PACIFIC PEARL is a 1994 tank ship. The Coast Guard has recorded 23 inspections since 1995, most recently in January 2011, along with 9 deficiencies and 6 operational controls.
Records from 1995 to 2011. Most recent: inspection, 27 January 2011.
- Built
- 1994
- Last inspected
- 27 January 2011
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9048081 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9VBJ3
405322
Flag
SINGAPORE
—
Maury page id
psix-405322
Inspections, by type
…with no type recorded12
Years with a record
10 calendar years (1995–2011)
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it12696 - Convention (Subpart B), Net Ton
12696 - Regulatory (Subpart C or D), Net Ton
46803 - Dead Weight, Ton
55845 - Displacement, Ton
28277 - Convention (Subpart B), Gross Ton
28277 - Regulatory (Subpart C or D), Gross Ton
12696 - Regulatory (Subpart C or D), Net Ton
46803 - Dead Weight, Ton
55845 - Displacement, Ton
28277 - Convention (Subpart B), Gross Ton
28277 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 23
27 January 2011
COE-Dockside
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3934818
20 January 2011
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3928799
20 March 2010
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3699290
7 February 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3143223
6 February 2008
Deficiency Check · PI Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3145573
16 July 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2997352
16 March 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2889384
14 March 2007
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2887831
1 October 2006
MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2790931
1 October 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2791373
1 October 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2815282
22 August 2006
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2755780
27 January 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2574732
23 January 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2571271
16 November 2005
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2535978
6 September 2005
MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · COC-TVE Renew · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2254081
13 November 2003
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1947121
1 September 2000
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 281572
31 August 2000
Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 822863
9 May 1999
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 428113
9 May 1999
Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 796624
5 March 1995
Tank Vessel Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1132328
4 March 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 375711
Deficiency record · 9
Engineering › Diesel Engine (propulsion-direct drive) › Piston Ring
Issued 7 February 2008
Resolved
Vessels No 4 cylinder exhaust valve failed during inbound transit of Houston Ship Channel.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 6 September 2005
Resolved
Repair lugs on anchor chain port and starboard side were separated from links. Repair to satisfaction of USCG inspector or class.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 6 September 2005
Resolved
Replace missing clogs on #6 and #8 center cargo tank hatches to the satisfaction of USCG inspector or class.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 6 September 2005
Resolved
Repair soft patch located on oily water discharge line to the satisfaction of class.
Electrical › Electric Generation Source (emergency) › Generator
Issued 13 November 2003
Resolved
Hydraulic start motor for e-gen inoperative. Vsl master may submit signed statement and receipt for properly installed motor or report from vsl's classification society prior to departure from the NY [name withheld] (temp repair (extra batteries) cleared by Class - permanent repair remains outstanding). LEGACY COMPONENT DESC: Generator
Lifesaving › Rescue Boat
Issued 13 November 2003
Resolved
Rescue boat damaged (tear). Vsl master may submit signed statement and receipt for repair kit that rescue boat repaired IAW manufacturers recommendations or to the satisfaction of vessel's classification society prior to the departure from the New York Officer In Charge Marine Inspection Zone. LEGACY COMPONENT DESC: Hull (rigid)
Lifesaving › Inflatable Liferafts
Issued 13 November 2003
Resolved
Missing liferaft at bow. Vessel master may submit servicing report and statement that liferaft properly stowed prior to the departure from the New York Officer In Charge Marine Inspection Zone.
Fire Fighting › Nozzles
Issued 13 November 2003
Resolved
Missing fire fighting nozzle. Vessel master may submit signed statement and receipt that nozzle properly installed prior to departure from the New York Officer In Charge Marine Inspection Zone.
Deck/Cargo › Vapor Control Systems
Issued 13 November 2003
Resolved
Vapor recovery system starboard aft control panel controller piping damaged. Correct to satisfaction of vessel's classification society prior to the departure from the New York Officer In Charge Marine Inspection Zone.