination of Repairs
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5947842
11 May 2016
Type not recorded
No type recorded · Station Oswego · USCG Great Lakes District (CGD-GL) · Activity 5875830
25 March 2016
Administrative Inspection · Plan Review (Other than "T")
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5840697
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 August 2020
Resolved
Life float body was found deteriorated and beyond it's serviceability life.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 4 September 2020
Resolution: Received email with photo showing the installation of new life float.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2020
Resolved
Safety valves on pressure vessels shall be tested twice every 5 years not to exceed 3 years between tests. No test tag was found on the safety valves. Bench test with 3rd party or in the presence of a CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 25 September 2020
Resolution: Owner texted pictures and statement of new safety relief valves installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2019
Resolved
Vessel did not have the Emergency Instructions posted at operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 10 July 2019
Resolution: Received text with picture showing proper emergency instructions have been posted.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 24 June 2019
Resolved
EPIRB registration sticker was not affixed to the EPIRB housing. Master stated the sticker is missing and owner will procure a new registration sticker. Vessel is restricted to no more than 3 NM from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 July 2019
Resolution: Vessel received new EPIRB and new registration sticker.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 24 June 2019
Resolved
EPIRB battery was found to be expired. Master stated the EPIRB will be sent to manufacturer for a new battery. Vessel is restricted to no more than 3 NM from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 July 2019
Resolution: Vessel received new EPIRB and new registration sticker.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 June 2019
Resolved
Life jacket light batteries had not been changed annually. Daylight operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 June 2019
Resolution: All life jacket batteries have been replaced.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 June 2019
Resolved
Light list was not on board during inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 25 June 2019
Resolution: Master placed a current light list on board.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 June 2019
Resolved
Vessel did not have a Coast Pilot on board during the inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 25 June 2019
Resolution: Master placed a current Coast Pilot on board the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 June 2019
Resolved
Starboard navigation light was extinguished. Vessel restrict to daylight and fair weather operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 June 2019
Resolution: Master replaced bulb in starboard navigation light, tested satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2019
Resolved
Found main shore power connection spiced into wires in engine room. All splices are required to be made within a junction box. Shore power connection box must be permanently installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 July 2019
Resolved 10 July 2019
Resolution: Permanent shore tie receptacle was installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 June 2019
Resolved
The lazarette did not have a bilge high water alarm installed. Vessel is required to have a bilge high water alarm due to through-hull fittings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 July 2019
Resolved 10 July 2019
Resolution: Owner installed new bilge water level indicator in the lazerette and alarm in the pilothouse.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 July 2018
Resolved
Vessel had problems dewatering #4 void for test.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2018
Resolved 31 July 2018
Resolution: Owner found broken primer piping for the bilge pumps. Replaced primer piping and retested both bilge pumps successfully dewatering #1 and #4 voids.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 November 2017
No resolution recorded
Found aft transverse engine room bulkhead on the port side severely creased. Crop and renew creased transverse aft engine room bulkhead.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2018 — due date passed with no resolution recorded
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 November 2017
No resolution recorded
Found aft transverse engine room bulkhead on the stbd side severely creased. Crop and renew creased transverse aft engine room bulkhead.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2018 — due date passed with no resolution recorded
Construction/Loadline › Hull › Side Shell
Issued 8 November 2017
Resolved
Vessel has two "sounding" covers, one port and one stbd, per void located on the top of the the void. These covers are approximately 8" in diameter and are bolted down and the metal around each cover is severely wasted. Vessel to crop out covers, insert and weld plate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 24 September 2018
Resolution: Non-watertight covers at the top of the voids have been welded to make watertight.
Electrical › Electrical Distribution System (service) › Cable
Issued 11 September 2017
Resolved
Found "Romex" style wiring on the 120 volt lighting circuit. Vessel to remove noncompliant wiring and install wiring as per Sub Chapter "J" for stranded wiring.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 30 July 2018
Resolution: Cable was replaced with proper boat cable.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 11 September 2017
Resolved
Found excessive oil in the engine room bilge. Vessel to pump out bilge and keep oil free.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: Vessel pumped out all standing oil in the engine room bilges.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 11 September 2017
Resolved
Excessive oil leaking from all main engines. Vessel crew will continue to repair leaking gaskets throughout the engines.
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: Crew was able to tighten up a few fittings and change a few gaskets. Crew will continue to control oil.
Electrical › Electric Supply System (service) › Cable
Issued 11 September 2017
Resolved
Found multiple 12 volt battery connections exposed without covers. Crew will provide covers for all 12 volt battery connections.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 21 September 2017
Resolution: Crew installed covers on all battery post connections.
Construction/Loadline › Penetrations › Pipe Flange
Issued 11 September 2017
Resolved
Found abandoned misc piping in engine room not capped or plugged going through the hull. Crew will remove old piping and cap or plug connection going through the hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: All dead end piping in the engine room has been capped or plugged.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 11 September 2017
Resolved
Found oil begining to soak into the exhaust lagging on port and stbd engines. Crew to replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: Crew cleaned and replaced oil soaked lagging.
Construction/Loadline › Penetrations › Pipe Flange
Issued 11 September 2017
Resolved
Found misc abandoned piping in engine room going through the hull with no caps or plugs. Crew to and and/or plug end fittings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: Piping has been capped.
Fire Fighting › Fire Pumps › Suction Valve
Issued 11 September 2017
Resolved
Found wasted hose on the installed fire pump. Crew to replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: Wasted hose was replaced with new.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 11 September 2017
Resolved
Master did not have a FCC radio operators permit.
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 30 July 2018
Resolution: Master obtained FCC operators license.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 11 September 2017
Resolved
Vessel did not have a FCC Great Lakes radio inspection complete.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: FCC GL radio inspection is complete.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 September 2017
Resolved
Found water in navigation light housings. Vessels navigation light housings were missing gasktes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: Crew installed new gaskets on nav Light housings.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 11 September 2017
Resolved
Vessel was missing posted Emergency Instructions
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: Emergency instructions are posted in the pilot house.
Lifesaving › Hand Flares › Expired
Issued 24 August 2016
Resolved
Provide two additional red hand flares, stow in a brightly colored portable container marked "DISTRESS SIGNALS".
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 25 August 2016
Resolution: New flares onboard in a brightly colored container marked "DISTRESS SIGNALS".
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 24 August 2016
Resolved
Repair port outboard engine rpm indicator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 8 September 2017
Resolution: New gauage was installed.