MAURY USCG vessel records Sign in
← All vessels

ADIRONDACK

ADIRONDACK is a 1994 passenger vessel (inspected). The Coast Guard has recorded 63 inspections since 1994, most recently in June 2026, along with 50 deficiencies, 1 operational control and 2 casualty investigations between 2002 and 2008.

Records from 1994 to 2026. Most recent: inspection, 22 June 2026.

Built
1994
Last inspected
22 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC5364
405709
Flag
UNITED STATES
367040020
Maury page id
psix-405709

Inspections, by type

…with no type recorded9
Years with a record 29 calendar years (1994–2026)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.8 ft × 16.0 ft × 8.0 ft
Registered tonnagegross 41 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSCARANO BUILDING, INC. · ALBANY, NY, UNITED STATES · built 1994
Hull materialWood
PropulsionDiesel Direct
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portNEWPORT, RI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Simplified, Gross Ton
37 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC5364MMSI 367040020 · active · compulsorily equipped · granted 4 June 2025, expires 6 May 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 63

22 June 2026 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8412009
23 March 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8331055
9 June 2025 Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8148072
15 May 2024 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7912674
5 March 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7873994
17 May 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7689675
11 May 2022 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7449999
30 March 2022 Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7422239
13 September 2021 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7311044
12 June 2020 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6972196
18 May 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6955246
10 March 2020 Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6925523
25 February 2020 Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6915196
9 July 2019 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6742908
25 July 2018 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6484115
15 March 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6431550
19 June 2017 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6180069
27 June 2016 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5918675
15 March 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5838242
30 May 2012 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4331265
17 February 2012 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4246427
29 March 2010 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3707947
6 July 2009 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3604581
15 April 2009 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3473930
30 August 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3320144
21 May 2008 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3212900
24 July 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3005910
27 June 2007 Annual Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2976550
21 March 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2902539
2 August 2006 MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2734075
5 May 2005 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2356558
25 April 2005 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2343142
13 September 2004 Type not recorded
No type recorded · Station New York · USCG Northeast District (CGD-NE) · Activity 2196865
12 July 2004 MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2129990
28 May 2004 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2080728
10 June 2003 MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1813330
22 April 2003 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1803875
5 July 2002 Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1658256
3 May 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1613247
7 October 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1073944
31 May 2001 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1370266
12 April 2001 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1457923
13 June 2000 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1051110
7 April 2000 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1361401
7 December 1999 Deadweight Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1046554
9 July 1999 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1361015
12 May 1999 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 796018
6 May 1999 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1462745
16 June 1998 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1126594
22 June 1997 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 23753
12 May 1997 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1109854
30 April 1997 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1095562
10 June 1996 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1088737
25 May 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 61963
15 November 1995 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 873807
2 August 1995 Excursion Permit
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1193536
29 July 1995 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 229928
12 June 1995 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 872470
10 November 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1174311
11 June 1994 Deficiency Check · Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1356871
10 June 1994 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1028215
2 June 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1328418
16 May 1994 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 860471

Deficiency record · 50

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 June 2025 Resolved
The design, materials, and construction of...standing rigging on a sailing vessel must be suitable for intended service...Repairs or alterations to...equipment that effect the safety of the vessel must not be made without the approval of the cognizant [name withheld] bent swaged fitting at waterline of the boomkin stay as well as wire unfurling. 46CFR 177.330; 46CFR 176.700
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2025
Resolution: Photograph of boomkin stay replacement forward to office.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 17 May 2023 Resolved
Remote fuel shutoff stations shall be marked in at least 1-inch letters indicating purpose of the valve and direction of operation. Main engine fuel shutoff station requires exterior markings. 46 CFR 185.30-10 (OLD T, OCT 1994)
Action required: 10 - Deficiency Rectified
Resolved 17 May 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 July 2019 Resolved
PROVIDE A COPY OF BOTH THE ORIGINAL SAIL PLAN AND THE UPDATED SAIL PLAN TO THE OCMI FOR REVIEW. 46 CFR 176.802(a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 15 July 2019
Resolution: Vessel rep submitted original and new sail plans.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 July 2019 Resolved
ALL CONNECTIONS MUST BE MADE IN AN ENCLOSURE. MULTIPLE DEAD-END CABLES DISCOVERED WITH ELECTRICAL TAPE AROUND THE ENDS IN THE LAZARRETTE. REMOVE WIRES OR PROPERLY SECURE THE ENDS AND PLACE INTO AN ENCLOSURE. 46CFR183.340(i)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 22 July 2019
Resolution: Cleared by way of photo.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 July 2019 Resolved
ALL WIRING SHALL BE INSTALLED USING METAL SUPPORTS SPACED NOT MORE THAN 24-INCHES APART. WIRING RUN IN THE ENGINE ROOM UTILIZING ZIP STRAPS (ATTACHING TO METAL CLAMP SUPPORTED WIRES). 46CFR183.340(a(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 22 July 2019
Resolution: Cleared by way of photo.
Documentation › Certificates/Documents › Stability Letter
Issued 30 May 2012 Resolved
In accordance with AAWPP Vessel's stability is reduced to 43 passenegers 46 Total persons. Vessel shall have stbility addendum posted.
Action required: 705 - Other - as specified
Due 15 August 2012
Resolved 5 July 2012
Resolution: IAW stability letter, total persons reduction from 63 to 54 total; 49 pax. Letter submitted by o/o to MSC on 05JUL12 requesting stability addendum.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 21 May 2008 Resolved
Fixed Firefighting System Over-ride Function Inoperable.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2008
Documentation › Certificates/Documents › FCC SSL
Issued 27 June 2007 Resolved
Obtain current FCC Radio Safety Certificate. Vessel operation restricted to within 1000 feet from land until this requirement is met.
Action required: 705 - Other - as specified
Due 27 July 2007
Resolved 24 July 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 June 2007 Resolved
Repair/replace life ring floating watertight.
Action required: 705 - Other - as specified
Due 27 July 2007
Resolved 24 July 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 March 2007 Resolved
Clean corroded battery terminals in engine space.
Action required: 705 - Other - as specified
Resolved 27 July 2007
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 21 March 2007 Resolved
Replace non-metal wire hangers with metal hangers throughout vsl.
Action required: 705 - Other - as specified
Resolved 27 July 2007
Construction/Loadline › Penetrations › Pipe Flange
Issued 2 August 2006 Resolved
Replace through-hull PVC fitting for MSD ventilation with metallic fitting.
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 31 August 2006
Resolution: Fitting now metallic
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 August 2006 Resolved
Provide bracket for ring buoy waterlight.
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 31 August 2006
Resolution: Waterlight bracketed
Communications › Radio Communications › VHF Radiotelephone
Issued 2 August 2006 Resolved
Place emergency broadcast placard IVO the operating station.
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 31 August 2006
Resolution: Placard mounted at operating station.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 2 August 2006 Resolved
Stow child lifejackets in separate location from adult and adequately mark location.
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 31 August 2006
Resolution: Lifejackets properly stowed in marked locations.
Stability › Watertight Integrity › General
Issued 2 August 2006 Resolved
Make bulkhead between engine room and lazarette watertight where electrical wires pass through.
Action required: 705 - Other - as specified
Due 16 August 2006
Resolved 31 August 2006
Resolution: Bulkhead watertight.
Documentation › Certificates/Documents › FCC SSL
Issued 2 August 2006 Resolved
Provide proof of valid radio safety certificate onboard vessel. Vessel restricted to NMT 1000ft from shore until requirement is cleared.
Action required: 705 - Other - as specified
Due 9 August 2006
Resolved 2 August 2006
Resolution: Received copy of valid radio safety certificate.
Documentation › Certificates/Documents › FCC SSL
Issued 5 May 2005 Resolved
Provide FCC license
Due 19 May 2005
Resolved 13 May 2005
Documentation › Logs/Records › Logbook (official)
Issued 5 May 2005 Resolved
Provide fixed binding log book
Due 12 May 2005
Resolved 12 May 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 5 May 2005 Resolved
Provide nav station extinguisher
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2005
Resolved 13 May 2005
Engineering › Bilge Water Management System › Piping
Issued 5 May 2005 Resolved
Provide oil resistant hoses
Due 1 November 2005
Resolved 20 March 2006
Resolution: Contacted rep and he informed me that the def would be cleared by 01May2006. Cleared def, and transferred to "Special Note."
Stability › Watertight Integrity › Weathertight Enclosure
Issued 5 May 2005 Resolved
Repair as new fwd hatch
Due 19 May 2005
Resolved 13 May 2005
Engineering › Bilge Water Management System › Valve
Issued 5 May 2005 Resolved
Provide handle for fwd bilge valve
Due 5 May 2005
Resolved 13 May 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 July 2004 Resolved
Properly post all pages of COI and current CG-858 amendments (reduced livesaving equipment).
Due 19 July 2004
Resolved 9 September 2004
Navigation › Piloting/Steering › Marine Charts
Issued 12 July 2004 Resolved
Provide current nautical chart for area of operation.
Due 19 July 2004
Resolved 9 September 2004
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 July 2004 Resolved
Make machinery compartment aft bulkhead watertight IWO holes at upper portion of the bulkhead.
Due 19 July 2004
Resolved 9 September 2004
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 12 July 2004 Resolved
Properly place lifejacket donning instruction in view of passengers.
Due 19 July 2004
Resolved 9 September 2004
Lifesaving › Lifebuoys › Serviceable
Issued 12 July 2004 Resolved
Repair of replace both ring life buoys.
Due 19 July 2004
Resolved 9 September 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 July 2004 Resolved
Prove proper operation of aft compartment bilge high level alarm. Vsl is required to make visual inspections of aft compartment every 1/2 hour and log the same.
Due 19 July 2004
Resolved 12 July 2004
Resolution: Vsl representative repaired wiring prior to inspectors departure and demonstratured working audible and visual alarm.
Documentation › Certificates/Documents › FCC SSL
Issued 12 July 2004 Resolved
Provide current FCC Radio safety certficate. Vsl is restricted from operating more than 1000 ft from shore while carrying passengers until corrected.
Due 30 November 2004
Resolved 5 May 2005
Navigation › Piloting/Steering
Issued 10 June 2003 Resolved
Update charts to local area and obtain recent coast pilot and light list. LEGACY COMPONENT DESC: Marine Charts
Due 17 June 2003
Resolved 8 June 2004
Resolution: Received faxed receipt for charts/pubs.
Lifesaving
Issued 10 June 2003 Resolved
Replace battery to EPIRB. Restricted to less than 3 NM from shore until cleared by attending marine inspector.
Action required: 705 - Other - as specified
Resolved 8 June 2004
Resolution: EPIRB removed from vessel based on route reduction.
Lifesaving › Visual Distress Signals (General)
Issued 10 June 2003 Resolved
Replace/repair light to 10 man life float. Vsl restricted to less than 1 NM from shore until cleared by attending marine inspector.
Action required: 705 - Other - as specified
Resolved 8 June 2004
Resolution: Life floats removed from vessel based on route reduction.
Electrical › Electrical Distribution System (service)
Issued 10 June 2003 Resolved
Properly secure wire in bilge IWO ladder. LEGACY COMPONENT DESC: Wiring
Due 17 June 2003
Resolved 8 June 2004
Resolution: Faxed statement attested to wires being properly terminated.
Lifesaving › Rescue Boat
Issued 10 June 2003 Resolved
Replace ladder used for MOB drill to satisfaction of attending marine inspector. LEGACY COMPONENT DESC: Boarding Ladder
Due 17 June 2003
Resolved 8 June 2004
Resolution: Rigid rescue ladder provided.
Engineering › Bilge Water Management System › Piping
Issued 22 April 2003 Resolved
Found bilge piping to be of copper pipe with sweated on fittings. This does not meet the requirements of 46CFR182.710 and 46CFR182.730(a)(4). Provide plans to ACTNY Plan review office for replacement of bilge piping. Piping to be replaced prior to 30APR04. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 29 October 2004
Resolution: Cleared as long-standing
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 5 July 2002 Resolved
Replace O-ring to stbd main transmission.
Due 19 July 2002
Resolved 5 September 2002
Resolution: New O-ring installed satisfactory..
Lifesaving › Buoyant Apparatus
Issued 5 July 2002 Resolved
Properly configure survival craft with permanently mounted float free light and painter.
Condition: Improper Installation
Due 19 July 2002
Resolved 5 September 2002
Resolution: Float free light mounted properly and survival craft configuration is now correct.
Deck/Cargo
Issued 12 April 2001 Resolved
Vessel rigging not in place. Notify attending Marine Inspector upon rerigging of vessel for rigging inspection, or provide inspector with report from third party rigging surveyor.
Condition: Unknown
Due 15 May 2001
Resolved 5 July 2002
Resolution: During inspection on 05JUL02, discussed outstanding requirement with vessel [name withheld] were not rigged at previous inspection and this requirement was issued. While onboard for first annual reinspection, vessel had all sails properly rigged.
Lifesaving
Issued 7 April 2000 Resolved
Prior to carrying passengers for hire conduct fire and man overboard drillsin the presence of marine inspector.
Condition: Unknown
Due 16 April 2000
Resolved 16 April 2000
Electrical
Issued 6 May 1999 Resolved
Support cable in engine room with metal ties every 24".
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Fire Fighting
Issued 6 May 1999 Resolved
Service fire extinguishers.
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Lifesaving
Issued 6 May 1999 Resolved
Vessel not to conduct commercial operations until NY03-07 are met.
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Construction/Loadline
Issued 6 May 1999 Resolved
Seal Bulkhead penetrations with wood equivalent.
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Construction/Loadline
Issued 6 May 1999 Resolved
Place bilge alarms in all compartments(not for'pk).
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Fire Fighting
Issued 6 May 1999 Resolved
Install and make fixed fire fighting available for inspection.
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Accommodation/Occupational Safety
Issued 6 May 1999 Resolved
Install railing and make available for inspection.
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Navigation
Issued 6 May 1999 Resolved
Install steering and make available for inspection.
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Lifesaving
Issued 16 June 1998 Resolved
THE VESSEL MAY NOT OPERATE MORE THAN 1 MILE FROM SHORE UNTIL THE BUOYANT APPARATUS HAS BEEN REPAIRED OR REPLACED.
Condition: Unknown
Due 16 June 1998
Resolved 16 June 1998
Accommodation/Occupational Safety
Issued 10 November 1994 Resolved
PROVIDE PROPER RAILINGS BY ADDING 3 STANTIONS ON EACH SIDE AND REPLACING TEMPORARY ROPE WITH NETTING OR CABLE WITH 6 INCH SPACING.
Condition: Unknown
Due 10 November 1994
Resolved 10 November 1994

Casualty record · 2

3 May 2002Routine · role: Involved in a Marine Casualty · activity 1613247
30 August 2008Routine · role: Involved in a Marine Casualty · 1 injured · activity 3320144
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.