A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Electrical
Issued 2 October 1999
Resolved
REPLACE CRACKED LIGHT COVERS THROUGHOUT ACCOMODATION SPACES. SOLAS 60 CH II/27
Condition: Unknown
Due 8 November 1999
Resolved 12 October 1999
Fire Fighting
Issued 2 October 1999
No resolution recorded
PROVIDE SPARE CO2 PORTABLE FIRE EXTINGUISHERS ON BOARD VESSEL, NUMBER OF EXTINGUISHERS TO BE DETERMINED TO THE SATISFACTION OF FLAG ADMINISTRATION PER SOLAS 60 CH 2, REG. 57.
Condition: Unknown
Due 8 November 1999 — due date passed with no resolution recorded
Navigation
Issued 2 October 1999
Resolved
PROVIDE PROPERLY OPERATING RADAR SYSTEM ON BRIDGE.
Condition: Unknown
Due 8 October 1999
Resolved 12 October 1999
Electrical
Issued 2 October 1999
Resolved
LABEL EMERGENCY LIGHTS THROUGHOUT VESSEL. SOLAS 60 CH II/25
Condition: Unknown
Due 8 October 1999
Resolved 12 October 1999
Fire Fighting
Issued 2 October 1999
Resolved
PROVIDE PROPER PAPERWORK ATTESTING PROOF THAT SERVICING REPORT DATED 25SEP97 CONCERNING CO2 CYLINDERS FOR FIXED FIRE EXTINGUISHING SYSTEM SERVE THIS SHIP.
Condition: Unknown
Due 8 October 1999
Resolved 12 October 1999
Construction/Loadline
Issued 2 October 1999
No resolution recorded
HAVE CLASS SOCIETY ADDRESS CONTINUOUS LEAK OF SEAL FOR PROPELLER SHAFT. SOLAS 60 I/7
Condition: Unknown
Due 8 November 1999 — due date passed with no resolution recorded
Fire Fighting
Issued 2 October 1999
Resolved
HAVE AN APPROVED SERVICING FACILITY DETERMINE BEST COURSE OF ACTION FOR INSPECTION/MAINTENANCE OF 47 PORTABLE CO2 FIRE EXTINGUISHERS. REPLACE CRACKED/DAMAGED CONES AS NECESSARY. SOLAS 74/78 II-2/21
Condition: Unknown
Due 8 October 1999
Resolved 12 October 1999
Fire Fighting
Issued 2 October 1999
Resolved
LABEL FIREMAN'S OUTFIT LOCKER ON FIRE SAFETY PLAN USING PROPER IMO SYMBOLS.SOLAS 74 (amended) II-2/20
Condition: Unknown
Due 8 October 1999
Resolved 12 October 1999
Navigation
Issued 2 October 1999
Resolved
PROVIDE WATCH SCHEDULE ON BRIDGE. STCW 95 VIII/1
Condition: Unknown
Due 8 October 1999
Resolved 12 October 1999
Lifesaving
Issued 2 October 1999
Resolved
PROVIDE PROPER RETRO-REFLECTIVE TAPE ON KEELS OF PORT/STARBOARD LIFEBOATS. SOLAS 74 (amended) III/30.2.7
Condition: Unknown
Due 8 October 1999
Resolved 12 October 1999
Fire Fighting
Issued 2 October 1999
No resolution recorded
ENSURE ALL HATCHES/CLOSURES FOR VENTILATION CLOSE PROPERLY AND EASILY THROUGHOUT VESSEL. ENSURE DOGS ARE PROVIDED ON ALL HATCH DOORS. ICLL 66 REG. 12
Condition: Unknown
Due 8 November 1999 — due date passed with no resolution recorded
Electrical
Issued 2 October 1999
Resolved
REPAIR/REPLACE LIGHT IN AIR CONDITIONING SPACE, PROVIDE COVER FOR LIGHT. SOLAS 60 CH II/27
Condition: Unknown
Due 8 October 1999
Resolved 12 October 1999
Fire Fighting
Issued 2 October 1999
Resolved
REPLACE GASKET FOR WATERTIGHT DOOR SERVING VENTILATION DUCTING LOCATED AFT BELOW BRIDGE DECK (LIGHT COULD BE SEEN WHEN DOOR CLOSED). ICLL 66 REG 12
Condition: Unknown
Due 8 October 1999
Resolved 12 October 1999
Accommodation/Occupational Safety
Issued 2 October 1999
Resolved
ENSURE HOT WATER PROVIDED IN CREW MEMBERS' STATEROOMS. ILO 147 AND COMDTINST 16711.12A
Condition: Unknown
Due 8 October 1999
Resolved 12 October 1999
Fire Fighting
Issued 2 October 1999
Resolved
REPAIR/REPLACE AS ORIGINAL HOLED/WASTED VENTILATION DOOR LOCATED AFT OF BRIDGE, STBD SIDE, ENSURE DOOR CLOSES PROPERLY. ICLL 66 REGS 19,20
Condition: Unknown
Due 8 October 1999
Resolved 12 October 1999
Lifesaving
Issued 2 October 1999
No resolution recorded
PROVIDE NON-EXPIRED BATTERY FOR EPIRB LOCATED OUTSIDE BRIDGEWING. SOLAS 74(amended) IV-7/10
Condition: Unknown
Due 8 November 1999 — due date passed with no resolution recorded
Electrical
Issued 2 October 1999
Resolved
MOUNT BROKEN FOR LIGHT SWITCH SERVING BATTERY ROOM ON BRIDGE DECK (ROOM SERVES FIRE DETECTION SYSTEM). SOLAS 60 CH II/27
Condition: Unknown
Due 20 October 1999
Resolved 12 October 1999
Engineering
Issued 14 January 1997
Resolved
MDE cooling pump has excess leaking at shaft. Repair or renew and provide condition report to U.S.C.G. Marine Safety Office.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Fire Fighting
Issued 14 January 1997
Resolved
#2 fire pump has soft patchs on both suction and discharge elbow. Repair or renew, provide class report of satisfactory repair to USCG.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Construction/Loadline
Issued 14 January 1997
Resolved
Aft ballast pump was unable to take suction. Repair or renew and provide condition report from class to U.S. Coast Guard Marine Safety Office.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Engineering
Issued 14 January 1997
Resolved
Main engine casualty resulting in vessel being towed to port as a dead shipfor repairs. Provide report from Class on mechanical condition of_x001C_ main engine prior to departure.
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Lifesaving
Issued 14 January 1997
Resolved
LIFE RAFTS WERE NOT ON BOARD AT TIME OF EXAMINATION. PROVIDE SERVICING REPORT TO U.S. COAST GUARD MARINE SAFETY OFFICE UPON COMPLETION OF SERVICING AND REINSTALLATION OF RAFTS.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Fire Fighting
Issued 14 January 1997
Resolved
Fire main is holed at discharge side of the auxillary fire pump. Repair orrenew and provide class report to U.S.Coast Guard Marine safety office.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Engineering
Issued 14 January 1997
Resolved
Injector cooling piping holed. Repair or renew pipe and provide condition report from class to U.S. Coast Guard Marine Safety Office.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Engineering
Issued 14 January 1997
Resolved
Aft lube oil filter hose does not meet required specifications. Renew withproper hose in accordance with manufacturer's specifications.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Fire Fighting
Issued 14 January 1997
Resolved
Portable fire extinguishers were not onboard at time of examination. Provide servicing report to the U.S. Coast Guard Marine Safety Office upon completion of servicing and reinstallation of extinguishers.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Navigation
Issued 14 January 1997
Resolved
Secondary radar system not independent of primary. Both use same antenna, unable to use on separate antenna. Repair and provide tech. report prior to return U.S. waters letter of Deviation issued to depart.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Lifesaving
Issued 14 January 1997
Resolved
Forward port and starboard lifeboats would not start. The aft starboard lifeboat emitted excess noise when engaged. Provide condition report from class to U.S.C.G. Marine Safety Office. Received report, aft stbd boat drivetrain noise still present, vsl to investigate and repair.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Documentation
Issued 21 February 1996
Resolved
THE VESSELS LOADLINE MARKINGS (PLIMSOL MARKING) WAS RUSTED AND THERE WAS NOPAINT ON IT. THE VESSEL WAS INSTRUCTED TO CORRECT THE DEFICIENCY PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Engineering
Issued 16 November 1995
Resolved
PROVIDE/ INSTALL VISUAL AND AUDIO ALARM FOR OILY WATER SEPERATOR IN_x001C_ ACCORDANCE WITH VESSELS INTERNATIONAL OIL POLLUTION PLAN (IOPP) TO_x001C_ OPERATE AT 15 PPM.
Condition: Unknown
Due 16 December 1995
Resolved 8 December 1995
Lifesaving
Issued 16 November 1995
Resolved
RENEW BUOYANT LINE ON 3 LIFEBUOYS REQUIRED BY SOLAS 60 III/21(d)
Condition: Unknown
Due 21 November 1995
Resolved 7 December 1995
Navigation
Issued 16 November 1995
Resolved
PROVIDE ON BOARD UP TO DATE CHARTS AND U.S. COAST PILOT #5 AS REQUIRED_x001C_ BY SOLAS 74 AMENDED V/20.
Condition: Unknown
Due 21 November 1995
Resolved 7 December 1995
Lifesaving
Issued 16 November 1995
Resolved
RENEW/ REPLACE BATTERIES ON IMMERSION SUITS LIGHTS. REQUIRED BY SOLAS 74_x001C_ AMENDED III/19.2
Condition: Unknown
Due 21 November 1995
Resolved 7 December 1995
Fire Fighting
Issued 16 November 1995
Resolved
REPAIR/ RENEW FIREMAIN BLEED LINE (3/4"). AS REQUIRED BY SOLAS 74 ANENED_x001C_ II-2/21.
Condition: Unknown
Due 21 November 1995
Resolved 7 December 1995