Records from 1985 to 2016. Most recent: inspection, 12 September 2016.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 80
12 September 2016
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5999192
9 March 2016
Administrative Inspection · Uninspected Other
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5830327
20 October 2014
Annual Inspection · MARPOL Annex VI Survey · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5008520
25 June 2012
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4356744
6 January 2011
MTSA/ISPS Verification · COI Inspection · MARPOL Annex IV Survey · MARPOL Annex I Examination · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3914139
12 May 2008
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3204968
17 March 2008
Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3232391
3 September 2007
Internal Structural Exam · Inclining Experiment · Hull Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 3062498
22 April 2007
MARPOL Annex V Examination · MTSA/ISPS Verification · MARPOL Annex I Examination · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2887549
1 February 2007
Deficiency Check · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2910617
2 June 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2668250
1 March 2006
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2590715
15 February 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2585676
24 January 2006
Examination of Repairs · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2572653
18 November 2005
Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2537059
20 July 2005
MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2439394
1 February 2005
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2284704
27 December 2004
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2265252
14 June 2004
MTSA/ISPS Verification
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 2078485
24 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1982887
9 September 2003
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1900486
2 September 2003
Hull Examination · MARPOL Annex V Examination · Internal Structural Exam · MARPOL Annex I Examination · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1932557
22 July 2003
Annual Inspection · MARPOL Annex V Examination
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1848667
30 July 2002
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1630050
9 January 2002
Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1476971
11 December 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1440616
3 October 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 772146
3 October 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1433885
12 July 2001
COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1362398
27 May 2001
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 1362229
8 May 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1366328
12 January 2001
Hull Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1361967
16 August 2000
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1418761
15 February 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 815929
4 February 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1045692
13 January 2000
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1429335
29 September 1999
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1372775
22 June 1999
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1089483
24 May 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 496186
13 October 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1437546
30 September 1998
Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1369306
2 September 1998
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1430598
29 October 1997
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1122523
23 October 1997
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1413254
13 October 1997
COI Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1414905
3 September 1997
Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 407510
27 April 1997
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1368215
27 August 1996
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1448807
11 October 1995
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1454252
7 September 1995
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1371161
27 January 1995
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1140876
7 November 1994
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1174533
16 November 1993
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1435421
7 May 1993
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1370604
28 February 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 89473
18 February 1993
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1144748
8 February 1993
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1144561
23 September 1992
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1391788
20 August 1992
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 949983
6 July 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 954327
8 June 1992
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1443323
13 March 1992
Initial Construction-Excluding Oversight · COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1263794
17 February 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 7042
31 December 1990
Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 928066
25 January 1990
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1216235
18 July 1989
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1201432
28 June 1989
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1344607
5 October 1988
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 888741
28 September 1988
COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1349528
15 July 1987
Re-Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1326156
9 February 1987
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1011949
14 October 1986
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1315001
25 September 1986
MARPOL Annex I Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1311910
9 September 1986
Credit Drydock · Deficiency Check · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1306249
1 July 1986
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 997686
19 June 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 964304
2 June 1986
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1295163
5 December 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1295087
31 July 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1291796
3 June 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 984199
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 February 2007
Resolved
OWS not opreational.
Action required: 705 - Other - as specified
Resolved 2 February 2007
Resolution: Repaired. Verified by ABS.
Lifesaving › Line-Throwing Appliances › Lines
Issued 1 March 2006
Resolved
Provide two additional line throwing lines for a total of four onboard.
Due 2 April 2006
Resolved 7 March 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 March 2006
Resolved
Repair Port nav light fault on control panel
Due 2 March 2006
Resolved 7 March 2006
Fire Fighting › Structural - A Class Divisions › Special Category Spaces
Issued 1 March 2006
Resolved
Repair two deck penetrations (electrical) in lab.
Due 2 April 2006
Resolved 7 March 2006
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 1 March 2006
Resolved
Provide SOLAS training manual that meets 46CFR199.180(a)
Due 2 April 2006
Resolved 7 March 2006
Lifesaving › Rescue Boat Equipment › Repair Kit (inflated rescue boat)
Issued 1 March 2006
Resolved
Replace expired glue in rescue boat repair kit.
Due 2 April 2006
Resolved 7 March 2006
Fire Fighting › Ventilation Systems › Operating Controls
Issued 1 March 2006
Resolved
Repair remote ventilation cable on Hazmat storage container.
Due 2 March 2006
Resolved 7 March 2006
Navigation › Piloting/Steering › Marine Charts
Issued 1 March 2006
Resolved
Currently correct all navigation publications and charts for future voyage.
Due 2 March 2006
Resolved 7 March 2006
Construction/Loadline › Hull › Bottom Plating
Issued 18 November 2005
Resolved
Prior to using waste oil tank make permanent repairs to bottom plating in way of temporary doubler.
Due 31 January 2007
Resolved 4 February 2006
Lifesaving › Inflatable Liferafts › Not on Board
Issued 20 July 2005
Resolved
Provide servicing report for liferafts and fixed fire fighting prior to getting underway. Make liferafts available for inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 22 July 2005
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 20 July 2005
Resolved
Properly clean fuel tank vent for incinerator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 22 July 2005
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 20 July 2005
Resolved
Properly remove paint from deck storage locker or provide satisfactory fixed fire fighting.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 22 July 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 July 2005
Resolved
Removed unauthorized electrical equipment from winch room (surge protectors).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 22 July 2005
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 20 July 2005
Resolved
Remove flammables away from electrical control box IVO freezer.
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 22 July 2005
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 20 July 2005
Resolved
Properly repair bulkhead penetrations in hangar space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 22 July 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 20 July 2005
Resolved
Secure all gear on main deck before getting underway.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 22 July 2005
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 20 July 2005
Resolved
Remove all unauthorized gear from fan rooms.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 22 July 2005
Stability › Watertight Integrity › General
Issued 20 July 2005
Resolved
Provide visual indicators for fore and aft engine room watertight doors (one on each side of door).
Action required: 705 - Other - as specified
Due 20 August 2005
Resolved 11 September 2005
Resolution: Received e-mail from vessel master stating that the visual indicator for the engine room water tight door has been corrected. A strobe light was installed on 18AUG05.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 September 2003
Resolved
All CO2 pressure vessel to be checked for compliance with 46 CFR 147.65.hydrostatic test requirement any found out of compliance must be Hydro tested. LEGACY COMPONENT DESC: Tanks
Due 31 May 2004
Resolved 31 August 2004
Lifesaving › Lifebuoys
Issued 25 July 2003
Resolved
Replace retro reflective tape on 2 ring buoys, replace buoyant line on 1 ring buoy, and replace 1 ring buoy.
Due 26 July 2003
Resolved 26 July 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 25 July 2003
Resolved
Properly identify and provide operating instructions for paint locker remote CO2 control located on aft stbd main deck.
Due 25 August 2003
Resolved 26 July 2003
Engineering › Diesel Engine (auxiliary)
Issued 25 July 2003
Resolved
Install chafing gear on emergency generator fuel supply hose.
Due 25 August 2003
Resolved 26 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 25 July 2003
Resolved
Properly identify and mark emergency escape from steering compartment located near #2 DC locker.
Due 25 August 2003
Resolved 26 July 2003
Navigation › Collision/Grounding Avoidance
Issued 23 July 2003
Resolved
Repair or replace echo sounding depth recorder. LEGACY COMPONENT DESC: Echo-sounding Device Recorder
Due 26 August 2003
Resolved 11 November 2003
Resolution: New recorder installed. ABS wittness sat test.
Lifesaving › Immersion Suits
Issued 22 July 2003
Resolved
Replace retro reflective tape on 1 immersion suit.
Due 26 July 2003
Resolved 22 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 22 July 2003
Resolved
Properly stow flammables located in main deck locker.
Due 25 July 2003
Resolved 26 July 2003
Documentation › Safety/Response Plans/Programs
Issued 22 July 2003
Resolved
Update fire safety plan as indicated during inspection. LEGACY COMPONENT DESC: Fire Control Plans
Due 26 August 2003
Resolved 12 December 2003
Resolution: New Fire plan reviewed during Nov dry docking. Updated, reprinted, reviewed and approved.
Accommodation/Occupational Safety › Occupational Safety
Issued 22 July 2003
Resolved
Clean up hydraulic oil and remove oily rags from bow thruster space.
Due 26 July 2003
Resolved 26 July 2003
Engineering
Issued 8 May 2001
Resolved
Vsl is to proceed directly from Guam to Naha, Okinawa Japan and make permanent repairs to & test the port Z-drive propulsion system to the satisfaction of the attending CG/ABS marine inspector. No passengers or cargo is authorized. Vessel may cary scientific equipment.
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Navigation
Issued 16 August 2000
Resolved
Provide clear labels/indicators for actual thruster postition in after steering. New labels/indicators must be easily read from the operators' position while controling the thruster position. Steering orders from bridge must correspond directly with new labels/indicators.
Condition: Unknown
Due 16 August 2000
Resolved 16 August 2000
Fire Fighting
Issued 29 September 1999
Resolved
Provide evidence of current, satisfactory hydrostatic test for nine (9) CO2bottles @ main / aux space supply room that are missing current stamps. (Presumed to be 12/91)
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Electrical
Issued 2 September 1998
Resolved
Provide metal support banding at a minimum of 24" jintervals for cabling inthe chart room, upper lab, bosn locker, electrician shop, troll winch room,motor room, lower lab, and laundry.
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Fire Fighting
Issued 2 September 1998
Resolved
Provide approved Fire Control plans and post them in a permanent location.
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Accommodation/Occupational Safety
Issued 13 October 1997
Resolved
Remove lines on ladder from bos'un hold to main deck emergency escape (safety hazard).
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Construction/Loadline
Issued 13 October 1997
Resolved
Repair water leak in way of bos'un hold to maindeck watertight hatch.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Lifesaving
Issued 13 October 1997
Resolved
Provide warning stating "When alarm sounds vacate at once. Carbon Dioxide being released" in way of Paint Locker (Compartment 1-6-2) and Inflammable Locker (Compartment (1-6-1).
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Fire Fighting
Issued 13 October 1997
Resolved
Repair time delay on CO2 fixed fire extinguishing system in way of auxliarymachinery space.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Construction/Loadline
Issued 13 October 1997
Resolved
Demonstrate satisfactory operational test of the vessel's emergency bilge system in way of machinery space.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Construction/Loadline
Issued 13 October 1997
Resolved
Provide repair plans of superstructure forward bulkhead weather damage (buckled).
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Lifesaving
Issued 13 October 1997
Resolved
Provide properly serviced inflatable liferafts for a total of 130 persons.
Condition: Unknown
Due 13 October 1997
Resolved 17 October 1997
Lifesaving
Issued 13 October 1997
Resolved
Conduct Boat Drill (to the water only) to the satisfaction of attending Inspector.
Condition: Unknown
Due 17 October 1997
Resolved 17 October 1997
Fire Fighting
Issued 13 October 1997
Resolved
Conduct fire drill to the satisfaction of attending Inspector.
Condition: Unknown
Due 17 October 1997
Resolved 17 October 1997
Engineering
Issued 13 October 1997
Resolved
Demonstrate satisfactory operational test of vessel's OWS to the satisfaction of attending CG Marine Inspector.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Lifesaving
Issued 13 October 1997
Resolved
Repair leak in stbd rescue boat on port side aft.
Condition: Unknown
Due 4 February 1998
Resolved 4 February 1998
Fire Fighting
Issued 13 October 1997
Resolved
Repair door handle in way of inflammable locker (Compartment 1-6-1
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Construction/Loadline
Issued 27 April 1997
Resolved
INSTALL SOUNDING PIPE IN BALLAST TANK 4-16-1. (46 CFR 56.50-90)
Condition: Unknown
Due 27 April 1997
Resolved 27 April 1997
Construction/Loadline
Issued 27 April 1997
Resolved
REPAIR OR REMOVE AS APPROPRIATE ALL FRACTURED WELDS IN ANTI-ROLL TANK_x001C_ 4-31-0 WHERE BOTTOM TRANSVERSE FRAME FLANGES WERE WELDED TO THE OUTBOARD SIDES OF THE CENTER BALLAST TANKS 3-31-1 AND 3-31-2.
Condition: Unknown
Due 27 April 1997
Resolved 27 April 1997
Construction/Loadline
Issued 27 April 1997
Resolved
MAKE PERMANENT REPAIR TO DEEP PIT IN STARBOARD BULKHEAD IN BALLAST TANK_x001C_ 4-24-0, APPROX FRAME 26, APPROX 8 FEET ABOVE BOTTOM.
Condition: Unknown
Due 27 April 1997
Resolved 27 April 1997
Construction/Loadline
Issued 27 April 1997
Resolved
MAKE FUEL TANKS 4-24-1, 4-38-1, 4-84-0, AND WASTE OIL TANK 4-63-1 AVAILABLEFOR INTERNAL INSPECTION.
Condition: Unknown
Due 27 April 1997
Resolved 27 April 1997
Construction/Loadline
Issued 27 April 1997
Resolved
PROVIDE COPY OF ABS HULL GAUGING REPORT.
Condition: Unknown
Due 27 April 1997
Resolved 27 April 1997
Construction/Loadline
Issued 27 April 1997
Resolved
MAKE PERMANENET REPAIRS TO NON-TIGHT WELDS IN TRUNK 3-16-0, PORT BULKHEAD, TOP AND BOTTOM, BETWEEN FRAMES 26 AND 29, WHERE FUEL IS SEEPING THROUGH FROM FUEL TANK 4-24-2.
Condition: Unknown
Due 27 April 1997
Resolved 27 April 1997
Fire Fighting
Issued 13 March 1992
Resolved
INSTALL STREUCTURAL FIRE PROTECTION DECK INTEGRITY IN WAY OF STAIRWAYS BETWEEN MAIN DECK & O1 DECK AT FRAME 40 AND BETWEEN O2 DECK & O3 DECK AT FRAME 53. INSTALLATION TO BE TO THE SATISFAC TION OF ATTENDING USCG INSPECTOR, PRIOR TO ENGAGING IN OCEANOGRAPHIC RESEARCH.
Condition: Unknown
Due 13 March 1992
Resolved 13 March 1992
Fire Fighting
Issued 13 March 1992
Resolved
INSULATE STORE ROOM AREA FORWARD OF DARKROOM LABORATORY, SPACE 1-50-1, IN ACCORDANCE WITH APPROVED FIRE CONTROL PLAN. VESSEL RESTRICTED TO NOT USING DARKROOM AS A LABORATORY PENDING COMPLETION. INSTALLATION TO BE TO THE SATISFACTION OF ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 13 March 1992
Resolved 13 March 1992
Accommodation/Occupational Safety
Issued 13 March 1992
Resolved
PROVIDE ADEQUATE RELIEF VALVE PROTECTION FOR AIR RECEIVERS LOCATED IN AUXILIARY MACHINERY SPACE. INSTALLATION SHALL BE TO THE SATISFACTION OF ATTENDING USCG INSPECTOR. AIR RECEIVER NOT TO BE PRESSURIZED PENDING COMPLETION.
Condition: Unknown
Due 13 March 1992
Resolved 13 March 1992
Construction/Loadline
Issued 13 March 1992
Resolved
CROP & RENEW TO GOOD METAL DECK PLATING IN MAIN LABORATORY, VICINITY FRAME 94. INSTALLATION TO BE TO THE SATISFACTION OF ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 13 March 1992
Resolved 13 March 1992
Navigation
Issued 13 March 1992
Resolved
RELOCATE RESTRICTED IN ABILITY TO MANUEVER LIGHTS REQUIRTED BY 33 CFR PART 81 APPENDIX A, RULE 27(B) TO COMPLY WITH 33 CFR PART 81 APPENDIX A, 2 (f) (II). (72 COLREGS). VESSEL NOT TO ENGAGE IN OCEANOGRAPHIC RESEARCH PENDING COMPLETION.
Condition: Unknown
Due 13 March 1992
Resolved 13 March 1992
Engineering
Issued 28 September 1988
Resolved
CONDUCT SATISFACTORY OPERATIONAL TESTS ON LOW PRESSURE OIL FIRED HEATING BOILER'S AUTOMATIC CONTROLS.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Lifesaving
Issued 28 September 1988
Resolved
PROVIDE OPERATING INSTRUCTION PLACARD FOR PORT AND STARBOARD LIFEBOATS.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Engineering
Issued 28 September 1988
Resolved
REPAIR/REPLACE INOPERABLE SAFETY RELIEF VALVES ON LOW PRESSURE OIL FIRED HEATING BOILER.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Lifesaving
Issued 15 July 1987
Resolved
REPLACE OUTDATED WATER SUPPLIES IN LIFEBOATS.
Condition: Unknown
Due 15 July 1987
Resolved 15 July 1987
Electrical
Issued 9 September 1986
Resolved
HARDWIRE FLOURESCENT LIGHT OUTSIDE COMPUTER ROOM.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986
Electrical
Issued 9 September 1986
Resolved
SHIELD OR LAG EHUAST MANIFOLD ON UQS GENERATOR.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986
Fire Fighting
Issued 9 September 1986
Resolved
MOUNT OPERATING INSTRUCTIONS AND PIPING SCHEMATIC AT ALL FIXED HALON AND CO2 BOTTLE AND CONTROL LAOCATIONS.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986
Fire Fighting
Issued 9 September 1986
Resolved
REPLACE NON APPROVED FIRE HOSE WITH APPROVED FIRE HOSE.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986