Records from 2002 to 2021. Most recent: inspection, 5 January 2021.
Inspection history · 33
5 January 2021
COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7122545
16 November 2020
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7101334
19 August 2020
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7023286
5 March 2020
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6921391
30 July 2019
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6767001
24 June 2019
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6719439
1 November 2018
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6572685
24 September 2018
Administrative Inspection · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6545484
17 August 2018
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6567828
30 July 2018
Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6472817
17 November 2017
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 6376527
8 November 2017
Drydock Extension · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6303622
11 September 2017
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6265309
24 August 2016
Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5982213
21 July 2016
Examination of Repairs
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5947842
11 May 2016
Type not recorded
No type recorded · Station Oswego · USCG Great Lakes District (CGD-GL) · Activity 5875830
25 March 2016
Administrative Inspection · Plan Review (Other than "T")
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5840697
7 October 2015
Administrative Inspection · Excursion Permit
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5739430
24 August 2015
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5226364
17 August 2015
Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5219040
7 June 2012
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 4336478
11 June 2008
COI Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3256031
15 April 2008
Hull Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3207110
17 August 2006
Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2752113
25 October 2005
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2521815
2 August 2005
Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2475450
16 March 2005
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2311880
24 September 2004
Administrative Inspection
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2204062
12 August 2004
Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2167505
9 June 2004
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2093184
8 May 2003
Hull Examination · Initial Certification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1789299
17 December 2002
Administrative Inspection
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1720012
13 December 2002
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1718655
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 August 2020
Resolved
Life float body was found deteriorated and beyond it's serviceability life.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 4 September 2020
Resolution: Received email with photo showing the installation of new life float.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2020
Resolved
Safety valves on pressure vessels shall be tested twice every 5 years not to exceed 3 years between tests. No test tag was found on the safety valves. Bench test with 3rd party or in the presence of a CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 25 September 2020
Resolution: Owner texted pictures and statement of new safety relief valves installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2019
Resolved
Vessel did not have the Emergency Instructions posted at operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 10 July 2019
Resolution: Received text with picture showing proper emergency instructions have been posted.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 24 June 2019
Resolved
EPIRB registration sticker was not affixed to the EPIRB housing. Master stated the sticker is missing and owner will procure a new registration sticker. Vessel is restricted to no more than 3 NM from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 July 2019
Resolution: Vessel received new EPIRB and new registration sticker.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 24 June 2019
Resolved
EPIRB battery was found to be expired. Master stated the EPIRB will be sent to manufacturer for a new battery. Vessel is restricted to no more than 3 NM from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 July 2019
Resolution: Vessel received new EPIRB and new registration sticker.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 June 2019
Resolved
Life jacket light batteries had not been changed annually. Daylight operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 June 2019
Resolution: All life jacket batteries have been replaced.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 June 2019
Resolved
Light list was not on board during inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 25 June 2019
Resolution: Master placed a current light list on board.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 June 2019
Resolved
Vessel did not have a Coast Pilot on board during the inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 25 June 2019
Resolution: Master placed a current Coast Pilot on board the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 June 2019
Resolved
Starboard navigation light was extinguished. Vessel restrict to daylight and fair weather operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 June 2019
Resolution: Master replaced bulb in starboard navigation light, tested satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2019
Resolved
Found main shore power connection spiced into wires in engine room. All splices are required to be made within a junction box. Shore power connection box must be permanently installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 July 2019
Resolved 10 July 2019
Resolution: Permanent shore tie receptacle was installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 June 2019
Resolved
The lazarette did not have a bilge high water alarm installed. Vessel is required to have a bilge high water alarm due to through-hull fittings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 July 2019
Resolved 10 July 2019
Resolution: Owner installed new bilge water level indicator in the lazerette and alarm in the pilothouse.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 July 2018
Resolved
Vessel had problems dewatering #4 void for test.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2018
Resolved 31 July 2018
Resolution: Owner found broken primer piping for the bilge pumps. Replaced primer piping and retested both bilge pumps successfully dewatering #1 and #4 voids.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 November 2017
No resolution recorded
Found aft transverse engine room bulkhead on the port side severely creased. Crop and renew creased transverse aft engine room bulkhead.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2018 — due date passed with no resolution recorded
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 November 2017
No resolution recorded
Found aft transverse engine room bulkhead on the stbd side severely creased. Crop and renew creased transverse aft engine room bulkhead.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2018 — due date passed with no resolution recorded
Construction/Loadline › Hull › Side Shell
Issued 8 November 2017
Resolved
Vessel has two "sounding" covers, one port and one stbd, per void located on the top of the the void. These covers are approximately 8" in diameter and are bolted down and the metal around each cover is severely wasted. Vessel to crop out covers, insert and weld plate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 24 September 2018
Resolution: Non-watertight covers at the top of the voids have been welded to make watertight.
Electrical › Electrical Distribution System (service) › Cable
Issued 11 September 2017
Resolved
Found "Romex" style wiring on the 120 volt lighting circuit. Vessel to remove noncompliant wiring and install wiring as per Sub Chapter "J" for stranded wiring.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 30 July 2018
Resolution: Cable was replaced with proper boat cable.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 11 September 2017
Resolved
Found excessive oil in the engine room bilge. Vessel to pump out bilge and keep oil free.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: Vessel pumped out all standing oil in the engine room bilges.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 11 September 2017
Resolved
Excessive oil leaking from all main engines. Vessel crew will continue to repair leaking gaskets throughout the engines.
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: Crew was able to tighten up a few fittings and change a few gaskets. Crew will continue to control oil.
Electrical › Electric Supply System (service) › Cable
Issued 11 September 2017
Resolved
Found multiple 12 volt battery connections exposed without covers. Crew will provide covers for all 12 volt battery connections.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 21 September 2017
Resolution: Crew installed covers on all battery post connections.
Construction/Loadline › Penetrations › Pipe Flange
Issued 11 September 2017
Resolved
Found abandoned misc piping in engine room not capped or plugged going through the hull. Crew will remove old piping and cap or plug connection going through the hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: All dead end piping in the engine room has been capped or plugged.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 11 September 2017
Resolved
Found oil begining to soak into the exhaust lagging on port and stbd engines. Crew to replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: Crew cleaned and replaced oil soaked lagging.
Construction/Loadline › Penetrations › Pipe Flange
Issued 11 September 2017
Resolved
Found misc abandoned piping in engine room going through the hull with no caps or plugs. Crew to and and/or plug end fittings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: Piping has been capped.
Fire Fighting › Fire Pumps › Suction Valve
Issued 11 September 2017
Resolved
Found wasted hose on the installed fire pump. Crew to replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: Wasted hose was replaced with new.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 11 September 2017
Resolved
Master did not have a FCC radio operators permit.
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 30 July 2018
Resolution: Master obtained FCC operators license.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 11 September 2017
Resolved
Vessel did not have a FCC Great Lakes radio inspection complete.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: FCC GL radio inspection is complete.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 September 2017
Resolved
Found water in navigation light housings. Vessels navigation light housings were missing gasktes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: Crew installed new gaskets on nav Light housings.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 11 September 2017
Resolved
Vessel was missing posted Emergency Instructions
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: Emergency instructions are posted in the pilot house.
Lifesaving › Hand Flares › Expired
Issued 24 August 2016
Resolved
Provide two additional red hand flares, stow in a brightly colored portable container marked "DISTRESS SIGNALS".
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 25 August 2016
Resolution: New flares onboard in a brightly colored container marked "DISTRESS SIGNALS".
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 24 August 2016
Resolved
Repair port outboard engine rpm indicator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 8 September 2017
Resolution: New gauage was installed.
Lifesaving › Hand Flares › Expired
Issued 24 August 2015
Resolved
Provide two (02) additional hand red flare distress signals (46 CFR 180.68 (a)(1).
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 August 2015
Resolved 1 September 2015
Resolution: Received notification from MSD inspector that item had been corrected.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 7 June 2012
Resolved
Owner did not have a EAP policy statement nor training informing employee's on the SAP name and contact info nor emergency hotline info per 46 CFR 16.230
Action required: 705 - Other - as specified
Due 30 June 2012
Resolved 27 June 2012
Resolution: Policy created and emergency number''s posted in office and an board vessel.
Engineering › Bilge Water Management System › Pump
Issued 7 June 2012
Resolved
Drive belts to both bilge pumps were very worn and need replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2012
Resolved 27 June 2012
Resolution: Belts all replaced with new ones.
Fire Fighting › Remote Fuel Shutoff › General
Issued 7 June 2012
Resolved
Starboard fuel shut-off pull cable noperable due to lack of lubrication/maintenance. Needs repair or replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2012
Resolved 27 June 2012
Resolution: New pull cable installed to fuel shut off
Electrical › Lighting (service) › Lighting Fixture
Issued 7 June 2012
Resolved
Lighting fixture over port side main/transmission box not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2012
Resolved 27 June 2012
Resolution: lighting fixture replaced
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 June 2012
Resolved
Emergency light cover near engineroom ladder missing. Cover was removed to replace light bulb but never put back into place by crewmember.
Action required: 705 - Other - as specified
Due 30 June 2012
Resolved 27 June 2012
Resolution: Lighting cover replaced.
Lifesaving › Lifefloat › Float-free Link
Issued 17 August 2006
Resolved
Provide equipment for lifefloat IAW 46 CFR 180.75 (d) and stow IAW 46 CFR 180.130. (Name on Lifefoat and paddles missing, Float free link not onboard). Vessel is restricted to river's route until corrected.
Due 4 September 2006
Resolved 16 August 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 August 2006
Resolved
Perform hydrostatic test on E/R BII extinguisher.
Due 4 September 2006
Resolved 16 August 2007
Fire Fighting › Fire Pumps › Pressure
Issued 17 August 2006
Resolved
Provide firepump pressure guage IAW 46 CFR 181.300(b)
Due 16 September 2006
Resolved 16 August 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 August 2006
Resolved
Replace expired items in first aid kit.
Due 4 September 2006
Resolved 16 August 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 17 August 2006
Resolved
Provide FCC operators license.
Due 30 September 2006
Resolved 16 August 2007
Lifesaving › Lifefloat › Paddle
Issued 16 March 2005
Resolved
Provide Equipment for Life Float IAW 46 CFR 180.175(d). Vessel is restricted to rivers route until items are provided. Paddles, Markings, Painter, Water Light have not been provided for.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 April 2005
Resolved 2 August 2005
Resolution: Provided equipment.
Lifesaving › Hand Flares › Quantity
Issued 16 March 2005
Resolved
Provide additional distress flares for Great Lakes route IAW 46 CFR 180.68(a). Currently vessel only has number for Rivers Route. Vessel is restricted to Rivers route until items are provided.
Condition: Improper Installation
Due 16 April 2005
Resolved 2 August 2005
Resolution: Provided additional flares.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 16 March 2005
Resolved
Provide an approved life jacket light IAW 46 CFR 180.75(a) for eachlife jacket onboard. Vessel is restricted to rivers route until items are provided.
Condition: Improper Installation
Due 16 April 2005
Resolved 2 August 2005
Resolution: Life jacket lights were not approved, owner replaced with new approved lights.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 12 August 2004
Resolved
Provide two adult type-i lifejackets. Vessel is restricted to carrying six persons until provided.
Due 12 September 2004
Resolved 26 August 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 August 2004
Resolved
Repair as original lifering waterlight. Mount with proper bracket.
Due 26 August 2004
Resolved 26 August 2004
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 12 August 2004
Resolved
Provide and mount a lifejacket donning placard IAW 46 CFR 185.516.
Due 26 August 2004
Resolved 26 August 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 August 2004
Resolved
Provide retro reflective tape on life ring.
Due 26 August 2004
Resolved 26 August 2004
Operations/Management › Drills/Instruction › Fire
Issued 12 August 2004
Resolved
Provide emergency instructions IAW 46 CFR 185.510 and 185.512.
Due 26 August 2004
Resolved 26 August 2004
Operations/Management › Equipment Service/Testing › EPIRB
Issued 8 May 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 July 2003
Resolved 12 August 2004
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 8 May 2003
Resolved
Stencil lifejackets with the vessel's name.
Condition: Unknown
Due 5 July 2003
Resolved 12 August 2004
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 8 May 2003
Resolved
Provide two (2) additional type 1 lifejackets. Vessel restricted to six (6) total persons onboard until lifejackets are provided.
Condition: Unknown
Due 12 July 2003
Resolved 26 August 2004
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 May 2003
Resolved
Stencil lifejacket stowage locker.
Condition: Unknown
Due 5 July 2003
Resolved 12 August 2004
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 8 May 2003
Resolved
Provide placard of lifesaving signals.
Condition: Unknown
Due 5 July 2003
Resolved 12 August 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 May 2003
Resolved
Provide navigation lights approved for vessels over 20 meters in length.
Condition: Unknown
Due 1 April 2007
Resolved 16 August 2007
Resolution: Replaced nav lights with proper size.
Engineering › Fuel Oil Service System › Valve, Control
Issued 8 May 2003
Resolved
Provide remote actuator for valves located at the fuel oil tanks.
Condition: Unknown
Due 12 July 2003
Resolved 12 August 2004