← All vessels
AO C 245
AO C 245 is a 1967 tank barge. The Coast Guard has recorded 55 inspections since 1984, most recently in June 2000, along with 15 deficiencies.
Records from 1984 to 2000. Most recent: inspection, 12 June 2000.
- Built
- 1967
- Last inspected
- 12 June 2000
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 15 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
…with no type recorded34
Years with a record
17 calendar years (1984–2000)
The 55 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it2040 - Regulatory (Subpart C or D), Gross Ton
2040 - Regulatory (Subpart C or D), Net Ton
2040 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 55
12 June 2000
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1050278
6 January 1999
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1430633
16 January 1998
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1110705
3 December 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 527411
13 February 1997
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1443811
6 November 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 484875
29 May 1996
Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1390268
26 February 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 497969
20 February 1996
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 886120
29 August 1995
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 453744
12 June 1995
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 876259
21 May 1995
Damage Survey
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 871897
21 March 1995
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 827838
19 May 1994
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 446616
4 May 1994
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1170768
20 April 1993
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 458857
15 April 1993
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1133434
9 February 1993
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 487200
18 June 1992
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 949868
1 April 1992
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 499826
7 January 1992
Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1261796
13 June 1991
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 513731
26 April 1991
Examination of Repairs · COI Inspection · Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1215637
19 July 1990
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 463935
9 July 1990
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 480204
29 January 1990
Deficiency Check · COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 909485
8 January 1990
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 918394
7 December 1989
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 446848
7 December 1989
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 486606
11 July 1989
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 530450
7 March 1989
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 894377
20 February 1989
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1349472
11 January 1989
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 447498
14 July 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 514006
25 March 1988
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1296848
28 August 1987
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 538662
17 March 1987
Examination of Repairs · Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1020005
29 January 1987
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 439735
30 October 1986
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 444805
2 September 1986
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 458459
25 June 1986
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 465667
16 May 1986
Examination of Repairs · Damage Survey
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 990992
19 March 1986
Credit Drydock · Deficiency Check · COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 994271
29 January 1986
Type not recorded
No type recorded · MSO CINCINNATI · Activity 445412
29 January 1986
Type not recorded
No type recorded · MSO CINCINNATI · Activity 1304808
30 December 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 471206
18 October 1985
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 994566
23 August 1985
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 500552
8 August 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 485791
8 August 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 983348
10 June 1985
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1292090
21 January 1985
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 978604
16 January 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 1285291
7 September 1984
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 481069
14 August 1984
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 498918
Deficiency record · 15
Construction/Loadline
Issued 21 May 1995
Resolved
MAKE PERMANENT REPAIRS TO DAMAGED MOORING BUTTON PRIOR TO LOADING.
Construction/Loadline
Issued 26 April 1991
Resolved
THE SIDE PLATE WAS INDENTED AND WASTED BELOW 25% OF THE ORIGINAL PLATE_x001C_ THICKNESS. ALL SIDE PLATE, DECK KNUCKLES, BILGE KNUCKLES AND RELATED_x001C_ FRAMING WAS REPLACED TO THE SATISFACTION OF THE COGNIZANT O.C.M.I.
Construction/Loadline
Issued 8 January 1990
Resolved
PRIOR TO LOADING CARGO MAKE PERMANENT REPAIRS TO THE 12" HEADLOG FRACTURE IN WAY OF THE NO. 1 STBD CARGO TANK, LOCATED APPROXIMATELY 2'4" DOWN FROM DECK.
Construction/Loadline
Issued 20 February 1989
Resolved
MAKE PERMANENT REPAIRS TO THE HOLE LOCATED IN THE CENTER OF THE STERN AT THE APPROXIMATELY 8' DRAFT LEVEL. REPAIRS ARE TO BE COMPLETED PRIOR TO LOADING THE NEXT CARGO BUT NO LATER THAN THE COMPLIANCE DATE.
Construction/Loadline
Issued 16 May 1986
Resolved
MAKE BARGE AVAILABLE FOR EXTERNAL INSPECTION TO SET UP BOTTOM PLATE AND SETIN BOTTOM KNUCKLE PLATE IN WAY OF STBD #5 AND STBD #6 CARGO TANKS PRIOR TO LOADING CARGO BUT NOT LATER THAN COMPLIANCE DATE.
Construction/Loadline
Issued 29 January 1986
Resolved
MAKE PERMANENT REPAIRS TO ALL FRACTURES AND AREAS OF TEMPORARY REPAIRS IN WAY OF CORNER VOIDS AND IN THE AREA OF THE DECK KNUCKLE.
Construction/Loadline
Issued 29 January 1986
Resolved
UPON COMPLETION OF OFFLOADING THE ONBOARD PRODUCT, VSL IS TO PROCEED TO A REPAIR FACILITY AND BE PRESENTED FOR CG INSPECTION OF AND PERMANENT REPAIRSTO DAMAGE IN WAY OF THE CORNER VOIDS. ITEM TO BE COMPLETED PRIOR LOADING NEXT VESSEL CARGO OR COMPLIANCE DATE, WHICHEVER OCCURS FIRST.
Construction/Loadline
Issued 29 January 1986
Resolved
MAINTAIN TEMPORARY REPAIRS ON ALL HOLES AND FRACTURES ON THE VESSEL.
Construction/Loadline
Issued 8 August 1985
Resolved
REPAINT "DANGER KEEP OUT" ON NO. 5 STARBOARD CARGO TANK HATCH.
Construction/Loadline
Issued 10 June 1985
Resolved
REMOVE WATER AND CHECK FOR LEAKS IN THE PORT & STBD BOW CORNER VOIDS AND THE PORT STERN CORNER VOID PRIOR TO LOADING CARGO BUT NOT LATER THAN COMPLIANCE DATE.
Construction/Loadline
Issued 10 June 1985
Resolved
MAKE AND MAINTAIN TEMPORARY REPAIRS TO THE FOLLOWING FRACTURES WITH PERMA- NENT REPAIRS TO BE COMPLETED AT THE NEXT GAS FREE PERIOD, BUT NOT LATER THAN COMPLIANCE DATE: 1) 7' FRACTURE ALONG THE PORT STERN CORNER DECK KNUCKLE, 2) 2' FRACTURE ALONG THE STBD BOW CORNER DECK KNUCKLE.
Construction/Loadline
Issued 16 January 1985
Resolved
DEWATER STERN VOID PRIOR TO DEPARTING PORT OF CINCINNATI.
Construction/Loadline
Issued 16 January 1985
Resolved
MAKE TEMPORARY REPAIRS TO THE TWO-INCH (2") CRACK, STARBOARD SIDE STERNVOID PRIOR TO LOADING NEXT CARGO.
Construction/Loadline
Issued 16 January 1985
Resolved
MAINTAIN TEMPORARY REPAIRS ON TWO-INCH (2") CRACK ON THE VESSEL'S STERN, STARBOARD SIDE.
Construction/Loadline
Issued 16 January 1985
Resolved
PERMANENT REPAIRS ARE TO BE MADE TO THE TWO-INCH (2") CRACK ON THE STERN AT THE NEXT SCHEDULED DRYDOCK OR REPAIR PERIOD, WHICHEVER OCCURS FIRST.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.