← All vessels
AO S 237
AO S 237 is a 1960 tank barge. The Coast Guard has recorded 48 inspections since 1984, most recently in July 1997, along with 9 deficiencies.
Records from 1984 to 1997. Most recent: inspection, 25 July 1997.
- Built
- 1960
- Last inspected
- 25 July 1997
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
…with no type recorded27
Years with a record
14 calendar years (1984–1997)
The 48 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it1853 - Regulatory (Subpart C or D), Gross Ton
1853 - Regulatory (Subpart C or D), Net Ton
1853 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 48
25 July 1997
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1116570
1 July 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 756361
30 June 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 190597
28 June 1996
Examination of Repairs · COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1371458
10 August 1995
Examination of Repairs · Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 873694
14 July 1995
Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 875831
22 June 1995
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 879703
17 April 1995
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 463803
4 April 1995
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 525624
12 October 1994
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1175295
6 July 1994
Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 862567
12 June 1994
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1175535
1 June 1994
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 507143
9 August 1993
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1153275
14 June 1993
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 461024
26 January 1993
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 513668
24 July 1992
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 533777
14 July 1992
COI Inspection · Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 959470
19 January 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 484642
11 July 1991
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 500719
6 March 1991
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 929684
6 March 1991
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1247642
7 January 1991
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 456182
5 September 1990
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 487993
5 March 1990
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 450156
27 February 1990
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1226175
9 February 1990
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 529064
22 September 1989
Damage Survey · Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 895353
29 May 1989
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 509597
24 April 1989
Examination of Repairs · Damage Survey
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1031581
31 March 1989
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1339580
6 June 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 463716
28 April 1988
Examination of Repairs · Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1038872
23 October 1987
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 530978
2 April 1987
Hull Examination · Examination of Repairs · COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1021717
10 January 1987
Drydock Extension
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1312965
23 June 1986
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1302261
6 June 1986
Type not recorded
No type recorded · MSO CINCINNATI · Activity 1302318
3 February 1986
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 991122
29 October 1985
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 521001
16 September 1985
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 533205
20 March 1985
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 454034
5 March 1985
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 980328
21 February 1985
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 466789
29 January 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 464443
29 January 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 978610
30 August 1984
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 510597
18 June 1984
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 520515
Deficiency record · 9
Construction/Loadline
Issued 14 July 1995
Resolved
PROVE INTEGRITY OF ALL CARGO TANKS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. SUSPECT PIN-HOLE LEAK(S) AT UNKNOWN LOCATION(S) DUE TO SHEEN SIGHTED AT THE VESSEL UNTIL IT WAS DISCHARGED.
Deck/Cargo
Issued 12 June 1994
Resolved
MAKE PERMANENT REPAIRS TO MASTER VALVE IN WAY OF TEMPORARY REPAIRS AT BASE OF VALVE.
Construction/Loadline
Issued 12 June 1994
Resolved
MAKE PERMANENT REPAIRS TO EIGHT (8) INCH FRACTURE IN WAY OF BOW PORT CORNER, AFT OF RUB PAD AT DECK KNUCKLE. MAINTAIN TEMPORARY REPAIRS.
Deck/Cargo
Issued 31 March 1989
Resolved
PROVIDE PROOF OF HYDROSTATIC TEST OF CARGO PIPING PRIOR TO NEXT OFFOLADING OF CARGO.
Construction/Loadline
Issued 2 April 1987
Resolved
ENTIRE SIDE SHELL, TRANSOM, GUNWALE, BOW RAKE BOTTOM, BILGE KNUCKLE PLATE AND ATTACHED STRUCTURAL SUPPORT MEMBERS PORT AND STARBOARD RENEWED AS ORIGINAL.
Construction/Loadline
Issued 6 June 1986
Resolved
MAKE TEMPORARY REPAIRS TO THE HOLE NOTED IN THE NO. 3 CARGO TANK AT APPROX.7' DRAFT AND 10' FORWARD OF THE CARGO TANK AFT BULKHEAD PRIOR TO DEPARTING THE PORT OF CINCINNATI.
Construction/Loadline
Issued 6 June 1986
Resolved
PRIOR TO LOADING THE NEXT VESSEL CARGO, PRESENT THIS VESSEL FOR AN INSPEC- TION OF SIDE PLATE AND REPAIRS TO ALL FRACTURES AND HOLES.
Deck/Cargo
Issued 29 January 1985
Resolved
REPAIR/REPLACE THE FLAME SCREEN IN NO.2 PORT CARGO TANK ULLAGE OPENING.
Deck/Cargo
Issued 29 January 1985
Resolved
RENEW THE PACKING ON NO.8 PORT CARGO TANK VALVE REACH ROD PACKING GLAND.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.