Records from 1986 to 1995. Most recent: inspection, 7 April 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
7 April 1995
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1353726
16 May 1994
Re-Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1370865
12 May 1993
COI Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 831698
16 December 1992
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 829762
13 May 1992
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1268834
12 November 1991
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1312885
5 June 1991
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 933326
3 December 1990
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 907971
4 June 1990
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1242216
20 November 1989
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1223484
20 June 1989
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 902128
14 November 1988
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 893384
20 June 1988
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1206658
16 November 1987
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1332502
29 June 1987
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1010613
29 May 1986
Credit Drydock · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1302447
Fire Fighting
Issued 13 May 1992
Resolved
PROVIDE PROPER MOUNTING BRACKETS FOR THE PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Electrical
Issued 12 November 1991
Resolved
RERUN WIRING USING METALLIC FASTENERS ON NO LESS THAN 24 INCH CENTERS.
Condition: Unknown
Due 12 November 1991
Resolved 12 November 1991
Fire Fighting
Issued 12 November 1991
Resolved
PROVIDE PROPER MOUNTING BRACKET FOR PORTABLE FIRE EXTINGUSHER LOCATED AFT OF OPERATORS CONSOLE.
Condition: Unknown
Due 12 November 1991
Resolved 12 November 1991
Construction/Loadline
Issued 12 November 1991
Resolved
SISTER CRACKED WOODEN FRAMES ALONG PORT AND STARBOARD BOW AREA.
Condition: Unknown
Due 12 November 1991
Resolved 12 November 1991
Construction/Loadline
Issued 12 November 1991
Resolved
REMOVE WET ROT AREAS MARKED ON BUTT BLOCK AND ADJACENT FRAME LOCATED PORT QUARTER AND COVER WITH EPOXY SEALANT.
Condition: Unknown
Due 12 November 1991
Resolved 12 November 1991
Construction/Loadline
Issued 12 November 1991
Resolved
PROPERLY REATTACH AFTER END OF PORT AND STARBOARD BOW SPASH GUARD TO HULL.
Condition: Unknown
Due 12 November 1991
Resolved 12 November 1991
Engineering
Issued 12 November 1991
Resolved
REPLACE RAW WATER INTAKE VALVE.
Condition: Unknown
Due 12 November 1991
Resolved 12 November 1991
Engineering
Issued 3 December 1990
Resolved
REPLACE WASTED FUEL FILTER BRACKET.
Condition: Unknown
Due 3 December 1990
Resolved 3 December 1990
Electrical
Issued 3 December 1990
Resolved
PROPERLY SECURE BATTERY BOX.
Condition: Unknown
Due 3 December 1990
Resolved 3 December 1990
Fire Fighting
Issued 4 June 1990
Resolved
PROVIDE A CURRENT HYDRO FOR THE B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Electrical
Issued 4 June 1990
Resolved
PROVIDE A SUITABLE NON-CORROSIVE LINER FOR THE LEAD ACID BATTERY. INSURE THE BATTERY IS BLOCKED FROM MOVEMENT.
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Engineering
Issued 4 June 1990
Resolved
REPARE OR REPLACE THE FUEL OIL TANK VENTS.
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Accommodation/Occupational Safety
Issued 20 November 1989
Resolved
REPLACE CORRODED SECTION OF BILGE VENT LINE.
Condition: Unknown
Due 20 November 1989
Resolved 20 November 1989
Construction/Loadline
Issued 20 November 1989
Resolved
REPAIR TWO 6-INCH SECTIONS OF WORMSHOE.
Condition: Unknown
Due 20 November 1989
Resolved 20 November 1989
Engineering
Issued 20 June 1989
Resolved
PROVIDE FLAME SCREENS FOR FUEL TANK VENTS.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Electrical
Issued 20 June 1989
Resolved
PROPERLY DEADEND OR REMOVE OLD CB WIRING UNDER DASH CONSOLE.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Engineering
Issued 20 June 1988
Resolved
PROVIDE HAND BILGE PUMP.
Condition: Unknown
Due 20 June 1988
Resolved 20 June 1988
Lifesaving
Issued 20 June 1988
Resolved
PROVIDE 8 ADULT PFD'S; UNTIL ON BOARD, PASSENGERS REDUCED BY 8.
Condition: Unknown
Due 20 June 1988
Resolved 20 June 1988
Lifesaving
Issued 20 June 1988
Resolved
PROVIDE RING BUOY FOR VESSEL.
Condition: Unknown
Due 20 June 1988
Resolved 20 June 1988
Fire Fighting
Issued 29 June 1987
Resolved
PROVIDE PROOF THAT BOTH FIRE EXTINGUISHERS HAVE BEEN HYDROSTATICALLY TESTEDWITHIN THE LAST 5 YEARS OR HAVE BOTH EXTINGUISHERS HYDROSTATICALLY TESTED BEFORE THE NEXT REINSPECTION.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987