Records from 1994 to 2017. Most recent: inspection, 11 December 2017.
Inspection history · 23
11 December 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6321270
1 October 2007
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3070468
28 September 2007
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3068098
28 September 2007
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3068473
29 May 2006
ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2663122
4 December 2005
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2545525
2 December 2005
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2544875
5 August 2004
ISPS II Exam · PII Safety Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2156488
21 July 2004
ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2140897
16 September 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1906477
15 September 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1905661
28 May 2003
Annual Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1802093
13 February 2003
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1744038
23 November 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1709700
15 November 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1706033
28 October 2002
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1697335
26 October 2002
Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1697275
8 June 2002
Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1628205
1 April 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1600193
11 July 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 291673
14 February 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 287169
19 September 1994
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 370563
19 September 1994
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 869187
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 11 December 2017
No resolution recorded
SEE NARRATIVE.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 11 December 2017
No resolution recorded
SEE NARRATIVE
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 28 September 2007
Resolved
The document does not state the amount of GMDSS Officers required as per the Cargo Ship Safety Certificate. Flag to attest the validity of the Safe Manning document.
Due 29 September 2007
Resolved 29 September 2007
Construction/Loadline › Structures › Scupper
Issued 28 September 2007
Resolved
Scuppers were not in place. Crew is to verify deck scuppers and drains are plugged. The RO is to attest to the implementation of the management manual.
Due 29 September 2007
Resolved 29 September 2007
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 28 September 2007
Resolved
The discrepancy between the Minimum Safe Manning document and the Cargo Ship Saftey Certificate is to be addressed by the RO.
Due 29 September 2007
Resolved 29 September 2007
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 28 September 2007
Resolved
The gasket n the hatch cover, aft, starboardside is wasted, worn, and falling apart. Class to attest to the weathertight integrity of the gasket and hatch cover.
Due 29 September 2007
Resolved 29 September 2007
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 28 September 2007
Resolved
Vessel failed to report ballast. Master educated on reporting requirements and instructed to provide adequate proof of such information to the USCG.
Due 29 September 2007
Resolved 29 September 2007
Lifesaving › Lifeboat Equipment › Food Ration
Issued 28 September 2007
Resolved
Vessel is short two food rations. Provide proof that the lifeboat is stocked with the appropriate amount of food.
Due 29 September 2007
Resolved 29 September 2007
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 28 September 2007
Resolved
Vessel Failed to ensure that the discharge containment mechanical closures were in place during an oil transfer. Prove proper operation of mechanical closures to the satisfaction of attending USCG.
Due 29 September 2007
Resolved 29 September 2007
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 28 September 2007
Resolved
Vessel failed to ensure that drains and scuppers were closed by mechanical means as required. Several closures missing, replace and prove porper operation and readiness to the coast guard.
Due 29 September 2007
Resolved 29 September 2007
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 28 September 2007
Resolved
Faileed to ensure that all means of mechanical closure devices for containment and scuppers were in place prior to and during a transfer of oil and oily substances. RO is to attest the the emplementation of the management manual chapert 4.1.7 Prior to departure.
Due 29 September 2007
Resolved 29 September 2007
Lifesaving › Buoyant Apparatus › Lifeline
Issued 28 September 2007
Resolved
The Lifeline located on the port bow is in a general poor condition and requires replacement. Provide proof of an adequate lifering to the statisfaction of the coast guard prior to departure.
Due 29 September 2007
Resolved 29 September 2007
Lifesaving › Lifeboat › Markings
Issued 28 September 2007
Resolved
The name and port of registry to which the lifeboat belongs has been marked on the stern of the lifeboat. The name and port of registry of the ship to which the lifeboat belongs shall be marked on each side of the lifeboats bow in block capital letters of the Roman Alphabet to the satisfaction of class.
Due 13 October 2007
Resolved 29 September 2007
Lifesaving › Buoyant Apparatus › Marking
Issued 28 September 2007
Resolved
The lifering on the port bow is missing an information placard as required by 74 SOLAS (2004) III/20.10 additionally the lifering fitted with a light on the port quarter, in the area of the gangway is fitted with a placard for a lifering without a light. Fix and replace the required information symbol placards to the satisfaction of class.
Due 13 October 2007
Resolved 29 September 2007
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 2 December 2005
Resolved
Rescue boat unable to deploy due to crane malfunction. Provide Class report attesting to repairs on Crane System for rescue boat. SOLAS Ch. III/Reg 17
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2005
Resolution: Vessel Provided Class Report attesting to repairs being made.
Fire Fighting › Miscellaneous Items
Issued 26 October 2002
Resolved
Vessel's fire plan had not been audited since 1991. Vessel now contains much more fire fighting capabilities than listed on plan. Vessel instructed to update plan.
Action required: 15 - Rectify deficiencies by next port
Resolved 10 February 2003
Resolution: Viewed that vessel had a new and updated fire control plan to the satisfaction of attending C.G. Boarding Officer. New plan had Class Stamp and viewed last class survey attesting to plans renewal.
Documentation › Logs/Records
Issued 1 April 2002
Resolved
Vessels oil record book states on two occasions the vessel pumped 2.5 m3 through the 15-ppm seperator equipment in a 2-hour period (see attached documents oil record book). The vessels IOPP states the maximum throughput of the 15-ppm seperator is 1m3 per hour (see attached documents IOPP 1-5). LEGACY COMPONENT DESC: Oil Record Book
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 5 April 2002
Resolved 8 June 2002
Resolution: Received copies of IOPP suppliment and oil record book. Verified proper entries.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 1 April 2002
Resolved
Master of vessel does not have his national license with him. Master holds an Antiguan endorsement of his national license.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2002
Resolved 2 April 2002
Resolution: Recievied a faxed copy of masters national license with flag approval.
Fire Fighting
Issued 14 February 2001
Resolved
PROVIDE ANOTHER FIRE SUIT TO COMPLY WITH REGULATIONS SET FORTH IN SOLAS II-2/17
Condition: Unknown
Due 11 July 2001
Resolved 11 July 2001